• Title/Summary/Keyword: Rotational Axis

Search Result 278, Processing Time 0.031 seconds

Fatigue Durability Evaluation of Refraction Expansion Joints (굴절형 신축이음장치의 피로내구성 평가)

  • Na, Jun-Su;Lee, Ta;Han, Eui-Seok;Sung, Won-Kyu;Lee, Jong-Suk
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.21 no.6
    • /
    • pp.10-15
    • /
    • 2017
  • The refraction expansion joints have been newly developed by complementing the problems of shock, noise, replaceability, displacement in the direction perpendicular to bridge, vertical difference, which are problems of existing expansion joints. The Refraction expansion joints are characterized by continuous surfaces with small impact and low noise. The behavior of the Refraction expansion joints performs the bridge expansion behavior by rotation of the link. In the rotational behavior of the link, the bolt is the central axis of the behavior. Therefore, it can be said that the durability of the bolt is very important. However, the theoretical and experimental verification of the bolt durability of the Refraction expansion joint is lacking. In this paper, to verify the fatigue durability of the bolt, test specimens with a 300 mm Refraction expansion joint were fabricated. A strain gauge dedicated to the bolt was installed inside the manufactured test specimen bolt. The test method was applied in accordance with KS F 4425. The fatigue durability of the bolts assembled inside the diaphragm expansion joint was confirmed by the repeated fatigue test of 2,000,000 cycles.

Systematic Error Correction in Dual-Rotating Quarter-Wave Plate Ellipsometry using Overestimated Optimization Method (최적화 기법을 이용한 두 개의 회전하는 사분파장판으로 구성된 타원편광분석기에서의 체계적인 오차 보정)

  • Kim, Dukhyeon;Cheong, Hai Du;Kim, Bongjin
    • Korean Journal of Optics and Photonics
    • /
    • v.25 no.1
    • /
    • pp.29-37
    • /
    • 2014
  • We have studied and demonstrated general, systematic error-correction methods for a dual rotating quarter-wave plate ellipsometer. To estimate and correct 5 systematic error sources (three offset angles and two unexpected retarder phase delays), we used 11 of the 25 Fourier components of the ellipsometry signal obtained in the absence of an optical sample. Using these 11 Fourier components, we can determine the errors from the 5 sources with nonlinear optimization methods. We found systematic errors ${\epsilon}_3$, ${\epsilon}_4$, ${\epsilon}_5$) are more sensitive to the inverted Mueller matrix than retarder phase delay errors (${\epsilon}_1$, ${\epsilon}_2$) because of their small condition numbers. To correct these systematic errors we have found that error of any variety must be less than 0.05 rad. Finally, we can use the magnitudes of these errors to correct the Mueller matrix of optical components. From our experimental ellipsometry signals, we can measure phase delay and the rotational angular position of its fast axis for a half-wave plate.

Paraboloidal 2-mirror Holosymmetric System with Unit Maginification for Soft X-ray Projection Lithography (연X-선 투사 리소그라피를 위한 등배율 포물면 2-반사경 Holosymmetric System)

  • 조영민;이상수
    • Korean Journal of Optics and Photonics
    • /
    • v.6 no.3
    • /
    • pp.188-200
    • /
    • 1995
  • A design of unit magnification 2-mirror system with high resolution is presented. It is for soft X-ray(wavelength of 13 nm) projection imaging and suitable for preparation of high density semiconductor chip. In general, a holosymmetric system with unit magnification has the advantage that both coma and distortion are completely eliminated. In our holosymmetric 2-mirror system, spherical aberration is addtionally removed by using two identical paraboloidal mirror surfaces and field curvature aberration is also corrected by balancing Petzval sum and astigmatism which depends on the distance between two mirrors, so that the system is a aplanatic flat-field paraboloidal 2-mirror holosymmetric system. This 2-mirror system is small in size, and has a simple configuration with rotational symmetry about optical axis, and has also small central obscuration. Residual finite aberrations, spot diagrams, and diffraction-based MTF's are analyzed for the check of performances as soft X-ray lithography projection system. As a result, the image sizes for the resolutions of$0.25\mum$and $0.18\mum$are 4.0 mm, 2.5 mm respectively, and depths of focus for those are $2.5\mum$, $2.4\mum$respectively. This system should be useful in the fabrication of 256 Mega DRAM or 1 Giga DRAM. DRAM.

  • PDF

A STUDY ON THE ARMILLARY SPHERE OF TONGCHEON-UI DESCRIBED BY HONG DAE-YONG (홍대용 통천의의 혼천의 연구)

  • MIHN, BYEONG-HEE;YUN, YONG-HYUN;KIM, SANG HYUK;KI, HO CHUL
    • Publications of The Korean Astronomical Society
    • /
    • v.36 no.3
    • /
    • pp.79-95
    • /
    • 2021
  • This study aims to develop a restoration model of an armillary sphere of Tongcheon-ui (Pan-celestial Armillary Sphere) by referring to the records of Damheonseo (Hong Dae-Yong Anthology) and the artifact of an armillary sphere in the Korean Christian Museum of Soongsil University. Between 1760 and 1762, Hong, Dae-Yong (1731-1783) built Tongcheon-ui, with Na, Kyung-Jeok (1690-1762) designing the basic structure and Ann, Cheo-In (1710-1787) completing the assembly. The model in this study is a spherical body with a diameter of 510 mm. Tongcheon-ui operates the armillary sphere by transmitting the rotational power from the lantern clock. The armillary sphere is constructed in the fashion of a two-layer sphere: the outer one is Yukhab-ui that is fixed; and the inner one, Samsin-ui, is rotated around the polar axis. In the equatorial ring possessed by Samsin-ui, an ecliptic ring and a lunar-path ring are successively fixed and are tilted by 23.5° and 28.5° over the equatorial ring, respectively. A solar miniature attached to a 365-toothed inner gear on the ecliptic ring reproduces the annual motion of the Sun. A lunar miniature installed on a 114-toothed inner gear of the lunar-path ring can also replay the moon's orbital motion and phase change. By the set of 'a ratchet gear, a shaft and a spur gear' installed in the solstice-colure double-ring, the inner gears in the ecliptic ring and lunar-path ring can be rotated in the opposite direction to the rotation of Samsin-ui and then the solar and lunar miniatures can simulate their revolution over the period of a year and a month, respectively. In order to indicate the change of the moon phases, 27 pins were arranged in a uniform circle around the lunar-path ring, and the 29-toothed wheel is fixed under the solar miniature. At the center of the armillary sphere, an earth plate representing a world map is fixed horizontally. Tongcheon-ui is the armillary sphere clock developed by Confucian scholars in the late Joseon Dynasty, and the technical level at which astronomical clocks could be produced at the time is of a high standard.

A Study for Predicting Rotational Cutting Torque from Electrical Energy Required for Ground Drilling (지반절삭 전기에너지를 활용한 회전굴착토크 예측에 관한 연구)

  • Choi, Chang-Ho;Cho, Jin-Woo;Lee, Yong-Soo;Chung, Ha-Ik;Park, Yong-Boo
    • Journal of the Korean Geotechnical Society
    • /
    • v.23 no.7
    • /
    • pp.57-64
    • /
    • 2007
  • This study proposes a method to estimate drilling torque during ground boring with an aid of electrical energy required for rotating a boring-auger. Ground boring is commonly used in geotechnical engineering such as preboring precast pile installation, soil-cement grouting, ground exploration and so forth. In order to understand the correlation between required electrical energy to rotate the boring auger and the drilling torque, a small laboratory apparatus was designed and a pilot study was performed. The apparatus rotates common drill bits of $D=5{\sim}25mm$ in CBR specimens. The velocity of a bit is 19 RPM and predefined using a reduction gear which connects a main rotation axis to a 25 Watts AC electrical motor shaft. In the middle of drilling the motor current increments and the drilling torque were measured and the correlation between the current and the torque was obtained through linear square fits. Based on the correlation the acquired motor current during drilling was applied to predict the drilling torque in consequent testing and the prediction results were compared to the measured torque. The comparison leads a conclusion that the motor current during drilling using electrical power may be a good indicator to estimate/determine strength characteristics of the ground.

Development of Quality Assurance Software for $PRESAGE^{REU}$ Gel Dosimetry ($PRESAGE^{REU}$ 겔 선량계의 분석 및 정도 관리 도구 개발)

  • Cho, Woong;Lee, Jaegi;Kim, Hyun Suk;Wu, Hong-Gyun
    • Progress in Medical Physics
    • /
    • v.25 no.4
    • /
    • pp.233-241
    • /
    • 2014
  • The aim of this study is to develop a new software tool for 3D dose verification using $PRESAGE^{REU}$ Gel dosimeter. The tool included following functions: importing 3D doses from treatment planning systems (TPS), importing 3D optical density (OD), converting ODs to doses, 3D registration between two volumetric data by translational and rotational transformations, and evaluation with 3D gamma index. To acquire correlation between ODs and doses, CT images of a $PRESAGE^{REU}$ Gel with cylindrical shape was acquired, and a volumetric modulated arc therapy (VMAT) plan was designed to give radiation doses from 1 Gy to 6 Gy to six disk-shaped virtual targets along z-axis. After the VMAT plan was delivered to the targets, 3D OD data were reconstructed from 512 projection data from $Vista^{TM}$ optical CT scanner (Modus Medical Devices Inc, Canada) per every 2 hours after irradiation. A curve for converting ODs to doses was derived by comparing TPS dose profile to OD profile along z-axis, and the 3D OD data were converted to the absorbed doses using the curve. Supra-linearity was observed between doses and ODs, and the ODs were decayed about 60% per 24 hours depending on their magnitudes. Measured doses from the $PRESAGE^{REU}$ Gel were well agreed with the TPS doses at central region, but large under-doses were observed at peripheral region at the cylindrical geometry. Gamma passing rate for 3D doses was 70.36% under the gamma criteria of 3% of dose difference and 3 mm of distance to agreement. The low passing rate was resulted from the mismatching of the refractive index between the PRESAGE gel and oil bath in the optical CT scanner. In conclusion, the developed software was useful for 3D dose verification from PRESAGE gel dosimetry, but further improvement of the Gel dosimetry system were required.

Evaluation on Usefulness of Stereotactic Radio Surgery using $Fraxion^{(R)}$ System ($Fraxion^{(R)}$ System을 이용한 뇌 정위적 방사선 수술 유용성 평가)

  • Kim, Tae Won;Park, Kwang Woo;Ha, Jin Sook;Jeon, Mi Jin;Cho, Yoon Jin;Kim, Sei Joon;Kim, Jong Dae;Shin, Dong Bong
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.2
    • /
    • pp.345-354
    • /
    • 2014
  • Purpose : We evaluated the usefulness of $Fraxion^{(R)}$ system and s-thermoplastic mask by analyzing setup error when stereotactic radiousurgery (SRS) was treated for brain metastasis. Materials and Methods : 6 patients who received definite diagnosis as brain metastasis between May 2014 and October 2014 were selected. 3 patients were immobilized s-thermoplastic mask and mouthpiece (group1), while $Fraxion^{(R)}$ system was used for the other 3 patients (group2). Cone Beam Computerized Tomography (CBCT) scan was acquired to register planning CT scan. The registration offset was compared for each group. We compared and reported the errors using maximum, minimum, mean, and standard deviation of registration offsets. Furthermore, We used the same method as patient specific quality assurance to verify absorbed dose of PTV. Results : The setup error which is registration offset was reduced 83% in x, 40% in y, and 92% in z-direction when $Fraxion^{(R)}$ system was used compared to the case of using s-thermoplastic mask and mouthpiece. In addition, using $Fraxion^{(R)}$ system showed improved results in rotational components, pitch (rotation along x-axis), roll (y), and yaw (z) which were reduced 64, 88, and 87% respectively compared to the case of using s-thermoplastic mask and mouthpiece. In dosimetry results, when s-thermoplastic mask and mouthpiece used, absorbed dose was reduce 83% compared to before and after registration. However, using $Fraxion^{(R)}$ system showed only 1.9%. All percentage were calculated with respect to average value. Conclusion : Using $Fraxion^{(R)}$ system including mouthpiece, Fraxion frame, frontpiece, and thermoplastic mask, showed better repeatability and precision compared to using s-thermoplastic mask and mouthpiece, which is consequently considered as more improved immobilization system.

Evaluation of Setup Errors for Tomotherapy Using Differently Applied Vacuum Compression with the Bodyfix Immobilization System (토모테라피 치료 시 Bodyfix System에서 진공압박에 따른 환자 위치잡이오차(Setup errors)의 평가)

  • Jung, Jae-Hong;Cho, Kwang-Hwan;Lee, Jeong-Woo;Kim, Min-Joo;Lim, Kwang-Chae;Moon, Seong-Kwon;Kim, Yong-Ho;Suh, Tae-Suk
    • Progress in Medical Physics
    • /
    • v.22 no.2
    • /
    • pp.72-78
    • /
    • 2011
  • The aim of this study is to evaluate the patient's setup errors in TomoTherapy (Hi-Art II, TomoTherapy, USA) Bodyfix system (Medical Intelligence, Ele-kta, Schwabmuchen, Germany) pressure in the vacuum compression, depending on and were evaluated. Bodyfix immobilization system and vacuum pressure was compression applied to the patients who received Tomotherapy thoracic and abdominal area, 21 patients were selected and TomoTehpay treatment total 477 of MVCT images were obtained. The translational (medial-lateral: ML, anterior-posterior: AP, superior-inferior: SI directions) and rolling were recorded and analyzed statistically. Using Pearson's product-moment coefficient and One-way ANOVA, the degree of correlation depending on the different vacuum pressure levels were statistically analyzed for setup errors from five groups (p<0.05). The largest average and standard deviation of systematic errors were 6.00, 5.95 mm in the AP and SI directions, respectively. The largest average of random errors were 4.72 mm in the SI directions. The correlation coefficients were 0.485, 0.244, and 0.637 for the ML-Roll, AP-Vector, and SI-Vector, respectively. SI-Vector direction showed the best relationship. In the results of the different degree of vacuum pressure in five groups (Pressure range: 30~70 mbar), the setup errors between the ML, SI in both directions and Roll p=0.00 (p<0.05) were shown significant differences. The average errors of SI direction in the vacuum pressure of 40 mbar and 70 mbar group were 4.78 mm and -0.74 mm, respectively. In this study, the correlation between the vacuum pressure and the setup-errors were statistically analyzed. The fact that setup-errors in SI direction is dependent in vacuum pressure considerly setup-errors and movement of interal organs was identified. Finally, setup-errors, and it, based on the movement of internal organs in Bodyfix system we should apply more than 50 mbar vacuum pressure. Based on the results of this study, it is suggested that accuracy of the vacuum pressure and the quantitative analysis of movement of internal organs and the tumor should be studied.