• Title/Summary/Keyword: Runoff Load

Search Result 288, Processing Time 0.021 seconds

PREDICTION OF COMBINED SEWER OVERFLOWS CHARACTERIZED BY RUNOFF

  • Seo, Jeong-Mi;Cho, Yong-Kyun;Yu, Myong-Jin;Ahn, Seoung-Koo;Kim, Hyun-Ook
    • Environmental Engineering Research
    • /
    • v.10 no.2
    • /
    • pp.62-70
    • /
    • 2005
  • Pollution loading of Combined Sewer Overflows (CSOs) is frequently over the capacity of a wastewater treatment plant (WWTP) receiving the water. The objectives of this study are to investigate water quality of CSOs in Anmyun-ueup, Tean province and to apply Storm Water Management Model to predict flow rate and water quality of the CSOs. The capacity of a local WWTP was also estimated according to rainfall duration and intensity. Eleven water quality parameters were analyzed to characterize overflows. SWMM model was applied to predict the flow rate and pollutant load of CSOs during rain event. Overall, profile of the flow and pollutant load predicted by the model well followed the observed data. Based on model prediction and observed data, CSOs frequently occurs in the study area, even with light precipitation or short rainfall duration. Model analysis also indicated that the local WWTP’s capacity was short to cover the CSOs.

Basic Monitoring Concept for Revised Unit Load on NPS (비점오염원 원단위 개정을 위한 조사연구 방향)

  • Shin, Dongseok
    • Journal of Korean Society on Water Environment
    • /
    • v.23 no.4
    • /
    • pp.429-433
    • /
    • 2007
  • Many researchers have made a study of NPS unit-loads and the scientific evaluation method which need for formulating and enforcing a Total Maximum Daily Load (TMDL) management system and modifying a pollutant discharge loadings function. Some showed the event mean concentration (EMC) on single land-use. For the most parts, as the results showed on multiple land-uses, those cannot be used for NPS unit-loads calculation. NPS runoff shows various phenomena depending on rainfall monitoring data, therefore sampling methods and frequency for NPS monitoring must be different from the general monitoring for water quality trend assessment.

Comparison of Characteristics of Suspended Matters in Streams by Dry/Rainy season and Watershed Characteristics (비강우/강우기와 유역특성에 따른 하천의 부유물질 성상별 유출 특성 비교)

  • Park, Jihyoung;Sohn, Sumin
    • Journal of Korean Society on Water Environment
    • /
    • v.29 no.6
    • /
    • pp.739-745
    • /
    • 2013
  • This paper investigated the runoff characteristics of different properties of suspended solids in streams according to the watershed characteristics and dry/rainy season. Suspended solids were divided into VSS and NVSS depending on volatilization. The main results of this study were as follows. TSS were more correlated with NVSS than VSS. Suspended solids were positively related with the proportion of urban > paddy > upland, negatively related with forest cover. VSS were positively correlated with POP and POC. VSS, measured in dry season, would partly result from autochthonous production and could be an indirect indicator of organic suspended solids.

Estimation of Suspended Sediment Load in Imha-Andong Watershed using SWAT Model (SWAT 모델을 이용한 임하.안동 유역의 부유사량 발생량 추정)

  • Kim, Jeong-Kon;Son, Kyong-Ho;Noh, Joon-Woo;Lee, Sang-Uk
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.30 no.12
    • /
    • pp.1209-1217
    • /
    • 2008
  • For efficient turbid water management a SWAT model was established for the Imha-Andong watershed where serious turbid water problems have frequently occurred. To evaluate soil loss combined with rainfall runoff process, the analysis focused on comparing the daily runoff discharge and concentration of suspended sediment (SS) using measured data sets. The results of annual SS load analysis for each sub-basin using the calibrated model showed that in the entire target watershed the soil loss ranged from 0.7 to 5.9 tons/ha in year 2005 and from 3.0 to 34.0 tons/ha in year 2003 when the typhoon 'Maemi' severly affected the area. In the future, it is suggest to increase model simulation accuracies supported by a long-term and extensive monitoring to enhance basin-wide suspended sediment estimation and management.

Characteristics of Agricultural Non-point Source Pollutants by Rainfall Events in Rural Watersheds (농촌유역의 강우사상별 농업 비점원오염물질 유출특성)

  • Kim, Jinho;Han, Kukheon;Lee, Jongsik
    • Journal of Korean Society on Water Environment
    • /
    • v.24 no.1
    • /
    • pp.69-77
    • /
    • 2008
  • This study was conducted to know the characteristics of agricultural non-point source pollutants runoff by rainfall events at the upper catchment of Goseong reservoir in Gonjy city, Chungnam Province. For this study, the monitoring sites of the research catchment were set nineteen during the research period (between June 2005 and October 2006). Average runoff coefficient were observed 0.51 in 2005, 0.71 in 2006, respectively. The correlation coefficient (r) between the rainfall and peak-flow was investigated 0.787. By rainfall events, the water quality of the sites were shown like this : BOD 0.555~9.60 mg/L, T-N 0.01~13.50 mg/L, T-P 0.002~2.952 mg/L, and SS N.D~820.0 mg/L. The strong rainfall intensity was the most important factor of the soil erosion. The gabs of the arithmetic mean concentrations and the flow weighted mean concentrations were observed as the followings : BOD 0.0~29.2%, T-N 0.1~11.4%, T-P 0.4~95.2%, and SS 1.7~57.0% in 2005, and BOD 1.0~11.9%, T-N 0.7~7.3%, T-P 9.9~36.5%, and SS 6.6~36.5% in 2006, respectively. The BOD pollution load was 2,117 kg (36% of the total BOD loading of survey periods) while, T-N was 3,209.0 kg (27.9% of the total T-N loading of survey periods), T-P was 136.4 kg (37.4% of the total T-P loading of survey periods) and SS was 72,733.8 kg (51.8% of the total SS loading of survey periods) in the year 2005. In case of 2006, BOD load was 1,321.7, T-N was 2,845.8, T-P was 42.9, and SS was 16,275.8 kg, respectively.

Effect and Control of the Sediment in the Combined Sewer on CSOs (합류식 하수관거내 퇴적물이 CSOs에 미치는 영향 및 제어방안)

  • Lim, Bongsu;Kim, Doyoung;Lee, Kuangchun
    • Journal of Korean Society on Water Environment
    • /
    • v.27 no.1
    • /
    • pp.36-43
    • /
    • 2011
  • This study is selected two points of combined sewer that occurred Fish Kill after first flush, that analyzed generation of pollutants and stream runoff generation of combined sewer overflows (CSOs) as fine weather and rainfall. In addition, this study was to analyze the relationship between CSOs and sediments, to propose measures to reduce the sediment relevant with CSOs and rainfall runoff from entering sewage treatment plants and measures for discharged directly into streams when indicate relatively good water quality after overflow. Sediments in combined sewer system was discharged about 50~80% as overflows during rainfall and we can reduce the amount of the CSOs at least 50% or more if the sewer does not exist in the sediments because of the amount of discharge about the amount of intercept has been investigated by 3~5 times. Because of velocity at sediment interval in sewer is very low, sewage velocity of about 3~5 times as much as it can increase the amount of sediment can be reduced if the separation wall is installed. Effective control of BOD overflow load is respectively 77.5%, 75.8% at first point, second point by the separation wall is installed. Drainage area greater than area in this study or many combined sewer overflows region is increased the more effective control of separation wall. Turbidity to measure changes in water quality of overflows can be used as an factor to control the intercept flows because the intercept flows(3Q) after the first flush has lowered removal efficiency and increases the operational load of sewage treatment plants. Sewage water quality after a overflow when the reasonable turbidity was measured at this point flows to excluded intercept flow(1Q) can be discharged to stream.

Analysis of Nonpoint source Reduction at Andong Area Considering Changes in CN (CN의 변화에 따른 안동시 물순환 선도도시 조성계획의 비점오염부하 저감효과 분석)

  • Kwon, Heongak;Jung, Kangyoung;Kim, Shin;Shin, Sukho;Ahn, Jungmin;Kim, Gyeonghoon
    • Journal of Wetlands Research
    • /
    • v.18 no.4
    • /
    • pp.342-349
    • /
    • 2016
  • Andong belongs to the Nakdong River Basin, Nakdong River is flowing through the city, including Andong dam and Imha dam. The runoff due to provincial transfer and impervious area has been increasing by urbanization increases and nonpoint source loads. In this study, we evaluate the runoff and nonpoint pollution loads in accordance with the development targeted at selected urban water cycle leading to Andong city. Andong city leading to the water cycle plan to evaluate the directly runoff and BOD, T-N and T-P nonpoint pollutant loads using the CN into account the temporal and spatial changes. Evaluation, direct runoff per year is 10.41 % if the green roof and a water permeable pavement replacement, water cycle parks and streets compositions, City impermeable layer improvements to be business including four kinds of scenario is applied to both the development and the BOD non-point pollutant loads 20.56%, T-N 9.55% and T-P pollution and nonpoint loads was investigated to be reduced 14.29%. Four kinds of low lapse rate of the development scenario of the highest thing urban impervious surface was investigated by improving business development prior year annual direct runoff is 6.25 %, BOD nonpoint pollution loads are 11.84%, T-N nonpoint pollution loads are 4.46 % and T-P was investigated by reducing pollutant loads to be 10.20%.

Spatial Distribution of Bacterial Abundance and Production in the Saemangeum Area (새만금 주변 해역에서 박테리아 개체수 및 생산력의 공간 분포)

  • Choi, Dong-Han;Noh, Jae-Hoon
    • Ocean and Polar Research
    • /
    • v.30 no.4
    • /
    • pp.509-518
    • /
    • 2008
  • Distribution of bacterial abundance and production was investigated in seawater around Saemangeum dike 7 times during March, $2007{\sim}July$, 2008. In the inner area of the dike, salinity variation was great due to river runoff from Mangyung and Dongjin Rivers and high chlorophyll a (chl a) concentrations up to $124.3{\mu}g\;l^{-1}$ was found. In the outer area of the dike, salinity was higher than in the inner area of the dike, and chl a was lower up to 10 times than in the inner area of the dike. Thus, the area of Saemangeum showed meso- to hypereutrophic conditions. Bacterial abundance and production ranged from 0.3 to $4.3{\times}10^9\;cells\;l^{-1}$ and from 5.2 to $570 pmol\;l^{-1}h^{-1}$ in outer area of the dike, respectively, while in the inner area of the dike bacterial abundance and production was 3 to 4 times higher ($0.4{\sim}12.7{\times}10^9\;cells\;l^{-1}$ and $12.3{\sim}1309\;pmol\;l^{-1}h^{-1}$, respectively) than those in the outer area. In both areas, bacterial abudance and production was highest in summer and lowest in winter. However, the variations of bacterial parameters was very large in each season. These large variations seemed to be related with the supply of organic matter. Bacterial abundance and production showed significant negative correlations with salinity in the inner area, suggesting that allochthonous organic matter input by river runoff could be an important factor in regulating the distribution of bacterial abundance and production. In addition, bacterial production also correlated positively with chl a in the inner area, suggesting that autochthonous substrate might be another regulating factor of bacterial growth in the area. These results suggest that the supply of both allochthonous organic substrates introduced by river runoff and autochthonous substrates produced by phytoplankon could be important in regulating bacterial growth and utilization of organic matter in the area. Thus, to manage water quality in the inner area of dike, it seems to be important to lower the load of both organic and inorganic nutrients from adjacent rivers.

Characteristics of Non-point Source Pollutants Runoff from Agricultural and Industrial Areas in Lake Sihwa Watershed (강우시 시화호 농촌 및 공단유역의 비점오염물질 유출특성)

  • Kim, Sea-won;Choi, Kwangsoon;Kim, Dong-sup;Lee, Mikyung
    • Journal of Korean Society on Water Environment
    • /
    • v.25 no.5
    • /
    • pp.768-777
    • /
    • 2009
  • The characteristics of stormwater runoff was examined on distinct types of agricultural and industrial area in Lake Sihwa watershed. During rainfall event, the peak concentrations of SS, $COD_{Mn}$, and TP were observed after 6~11 hours of rainfall in agricultural areas. Whereas, the peak concentrations occurred within the first one hour after rainfall and then the highest concentration of NPS pollutants sharply decreased, showing strong first flush effect in industrial areas. The strong first flush effect of suspended solid was apparent in agricultural areas, while those of organic matters and nutrients were clear in industrial areas. The cumulative load curves for NPS pollutants showed above the $45^{\circ}$ straight line, indicating that first flush effect occurred in industrial areas. The mean SS EMC values of agricultural areas ranged from 60~598 mg/L (Avg. 285 mg/L), it was higher value when compare to other areas. While the mean $COD_{Mn}$, TN, and TP EMCs values of industrial areas were shown the highest values as 67.7 mg/L, 12.1 mg/L and 2.1 mg/L respectively.

The Variation of Water Quality due to Sulice Gate Operation in Shiwha Lake (시화호의 배수갑문 운용에 따른 수질변화)

  • 김종구;김준우;조은일
    • Journal of Environmental Science International
    • /
    • v.11 no.12
    • /
    • pp.1205-1215
    • /
    • 2002
  • To evaluate the change for water quality after the water gate operation in Shiwha lake, in situ survey were conducted on september in 2000 and January, march, jane in 2001. Chemical characteristics and eutrophication level was estimated from the survey data. The water quality of the Shihwa lake was greatly affected by pollutant load from rainfall, and formation of stratification in summer and winter was increased to effect on nutrient release from sediment. Especially, high concentration of chlorophyll-a was occurred in autumn, due to increased nutrient, high water temperature and low salinity after rainfall runoff. The mean concentration of DIN, DIP were 0.346mg/L, 0.0217mg/L in surface water and 0.826mg/L, 0.0415mg/L in bottom water, respectively, which were over III grade of seawater standard. Also high percentage of ammonia nitrogen to DIN in bottom water for autumn and winter was affected by released nutrient from sediment. Correlation analysis of chlorophyll-a versus TSS was shown that organic matter was affected by autochthonous organic matter stem from the algae, these factor showed reverse correlation about salinity. Closely correlations among to the water quality constituent in continuity survey was appeared. The results of eutrophication index estimation showed the high potentiality of red tide occurrence in Shiwha lake, particularity in summer or fall. Overall water quality was greatly improve to compared with measuring data during 1997~1998 at the beginning water gate operation, which reported by KORDI. Therefore, to improve of water quality in Shiwha lake, we need to establish of management plan about nutrient release from sediment, rainfall runoff, maximum of seawater exchange.