• Title/Summary/Keyword: Rotator

Search Result 854, Processing Time 0.024 seconds

A Suture Bridge Transosseous-Equivalent Technique for Bankart Lesions with Deficient Bony Stability - Technical Note - (골안정성 결손을 가진 Bankart 병변에 대한 경 골-유사 교량형 봉합술식 - 술기 보고 -)

  • Choi, Chang-Hyuk;Kim, Shin-Kun;Chang, Il-Woong;Chae, Sung-Bum
    • Journal of the Korean Arthroscopy Society
    • /
    • v.13 no.2
    • /
    • pp.179-182
    • /
    • 2009
  • Purpose: Point fixation at the margin of the glenoid is a limitation of conventional arthroscopic stabilization using suture anchors, and does not afford sufficient footprint healing, especially in glenoid bone deficiency. So, we introduce an arthroscopic suture bridge transosseous-equivalent technique for bony Bankart lesions to avoid the technical disadvantage of point contact with anchor fixation and to improve mechanical stability through cross compression of the labrum. Surgical approach: The technique was adapted from the transosseous-equivalent rotator cuff repair technique using suture bridges, which improved the pressurized contact area and mean pressure between the tendon and footprint. After preparation of the glenoid bed by removal, reshaping, or mobilization of the bony lesion, two anchors (3.0 mm Biofastak, $Arthrex^{(R)}$, Naples, FL) were inserted into the superior and inferior portion of the bony Bankart lesion. Using a suture hook, medial mattress sutures were applied around the capsulolabral portion of the IGHL complex to obtain sufficient depth of glenoid coverage. A 3.5 mm pushloc anchor ($Arthrex^{(R)}$, Naples, FL) hole was made in the articular edge of the anterior glenoid rim. distal, suture bridge was applied, and proximal was inserted to mobilize the labrum in the proximal direction. This avoided the technical disadvantage of point contact with anchor fixation and decreased the level of gap formation through cross-compression of the labrum.

  • PDF

Acute postoperative myelopathy caused by spontaneous developed cervical disc herniation: Case report & literature review (수술후 자연발생 경추간판탈출에 의한 척수병증: 증례보고 및 문헌고찰)

  • Lee, Jeong-Woo;Lee, Keun Hyeong;Lee, Ju-Hwan
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.10
    • /
    • pp.303-308
    • /
    • 2019
  • Non-traumatic acute myelopathy caused by cervical disc herniation is rare. To date, no case has been reported to be caused by extrusion cervical disc herniation, unrelated to patient posture during surgery. Here, we report the case of a 65-year-old male patient with cervical myelopathy who underwent subsequent arthroscopic rotator cuff surgery under general anesthesia; non-cervical spine surgery. Ed. Notes: I am unable to understand the insertion of the highlighted phrase. Please delete if not required, or revise the sentence appropriately. Patient showed acute postoperative tetraplegia in spite of optimal anesthetic management. He showed no limitation of neck movement at pre-operative airway evaluation, and had no history of trauma to the cervical spine. During surgery, there had been no overextension or twisting of the neck, including at the time of anesthetic induction by tracheal intubation. However, cervical disc herniation causing spinal canal cord compression was detected in the postoperative magnetic resonance imaging, which probably resulted in tetraplegia of the patient. Motor and sensory functions were recovered after 21 days of conservative treatment, including steroid pulse intravenous therapy without any surgical intervention. In this report, the disease is described after reviewing other reported cases; furthermore, we also discuss the pathophysiology of the disease. Based on our report, we propose that under general anesthesia, clinicians should pay attention to the possibility of pre-existing cervical disease, even in non-cervical spine surgeries of geriatric patients.

A Study on MR Imaging Method for The Patient with Inserting Shoulder Joint Suture Anchor (견관절 삽입술을 시행한 환자의 자기 공명 영상법에 관한 연구)

  • Park, Eui-Cheol;Bae, Seok-Hwan;Ryu, Yeun-Chul;Park, Young-Joon;Kim, Yong-Gwon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.22 no.4
    • /
    • pp.513-519
    • /
    • 2021
  • Metallic suture anchors are very useful and common fixation devices that are inserted into the target bone to sustain the tendon of a patient with musculus supraspinatus tendon ruptures. On the other hand, the presence of a metallic material prosthesis, such as a metal suture anchor, causes severe MR imaging artifacts, including field distortion, signal loss, and failure of fat suppression. The difference in magnetic susceptibility between metal and other organic materials causes magnetic field distortion surrounding the prosthesis. The resulting magnetic field inhomogeneity makes the images with a lower signal-to-noise ratio and distortion. For a patient with a suture anchor implanted, MR imaging is the golden standard for determining the postoperative prognosis, and a fat-saturation sequence is one of the imaging methods most affected by metal-induced artifacts. In this study, three fat-saturation sequences were compared. Artifact quantification and contrast comparison between the supraspinatus tendon and the surrounding muscle were presented. The images obtained using the STIR pulse sequence showed fewer susceptibility artifacts and better visibility in the supraspinatus tendon and the tissue area. Therefore, the STIR sequence is the most appropriate fat-saturation imaging method for patients with a metallic prosthesis.

Radiologic Comparison of Humeral Position according to the Implant Designs Following Reverse Shoulder Arthroplasty: Analysis between Medial Glenoid/Medial Humerus, Lateral Glenoid/Medial Humerus, and Medial Glenoid/Lateral Humerus Designs

  • Cho, Nam Su;Nam, Ju Hyun;Hong, Se Jung;Kim, Tae Wook;Lee, Myeong Gu;Ahn, Jung Tae;Rhee, Yong Girl
    • Clinics in Shoulder and Elbow
    • /
    • v.21 no.4
    • /
    • pp.192-199
    • /
    • 2018
  • Background: The currently available reverse shoulder arthroplasty (RSA) designs can be classified into medial glenoid/medial humerus (MGMH), lateral glenoid/medial humerus (LGMH), and medial glenoid/lateral humerus (MGLH) prosthesis designs. The purpose of this study was to radiologically analyze the effect of different RSA designs on humeral position following RSA. Methods: A total of 50 patients who underwent primary RSA were retrospectively analyzed. Among 50 patients, 33 patients (group A: MGMH) underwent RSA with Aequalis system (Wright, Inc, Bloomington, MN, USA), 6 (group B: LGMH) with Aequalis system using bony increased offset, and 11 (group C: MGLH) with Aequalis Ascend Flex system. The acromiohumeral distance, acromioepiphyseal distance (AED), lateral humeral offset (LHO), LHO from the center of rotation ($LHO^{COR}$), and deltoid length were radiologically measured to quantify the distalization and lateralization of the humerus. Results: The increment in postoperative AED was $19.92{\pm}3.93mm$ in group A, $24.52{\pm}5.25mm$ in group B, and $25.97{\pm}5.29mm$ in group C, respectively (p=0.001). The increment in postoperative LHO was $0.13{\pm}6.30mm$, $8.00{\pm}12.14mm$, and $7.42{\pm}6.88mm$, respectively (p=0.005). The increment in postoperative $LHO^{COR}$ was $20.76{\pm}6.06mm$, $22.04{\pm}5.15mm$, and $28.11{\pm}4.14mm$, respectively (p=0.002). Conclusions: The radiologic analysis of the effect of different RSA designs on humeral position following RSA showed significant differences in the increment in postoperative AED, LHO, and $LHO^{COR}$ between the 3 groups. Therefore, MGLH design seems to be more effective for humeral distalization and lateralization compared to original Grammont design.

Opto-Mechanical Detailed Design of the G-CLEF Flexure Control Camera

  • Jae Sok Oh;Chan Park;Kang-Min Kim;Heeyoung Oh;UeeJeong Jeong;Moo-Young Chun;Young Sam Yu;Sungho Lee;Jeong-Gyun Jang;Bi-Ho Jang;Sung-Joon Park;Jihun Kim;Yunjong Kim;Andrew Szentgyorgyi;Stuart McMuldroch;William Podgorski;Ian Evans;Mark Mueller;Alan Uomoto;Jeffrey Crane;Tyson Hare
    • Journal of The Korean Astronomical Society
    • /
    • v.56 no.2
    • /
    • pp.169-185
    • /
    • 2023
  • The GMT-Consortium Large Earth Finder (G-CLEF) is the first instrument for the Giant Magellan Telescope (GMT). G-CLEF is a fiber feed, optical band echelle spectrograph that is capable of extremely precise radial velocity measurement. G-CLEF Flexure Control Camera (FCC) is included as a part in G-CLEF Front End Assembly (GCFEA), which monitors the field images focused on a fiber mirror to control the flexure and the focus errors within GCFEA. FCC consists of an optical bench on which five optical components are installed. The order of the optical train is: a collimator, neutral density filters, a focus analyzer, a reimager and a detector (Andor iKon-L 936 CCD camera). The collimator consists of a triplet lens and receives the beam reflected by a fiber mirror. The neutral density filters make it possible a broad range star brightness as a target or a guide. The focus analyzer is used to measure a focus offset. The reimager focuses the beam from the collimator onto the CCD detector focal plane. The detector module includes a linear translator and a field de-rotator. We performed thermoelastic stress analysis for lenses and their mounts to confirm the physical safety of the lens materials. We also conducted the global structure analysis for various gravitational orientations to verify the image stability requirement during the operation of the telescope and the instrument. In this article, we present the opto-mechanical detailed design of G-CLEF FCC and describe the consequence of the numerical finite element analyses for the design.

Concomitant open distal clavicle excision is associated with greater improvement in range of motion without increased risk of acromial stress fracture after reverse total shoulder arthroplasty: a retrospective cohort study

  • Ajay C. Kanakamedala;Dhruv S. Shankar;Neil Gambhir;Matthew R. Boylan;Michael Boin;Matthew G. Alben;Mandeep S. Virk;Young W. Kwon
    • Clinics in Shoulder and Elbow
    • /
    • v.26 no.4
    • /
    • pp.357-365
    • /
    • 2023
  • Background: The purpose of this study was to evaluate the effect of concomitant open distal clavicle excision (DCE) on postoperative clinical outcomes and incidence of acromial and scapular stress fractures (ASFs) in patients with symptomatic acromioclavicular joint osteoarthritis (ACJ OA) undergoing reverse total shoulder arthroplasty (RTSA). Methods: A single-surgeon retrospective cohort study was conducted including patients who underwent primary elective RTSA with or without DCE from 2015 to 2019 with a minimum 6-month follow-up period. Shoulder active range of motion (AROM) and visual analog scale (VAS) pain were recorded preoperatively and postoperatively. ASFs and other adverse events were identified using postoperative notes and/or radiographs. Characteristics and outcomes were compared between the RTSA and RTSA-DCE groups. Results: Forty-six RTSA patients (mean age, 67.9±8.7 years; 60.9% male; mean follow-up, 24.9±16.6 months) and 70 RTSA-DCE patients (mean age, 70.2±8.9 years; 20.0% male; mean follow-up, 22.7±12.9 months) were included. There were no significant intergroup differences in rates of ASF (RTSA, 0.0% vs. RTSA-DCE, 1.4%; P=1.00), stress reactions (RTSA, 8.7% vs. RTSA-DCE, 11.4%; P=0.76), reoperation, revision, or infection (all P>0.05), or in pre-to-postoperative reduction in VAS pain (P=0.17) at latest follow-up. However, the RTSA-DCE group had greater pre-to-postoperative improvement in flexion AROM (RTSA, 43.7°±38.5° vs. RTSA-DCE, 59.5°±33.4°; P=0.03) and internal rotation (IR) AROM (P=0.02) at latest follow-up. Conclusions: Concomitant DCE in RTSA improves shoulder flexion and IR AROM, alleviates shoulder pain, and does not increase the risk of ASFs. Level of evidence: III.

Preoperative Shoulder MRI Findings to Predict Subscapularis Tendon Tear Requiring Surgical Repair (수술이 필요한 견갑하건 파열을 예측하기 위한 수술 전 어깨 MRI 소견)

  • Ji-hoon Jung;Young-Hoon Jo;Yeo Ju Kim;Seunghun Lee;JeongAh Ryu
    • Journal of the Korean Society of Radiology
    • /
    • v.85 no.1
    • /
    • pp.171-183
    • /
    • 2024
  • Purpose This study aimed to investigate which indirect parameters on preoperative MRI were the principal predictors of subscapularis tendon tears (STTs) requiring surgical repair. Materials and Methods Preoperative MRI scans of 86 patients were retrospectively reviewed for visual assessment of the STT, pathology of the long head of the biceps tendon (LHBT), posterior decentering (PD) of the humeral head, humeral rotation, fatty degeneration, and subscapularis muscle atrophy. To evaluate atrophy, visual grading using the anatomical line connecting the coracoid tip to the glenoid base, designated as the base-to-tip line (BTL), and thickness measurements were performed in the en-face view. Results Arthroscopically, 31 patients (36%) exhibited Lafosse type III or IV STT and underwent surgical repair. LHBT pathology (p = 0.002), PD of the humeral head (p = 0.012), fatty degeneration (p < 0.001), and BTL grade (p = 0.003) significantly correlated with STT. In the multivariate analysis, PD of the humeral head (p = 0.011, odds ratio [OR] = 5.14) and fatty degeneration (p = 0.046, OR = 2.81) were independent predictors of STT. Conclusion PD of the humeral head and fatty degeneration of the subscapularis can help to diagnose clinically significant STT. Interpretation of these findings may contribute to the planning of an optimal surgical strategy.

Effect of Patient's Positioning on the Grade of Tendinosis and Visible Range of Infraspinatus Tendon on Ultrasound (초음파 영상에서 극하근 힘줄병의 단계와 관찰가능 범위에 환자의 자세가 미치는 영향)

  • Jee Won Chai;Joo-ho Lee;Dong Hyun Kim;Jina Park;So-Hee Oh;Su-Mi Shin
    • Journal of the Korean Society of Radiology
    • /
    • v.84 no.3
    • /
    • pp.627-637
    • /
    • 2023
  • Purpose To investigate the effect of patient positioning on tendinosis grade, visible range, and infraspinatus tendon (IST) thickness, and to determine the feasibility of internal rotation (IR) position to assess IST on ultrasound (US). Materials and Methods This study included 52 shoulders of 48 subjects who were evaluated for IST in three different positions: neutral position (N), IR, and position with the ipsilateral hand on the contralateral shoulder (HC). Two radiologists retrospectively graded IST tendinosis from grade 0 to grade 3 and the visible range from grade 1 to grade 4. The thickness of the IST was measured by another radiologist with a short-axis view. A generalized estimating equation was used for statistical analysis. Results The tendinosis grades were higher in the HC position than in the IR position, with a cumulative odds ratio of 2.087 (p = 0.004, 95% confidence interval [CI]: 1.268-3.433). The tendinosis grades in the HC position (p = 0.370) and IR position (p = 0.146) were not significantly different from those in the N position. The overall difference in IST thickness was significant (p < 0.001), but the visible range (p = 0.530) was not significantly different according to position. Conclusion Patient positioning significantly affected the grade of tendinosis and thickness but not the visible range of the IST. The IR position is a feasible position for assessing the IST on US.

The Clinical Outcomes of Arthroscopic Repair of Isolated type II SLAP Lesion in Non-athletes (비 운동선수에 있어 단독 제 2형 SLAP 병변의 관절경적 봉합수술의 임상적 결과)

  • Yoo, Jae-Chul;Ahn, Jin-Hwan;Koh, Kyoung-Hwan;Kim, Seung-Yeon
    • Journal of the Korean Arthroscopy Society
    • /
    • v.12 no.3
    • /
    • pp.185-190
    • /
    • 2008
  • Purpose: The purpose of this study is to provide the clinical outcomes of arthroscopic type II SLAP repair in non-athletes, and to compare the clinical outcomes between those who had isolated type II SLAP lesion and those who had combined partial thickness supraspinatus tear that did not required a combined repair. Materials and Methods: From July 2005 to January 2007, 142 consecutive type II SLAP lesions were treated with arthroscopic surgery. The inclusion criteria for the study were; (1) younger than 50 years old; and (2) non-athletes. Exclusion criteria were; (1) prior surgery, fracture or combined recurrent dislocation history on the affected shoulder; (2) combined full thickness rotator cuff tear or PTST (>50% thickness) patient that needed repair; and (3) combined infection, arthritis or inflammatory disease. Remaining 19 patients meet the criteria. Among them, 13 had combined PTRCT that did not require repair (Group I), and 6 had isolated type II SLAP lesion without combined supraspinatus tear (Group II). The mean age was 36.7 years (29~49 years), mean symptom duration was 39.1 months (3~216 months) and mean follow-up was 19.0 months (12~27 months). In all patients, the range of motion of affected shoulder, pain and function visual analogue scale (PVAS, FVAS), the Constant score and UCLA score were evaluated preoperatively and postoperatively. Results: In group I, external rotation at side was decreased significantly (p=0.003),but there were no statistical significant change at the remains(p>0.05). And there were no differences between groups (p>0.05). At the final follow-up, all clinical outcome measurements improved after surgery with statistical significance (p<0.05): UCLA score, $22.8{\pm}5.2$ to $32.8{\pm}2.1$; Constant score, $79.4{\pm}8.6$ to $94.9{\pm}4.3$; PVAS $5.4{\pm}2.7$ to $1.1{\pm}1.4$; FVAS $63.2{\pm}15.3$ to $93.4{\pm}7.3$. But, in group comparison of the mean UCLA score and Constant score, there were no statistical significant differences between two groups. Conclusion: Arthroscopic repair of type II SLAP lesion provided good clinical outcomes in nonathletic population. Combined partial thickness supraspinatus tear does not seem to hamper the final outcome at minimal 1 year follow-up.

  • PDF

Arthroscopic Treatment of Greater Tuberosity fracture - Preliminary Report - (상완골 대결절 골절 손상에 대한 관절경적 치료 -예비 보고-)

  • Ji, Jong-Hoon;Kim, Young-Yul;Park, Sang-Eun;Ra, Ki-Hang;Do, Jeong-Hun;Kim, Weon-Yoo
    • Journal of Korean Orthopaedic Sports Medicine
    • /
    • v.6 no.1
    • /
    • pp.57-65
    • /
    • 2007
  • Purpose: The purpose of this study was to evaluate the clinical result of arthroscopic treatments by using suture anchors or suture anchors combined with cannulated screw in the greater tuberosity fracture of the proximal humerus fracture. Materials and Methods: From March 2004 to March 2006 we have used suture anchor or suture anchors combined with cannulated screw for 6 cases of the greater tuberosity fracture which include displaced fractures, comminuted fractures and minimally displaced fractures with comcomittent lesions such as rotator cuff tears, stiffness and labral lesion. In this retrospective study, we analyzed the clinical outcomes by using the range of motion, University of California at Los Angeles shoulder rating scale (UCLA) and the ASES shoulder index score (ASES) in the average 6 months follow up. Results: At the last follow up, average range of motion was improved to 154.3 degree, 145.8 degree, 32.6 degree and L1 vertebrae in each forward flexion, abduction, external rotation and internal rotation. Clinically the UCLA rating scales improved to 31.5 and the ASES shoulder index score (ASES) improved to 93.6 in the last follow up. Conclusion: Arthroscopic treatments by using suture anchor or suture anchors combined with cannulated screw in the greater tuberosity fracture of the proximal humerus fracture is an alternative treatment of the greater tuberosity fracture of the proximal humerus fracture.

  • PDF