• 제목/요약/키워드: Rotor Winding

검색결과 254건 처리시간 0.017초

Measurement of outgassing rates of Kevlar and S-Glass materials used in torque tubes of High Tc Superconducting (HTS) Motors

  • Thadela, S.;Muralidhar, BVAS;Kalyani, B;Choudhury, UK;Yadav, SN;Rao, V.V.
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제20권4호
    • /
    • pp.11-15
    • /
    • 2018
  • Torque tubes in High Temperature Superconducting (HTS) motor transfer torque from superconducting field winding rotor to the room temperature shaft. It should have minimum heat conduction property for minimizing the load on cryo-refrigerator. Generally, these torque tubes are made with stainless steel material because of high strength, very low outgassing and low thermal contraction properties at cryogenic temperatures and vacuum conditions. With recent developments in composite materials, these torque tubes could be made of composites such as Kevlar and S-Glass, which have the required properties like high strength and low thermal conductivity at cryogenic temperatures, but with a reduced weight. Development and testing of torque tubes made of these composites for HTS motor are taken up at Bharat Heavy Electricals Limited (BHEL), Hyderabad in collaboration with Central Institute of Plastics and Engineering Technology (CIPET), Chennai and Indian Institute of Technology (IIT), Kharagpur. As these materials are subjected to vacuum, it is important to measure their outgassing rates under vacuum conditions before manufacturing prototype torque tubes. The present study focusses on the outgassing characteristics of Kevlar and S-Glass, using an Outgassing Measurement System (OMS), developed at IIT Kharagpur. The OMS facility works under vacuum environment, in which the test samples are exposed to vacuum conditions over a sufficient period of time. The outgassing measurements for the composite samples were obtained using pressure-rise technique. These studies are useful to quantify the outgassing rate of composite materials under vacuum conditions and to suggest them for manufacturing composite torque tubes used in HTS motors.

펄스 신호 및 절연저항 측정 알고리즘을 이용한 전동기 열화 추정 (Estimation of Motor Deterioration using Pulse Signal and Insulation Resistance Measurement Algorithm)

  • 정성인
    • 한국인터넷방송통신학회논문지
    • /
    • 제22권5호
    • /
    • pp.111-116
    • /
    • 2022
  • 전동기 소손의 원인으로는 과부하, 결상, 구속, 층간단락, 권선의 지락, 순간과전압의 유입, 회전자가 고정자에 닿는 경우 등 절연파괴로 이어져 고장 또는 전기 사고로 이어지고 있다. 따라서 기기 고장은 기기의 보수/수리에 필요한 비용에 의한 손실뿐만 아니라, 전동기가 포함된 공정 자체를 멈추기 때문에 공정 정지에 따른 생산성 저하에 의한 막대한 경제적 손실을 초래한다. 전동기의 고장을 진단하기 위한 현재의 기술의 수준은 진동, 열, 전력분석 방식을 이용하고 있지만, 고장에 따른 상당 부분의 시간이 진행되어야 문제점을 분석할 수 있는 한계점을 가지고 있다. 따라서 본 논문에서는 이러한 문제점을 해결하고자 DC AMP 신호를 이용하여 절연저항을 측정하는 장치 및 알고리즘을 산업용 전동기에 적용하여 절연저항 상태값을 추종하여 기존방식에서 해결되지 못한 전동기의 열화 및 고장 진단을 제안한다.

유도전동기의 구속운전에 따른 전기 및 발열 특성 연구 (A Study on the Electrical and Heat Generation Characteristics of an Induction Motor under Restrained Operation)

  • 이종찬;김두현;김성철
    • 한국안전학회지
    • /
    • 제38권1호
    • /
    • pp.25-33
    • /
    • 2023
  • In this study, we determined the failure rate and fire status of electric motors widely used in domestic and industrial devices and analyzed the associated fire risks by identifying the electrical and temperature characteristics of electric motors under the normal and restrained operation modes in industrial sites and laboratories. A 2.2kW motor used for driving a conveyor during the vulcanization process in a rubber product manufacturing plant was employed as the study object and was exposed to a high- temperature environment as this motor is widely used in industrial sites. The current amplitude was 4.45-4.50 A during normal operation and 38.2-41.5 A during restrained operation due to the pinching of products and semi-finished products (i.e., 8.5 times higher than that during normal operation). The leakage current amplitude was 0.33 mA during both operation modes. The temperature of the workplace in summer was 42.38℃, indicating a poor environment for the installed motor. In the laboratory, the current and temperature of the coil inside a 3.7kW motor were measured under the restrained operation mode as performing measurements of the coil inside the motor in industrial sites is challenging. The current amplitude during normal operation was 3.5 A, whereas that during restrained operation for 30 s was 51.7-58.6 A, which is 14.8-16.7 times higher than that of normal operation. Moreover, the temperature of the motor coil increased from 22.9℃ to 101℃. Based on the experimental data, we derived the temperature increase formula according to the restrained operation time by performing a regression analysis and verified the time at which the temperature exceeded the stipulated limit for the insulation grade. The findings presented in this paper can be utilized to establish fire-prevention measures and perform safety management of motors of the same type or with a similar capacity.

이동형 전원장치용 3[kW] PMA-RSG의 최적 설계에 대한 연구 (A Study on 3[kW] PMA-RSG Optimal Design for Mobile Power Supply)

  • 백제훈;;김남훈
    • 조명전기설비학회논문지
    • /
    • 제23권6호
    • /
    • pp.109-117
    • /
    • 2009
  • 본 논문에서는 영구자석형 릴럭턴스 동기 발전기(PMA-RSG : Permanent magnet assisted-synchronous reluctance motor)에 대한 등가 자기 회로를 사용한 해석모델에 대해서 제시하고, 영구자석형 릴럭턴스 동기 발전기의 외형과 고정자 권선 그리고 특성을 결정하기 위해서 영구자석형 릴럭턴스 통기 발전기의 집중변수 모델(LPM : Lumped parameter model)을 제안한다. 집중변수 모델을 통하여 제안된 기기의 회전자 브리지에서 발생되는 자기 포화 현상에 대해서 예측하고, 기기의 성능에 대해서 효과적으로 검토한다. 집중변수 모델은 유한 요소법(FEM : Finite element method)에 비하여 정확하지는 않지만 영구자석형 릴럭턴스 동기 발전기의 자기적인 특성을 분석하는데 있어서 많은 시간이 걸리지 않으며, 초기 회전기기의 시제품 제작과 최적 설계에 있어서도 많은 장점을 가지고 있다. 집중변수 모델과 유한요소법을 통하여 영구자석형 릴럭턴스 동기발전기폭 초기 설계하고, 실제작을 고려하여 기기를 최적화하여 유한 요소법을 이용하여 설계 검증을 한다. 집중변수 모델의 선형 비선형 모델을 위해서 Matlab을 이용하였다. 제안된 영구자석형 릴럭턴스 통기발전기의 정당성을 검증하기 위해서 실제 역기전력 파형을 측정하였다.