• 제목/요약/키워드: Routine release

검색결과 20건 처리시간 0.022초

Comparison of Off-site Radiological Dose Due to the Routine Release of Gaseous Radioactive Effluents Based on the Korean and Japanese Regulatory Recommendations

  • Hwang, Won Tae;Kim, Chang Lak;Lee, Cheol-Woo;Han, Moon Hee
    • Journal of Radiation Protection and Research
    • /
    • 제44권4호
    • /
    • pp.161-165
    • /
    • 2019
  • Background: Not only regulatory framework including radiation protection quantities and regulatory standards, but also methodology for regulatory compliance may be different in each country due to inherent philosophy for radiation protection. Materials and Methods: Based on the Korean regulatory models, off-site radiological dose resulting from the routine releases of gaseous radioactive effluents was calculated by applying the parameter values and assumptions recommended in the Korean and Japanese regulations. Results and Discussion: Effective dose for adult based on the Korean recommendation were 17.5 and 1.6 times higher than those of Japanese recommendation for 131I and 133I, respectively, for the same atmosphere dispersion and ground deposition factors. Conclusion: It was due to different parameter values and assumptions recommended for the purpose of evaluating compliance with dose criteria for the radiation protection of the public in each country.

식품의 안전성면역에서 본 농약의 면역독성에 관하여 (Immunotoxicological Aspects of Pesticides)

  • 문창규
    • 한국식품위생안전성학회지
    • /
    • 제1권1호
    • /
    • pp.97-106
    • /
    • 1986
  • Pesticides constitute a unique group of biologically active chemicals in that they are produced for deliberate release into the environment, usually to produce some specific biocidal effect. Workers at all stages of pesticide production and application become exposed, at least on an occasional basis, while some experience routine exposure. The general population is, in turn, exposed to the residues, in air, water and food. This review is intended to survey the present knowledge of the immunotoxicity of 20 pesticides. As will be readily seen, knowledge of pesticide immunotoxicology to date is largely descriptive with only modest beginnings toward understanding mechanisms underlying the effects. In most cases the effects have not yet to be defined in immunological state, and just as little is presently known about how these chemicals exert their effects. There is an equally great gap in perceiving any relationship between the structure of a chemical and immunotoxicological potential.

  • PDF

Development of a Simplified Statistical Methodology for Nuclear Fuel Rod Internal Pressure Calculation

  • Kim, Kyu-Tae;Kim, Oh-Hwan
    • Nuclear Engineering and Technology
    • /
    • 제31권3호
    • /
    • pp.257-266
    • /
    • 1999
  • A simplified statistical methodology is developed in order to both reduce over-conservatism of deterministic methodologies employed for PWR fuel rod internal pressure (RIP) calculation and simplify the complicated calculation procedure of the widely used statistical methodology which employs the response surface method and Monte Carlo simulation. The simplified statistical methodology employs the system moment method with a deterministic approach in determining the maximum variance of RIP The maximum RIP variance is determined with the square sum of each maximum value of a mean RIP value times a RIP sensitivity factor for all input variables considered. This approach makes this simplified statistical methodology much more efficient in the routine reload core design analysis since it eliminates the numerous calculations required for the power history-dependent RIP variance determination. This simplified statistical methodology is shown to be more conservative in generating RIP distribution than the widely used statistical methodology. Comparison of the significances of each input variable to RIP indicates that fission gas release model is the most significant input variable.

  • PDF

KIVA3V와 SWEEP을 이용한 디젤 엔진에서의 soot 총량 및 입자 크기 분포 예측 (Prediction of Soot Emissions and Particle Size distribution by KIVA3V and SWEEP in a diesel engine)

  • 이재서;허강열
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 2012년도 제45회 KOSCO SYMPOSIUM 초록집
    • /
    • pp.129-132
    • /
    • 2012
  • Computation is performed to predict number density, volume fraction and size distribution of soot particles in typical operating conditions of a diesel engine. KIVA has been integrated with the CMC routine to consider turbulence/chemistry coupling and gas phase kinetics for heat release and soot precursors. The compositions of soot precursors are estimated by tracking Lagrangian particles to consider spatial inhomogeneity and differential diffusion in KIVA. The soot simulator SWEEP is employed as a postprocessing step to calculate conditional and integral quantities of soot particles.

  • PDF

Diagnosis and Treatment of Latent Tuberculosis Infection in Healthcare Workers

  • Mok, Jeong Ha
    • Tuberculosis and Respiratory Diseases
    • /
    • 제79권3호
    • /
    • pp.127-133
    • /
    • 2016
  • Tuberculosis (TB) is one of the most important occupational risks for healthcare workers (HCWs) in South Korea. Many policies regarding the control and prevention of TB in healthcare settings recommend that HCWs are tested for latent tuberculosis infection (LTBI) in addition to active TB. Moreover, the Korean Tuberculosis Prevention Act also recommends that HCWs receive regular testing for LTBI. However, there are no specific or detailed guidelines for dealing with LTBI in HCWs. Herein, we discuss the diagnosis and treatment of LTBI in HCWs and focus particularly on the baseline screening of hired HCWs, routine follow-up, and contact investigation.

Endoscopic Release of Carpal Tunnel Syndrome; Temporal Correlation between Symptomatic and Electrophysiologicallmprovements in Postoperative Carpal Tunnel Syndrome

  • Park, Jin-Soo;Yoo, Chan-Jong;Chun, Young-Il;Kim, Woo-Kyung;Lee, Sang-Gu;Park, Cheol-Wan
    • Journal of Korean Neurosurgical Society
    • /
    • 제37권1호
    • /
    • pp.8-15
    • /
    • 2005
  • Objective: We evaluate temporal correlations between postoperative symptomatic and electrophysiological improvements, and assessed the recovery time required for patients with carpal tunnel syndrome(CTS) before returning to routine activities. Methods: 30 CTS patients were treated via the endoscopic monoportal approach, from March 2001 to September 2003. We assessed the symptoms (hyperesthesia in the finger tips, or abnormal sensations and painful numbness or night pain) and electrophysiological changes in the preoperative state, 1 month and 6 months after surgery. We marked the times at which patients became able to return to activities of daily living and work, after undergoing endoscopic carpal tunnel release. Results: At the end of the follow-up period, high levels of achievement and good outcomes were observed, with respect to both the symptoms and electrophysiological studies. We discovered significant differences between the preoperative and postoperative periods, especially in terms of motor nerve onset latency from $4.50{\pm}1.43$ to $3.97{\pm}0.69$ and sensory nerve conduction velocity, the wrist-to-finger from $19.81{\pm}10.03$ to $28.18{\pm}11.01$ and wrist-to-palm from $23.34{\pm}13.40$ to $31.79{\pm}13.38$(P<0.05 for each comparison). The average time interval required before return to activities of daily living was 26.4 days, and time interval required before return to work was 48.08 days. Conclusion: Electrophysiological improvements are largely consistent with symptomatic relief, but there is some disparity between electrophysiological and symptomatic improvement.

Factors Associated with Indeterminate and False Negative Results of QuantiFERON-TB Gold In-Tube Test in Active Tuberculosis

  • Cho, Ki-Won;Cho, Eun-Ha;Kwon, Soo-Hoon;Im, Sang-Hyuk;Sohn, In;Song, Sook-Hee;Kim, Hye-Ok;Kim, Su-Hyun
    • Tuberculosis and Respiratory Diseases
    • /
    • 제72권5호
    • /
    • pp.416-425
    • /
    • 2012
  • Background: The sensitivities and specificities of interferon-gamma release assays (IGRAs) vary among different population studies, and the data on the routine use of IGRAs are limited. The aim of this study was to evaluate the role of QuantiFERON-TB Gold In-Tube (QFT-GIT) test in the diagnosis of active tuberculosis. Methods: We conducted a prospective study, enrolling 77 patients with suspected pulmonary tuberculosis (TB), at a secondary care teaching hospital in Seoul. Results: In total, 12 (15.6%) patients showed indeterminate results due to positive control failure on the QFT-GIT test. Indeterminate results were significantly associated with the elderly, history of the intensive care unit stay, lymphocytopenia, especially low CD4 count, increased C-reactive protein and decreased protein levels. Of the 77 patients, 44 (57.1%) were diagnosed with active pulmonary tuberculosis, and the percentage of false negative results of the QFT-GIT was 36.4% (vs. 31.8% with TST). In the TB group with >65 years old (n=12), the proportions of the indeterminate (33.3% vs. 3.1%) and the false negative results (58.3% vs. 25.0%) of the QFT-GIT were significantly higher than in the younger TB group (n=32). Conclusion: Indeterminate and false negative results of QFT-GIT test were not infrequent in tuberculosis, especially in the elderly. Care should be considered for the interpretation with the elderly, immunocompromised, chronic and severely diseased patients.

후종인대 골화증으로 유발된 경추 척수병증 1례에 대한 증례보고: 온침요법을 중심으로 (A Case Report of Cervical Myelopathy Caused by Ossification of Posterior Longitudinal Ligament: Focusing on Warm Needling Therapy)

  • 이승민;윤강현;임지석;조예은;박지민;남동우;최도영
    • Journal of Acupuncture Research
    • /
    • 제31권3호
    • /
    • pp.75-82
    • /
    • 2014
  • Objectives : The purpose of this study is to investigate the effects of warm needling therapy in a patient with cervical myelopathy caused by ossification of posterior longitudinal ligament. Methods : A 53-year-old Korean male patient diagnosed with cervical myelopathy due to ossification of posterior longitudinal ligament was treated with warm needling therapy on posterior neck aside from the routine inpatient treatment from June 26th to July 16th. Clinical improvement was evaluated with visual analogue scale(VAS), Japanese orthopedic score(JOA), grip and release test, finger escape sign and patient satisfaction was measured using a five-point Likert scale. Results : After 21 days of treatment, the patient showed improvement in VAS, JOA, grip and release test and finger escape sign. The patient also expressed satisfaction with the treatment. Conclusions : The results suggest that warm needling therapy may be an effective additional treatment for cervical myelopathy and other symptoms related to ossification of posterior longitudinal ligament(OPLL). Further studies should be carried out regarding possible long-lasting effects.

Re-evaluation of Korean Effluent Concentration Limits and Comparative Analysis

  • Hwang, Won Tae;Lee, Joeun;Kwon, Dahye;Kim, Eun Han;Han, Moon Hee
    • Journal of Radiation Protection and Research
    • /
    • 제43권3호
    • /
    • pp.124-129
    • /
    • 2018
  • Background: Effluent Concentration Limits (ECLs) were re-evaluated via direct calculation using dose coefficients based on radiation protection quantity introduced in Korea and the intrinsic breathing rates of Korean residents. Materials and Methods: The re-evaluated ECLs were compared with the domestic standards given in the Notice of the Nuclear Safety and Security Commission (NSSC), as well as with ECLs specified in the Code of Federal Regulations (CFR). Results and Discussion: The relative ratios of the re-evaluated ECLs to the currently applied domestic standards differed depending on the radionuclide type, but it was clearly shown that, for tritium ($^3H$) and radiocarbon ($^{14}C$), which significantly affect radiological dose to the public during the normal operation of nuclear power plants, the re-evaluated ECLs were higher than the domestic standards. This implies that Korean standards are relatively conservative. Conclusion: The re-evaluated results for each age group showed that $^{131}I$ (radioiodine), one of the significant radionuclides, had the lowest values, but nonetheless, the domestic standards for radioiodine were lower than the ECLs given in the CFR and the re-evaluated ECLs via a method given in the CFR.

IEEE 802.11 ax optimization design study in XR (eXtended Reality) training room

  • Chae, Yeon Keun;Chae, Myungsin
    • International Journal of Advanced Culture Technology
    • /
    • 제10권1호
    • /
    • pp.253-264
    • /
    • 2022
  • In the era of the pandemic, the importance of a wireless LAN environment has become increasingly important, especially as the era of smart working and non-face-to-face education has become a universal and daily routine. Smartphones, tablets, laptops, PCs, smart watches, and wearable devices, collective referred to as wireless terminals, can be accessed anytime and anywhere through the internet, allowing for consistent and constant access to offices, factories, warehouses, shopping malls, railways, hotels, hospitals, schools, logistics centers, airports, exhibition halls, etc. This sort of access is currently being used in roads, parks, traditional markets, and ports. Since the release of the IEEE 802.11 Legacy Standard in 1997, Wi-Fi technology has been continuously supplemented and revised, and the standard has been continuously developed. In the era of smart working, the importance of efficient wireless deployment and scientific design has become more important. The importance of wireless in the smart factory, in the metaverse era, in the era of pursuing work and life that transcend time and space by using AR, VR, MR, and XR, it is more urgent to solve the shadow area of Wi-Fi. Through this study, we intend to verify the wireless failure problem of the xr training center and suggest improvement measures.