Analysis of Pollutant load Reduction Efficiency with Riparian Buffer System Using the SWAT-REMM (SWAT-REMM을 적용한 수변림 조성에 따른 하천오염부하 저감효과 분석)

  • Choi, Youn Ho;Ryu, Ji Chul;Hwang, Ha Sun;Kum, Dong Huyk;Park, Youn Shik;Jung, Young Hun;Choi, Joong Dae;Lim, Kyoung Jae
    • Journal of Korean Society on Water Environment
    • /
    • v.31 no.2
    • /
    • pp.166-180
    • /
    • 2015
  • Pollutant in watersheds comes from two major sources which are NPS (nonpoint source pollution) and PS (point source pollution). Most of the pollutant can be treated by wastewater treatment plants. However, wastewater treatment plants may not be an appropriate practice to improve water quality for the watersheds with large portion of NPS pollutant and NPS pollution from direct runoff and baseflow has different characteristics. Therefore the practices to improve water quality need to be comprehensive for pollutants by both direct runoff and baseflow. Riparian buffer, one of practices to manage pollutant in watershed, has been applied to reduce pollutant not only from direct runoff but also baseflow. In this study, the scenarios for pollutant reduction by wastewater treat plants and the nitrogen reduction by riparian buffer were simulated using SWAT-REMM to suggest an effective plan for pollutant reduction from baseflow. Riparian buffer provided nitrogen reduction of 0.2~75.0% in YbB watershed and 38.0~47.0% in GbA watershed. The result indicates that riparian buffer is effective to reduce the pollutant especially from baseflow, and it suggested as suitable for the a watershed which WWTP discharge is not capable to reduce enough pollutant.

Estimation of Flows and Pollutant Loads from GIS Analysis using Cell-based Geospatial and Georgraphic Information Data (격자기반의 지형 및 지리정보자료와 GIS분석기법을 이용한 유역의 유출량 및 오염부하량 추정)

  • Cho, Jae-Myoung;Lee, Mi-Ran;Yun, Hong-Sik
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.29 no.4
    • /
    • pp.381-392
    • /
    • 2011
  • Pollutant loads calculated with unit factor method can not identity seasonal variations of pollutant inputs. Estimation of pollutant loads considering rainfall runoff can overcome these limits. SCS curve number method was applied to estimate runoff of each event of Koeup watershed of Koheung estuary lake. SCS curve numbers were calculated based upon land use, soil types of the catchment using GIS. Point and nonpoint source pollutant loads were summed up for total loads estimation. Those from nonpoint source were estimated by multiplying the calculated runoff and expected mean concentrations (EMC) presented by the Minister of Environment of Korea. DEM can present three dimensional views of a terrain, identity stream networks and flow accumulation. Furthermore, it can examine accumulated pollutant loads of specific point of a catchment. Therefore, cell based pollutant load estimation was attempted using DEM. ArcView was utilized to collect, store and manipulate spatial and attribute data of pollutant sources and features of the catchment. Cell-based DEM which was established by the GRID module of ARC/INFO was employed to estimate flows and pollutant loads.

Quantitative Estimation of Nonpoint Source Load by BASINS/HSPF (BASINS/HSPF 모형을 활용한 비점오염부하의 정량적 평가)

  • Lee, Jae-Woon;Kwon, Hun-Gak;Yi, Youn-Jeong;Yoon, Jong-Su;Han, Kun-Yeun;Cheon, Se-Uk
    • Journal of Environmental Science International
    • /
    • v.21 no.8
    • /
    • pp.965-975
    • /
    • 2012
  • Loading of NPS pollutant was valued through simulation by using BASINS/HSPF model which can simulate runoff volume in rainfall by time. For the verification of the model, it was analyzed the scatter diagram of the simulation value and measure value of water quality and runoff volume in Dongcheon estuary. Using the built model, a study on the time-variant characteristics of runoff and water quality was simulated by being classified into four cases. The result showed the simulation value was nearly same as that of the measured runoff. In the result of fit level test for measured value and simulated value, correlation of runoff volume was computed high by average 0.86 and in the water quality items, fit level of simulation and measurements was high by BOD 0.82, T-N 0.85 and T-P 0.79.

Design of Structural BMPs for Low Impact Development (LID) Application and Modelling Its Effect on Reduction of Runoff and Nonpoint Source Pollution: Application of LIDMOD2 (저영향개발(LID)적용을 위한 구조적 BMPs의 유출량 및 비점오염저감 효과모의: LIDMOD2 적용)

  • Kim, Jung Jin;Kim, Tae-Dong;Choi, Donghyuk;Jeon, Ji-Hong
    • Journal of Korean Society on Water Environment
    • /
    • v.27 no.5
    • /
    • pp.580-586
    • /
    • 2011
  • Low impact development (LID) technique is recently proposed as new concept to reduce surface runoff and pollutant loading with various best management practices (BMPs). In this study, LIDMOD2, which is one of the model to evaluate LID, was applied at Mohyeon developing area to evaluate the redcution of annual runoff and pollution loading, cost-reduction efficient by LID with design of structural BMPs including bioretention, wet pond, and wetland. As a simulation results, the bioretention had the highest reduction efficiency for runoff (41.43%), and 22% for T-N and 22% for BOD. Wet pont had the highest reduction efficiency for T-P as showing 25% of reduction rate. As a results of cost-reduction efficient, wet pont represented the highest cost-effective for T-N and BOD with showing 0.43 T-P kg/million won and 17.37 BOD kg/million won, respectively, and bioretention represented the highest cost-effective for T-P with showing 2.52 T-P kg/million won. LID technology could reduce effectively surface runoff and nonpoint source pollution and construct sustainable development. LIDMOD2 could be suggested as useful tool to evaluate and design LID.

Characteristics of Non-Point Sources Pollutant Loads at Paddy Plot Located at the Valley Watershed during Irrigation Periods (관개기 곡간지 유역 필지논에서의 비점원오염물질 유출특성)

  • Han, Kuk-Heon
    • KCID journal
    • /
    • v.18 no.1
    • /
    • pp.94-102
    • /
    • 2011
  • The aim of this study was to evaluate the load of non-point sources pollutant at a paddy plot located at the valley watershed during irrigation period. Irrigation, runoff and water quality data in the paddy plot were analyzed periodically from June 1 to October 31 in 2005. The observed amount of precipitation, irrigation, runoff for the experimental paddy plot during the irrigation period was 1,297.8, 223.2, and 825.4mm, respectively. Total-N concentrations ranged from 3.73 to 18.10mg/L, which was generally higher than the quality standard of agricultural water (1.0mg/L). Total-P concentrations ranged from 0.111 to 0.243mg/L and the average was 0.139mg/L. The observed runoff pollutants loadings from the paddy plot were measured as 34.4 kg/ha for T-N, 1.0 kg/ha for T-P and 213.8 kg/ha for SS. The non-point sources pollutant load in drainage water depends on rainfall and surface drainage water amount from the paddy plot. We are considering that these results were affected by rainfall as well as hydrological condition, soil management, whether or not fertilizer application, cropping, rice straw and plowing.

  • PDF

Analysis of First Flush of Recreation Park and Removal Rate According to Rainfall-Runoff Storage Depth (위락시설지역의 초기세척현상과 초기 강우-유출고 저류에 따른 저감효율 분석)

  • Jung, Jae-Woon;Park, Ha-Na;Choi, Dong-Ho;Baek, Sang-Soo;Yoon, Kwang-Sik;Baek, Won-Jin;Beam, Jin-A;Lim, Byung-Jin
    • Journal of Korean Society on Water Environment
    • /
    • v.29 no.5
    • /
    • pp.648-655
    • /
    • 2013
  • Nonpoint source pollution characteristics of recreation park was investigated. Runoff ratio of recreation park ranged 23-57%, which was lower than other urban area since impervious area was less than 37%. The average BOD, COD, TOC, SS, T-N, T-P, were 14.09, 32.86, 12.19, 121.51, 7.78 and 0.72 mg/L, respectively. First flush of recreation park was analyzed by normalized cumulative load - volume curve and mass first flush ratio(MFFn), MFF10 for BOD, COD, SS, T-P, T-N, TOC were 2.90, 1.59, 2.15, 2.74, 2.60, and 1.59, respectively. Observed data showed that 62% of pollutant could be removed by storaging 5 mm rainfall-runoff and even 3 mm depth could store up to 50% of pollutant in runoff.

Determination of EMC and Washoff Characteristics of Stormwater Runoff from Broad-Leaved Forest Areas (산림 활엽수 지역의 강우유출수 유출특성 및 EMC 산정)

  • Kang, Chang Guk;Lee, Soyoung;Gorme, Joan Barniso;Lee, Jea Un;Kim, Lee-Hyung
    • Journal of Environmental Impact Assessment
    • /
    • v.18 no.6
    • /
    • pp.393-399
    • /
    • 2009
  • The water of rivers and lakes are affecting by point and nonpoint source pollutions. The point source pollution can be controlled by establishing the treatment plants. However, nonpoint source pollution by various human activities is not easy to be controlled because it is difficult to determine the exits of the water flow and have many exit points. Due to contribution of nonpoint source pollution, the achievement ratio of water quality in rivers and lakes is not high. TMDL is the outstanding water quality control policy because all of the pollutant loadings from the watershed area are counting on the input loads. Our aqua-ecosystem has self-purification process by biological, physical and ecological processes. The self-purification process can remove the pollutant load from background concentrations. Usually forest area is main source of background concentrations. In Korea, about 70% of the national boundary area consists of mountains. This study is conducting as part of long-term monitoring to determine the Event Mean Concentration during a storm. The monitoring was performed on a broad-leaved tree area.

Characteristics of Pollutant Concentrations in Runoff Water from a Small Rural Watershed (농촌 소유역 유출수의 오염물질 농도특성)

  • Oh, Kwang-Young;Kim, Jin-Soo;Cho, Jae-Won
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.49 no.2
    • /
    • pp.99-108
    • /
    • 2007
  • The purpose of this study was to investigate characteristics of concentrations of pollutants such as TN (Total Nitrogen), TP (Total Phosphorus) and COD (Chemical Oxygen Demand) in outflow from a nonpoint source dominated watershed ($6.7km^2$). Regular flow measurement and water sampling were taken at five-day intervals during two years (February 2002 to January 2004) in the Ingyeong River, a tributary of the Han River. The mean concentrations of pollutants during rainy days were significantly (p<0.05) higher than those during dry days. For dry days, the flow-weighted mean concentration (0.06 mg/L) of TP during paddy irrigation periods were higher than that (0.02 mg/L) during non-irrigation periods. The seasonal mean concentration of TN was highest in spring likely due to nitrogen fertilization, but those of TP and COD were highest in summer due to particulate phosphorus and sediment-associated organic matter caused by increased discharge. The pollutant concentrations significantly increased with discharge, suggesting that the measures to reduce the increase in the concentrations during storms are needed to control nonpoint source pollution.

Characteristics of Metal Pollutants and Dynamic EMCs in a Parking Lot and a Bridge during Storms (주차장 및 교량 강우유출수의 중금속 오염물질 특성과 동적 EMCs)

  • Kim, Lee-Hyung;Lee, Seonha
    • Journal of Korean Society on Water Environment
    • /
    • v.21 no.4
    • /
    • pp.385-392
    • /
    • 2005
  • The control of nonpoint source pollution is essentially needed to successfully perform the Total Maximum Daily Load program. Of the various land uses in the nonpoint source, the paved areas such as a parking lot and a bridge are stormwater intensive land uses because of high imperviousness and high pollutant mass emissions. This research was performed to understand the magnitude and nature of the stormwater emissions with the purposes of quantifying stormwater pollutant concentrations and mass emission rates from a parking lot and a bridge. Two monitoring sites in Kongju city were equipped with an automatic rainfall gages and an automatic flow meter for accumulating the data such as rainfall, water quality and runoff flow rates. This paper will summarize the metal concentration changes during the storm duration and metal EMCs to characterize the concentration profiles in a parking lot and a bridge. Also a new concept, dynamic EMC, will be proposed to find the relationship between EMC and first flush effect. It can be used to determine the economical treatment criteria in best management practices.

Estimation of Nonpoint Discharge Coefficient for the Management of Total Maximum Daily Load - Rainfall Discharge Ratio on the Specific Design Flow (수질오염총량관리를 위한 비점배출계수 산정 - 특정 기준유량 시기의 강우배출비)

  • Park, Jundae;Park, Juhyun;Rhew, Doughee;Jeong, Dongil
    • Journal of Korean Society on Water Environment
    • /
    • v.24 no.4
    • /
    • pp.452-457
    • /
    • 2008
  • Nonpoint source (NPS) pollution is caused by rainfall moving over and through the ground. As the runoff moves, it picks up and carries away various pollutants from NPS. The discharge pattern of NPS pollutant loads is affected by the distribution of the rainfall during the year. This study analysed relationship between the rainfall event and the stream flow rate, and estimated the rainfall discharge ratio on the specific design flow which can be used as nonpoint discharge coefficient for the estimation of NPS pollution load. It is considered that nonpoint discharge coefficient can be effectively used for the calculation of NPS pollution load at the time of water quality modelling for the management of Total maximum daily load (TMDL).