• Title/Summary/Keyword: Rotation Operation

Search Result 388, Processing Time 0.022 seconds

The Evaluation of Clinical Prognostic Factors for the Surgically Treated Unstable Ankle Fractures (불안정성 족근관절 골절의 수술적 치료 결과에 영향을 미치는 임상적 예후 인자에 대한 분석)

  • Jung, Hong-Geun;Yoo, Moon-Jib;Yoo, Suk-Joo;Lee, Seong-Chul;Park, Jin-Young;Kim, Tai-Won;Kim, Myung-Ho
    • Journal of Korean Foot and Ankle Society
    • /
    • v.5 no.2
    • /
    • pp.112-119
    • /
    • 2001
  • Purpose: The purpose of this study is to analyze the clinical prognostic factors which may affect the postoperative clinical results of the unstable ankle fractures. Materials and Methods: This study is based on 62 unstable ankle fractures treated by open reduction and internal fixation from May 1994 to June 2000, with a minimum follow-up period of 12 months(range: 13 months-7 years 3 months). The 62 patients were average 39.1 years old with male: female ratio of 41:21. Based on Lauge-Hansen classification, the supination-external rotation type was the most common with 36 (58.1%) cases. The clinical results was assessed by American Orthopaedic Foot and Ankle Society(AOFAS) functional scale. The sex, age, body weight, trauma-operation interval, operation time, cause of injury, fracture type were statistically analyzed as the possible postoperative clinical prognostic factors. Results: Postoperative AOFAS functional scale was average 82.1 points with 22(35.5 %) cases excellent, 12(19.4%) good. 16(25.8%) fair and 12(19.4%) cases poor results. The age and the operation time were found to be statistically significant factors affecting the prognosis(p<0.001). The sex, weight, trauma-operation interval factors did not significantly affect the clinical results. The pronation-external rotation type showed better clinical tendency among the fracture types, but without the statistical significance. Conclusion: The surgically treated unstable ankle fractures in patients whose age was above 41 years old or operation time exceeding 90 minutes showed significantly poor clinical results.

  • PDF

A Study on the Operation Activation for Specialized High Schools in Chungcheongbuk-do (충청북도 전문계 고등학교 운영 활성화 방안 연구)

  • Lee, Sang-Hyuk;Jee, Soon-Duk
    • 대한공업교육학회지
    • /
    • v.32 no.2
    • /
    • pp.47-68
    • /
    • 2007
  • The purpose of this research was on the operation activation for specialized high schools in Chungcheongbuk-do, and conducted a survey of chief teachers of Practical Art Subject and heads of each subjects in 32 specialized high schools in district about the system reform of vocational high school, promotion of characterization for each subject, modification of curriculum, reinforcement of direction guide, of which results were analyzed. Also, another survey of small and middle businesses was conducted to investigate the demand for human resources for industrial businesses in Chungcheongbuk-do and specialized abilities required by companies. Through the study, the reform of operation activation for specialized high schools in Chungcheongbuk-do were suggested as follows. First, Specialized high schools should more focus on educating application of a computer and the basic abilities in foreign language at the request of industry. Second, If more than 80% of vocational high school graduates go to junior colleges or universities, specialized high schools should reform their operation like general high schools. Third, Specialized high schools should expand the operation of customized curriculum for neighboring industry to raise employment rate. Fourth, Specialized high schools in Chungcheongbuk-do should reform their courses which can provide students with fundamental knowledge to work in industry related to BT and IT, as Osong medical complex and Ochang IT industrial complex are expanding gradually. Fifth, Employees in companies should be applied as guest teachers, and the principal should have a right to autonomy to operate their own curriculum. Sixth, 5 years rotation system for public schools should be revised to more than 10 years rotation system for special subjects in specialized high schools. Therefore, teachers will have ownership of the school by the revised system.

Shoulder Joint Range of Motion Change Research Frozen Shoulder Therapy KTO (Korea Traditional Osteopathy) (KTO(Korea Traditional Osteopathy)를 이용한 동결견 치료 시 견관절 가동범위 변화 연구)

  • Byun, Sangjoon;Kang, Cheolho;Choi, Guirack;Hong, Seong Gyun
    • Journal of the Korean Society of Radiology
    • /
    • v.7 no.3
    • /
    • pp.205-211
    • /
    • 2013
  • This study is for patients who are diagnosed with Frozen Shoulder, Korean traditional osteopath (KTO) was applied. The reduction of pain in patients with significant pain relief who studied how to increase the range of motion of the shoulder joint in order to additionally confirm. Consists of a total of 14 subjects, divided into two groups of seven experimental groups and seven control groups was studied. KTO seven patients was performed a total of 10 times seven patients was not performed. Look at each item, if the range of motion of the shoulder joint, The group looked at the changes in the operation value when applying the KTO Flexion (7.33), Extension (10.00), Abduction (8.76), Adduction (9.05), external rotation (8.10), internal rotation (10.00) was changed. The group looked at the changes in the operation value when did not apply the KTO Flexion (7.33), Extension (10.00), Abduction (8.76), Adduction (9.05), external rotation (8.10), internal rotation (10.00) was changed. That you can bring an increase in range of motion of the shoulder Frozen Shoulder Korean traditional osteopathic treatment to patients.

Repair of Unilateral Cleft Lip and Nose: Mulliken's Modification of Rotation Advancement (편측 구순열비의 교정술: Rotation Advancement 원칙에 근거한 Mulliken의 방법)

  • Jung, Young-Soo;Lee, Gyu-Tae;Jung, Hwi-Dong;Mulliken, John B.
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.34 no.2
    • /
    • pp.133-139
    • /
    • 2012
  • This is a review regarding Mulliken's Modification using the Millard rotation-advancement principle for the repair of unilateral complete cleft lip and nasal deformity. All patients underwent prior labionasal adhesion and dentofacial orthopedics with a pin-retained (Latham) appliance used for infants with a cleft of the lip and palate. Technical variations concerning the operation are described. A high rotation and releasing incision in the columella lengthens the medial labial element and produces a symmetric prolabium with minimal transgression of the upper philtral column through the advancement flap. The orbicularis oris muscle is everted, from caudad to cephalad, to form the philtral ridge. A minor variation of unilimb Z-plasty is used to level the cleft side of Cupid's bow handle, and cutaneous closure proceeds superiorly from this junction. The dislocated alar cartilage is visualized though a nostril rim incision and suspended to the ipsilateral upper lateral cartilage. Symmetry of the alar base is addressed in three dimensions, including maneuvers to position the deviated anterior-caudal septum, configure the sill, and efface the lateral vestibular web. The authors believe the technical refinements described herein contribute favorably to the outcome of repair regarding unilateral cleft lip and nasal distortion.

Effect of the Impeller Rotation Speed and Inert Gas Flow Rate on Degassing Rate in the A356 Aluminum Melt (임펠러 회전속도와 불활성 가스 유량이 A356 알루미늄 용탕의 탈가스 속도에 미치는 영향)

  • Hyeok-In Kwon;Hoe-Gyung Jeong;Seong-Il Jeong;Ji-Woo Park;Min-Su Kim
    • Journal of Korea Foundry Society
    • /
    • v.43 no.6
    • /
    • pp.271-278
    • /
    • 2023
  • In the present study, A356 melt degassing experiments were conducted under various impeller rotation speed and inert gas flow rate conditions to determine changes in the melt temperature, composition and density during a degassing treatment. The melt temperature was found to decrease gradually as the degassing time increased, but a clear correlation between the impeller rotation speed or inert gas flow rate and the melt heat loss could not be confirmed. Regardless of the impeller rotation speed or inert gas flow rate, the Mg and Ti contents in the A356 melt scarcely changed, even after degassing for more than 10 minutes, while Sr contents decreased at the maximum degassing rate of 70 ppm. From a quantitative analysis of the degassing rate under each experimental condition based on the hydrogen concentration in the melt derived from the melt density and the degassing model equation, the inert gas flow rate was found to affect the degassing rate rather than the impeller rotation speed under the degassing operation condition employed in the present study.

A Study on Performance analysis of a modified parallel manipulator (수정된 병렬형매니퓰레이터의 성능해석에 관한 연구)

  • 김주영;배재만;박명관
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2000.05a
    • /
    • pp.557-560
    • /
    • 2000
  • The Purpose of this study is analysis of kinematic for a modified manipulator and experimental test to certify auto-balancing operation. The test is carried out as follows. First, we solve the inverse kinematics and then do a closed loop control. Second we confirm translation displacement and rotation angle of a manipulator.

  • PDF

The Modified Phemister Operation with the Suture Anchor Added for the Augmentation of Conoid Ligament in Acute Acromioclavicular Dislocation (견봉쇄골 관절의 급성 탈구에서 원추인대 기능의 강화를 위한 봉합 나사못을 추가한 변형된 Phemister 술식)

  • Moon, Gi-Hyuk;Nam, Il-Hyun;Lee, Yeong-Hyun;Kim, Ki-Choul;Lee, Jae-Hoon;Ahn, Gil-Yeong
    • Clinics in Shoulder and Elbow
    • /
    • v.13 no.1
    • /
    • pp.34-39
    • /
    • 2010
  • Purpose: The purpose of this study was to present methods and results for the modified Phemister operation, with a suture anchor added for augmentation of the conoid ligament in cases of acute dislocation of the acromioclavicular joint. Materials and Methods: We evaluated 14 cases of acute dislocation of the acromioclavicular joint. This included 11 cases of Rockwood type 3, and 3 cases of type 5. The mean age of patients was 45.2 years. We operated on them using an anchor for augmentation of the conoid ligament in the modified Phemister operation. The average follow-up period was 14 months and post-operative clinical analysis was conducted using the Weitzman classification, VAS Score, Constant Score and KSS Score. Results: According to Weitzman scores, 13 cases were evaluated as excellent, and one case was good. They had mean joint ranges of forward elevation of $170.7^{\circ}$, lateral elevation of 166.4, external rotation of 68.2, and internal rotation to the level of T7. The mean VAS Score was 1.9, mean Constant Score 90.8, and the mean KSS Score 91. Radiologic analysis indicated that all cases had a good result. Conclusion: The modified Phemister operation with a suture anchor added for augmentation of the conoid ligament is very effective clinically in acute dislocations of the acromioclavicular joint.

An Efficient OCT Architecture for Image Compression Applications (영상 압축 응용분야를 위한 DCT 아키텍처 개발)

  • Yu, Sung-Wook
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.6
    • /
    • pp.1069-1074
    • /
    • 2008
  • This paper presents an efficient architecture for $2^n$-point DCT algorithm. The proposed approach makes use of the fact that, in most DCT applications, the scaling operation in the DCT unit can be eliminated and combined with the scaling operation in the quantizer unit. This important property is efficiently exploited with the CORDIC(COordinate Rotation DIgital Computer) algorithm to produce a regular architecture suitable for VLSI implementation. Although there have been several attempts to exploit CORDIC algorithm in developing DCT architectures, the proposed approach provides the most efficient way for scaled DCT applications by completely eliminating the scale factor compensation.

Characteristics Analysis of Induction Generator with a Change in Rotor Speed (회전속도 변화에 따른 유도발전기의 특성 해석)

  • Kim, Jong-Gyeum;Park, Young-Jeen;Kim, Il-Jung;Kim, Young-Kuk
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.12
    • /
    • pp.2225-2229
    • /
    • 2011
  • Squirrel cage induction motor is the main driving system of industrial field and familiar with its use in a large variety of applications. However, many engineer are unfamiliar with the induction generator, even though no difference exists between both machines except for the mode of operation. But an induction generator is commonly used for micro & small hydro power applications due to its simplicity, reliability, low cost and robustness. Input and output of induction motor has turned against at the induction generator operation. Rotation speed of induction generator is small faster than induction motor. As output of induction machines increases with the increasement of speed, so loss is same. Actually, generator efficiency is lower than motor at this condition. If induction generator is connected with mechanical load, total efficiency is decreased. In this paper, we analyzed that input, output, torque and efficiency is different from each other above and below synchronous speed.

Performance Prediction of Main Coolant Pump in Integral Reactor SMART (일체형원자로 SMART 냉각재순환펌프의 성능예측)

  • Kim Min-Hwan;Park Jin-Seok;Kim Jong-In
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2001.10a
    • /
    • pp.118-125
    • /
    • 2001
  • The performance prediction of SMART MCP was performed using a computational fluid dynamics code. General capacity-head performance curve of MCP, which is provided to other design branches as design input, was obtained and it showed the typical type of axial pump performance curve. When four MCPs operate in parallel and one of them stops while the others continue to operate, SMART requires reduced power operation. A procedure for predicting the performance of SMART MCP for that case was developed and verified with available experimental data. An analysis based on the developed procedure was performed for two cases; the impeller of sloped MCP is fixed or free to rotate in reverse direction. According to the results, $73\%$ flow rate of normal operation enters the reactor core in the case of the locked impeller. In case of the impeller free rotation, the flow rate entering the reactor core is $62.8\%$.

  • PDF