• Title/Summary/Keyword: Rubber ball

Search Result 62, Processing Time 0.017 seconds

Rhinoplasty using Various Autogenous Tissues (다양한 자가조직을 활용한 비성형술)

  • Han, Ki-Hwan;Yeo, Hyeon-Jung;Choi, Tae-Hyun;Kim, Jun-Hyung;Son, Dae-Gu
    • Archives of Plastic Surgery
    • /
    • v.37 no.1
    • /
    • pp.37-45
    • /
    • 2010
  • Purpose: In Korean rhinoplasty, alloplasts such as silicone rubber have been used for dorsal and tip augmentations. However, alloplasts have produced complications such as deviation, exposure, and infection. Although autogenous tissue is an ideal material, the amount of the cartilage in Korean is not sufficient. Therefore, the authors developed a method to harvest the maximum amount of the septal and conchal cartilage. The authors first performed a complete septal extension graft for short and retruded columella and then performed nasal augmentation using various autogenous tissues. Methods: These surgical techniques were performed on 11 patients. Their average age was 27 years. An open approach with a V-shaped columellar labial incision was performed. At first, the complete septal extension graft was fixed on the entire caudal margin of the septum, and the alar cartilage was suspended to the septal extension graft to make the tip projected and the columella advanced caudally. A temporal fascial ball was used for radix augmentation. For dorsal augmentation, a batten-shaped septal cartilage graft wrapped with or without the temporal fascia or a diced cartilage graft wrapped with the temporal fascia was performed. For nasal tip augmentation, a shield graft and a cap graft or a folded conchal cartilage graft was performed.Results: The mean follow-up period was 11.2 months. The overall results were natural and satisfactory. Two patients underwent slight absorption and caudal displacement. With the exception of these cases, no complications were observed. Conclusion: Korean rhinoplastic surgeons are accustomed to using the alloplasts despite of serious complications. When rhinoplasty using autogenous tissue was performed, some complications occurred such as the displacement of the diced cartilage graft wrapped with the fascia, but many of the complications of alloplastic rhinoplasty were avoided. Therefore, we propose that by this time Korean rhinoplastic surgeons need to change their preference from alloplastic rhinoplasty to autogenous rhinoplasty.

Case study on frequency bands contributing the single number quantity for heavy-weight impact sound based on assessment method changes (중량충격음 평가방법 변화에 따른 단일수치평가량 기여 주파수 대역 사례 분석)

  • Hye-kyung Shin;Sang Hee Park;Kyoung-woo Kim
    • The Journal of the Acoustical Society of Korea
    • /
    • v.42 no.6
    • /
    • pp.565-571
    • /
    • 2023
  • With the introduction of the post-verification system, the measurement of floor impact noise performance on-site has become mandatory, and the evaluation method has changed. To track the performance changes since the policy implementation, research is needed on how the characteristics of heavyweight impact sound change according to the varied evaluation method. In this study, we analyzed the contribution rate of the frequency band-specific sound pressure level on the single-number quantity for a multi-family housing unit with the same floor plan and floor structure, comprising 59 households, based on the changed impact sources and evaluation indicators. It is difficult to compare simply because the method of calculating contributions by frequency band according to the single-day evaluation is different, but the average contribution rate of 63 Hz was 80.8 % in the evaluation method before the introduction of the post-confirmation system (Tire measurement and evaluated as L'i,Fmax,AW), and the average contribution rate of 125 Hz was 19.2 %. The current evaluation method (rubber ball measurement and evaluation as L'iA,Fmax) shows that the contribution rate has decreased to 33.1 % on average at 50 Hz ~ 80 Hz, 58.7 % on average at 100 Hz ~ 160 Hz, 6.9 % on average at 200 Hz ~ 315 Hz, and 1.3 % on average at 400 Hz ~ 630 Hz. This result is a case analysis for the target apartment house, and it is necessary to analyze measurement data for more diverse apartment houses.