• Title/Summary/Keyword: Rotation performance

Search Result 1,241, Processing Time 0.025 seconds

Comparison of Effects of Manual Therapy Interventions Combined with Exercise on Range of Motion, Muscle Strength, and Functional Performance in Adolescent Baseball Players with Internal Impingement of Shoulder Joint (어깨관절 내적 충돌증후군을 가진 청소년기 야구선수들의 ROM, 근력, 기능수행정도에 미치는 운동과 도수치료를 혼합한 중재들의 효과 비교)

  • Choo, Yeonki
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.8 no.1
    • /
    • pp.101-111
    • /
    • 2020
  • Purpose : The purpose of this study was to identify the comparison of the effects of manual therapy combined with exercise on range of motion (ROM), muscle strength, and functional performance in adolescent baseball players with internal impingement syndrome of the shoulder. Methods : The subjects were 30 patients diagnosed with impingement syndrome of the shoulder. Thirty subjects are randomly assigned to each 3 different groups; Group 1. (exercise group), Group 2. (exercise+mobilization; EMOB group), Group 3. (exercise+mobilization with movement; EMWM group). The interventions were performed three times a week for 4 weeks. The main outcome measures were goniometer, Biodex dynamometer, and Korean Kerlan Jobe shoulder-elbow (K-KJOC) scores. The ROM (external and internal rotation), muscle strength (external and internal rotation: 60 °/sec., 180 °/sec.), and functional performance were compared among the groups. Results : No significant difference was observed among the groups in the range of external rotation of the shoulder before and after the intervention, but the range of internal and total rotation was significantly increased in Group 2, 3 compared to Groups 1. Muscle strength of external and internal rotation (60 °/sec., 180 °/sec.) was not significantly different among Group 1, 2, 3, and functional performance was significantly increased in Group 2, 3 compared to Group 1. However, there was no significant difference between Group 2 and Group 3 in all measurements. Conclusion : An intervention with manual therapy such as EMOB and EMWM was more effective than exercise alone for rapid recovery from shoulder injury and improvement in functional performance. However, further efforts are needed to identify effects of specific interventions with manual therapy.

Performance Appraisal and Job Rotation of the Nurse In a General Hospital (간호사 인사관리 제도에 관한 연구)

  • Kwon, Young-Hee;Lee, Myung-Ha
    • Journal of Korean Academy of Nursing Administration
    • /
    • v.5 no.3
    • /
    • pp.425-444
    • /
    • 1999
  • The purpose of this study is to survey evaluation of the nurse on the current Performance Appraisal System. the need for future performance of the nurse and the opinions about the job rotation, and suggest the direction of improvement by obtaining basic data to improve personnel management of the nurse in a hosipial, the subject of the investigation. The study was conducted self-reporting questionniare survey of 330 nurses working at C hospital located in Chonbuk Province and the data was collected from May 4. 1999 through May 14. The research used measuring instrument developed by researcher for evalution about the present performance appraisal. the need for the future performanc appraisal system and the opinion of job rotaion. The analysis of the collected data was computerized using SPSS/PC+ program, calculated frequency, percentage, the mean and standard deviation and used Pearson, s Correlation Coefficients, t-test, chi- square test. Major findings are as follows. 1) As for the purpose of the current performanc appraisal, the appraiser recognized it as a security of promotion standard, while the employee saw it as a means for control as guidance and supervison of work. 2) With regard to use the result of the present performance appraisal, appraiser picked ambiguous appraisal standard, employees recognized unilateral evaluation of superior eliminated the participation of them as the highest priority. 3) In relation to the current criteria for promotion of the nurse, both appraisers and employees placed more weight on the length of clinical than performance appraisal score. 4) There is much possibility of the appraiser making an error to evaluate considering the length of performance appraisal. 5) Both appraisers and employees indicated that prospective result of performance appraisal should be used for the ability development & motivation of the individual. 6) Concerning employee's participation for performance appraisal both sides wanted by far more participation. 7) Regarding the most ideal appraisal method, both parties favored most the way added up the evaluation of the head nurse and peer review and followed by the manner the revaluation of the head nurse by considering self-evaluation. 8) As to the individual interview after the appraisal, more than 60% of appraisers responded it's not necessary, while above 88.5% of employees answered it is essential so that it is showed significantly difference between the appraisers and the employees. 9) As far as open of the evaluation result is concerned. 75% of the appraiser were against it but 80% of the employee were for it so that it showed significantly between them. The most principal reason that the employee want is that it motivates the individual's ability development and the fairness of the appraisal increases. 10) Whether the periodical rotation is necessary or not, 80% of appraisers and employees answered it's necessary, however, over 70% of them did not want the rotation. 11) Work-group Cohesiveness level within the nursing unit was attentive different from desire of the rotation, that is, the work group cohesiveness level of nurses wanting rotation was significantly lower than that of the group not desiring it.

  • PDF

Kinematic Analysis of Deff Motion in High Bars (철봉운동 Deff 동작의 운동학적 분석)

  • Back, Jin-Ho
    • Korean Journal of Applied Biomechanics
    • /
    • v.16 no.1
    • /
    • pp.55-63
    • /
    • 2006
  • The purpose of this study is to prove the kinematical characteristics of Deff motion, the high bar performance, in terms of flying phases so that we can provide basic sources for improving gymnastic performance. To do this, we selected and analyzed the performance of two athletes who did Deff motion in the high bar competition of male artistic gymnastic in the 22nd Universiade 2003 Daegu. We drew the conclusions from the kinematical factors that were came out through analyzing three-dimensional cinematography of the athletes' movements, by using a high speed video camera. To make a successful performance, a performer releases the bar at a height of a high bar vertically and at a height of 82cm horizontally, and the flying performance should be made without moving forward, as maintaining the proper balance, in order to rise over 118cm high during the flying phase. When the performer is releasing the bar, an increase of the vertical speed in the center of the body and extension of a knee joint and a hip joint contribute to increasing a flying height. And when the moving body is twisted, leaning to left side is caused by the winding movement of a knee joint, which causes an unstable bar grasp. To grasp the bar stably, just before releasing the performer should gain propulsive force from twisting rotation through increasing the speed of shoulder rotation. And before the peak point, the performer should make sure of a body rotation distance over $164^{\circ}$ so that he or she can do an aerial rotary performance smoothly. When grasping the high bar, the center of the body should be above the bar and the angle of shoulder rotation should be maintained close to $540^{\circ}$ simultaneously. he high point performance(S1) has more speed on an ascending phase and less speed on a descending phase than the low point performance (S2). At the peak point, both the rotation angle of the body and that of the shoulder in high point performance are big as well. In conclusion, it is shown that a performer can make a jump toward the high bar easily with the body straight because the performer can hold the upper part of the body erect early in a descending phase.

Performance Analysis of a Rotation-Transform Aided QPSK over Impulsive Noise Using Rieman Integral over Voronoi Cell (보로노이 셀에서 리만 적분을 이용한 임펄스 잡음 환경에서 동작하는 회전 변환 QPSK 기법의 성능 해석)

  • Choi, Byoungjo
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.38A no.3
    • /
    • pp.224-239
    • /
    • 2013
  • An exact performance analysis of an ML detector for a 2-dimensional rotation-transform aided QPSK system operating over an impulsive noise environment is presented using Rieman integrals of a two-dimensional Gaussian Q-function over Voronoi cells. A set of interesting features of the Voronoi cells is also characterised systematically. An optimum rotation angle yielding the minimum BER is also studied. The differences between the proposed exact method and the previous approximate analysis method are investigated in terms of the corresponding BERs and the derived optimum angles.

A Study on the Rotation Accuracy According to Unbalance Variation of High Precision Spindle Unit for Machine Tool (고정밀 회전체의 불평형 변동에 따른 회전정밀도 영향에 관한 연구)

  • Kim, Sang-Hwa;Kim, Byung-Ha;Jin, Yong-Gyoo
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.11 no.3
    • /
    • pp.174-181
    • /
    • 2012
  • The spindle unit is a core part in high precision machine tool. Rotation accuracy of spindle unit is needed for high dignity cutting and improving the performance of machine tool. However, there are many factors to effect to rotational error motion(rotation accuracy). This study studied how rotational error motion is variation when unbalance amount is variation. Rotation accuracy of initial spindle unit is decided depending on parts and assembly such as bearing. When it is rotation, vibration and noise is appeared depending on volume of unbalance amount, so it works to decrease unbalance amount. The purpose of the study tests that unbalance amount how much effects to initial rotation condition. The result of the study shows that accuracy of parts and assembly is highly necessary to reach high rotation accuracy and unbalance amount hardly effects to initial rotation accuracy. However, it shorten spindle's life because vibration and noise is increasing by increasing unbalance amount and we can expect situation that rotation accuracy is falling by long time operation.

A Study on Active SAR Satellite Maneuver Time Reduction through Sequential Rotation (연속회전을 통한 능동 합성개구레이더위성 기동시간 단축 연구)

  • Son, Jun-Won;Park, Young-Woong
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.43 no.7
    • /
    • pp.648-656
    • /
    • 2015
  • Active SAR satellite's main maneuver is roll axis maneuver to change SAR antenna direction. In addition, yaw steering is required to minimize the doppler centroid variation. Thus, it is resonable to assign the torque/momentum capacity mostly to roll axis and then yaw axis. In this case, the pitch axis shows low agility performance. However, due to orbit maintenance, large angle maneuver about pitch axis is sometimes required. In this paper, we study the pitch axis maneuver time reduction through sequential rotation about roll and yaw axis. Since these two axes have high agility performance than pitch axis, maneuver time reduction is possible when large angle rotation about pitch axis is required.

Estimation of Rotation Center and Rotation Angle for Real-time Image Stabilization of Roll Axis. (실시간 회전영상 안정화를 위한 회전중심 및 회전각도 추정 방법)

  • Cho, Jae-Soo;Kim, Do-Jong
    • Proceedings of the KIEE Conference
    • /
    • 2004.11c
    • /
    • pp.153-155
    • /
    • 2004
  • This paper proposes a real-time approach on the rotational motion estimation and correction for the roll stabilization of the sight system. This method first estimates a rotation center by the least-mean square algorithm based on the motion vectors of some feature points. And, then, a rotation angle is searched for a best matching block between a reference block image and seccessive input images using MPC(maximum pixel count) matching criterion. Finally, motion correction is performed by the bilinear interpolation technique. Various computer simulations show that the estimation performance is good and the proposed algorithm is a real-time implementable one to the TMS320C6415(500MHz) DSP.

  • PDF

Effects of rotation speed and time in potentiostatic experiment in seawater for 5083-H116 Al alloy

  • Lee, Seung-Jun;Han, Min-Su;Jang, Seok-Ki;Kim, Seong-Jong
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.38 no.8
    • /
    • pp.974-980
    • /
    • 2014
  • Aluminum acts as sacrificial anode and corrosion protection with Al2O3 formation. If the same current on material for Al ships with steel ships supplies, the more hydrogen would be occurred, that result is bring about over-protection. For this reason, the damage by hydrogen embrittlement leads to the serious accident. In this study, we evaluate electrochemical behavior with rotation speed of 5083-H116 Al alloy material for Al ship in seawater. To examine the electrochemical characteristics with rotation speed and its effects on performance, experiments were conducted at four rotation speed. Results of experiments, the corrosion current density and damage were increased by applying the rotation speed compared to static state.

Basic Study on Quality Evaluation Technique for Peeled Garlics(I) -Rotation sytem for vision-based garlic sorter- (박피 마늘의 품위판정 기술개발에 관한 기초연구(I) -영상식 마늘 선별기용 반전장치 개발-)

  • 이종환;이성범;안청운
    • Journal of Biosystems Engineering
    • /
    • v.26 no.3
    • /
    • pp.271-278
    • /
    • 2001
  • Many workers in the garlic peeling factory are separating the sound peeled garlics from the unpeeled and defective ones in a manual way. In order to reduce the seasonal labor requirement and operating cost, the mechanized garlic sorting system such as the vision-based garlic sorter should be developed. This study was conducted as one of basic studies on developing quality evaluation technique for peeled garlics, especially to developed the system for acquiring the whole surface images of garlics with a CCD camera. The following results were obtained from this study. 1. The belt-type garlic rotation system was devised to apply for the vision-based garlic sorter and was tested to decide the criteria of design and optimum conveying speed. 2. To evaluate the performance of the developed garlic rotation system, feeding rate and rotating rate were measured under the conditions of four experimental factors such as the inclined angle of rotating belt, the inclined angle of feeding belt, the height of plate arrays on feeding belt and the conveying speed of belts. And the capacity of the system according to mixture ratios of peeled garlics and unpeeled garlics was analyzed as a feasibility test. 3. For the inclined angle of rotating belt 20°and height of plate array on feeding belt 22㎜, the maximum rotating rate for garlic samples including unpeeled ones was 81.1% at the conveying speed of 4.2 garlic/sec. And under these condition, the maximum feeding rate was 85% at the inclined angle of feeding belt 6.5°. 4. The capacity of the developed garlic rotation system was almost constant regardless of mixture ratio of peeled garlics and unpeeled garlics and its range was 2.95∼3.92 garlic/sec. At the conveying speed of 4.2 garlic/sec, the capacity of the garlic rotation system was calculated ad 58∼64 kg/hr. 5. To improve performance of the garlic rotation system, it is recommended to develop a device to slide garlics into feeding belt.

  • PDF

A Study of Motor Expertise about Kinematic and Kinetic Characteristics of Lower Extremity in the Seokmun Ilwol Martial Art Yin-yang Bo Gait Pattern (석문일월무예 음양보법의 숙련성에 따른 보행 패턴의 하지 운동학 및 운동역학적 특성)

  • Park, Bok-Hee;Kim, Ky-Hyoung
    • Korean Journal of Applied Biomechanics
    • /
    • v.24 no.3
    • /
    • pp.239-248
    • /
    • 2014
  • The purpose of this study was to quantify kinematic and kinetic characteristics of Yin-yang Bo gait according to their motor expertise, one of the Seokmun Ilwol martial art gait patterns. Yin-yang Bo gait pattern shows initial forefoot contact instead of heel contact, and increased time of stance phase time, internal-external rotation of ankle-knee-hip joints and pelvic. It aims to produce and store the more energy through continuous homeostasis of center of gravity (COG) and performance of stretch-shortening cycle. Some of these characteristics also were similar to the gait modification strategies for reducing knee adduction moment such as toe-out progression, medial thrust, internal rotation of hip joint. To identify the characteristics, four factors of expert Yin-yang Bo gait performance group were compared to that of none expert group; 1) angles of COG displacement and rotation 2) distal joint pre-rotation in internal-external rotation of ankle-knee-hip joints and pelvic, 3) invariability pelvic potential and pelvic segment total energy 4) knee abduction moment. Six healthy(three male) subjects participated in the experiment to perform Yin-yang gait pattern. Three-dimensional and force plate data were collected. Kinematic and kinetic data were compared between two groups using t-tests. Results showed that 1) the peak point of COG internal rotation angle was reduced in expert group, 2) kneeexternal and hip joint -internal and pelvic rotation angle peak frames were more near points in expert group.