• Title/Summary/Keyword: Rubber Pressure

Search Result 332, Processing Time 0.023 seconds

The Study on the Pressure-Sensitive Adhesion Property of Waste FKM Powder and SBS Modified Asphalt (폐불소고무 분말과 SBS로 개질된 아스팔트의 점착 특성에 관한 연구)

  • Chung, Kyung-Ho;Kang, Min-Kyu;Han, Kyung-A
    • Elastomers and Composites
    • /
    • v.44 no.3
    • /
    • pp.282-289
    • /
    • 2009
  • The pressure-sensitive adhesive(PSA) tapes are widely used as floor-sealing material in Korean constructive industry. However, the general PSA tapes can not seal the apertures completely. This is one of main reasons to cause imperfect finishing. In order to solve the problems, the asphalts were modified by FKM powder and SBS in this study. The physical properties of modified asphalts were examined by measuring the softening point, viscosity, tensile strength and adhesion strength of FKM and SBS modified asphalt. The softening point of SBS modified asphalt was increased greatly due to the formation of network structure in asphalt. Also, the change of adhesion strength of SBS modified asphalt with temperature was not so great comparing to those of pure asphalt and FKM modified asphalt. The best results of pressure-sensitive adhesion could be obtained by the SBS(linear) modified asphalt containing 6 wt.% of linear type SBS.

Implantable Flexible Sensor for Telemetrical Real-Time Blood Pressure Monitoring using Polymer/Metal Multilayer Processing Technique (폴리머/ 금속 다층 공정 기술을 이용한 실시간 혈압 모니터링을 위한 유연한 생체 삽입형 센서)

  • Lim Chang-Hyun;Kim Yong-Jun;Yoon Young-Ro;Yoon Hyoung-Ro;Shin Tae-Min
    • Journal of Biomedical Engineering Research
    • /
    • v.25 no.6
    • /
    • pp.599-604
    • /
    • 2004
  • Implantable flexible sensor using polymer/metal multilayer processing technique for telemetrical real-time blood pressure monitoring is presented. The realized sensor is mechanically flexible, which can be less invasively implanted and attached on the outside of blood vessel to monitor the variation of blood pressure. Therefore, unlike conventional detecting methods which install sensor on the inside of vessel, the suggested monitoring method can monitor the relative blood pressure without injuring blood vessel. The major factor of sudden death of adults is a disease of artery like angina pectoris and myocardial infarction. A disease of circulatory system resulted from vessel occlusion by plaque can be preventable and treatable early through continuous blood pressure monitoring. The procedure of suggested new method for monitoring variation of blood pressure is as follows. First, integrated sensor is attached to the outer wall of blood vessel. Second, it detects mechanical contraction and expansion of blood vessel. And then, reader antenna recognizes it using telemetrical method as the relative variation of blood pressure. There are not any active devices in the sensor system; therefore, the transmission of energy and signal depends on the principle of mutual inductance between internal antenna of LC resonator and external antenna of reader. To confirm the feasibility of the sensing mechanism, in vitro experiment using silicone rubber tubing and blood is practiced. First of all, pressure is applied to the silicone tubing which is filled by blood. Then the shift of resonant frequency with the change of applied pressure is measured. The frequency of 2.4 MHz is varied while the applied pressure is changed from 0 to 213.3 kPa. Therefore, the sensitivity of implantable blood pressure is 11.25 kHz/kPa.

A Study on Complement of the Design and Analysis Procedures of Friction Pendulum System (마찰진자형 면진받침의 설계 및 해석절차 보완에 관한 연구)

  • Kim, Hyun-Uk;Joo, Kwang-Ho;Noh, Sang-Hoon;Song, Jong-Keol
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.1
    • /
    • pp.488-494
    • /
    • 2014
  • Although friction pendulum system has various advantages it is difficult to estimate the behavior because of velocity, bearing pressure, and temperature dependent characteristics of coefficient of friction. This research focuses on evaluating the conservatism of each method used and the effects of bearing pressure on the behavior of the system by conducting comprehensive examination on design and analytic procedure of friction pendulum system, as is proposed in standard, code and literature. In addition, this study provides comparative analysis on general behavior characteristics of friction pendulum system by comparing the result with that of the analysis on lead rubber bearing which possesses the same dynamic properties.

An experimental study for water tightness of segment under high water pressure (고수압 조건에서의 세그먼트 방수성능평가에 대한 실험적 연구)

  • Choo, Seok-Yean;Park, Young-Jin;Kim, Dong-Hyun;Kim, Yong-Il;Lee, Du-Wha;Cho, Sang-Kook
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.5 no.4
    • /
    • pp.361-370
    • /
    • 2003
  • In this study, the performance of water tightness of water expansional sealing material and gasket was evaluated. The water tightness test was performed varying the type of inner pressure condition, for which the water expansional sealing material was inundated for 5 days to evaluate the ability of water tightness. In order to carry out this test, we made use of two types of water expansional sealing material; general type and combined type with non-expansional rubber. In the case of gasket, EPDM gasket and complex gasket sticked to the water expansional sealing material were applied. The performance of water tightness depended on the construction defect and the deformation of segment. The construction defect and segment deformation were generally expressed by gap and offset of the construction joint. The results, of tests showed that the performance of water tightness was largely influenced by the gap between segments. Management criteria of gap and offset were proposed.

  • PDF

Performance Characteristics with Various Fuel Composition and Temperature for an External Type Fuel Pump in LPLi System (LPLi 시스템에서 외장형 펌프의 연료조성 및 온도에 따른 성능특성 연구)

  • Nam, Deok-Woo;Yoon, Jun-Kyu;Lim, Jong-Han
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.35 no.5
    • /
    • pp.566-575
    • /
    • 2011
  • Since LPG (Liquefied petroleum gas) fuel supply system has an advantage of low emission characteristics, many studies have been conducted. In spite of the advantage of LPG supply system, a higher vapor pressure and lower viscosity than diesel or gasoline fuel may cause unstable running of fuel pump by the deterioration in lubrication performance and chemical reaction with rubber parts than that of diesel and gasoline fuel. Therefore its physical properties can cause the deterioration of durability. In this research, we developed an external type LPG pump which has the advantage of the price competitiveness and the convenient maintenance for LPLi system. The experiments were carried out in order to assess characteristics of the external type fuel pump at different fuel composition and temperature. As a result, there aren't any differences between internal and external type pump performance. It is observed that the same level of efficiency was maintained for both pumps as flow rate was increased with higher fuel temperature and more contents of propane in the fuel. And the pressure difference in LPLi system is maintained at constant with the various fuel compositions and temperatures due to their own characteristics of fuel supply system.

Assessment of Underwater Penetration Performance for the Shape of the External Device of Shaped Charge (성형폭약 외부장치 형상에 따른 수중 관입성능 평가)

  • Suk, Chul-Gi;Noh, You-Song;Ko, Young-Hun;Park, Hoon;Cho, Sang-Ho;Yang, Hyung-Sik
    • Explosives and Blasting
    • /
    • v.34 no.4
    • /
    • pp.1-9
    • /
    • 2016
  • For underwater steel structure, cut that underwater shaped charge device that combines a spring hose, which is an external device of pressure resistance and flexibility with flexible shaped charge, was invented. As a basic experiment for an optimum condition design, an penetration performance was compared by external device shape. To evaluate the result of an experiment, image analysis was carried out after obtaining the model by using the liquid rubber for the penetrated steel plate. To simulate the penetrating process of shaped charge, the AUTODYN program has been used. As a result of analysis, while the average penetration depth of circular and square shaped external devices were similar, the penetration quality was more uniform in the case of circle. In addition, water infiltration occurred in square case, displacement and strain rate according to the increase of the water pressure were measured high.

Development of a Water-Spraying Type Automatic Glochids Removal System for Cactus (Opuntia humifusa) Stem

  • Jang, Ik Joo;Park, Tusan;Ha, Yu Shin
    • Journal of Biosystems Engineering
    • /
    • v.41 no.3
    • /
    • pp.201-207
    • /
    • 2016
  • Purpose: A water-spraying type automatic glochids removal system for cactus (Opuntia humifusa) stem was developed, and its performance was evaluated. The system was developed to reduce intensive human labor in removing glochids from cactus stem skin without inducing damage prior to further processing into value-added products. Methods: The developed system consists of conveyor and water-spraying systems. The conveyor system delivers cactus stems through water-spraying compartments and finally to a collecting box. In order to remove the glochids, rotating nozzles spray water over all areas (i.e., front and back faces and sides) of the cactus skin under controlled water pressure. Operating conditions such as conveyor speed, water pressure, angle of water-spraying nozzles, distance between conveyor belt and rotating nozzles, and angle of cactus flipping slide were adopted from our previous study and applied on the system design and manufacturing. The performance of glochids removal was evaluated by counting the number of glochids on the cactus stem before and after processing on the system. Results: The developed system performed efficiently and effectively under the pre-studied operating conditions except for the angle of cactus flipping slide. The new system had a glochids removal ratio of 94.1% without damaging the cactus skin. Considering the original number (approximately 30-60) of glochids, the remaining number was low (1-4), and most of them were found at the side edge of the cactus stem. This system can remove glochids from 360 cactus stems in 1 hr regardless of cactus size. Conclusions: The performance of the new system in glochids removal without damaging cactus skin is superior to any other existing device (i.e., brush type, rubber-friction type, and agitation type). The system is expected to be applied in cactus (O. humifusa) processing facilities.

Pressure Sensitive Adhesive Properties of Blends of Acrylic Quarternary Copolymer with Vinyl Chloride-Vinyl Propionate Copolymers (아크릴계 4원 공중합체와 염화비닐-비닐프로피오네이트 공중합체와의 블렌드의 점착물성)

  • Oh, Dae-Hee;Seo, Kwan-Ho
    • Elastomers and Composites
    • /
    • v.34 no.4
    • /
    • pp.360-365
    • /
    • 1999
  • In this study, the blends of acrylic quaternary polymer (PEBEV) which was co- polymerized from 2-ethylhexyl acrylate (2-EHA), n-butyl acrylate (BA) and ethyl acrylate (EA), vinyl acetate (VAc), and poly(vinyl chloride-co-vinyl propionate) (PVCVP) were prepared by solution blending. Pressure sensitive adhesive (PSA) properties of PEBEV/PVCVP blends were compared with those of PEBEV/poly(vinyl chloride-co-vinyl acetate) (PVCVAc) blends. Compatibility of PEBEV/PVCVP was better than that of PEBEV/PVCVAc. Tackiness of both blend systems were similar, but holding power began to decrease at 15wt% or higher PVCVAc contents in PEBEV/PVCVAc blends. On the other hands, holding power of PEBEV/PVCVP increased as the contents of PVCVP increased. Failure modes of the blends were adhesive failure except 5wt% of PVCVP was blended.

  • PDF

Numerical Analysis and Optimum Design of Disposable Drug Infuser Using Fluid-Structure Interaction Technique (유체-구조 상호작용기법을 이용한 일회용 약물주입기의 성능 해석 및 최적 설계)

  • Kim, Heon-Young;Kim, Hak-Jin
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.34 no.11
    • /
    • pp.1595-1602
    • /
    • 2010
  • A disposable drug infuser is used to provide drugs to patients who are not hospitalized; in this infuser, an elastic recovery force is exerted by a diaphragm made of a rubber-like materialsuch that a constant amount of drugs is provided to a patient. The drug infuser has to control the speed and amount of drugs to be released, as well as the overall duration for which they are to be administered. However, in a drug infuser with an elastic diaphragm, the infusion pressure depends on the amount of drug remaining within the infuser, and the amount of drug infused gradually decreases as the amount remaining in the infuser decreases. In this study, a finite element procedure involving the application of the fluid-structure interaction technique was developed and the performance of the elastic type disposable drug infuser was analyzed. The optimum design for ensuring that the infusion pressure remains constant throughout the duration of usage, including during infusion and discharge, was determined by this procedure.

Mechanically Induced Long Period Fiber Grating Array Device and Sensor Application (기계적으로 유도되는 장주기 광섬유 격자 배열 소자 및 센서 응용)

  • Lee, Nam-Kwon;Song, Jae-Won;Park, Jea-Hee
    • Korean Journal of Optics and Photonics
    • /
    • v.18 no.2
    • /
    • pp.142-148
    • /
    • 2007
  • A mechanically induced long-period fiber grating array was fabricated and its transmission characteristics were measured. The grating away consisted of a rubber cover and a 45 cm metal bar with 10 grating groups. Each grating group was composed of 60 gratings. The period of the grating of the grating groups was increased by $10{\mu}m$ increments from $690{\mu}m$ to $780{\mu}m$. The long period fiber grating was induced when the pressure was applied on the long period grating array and the resonant wavelength depended on the position of applied pressure. The experimental results shows that this long period fiber grating away can be used as a various band rejection filter or a fiber optic sensor.