• Title/Summary/Keyword: Rotation time

Search Result 1,298, Processing Time 0.028 seconds

Electrical Stimulation Can Facilitate Vestibular Compensation Following Unilateral Labyrinthectomy in Rats

  • Park, Byung-Rim;Kim, Jin-Ok;Kim, Min-Sun;Lee, Moon-Young;Kim, Jae-Hyo;Jin, Yuan-Zhe;Choi, Myung-Ae
    • The Korean Journal of Physiology and Pharmacology
    • /
    • v.5 no.2
    • /
    • pp.123-131
    • /
    • 2001
  • To investigate the effects of electrical stimulation on vestibular compensation, which is the recovery of vestibular symptoms following unilateral labyrinthectomy (UL), intermittent electrical stimulation was applied to the injured vestibular portion in Sprague-Dawley rats. Vestibuloocular and vestibulospinal reflexes, electrical activity and expression of c-Fos protein in medial vestibular nuclei (MVN) were measured with time following UL. Spontaneous nystagmus occurred with frequency of $2.9{\pm}0.2$ beats/sec at 2 hours after UL and disappeared after 72 hours. Electrical stimulation decreased the frequency of nystagmus significantly till 24 hours after UL. Roll head deviation was $107{\pm}9.7^{\circ}$ at 2 hours after UL and the deviation was maintained till 72 hours, but electrical stimulation decreased the deviation significantly 6 hours after UL. Resting activity of type I neurons in ipsilateral MVN to the injured vestibular side decreased significantly compared with control at 6 and 24 hours after UL, but the activity of type I neurons was recovered to control level by electrical stimulation at 24 hours after UL. Gain of type I neurons induced by sinusoidal rotation of 0.1 Hz decreased significantly till 24 hours after UL, but electrical stimulation restored the activity at 24 hours. The gain of type II neurons decreased significantly at 6 hours after UL, but electrical stimulation restored the activity. Expression of c-Fos protein was asymmetric between bilateral MVN till 24 hours after UL, but the asymmetry disappeared by electrical stimulation 6 hours after UL. These results suggest that electrical stimulation to the injured vestibular portion facilitates vestibular compensation following UL by restoration of symmetry of neuronal activity between bilateral vestibular nuclei resulting from increased activity in ipsilateral vestibular nuclei to the injured side.

  • PDF

Image Evaluation of Resolution Parameter and Reconstitution Filter in 256 Multi Detector Computed Tomography by Using Head Phantom (256 다중 검출기 전산화단층촬영에서 두개부 전용 팬톰을 이용한 분해능 파라메터와 재구성 필터의 영상 평가)

  • Gu, Bon-Seung;Seoung, Youl-Hun
    • The Journal of the Korea Contents Association
    • /
    • v.11 no.12
    • /
    • pp.814-821
    • /
    • 2011
  • The purpose of this study was to evaluate of resolution parameter and reconstitution filter in the 256 multi detector computed tomography(MDCT) by using the head phantom. We used 256 MDCT, and head phantom of philips system. We evaluated to image quality by using Extended Brilliance Workspace. The protocol were axial scan method with 120 kVp, 0.5 sec of rotation time, 5 mm of slice thickness and increment, 250 mm of field of view(FOV), $512{\times}512$ of matrix size, 1.0 of pitch, $128{\times}0.625$ mm of collimations. The resolution parameter was applied for 'Standard', 'High' and 'Ultrahigh'. The reconstitution filters were changed to seven type of 'A', 'B', 'C', 'D', 'UA', 'UB', 'UC'. The assesment factors of image quality were the uniformity, the noise, the linearity and 50% and 10% of the modulation transfer function(MTF). Finally The good image quality in 'High' resolution parameter showed at the uniformity, the linearity and 50% and 10% of MTF. The 'UA', 'UB' reconstitution filter showed at the good image quality of the uniformity and the noise and 'C' reconstitution filter showed at the same result of the linearity and 50% and 10% of MTF.

IUE SPECTRA OF SEYEERT 1 GALAXY NGC 7469-BLR CHARACTERISTICS OF NGC 7469 (SEYFERT 1 은하 NGC 7469의 IUE SPECTRA-NGC 7469 BLR의 물리적 특성)

  • Son, Dong-Hoon;Hyung, Siek
    • Journal of Astronomy and Space Sciences
    • /
    • v.22 no.3
    • /
    • pp.187-196
    • /
    • 2005
  • From the line ratios of Si III] 1892 to C III] 1909 (Feibelman & Aller 1987), we estimated the BLR electron densities and their changes of Seyfert 1 galaxy NGC 7469 using IUE spectra observed from June 11 to July 29, 1996 (Wanders et al. 1997). We separated blended Si III] and C III] lines using the STARLINK/DIPSO and measured their fluxes within the error of $12.4\%\;and\;6.6\%,$ respectively. Electron density fluctuated from $10^{9.69}\;to\;10^{10.93}$ during about two month period, i.e. 17.3 times density variation within 50 days. We also derived time delays from UV emission line variations .elative to the continuum $(at\;1315{\AA}):$ 2 days for C IV, 4 days for C III], 8 days for Si III]. This suggests that their stratified UV line emission regions are at 0.002 pc, 0.004 pc and 0.006 pc, respectively, from the central region. Based on the BLR sizes and their rotation velocities deduced from the line profiles, we estimate the central black hole mass as about $10^6M_{\odot}$

Transfer System using Radial Electrodynamic Wheel over Conductive Track (래디얼 동전기 휠을 이용한 전도성 트랙 위에서의 이송 시스템)

  • Jung, Kwang Suk
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.11
    • /
    • pp.794-801
    • /
    • 2017
  • When a radial wheel is placed so as to partially overlap a conductive plate and rotated, a lift force is generated on the wheel, a thrust force along the edge, and a lateral force which tends to reduce the overlap region. When several of these wheels are combined, it is possible to realize a system in which the stability of the remaining axes is ensured, except in the traveling direction. To validate the overall characteristics of the multi-wheel system, we propose a transfer system levitated magnetically using radial electrodynamic wheels. The proposed system is floated and propelled by four wheels and arranged in a structure that allows the thrusts generated by the front and rear wheels to offset each other. The dynamic stability of the wheel and the effect of the pole number on the three-axial forces are analyzed by the finite element method. At this time, the thrust and levitation force are strongly coupled, and the only factor affecting them is the wheel rotation speed. Therefore, in order to control these two forces independently, we make use of the fact that the ratio of the thrust to the levitation force is proportional to the velocity and is independent of the size of the gap. The in-plane and out-of-plane motion control of the system is achieved by this control method and compared with the simulation results. The experimental results show that the coupled degrees of freedom can be effectively controlled by the wheel speed alone.

Ligament Injuries of Knee in the Recreational Skiers (스키에 의한 슬관절 인대 손상)

  • Lee Dong Chul;Ko Jin Hyeok;Kim Dong Han
    • Journal of Korean Orthopaedic Sports Medicine
    • /
    • v.2 no.1
    • /
    • pp.37-43
    • /
    • 2003
  • Purpose: This study is to analyse the injury patterns of knee ligament and the factors influencing ligament injuries of knee, and to evaluate the changes of knee function and activity after ski injury. Materials and Methods: Thirty cases of ligament injuries of knee were studied with a questionaire, stress radiographs, magnetic resolution imaging, and physical examination. Mean age was 28.6 years old and mean follow up was 29.6 months. Clinical evaluation of Lysholm knee scoring scale was used for knee function and Tegner activity score was used for activity change after ski injury. Results: The anterior cruciate ligament (ACL) injury accompanied with medial collateral ligament(MCL) injury was most in 11 cases and isolated MCL injury was the next in 9 cases. The common types of injury mechanism were Phantom foot phenomenon (13 cases, 43$\%$) and valgus external rotation injury (12 cases, 40$\%$), which constitute 83$\%$ of all case. At the last follow up, the mean Lysholm score was 93.4 and mean Tegner activity score was 4.2. The reduced Tegner activity score after injury was 1.9. Among several injury groups, the evaluation of knee function and activity was best in the isolated MCL injury group and worst in the ACL injury accompanied with MCL injury group. The factors to influence ski injury were participation to ski class, release of binding, and skiing long time more than 2 hours. Conclusions: Lysholm score at last follow up revealed good grading, but sports activity after ski injury was reduced when compared with pre-injury state. It seems to need a active, systemic sports rehabilitation program after sports injury.

  • PDF

TREATMENT EFFECTS OF $F{\ddot{R}}ANKEL$ FUNCTIONAL REGULATOR III IN MIXED DENTITION CHILDREN WITH ANTERIOR CROSSBITE (혼합치열기 전치부 반대교합 아동에서 $F{\ddot{r}}ankel$ functional regulator III의 치료효과)

  • Park, Jeung-Ah;Yang, Kyu-Ho;Choi, Nam-Ki;Kim, Seon-Mi
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.35 no.4
    • /
    • pp.652-661
    • /
    • 2008
  • The purpose of this study was to evaluate the skeletal and dental effects obtained by the Frankel functional regulator III in growing children with Class III malocclusions. Cephalometric changes in thirty children at the time of mixed dentition malocclusions (initial mean age, $7.9{\pm}1.1$ years; mean treatment duration, $1.5{\pm}0.8$ years) were analysed. The results were as follows : 1. The skeletal effects on the maxilla showed a significant downward displacement whereas forward displacement was not significant in comparison with the control group. 2. The skeletal effects on the mandible showed statistically significant backward and downward displacement. 3. The dental effects showed statistically significant backward movement in the mandibular incisor tip and increase of overjet The results suggested that forward displacement on the maxilla was insufficient and treatment effects were caused mainly by downward displacement of the maxilla, backward and downward rotation of the mandible, and the increase of overjet during short period.

  • PDF

The Types of Secondary School Students' Preconceptions on the Motion of the Earth and the Moon (계통도를 이용한 중.고등학생의 지구와 달의 운동에 관한 개념 유형 연구)

  • Woo, Jong-Ok;Lee, Hang-Ro;Min, Jun-Gyu
    • Journal of The Korean Association For Science Education
    • /
    • v.15 no.4
    • /
    • pp.379-393
    • /
    • 1995
  • In spite of school science learning, the students' conceptions have not been changed easily. Therefore, to make students overcome their non scientific conceptions has been an important issue in science education. The purpose of this study was to identify the conceptions of students and teachers on the motion of the earth and the moon. The instrument was developed for estimating students' understandings of the concepts related to the motion of the earth and the moon. The validity of the instrument was examined by the specialists in Science Educator and Astronomer. At the same time, the two field trials had been executed, and the items were modified. Also, it consists of 12 items including 9 two-tier multiple choice items and 3 multiple choice items. The population of this study consists of 250 eighth-, 299 tenth-, 292 eleventh-grade students, 134 science teachers in secondary school. SPSS/PC+ was adopted for the statistical analysis. The type of misconceptions possessed students were as follows: 1) At 12:00 noon, the sun is directly overhead. 2) First quarter moon is a half of overall surface of the moon. 3) Air don't rotate with the earth surface because it keeps apart from the earth surface. 4) Summer is warmer than winter, because the earth is nearer from the sun in summer. 5) Whenever season is changed, the direction of rotation axis of the earth is changed. 6) The moon is the brightest at the position of new moon, because the distance between the moon and the sun is the shortest and the moon is received strongest sunlight. 7) The moon is not seen at the position of real full moon, because it is covered with shadow of the earth. 8) When the moon is not seen in the earth, sunlight is not reached at the moon. The major findings were as follows : 1) The middle school students had more misconceptions than those of high school students. And female students had more misconceptions than those of male ones. 2) The rate of correct answer and the type of conception in the tenth grade students were very similar with eleventh grade students. 3) The higher cognitive level, the better development of scientific conception and the less misconception. Also, the correlation coefficient between scientific conception score and GALT score was 0.57. 4) The students in scientific part had higher the rate of correct answer than those of students in human part and the former had less misconception than the latter. 5) The rate of correct answer about model and figure items was lower than descriptive ones, because they did not understand about figures itselves. These types of misconceptions will be used for science instruction and studies of other conceptions need.

  • PDF

Determination of Optimum Sterilization Condition for the Production of Retorted Kimchi Soup (레토르트 처리한 김치찌개 제품의 최적 살균조건 결정)

  • Cheon, Hee Soon;Park, Eun-Ji;Cho, Won-Il;Hwang, Keum Taek;Chung, Myong-Soo;Choi, Jun-Bong
    • Culinary science and hospitality research
    • /
    • v.20 no.6
    • /
    • pp.254-261
    • /
    • 2014
  • In order to optimize process conditions for manufacturing retorted Kimchi soup by using stationary and rotary types systems were applied for sterilization process. For investigating the differences in heat penetration characteristics during sterilization, Kimchi soup was packed into retort pouches, and sterility ($F_0$ value) at various positions in the product was measured through a wireless $F_0$ sensor. Heat penetration characteristics were significantly affected by sterilization method. From data analysis, optimum ranges of sterilization temperature and time was determined to be $120.7^{\circ}C$, 13 min for rotary type and $120.7^{\circ}C$, 20 min for stationary type. At those conditions, they had similar sterility ($F_0$ value). The results showed that rotation provides faster heat penetration and more uniform sterility than various positions of the product. These results derived a lot of advantages from related industry. For instance, many of the more viscous semi-liquid products and heat sensitive natural products could be sterilized in the lager pouch sizes without overcooking or scorching. Hence, current study suggests that rotary type retort would make it possible not only to reduce processing times as 35~45%, but also to improve the quality of product as overall taste, flavor, color, and texture with significant difference (p<0.05).

Facial Contour Extraction in Moving Pictures by using DCM mask and Initial Curve Interpolation of Snakes (DCM 마스크와 스네이크의 초기곡선 보간에 의한 동영상에서의 얼굴 윤곽선 추출)

  • Kim Young-Won;Jun Byung-Hwan
    • Journal of the Institute of Electronics Engineers of Korea CI
    • /
    • v.43 no.4 s.310
    • /
    • pp.58-66
    • /
    • 2006
  • In this paper, we apply DCM(Dilation of Color and Motion information) mask and Active Contour Models(Snakes) to extract facial outline in moving pictures with complex background. First, we propose DCM mask which is made by applying morphology dilation and AND operation to combine facial color and motion information, and use this mask to detect facial region without complex background and to remove noise in image energy. Also, initial curves are automatically set according to rotational degree estimated with geometric ratio of facial elements to overcome the demerit of Active Contour Models which is sensitive to initial curves. And edge intensity and brightness are both used as image energy of snakes to extract contour at parts with weak edges. For experiments, we acquired total 480 frames with various head-poses of sixteen persons with both eyes shown by taking pictures in inner space and also by capturing broadcasting images. As a result, it showed that more elaborate facial contour is extracted at average processing time of 0.28 seconds when using interpolated initial curves according to facial rotation degree and using combined image energy of edge intensity and brightness.

Camera Motion Estimation using Geometrically Symmetric Points in Subsequent Video Frames (인접 영상 프레임에서 기하학적 대칭점을 이용한 카메라 움직임 추정)

  • Jeon, Dae-Seong;Mun, Seong-Heon;Park, Jun-Ho;Yun, Yeong-U
    • Journal of the Institute of Electronics Engineers of Korea CI
    • /
    • v.39 no.2
    • /
    • pp.35-44
    • /
    • 2002
  • The translation and the rotation of camera occur global motion which affects all over the frame in video sequence. With the video sequences containing global motion, it is practically impossible to extract exact video objects and to calculate genuine object motions. Therefore, high compression ratio cannot be achieved due to the large motion vectors. This problem can be solved when the global motion compensated frames are used. The existing camera motion estimation methods for global motion compensation have a large amount of computations in common. In this paper, we propose a simple global motion estimation algorithm that consists of linear equations without any repetition. The algorithm uses information .of symmetric points in the frame of the video sequence. The discriminant conditions to distinguish regions belonging to distant view from foreground in the frame are presented. Only for the distant view satisfying the discriminant conditions, the linear equations for the panning, tilting, and zooming parameters are applied. From the experimental results using the MPEG test sequences, we can confirm that the proposed algorithm estimates correct global motion parameters. Moreover the real-time capability of the proposed technique can be applicable to many MPEG-4 and MPEG-7 related areas.