• 제목/요약/키워드: Rotation tip

Search Result 132, Processing Time 0.032 seconds

Investigation of Lateral Resistance of Short Pile by Large-Scale Load Tests (실물 재하시험을 통한 짧은말뚝의 횡방향 저항거동 평가)

  • Lee, Su-Hyung;Choi, Yeong-Tae;Lee, Il-Wha;Yoo, Min-Taek
    • Journal of the Korean Geotechnical Society
    • /
    • v.33 no.8
    • /
    • pp.5-16
    • /
    • 2017
  • When a lateral load is applied to a short pile whose embedded depth is relatively smaller than its diameter, an overturning failure occurs. To investigate the behavior of laterally loaded short piles, several model tests in laboratory scales had been carried out, however the behavior of large moment carrying piles for electric poles, traffic sign and road lamp, etc. have not been revealed yet. This paper deals with the real-scale load tests for 750 mm diameter short piles. To simulate the actual loading condition, very large moment was mobilized by applying lateral loads to the location 8 m away from the pile head. Three load tests changing the pile embedded lengths to 2.0 m, 2.5 m, and 3.0 m were carried out. The test piles overturned abruptly with very small displacement and rotation before the failures. These brittle failures are in contrast with the ductile failures shown in the former model tests with the relatively smaller moment to lateral load ratio. Comparisons of the test results with three existing methods for the estimation of the ultimate lateral capacity show that the method assuming the rotation point at pile tip matches well when the embedded depth is small, however, as the embedded depth increases the other two methods assuming the inversion of soil pressure with respect to rotation points in pile length match better.

Study about the relationship between the amount of posterior impaction and the change of occlusal plane angle and incisor inclination in Le Fort I osteotomy (Le Fort I 골절단술에서 posterior impaction의 양과 occlusal plane angle, incisor inclination의 변화 관계에 관한 연구)

  • Kim, Bok-Joo;Kim, Min-Gu;Kim, Jung-Han;Kim, Chul-Hoon
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.36 no.5
    • /
    • pp.375-379
    • /
    • 2010
  • Introduction: In the management of dentofacial deformities, variable movement of the maxilla can be made possible by a Le Fort I osteotomy. Posterior impaction of the maxilla necessary for rotation of the maxillomandibular complex enhances the functions and esthetic results. In cases of posterior impaction of the maxilla, an increase in the figure of the occlusal plane angle and incisor inclination can occur. This study reports the relationship between the amount of posterior impaction and the change in the occlusal plane angle and incisor inclination in a Le Fort I osteotomy by preoperative and postoperative lateral cephalograms. Materials and Methods: Twenty patients who had undergone orthognathic surgery in Dong-A University Medical Center participated in this study. Lateral cephalometrics, within 3 weeks prior to surgery and 3 days after surgery, were used for analysis. Pre and postoperative measurements of the occlusal plane angle and incisal inclination based on the Frankfort horizontal (FH) plane were performed. X and Y were defined as the amount of vertical change in the upper incisor tip and the amount of vertical change in the upper first molar mesial cup tip through the operation. The amount of final posterior maxillary impaction was determined by subtracting Y from X, which is the difference in vertical height. According to the amount of posterior maxillary impaction, the change in the occlusal plane angle and incisal inclination was measured. Results: The average posterior maxillary impaction was 2.91 mm and the average change in the occlusal plane angle and incisal inclination was $6.54^{\circ}$after surgery. As a result, each mm of posterior maxillary impaction changed the occlusal plane angle and incisal inclination by $2.25^{\circ}$. Statistically, there was high significance. Two cases were observed: one with the same amount of posterior maxillary impaction performed on both the right and left showing $2.20^{\circ}$, and the other with a different amount of posterior maxillary impaction performed showing $2.35^{\circ}$. In this case, there was no significance difference between the two cases. Conclusion: Each mm of posterior maxillary impaction changes the occlusal plane angle and incisal inclination by an average of $2.25^{\circ}$. In posterior maxillary impaction, there was no significant difference in the amount of change in the occlusal plane angle and incisal inclination regardless of whether there was an equal amount of posterior maxillary impaction on both sides. This study is expected to help in the presurgical orthodontic preparation and presurgical treatment planning.

Reccurent Foreign body Granuloma after Gore-tex Removal in Rhinoplasty (융비술에서 고어텍스 제거 후 발생한 재발성 이물성 육아종의 치험례)

  • Kwon, Soon Geun;You, Young Cheun;Yang, Won Yong;Park, Jun;Kang, Sang Yun
    • Archives of Plastic Surgery
    • /
    • v.35 no.5
    • /
    • pp.611-614
    • /
    • 2008
  • Purpose: Infection, foreign body reaction and decreased volume of implant are common complications after augmentation rhinoplasty with $Gore-tex^{(R)}$ implant. The author experienced two cases of recurrent foreign body granuloma in the patients who underwent $Gore-tex^{(R)}$ removal because of infection after augmentation rhinoplasty. and treated them with complete removal of$Gore-tex^{(R)}$. Methods: Case 1: A 49 year-old female visited our clinic for recurrent foreign body reaction on nasal dorsum and tip area. The patient underwent augmentation rhinoplasty with $Gore-tex^{(R)}$ 3 years ago and implant was removed due to infection 9 months ago. Excision of the granuloma was performed and a piece of foreign body suspicious to be a $Gore-tex^{(R)}$ implant debris was detected under the subcutaneous pocket. The implant fragments were removed and nasalis muscle rotation flap was performed to cover the lesion. The specimen was proved to be $Gore-tex^{(R)}$ in histological study. Case 2: A 31 year-old-male with recurrent foreign body granuloma on the nasal tip area visited our clinic. 10 years ago, the patient had augmentation rhinoplasty with silicone implant and then, he underwent revisional rhinoplasty five times including nasal implant removal, which was performed 9 months ago. The authors excised the granuloma and found a small sized foreign body suspicious to be a $Gore-tex^{(R)}$ implant debris under the granuloma. The foreign body was excised and identified to be $Gore-tex^{(R)}$ in histological study. Results: In both cases, the lesions were healed without any complications and there were no evidences of recurrence up to 6 months of follow-up. Conclusion: The $Gore-tex^{(R)}$ is known to be weak against mechanical force. These properties of $Gore-tex^{(R)}$ make it difficult to remove the implant completely. In the patient who have infection after augmentation rhinoplasty with $Gore-tex^{(R)}$, the operator should take care to perform the complete removal without remaining fragment of the implant.

A Study on Structural Characteristics of Axial Fans Operating Speed Using Finite Element Analysis (유한요소해석을 이용한 축류팬 운전속도별 구조특성에 대한 연구)

  • Kook, Jeong-Keun;Cho, Byung-Kwan
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.22 no.2
    • /
    • pp.593-601
    • /
    • 2021
  • The axial fan is an element of a blower used for ventilation in various industrial fields. Many studies on aerodynamic performance have been conducted to assess axial fans using fluid dynamics. The subject was a large axial fan size, 1800 mm in diameter with 100 horsepower. The blower's axial fan consisted of blades, hubs, hub caps, and bosses are important components. The blade design has a great influence on the aerodynamic performance. 3D point data is extracted using an aerodynamic performance prediction program, and a 3D modeling shape is generated. The blades and hubs, which are important components, can be easily modified if processed by cutting owing to the environment in which blades and hubs are manufactured through die casting or gravity casting. In this study, the structural safety of components and the analysis results of weak areas at the rated operating speed of the axial fan were verified using the maximum stress and safety factor. The tip clearance reflected in the design was the rotation of the blade. To check whether there is interference with other components, the displacement result was derived to verify the structural safety of the axial fan.

Development of Screw-Type Handy Earth Auger for an Improved Digging Efficiency(I) - Design and Manufacture - (토양굴취력이 향상된 스크류형 경량 식혈기 개발(I) - 설계 및 제작 -)

  • Kim, Jin Hyun;Lee, Jae Hyun;Kim, Ki Dong;Ko, Chi Woong;Kim, Dong Geun
    • Journal of agriculture & life science
    • /
    • v.50 no.3
    • /
    • pp.31-41
    • /
    • 2016
  • This study was conducted to develop a handy earth auger for use in sloppy and rugged forest terrains in order to reduce labor cost which comprises a major part of the production costs in forest afforestation projects. The first prototype is developed consist of two parts, the soil-digging screw and the battery power source. The specifications of the first prototype screw are: length of 170mm, a top diameter of 60mm, bottom diameter of 47mm, 23° angle for each helix, and a 50mm awl-head tip. The use of a single line of screw was selected for reduced weight. In addition, a power source of rotary DC Motor(WD-6G2425, WONILL, Korea) with a maximum torque of 30kgf-cm, rotation of 20-30rpm, K6G30C decelerator with a reduction ratio of 30:1 which could be used with no load for 48 was operated. In consideration of its weight, a lithium battery was utilized in line with the goal of developing a lightweight auger. In order to evaluate the performance of the first prototype, test sites were selected as 6 areas. The rotational force was found to be highest in area A(Solid area), followed by areas F(Mounted slope 40° area) and E(Mounted slope 30° area). It was also observed that in general, the rotational force increased along with the increase in soil depth with the maximum rotational force recorded at 10cm.

A Study on Touchless Finger Vein Recognition Robust to the Alignment and Rotation of Finger (손가락 정렬과 회전에 강인한 비 접촉식 손가락 정맥 인식 연구)

  • Park, Kang-Ryoung;Jang, Young-Kyoon;Kang, Byung-Jun
    • The KIPS Transactions:PartB
    • /
    • v.15B no.4
    • /
    • pp.275-284
    • /
    • 2008
  • With increases in recent security requirements, biometric technology such as fingerprints, faces and iris recognitions have been widely used in many applications including door access control, personal authentication for computers, internet banking, automatic teller machines and border-crossing controls. Finger vein recognition uses the unique patterns of finger veins in order to identify individuals at a high level of accuracy. This paper proposes new device and methods for touchless finger vein recognition. This research presents the following five advantages compared to previous works. First, by using a minimal guiding structure for the finger tip, side and the back of finger, we were able to obtain touchless finger vein images without causing much inconvenience to user. Second, by using a hot mirror, which was slanted at the angle of 45 degrees in front of the camera, we were able to reduce the depth of the capturing device. Consequently, it would be possible to use the device in many applications having size limitations such as mobile phones. Third, we used the holistic texture information of the finger veins based on a LBP (Local Binary Pattern) without needing to extract accurate finger vein regions. By using this method, we were able to reduce the effect of non-uniform illumination including shaded and highly saturated areas. Fourth, we enhanced recognition performance by excluding non-finger vein regions. Fifth, when matching the extracted finger vein code with the enrolled one, by using the bit-shift in both the horizontal and vertical directions, we could reduce the authentic variations caused by the translation and rotation of finger. Experimental results showed that the EER (Equal Error Rate) was 0.07423% and the total processing time was 91.4ms.

Finite element analysis of maxillary incisor displacement during en-masse retraction according to orthodontic mini-implant position

  • Song, Jae-Won;Lim, Joong-Ki;Lee, Kee-Joon;Sung, Sang-Jin;Chun, Youn-Sic;Mo, Sung-Seo
    • The korean journal of orthodontics
    • /
    • v.46 no.4
    • /
    • pp.242-252
    • /
    • 2016
  • Objective: Orthodontic mini-implants (OMI) generate various horizontal and vertical force vectors and moments according to their insertion positions. This study aimed to help select ideal biomechanics during maxillary incisor retraction by varying the length in the anterior retraction hook (ARH) and OMI position. Methods: Two extraction models were constructed to analyze the three-dimentional finite element: a first premolar extraction model (Model 1, M1) and a residual 1-mm space post-extraction model (Model 2, M2). The OMI position was set at a height of 8 mm from the arch wire between the second maxillary premolar and the first molar (low OMI traction) or at a 12-mm height in the mesial second maxillary premolar (high OMI traction). Retraction force vectors of 200 g from the ARH (-1, +1, +3, and +6 mm) at low or high OMI traction were resolved into X-, Y-, and Z-axis components. Results: In M1 (low and high OMI traction) and M2 (low OMI traction), the maxillary incisor tip was extruded, but the apex was intruded, and the occlusal plane was rotated clockwise. Significant intrusion and counter-clockwise rotation in the occlusal plane were observed under high OMI traction and -1 mm ARH in M2. Conclusions: This study observed orthodontic tooth movement according to the OMI position and ARH height, and M2 under high OMI traction with short ARH showed retraction with maxillary incisor intrusion.

3D Face Recognition using Longitudinal Section and Transection (종단면과 횡단면을 이용한 3차원 얼굴 인식)

  • 이영학;박건우;이태홍
    • Journal of KIISE:Software and Applications
    • /
    • v.30 no.9
    • /
    • pp.885-893
    • /
    • 2003
  • In this paper, a new practical implementation of a person verification system using features of longitudinal section and transection and other facial, rotation compensated 3D face image, is proposed. The approach works by finding the nose tip that has a protrusion shape on the face. In feature recognition of 3D face image, one has to take into consideration the orientated frontal posture to normalize. Next, the special points in regions, such as nose, eyes and mouth are detected. The depth of nose, the area of nose and the volume of nose based both on the 3 longitudinal section and a transection are calculated. The eye interval and mouth width are also computed. Finally, the 12 features on the face were extracted. The Ll measure for comparing two feature vectors were used, because it is simple and robust. In the experimental results, proposed method achieves recognition rate of 95.5% for the longitudinal section and transection.

Optimal Aerodynamic Design and Performance Analysis for Pitch-Controlled HAWT (가변 피치형 수평축 풍력 터빈의 공력 최적설계 및 피치제어 성능 연구)

  • Ryu, Ki-Wahn
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.35 no.10
    • /
    • pp.891-898
    • /
    • 2007
  • Optimal aerodynamic design for the pitch-controlled horizontal axis wind turbine and its aerodynamic performance for various pitch angles are performed numerically by using the blade element momentum theory. The numerical calculation includes effects such as Prandtl‘s tip loss, airfoil distribution, and wake rotation. Six different airfoils are distributed along the blade span, and the special airfoil i.e. airfoil of 40% thickness ratio is adopted at the hub side to have structural integrity. The nonlinear chord obtained from the optimal design procedure is linearized to decrease the weight and to increase the productivity with very little change of the aerodynamic performance. From the comparisons of the power, thrust, and torque coefficients with corresponding values of different pitch angles, the aerodynamic performance shows delicate changes for just $3^{\circ}$ increase or decrease of the pitch angle. For precisive pitch control, it requires the pitch control algorithm and its drive mechanism below $3^{\circ}$ increment of pitch angle. The maximum torque is generated when the speed ratio is smaller than the designed one.

Pose and Expression Invariant Alignment based Multi-View 3D Face Recognition

  • Ratyal, Naeem;Taj, Imtiaz;Bajwa, Usama;Sajid, Muhammad
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.12 no.10
    • /
    • pp.4903-4929
    • /
    • 2018
  • In this study, a fully automatic pose and expression invariant 3D face alignment algorithm is proposed to handle frontal and profile face images which is based on a two pass course to fine alignment strategy. The first pass of the algorithm coarsely aligns the face images to an intrinsic coordinate system (ICS) through a single 3D rotation and the second pass aligns them at fine level using a minimum nose tip-scanner distance (MNSD) approach. For facial recognition, multi-view faces are synthesized to exploit real 3D information and test the efficacy of the proposed system. Due to optimal separating hyper plane (OSH), Support Vector Machine (SVM) is employed in multi-view face verification (FV) task. In addition, a multi stage unified classifier based face identification (FI) algorithm is employed which combines results from seven base classifiers, two parallel face recognition algorithms and an exponential rank combiner, all in a hierarchical manner. The performance figures of the proposed methodology are corroborated by extensive experiments performed on four benchmark datasets: GavabDB, Bosphorus, UMB-DB and FRGC v2.0. Results show mark improvement in alignment accuracy and recognition rates. Moreover, a computational complexity analysis has been carried out for the proposed algorithm which reveals its superiority in terms of computational efficiency as well.