• 제목/요약/키워드: Rotation Angle

검색결과 1,348건 처리시간 0.028초

고관절 내회전 각도와 단분절 요추 추간판 탈출증 발생 부위의 상관성 분석 (Analysis of relationship between hip internal rotation angle and the level of herniation of lumbar intervertebral disc(HIVD) in single-segment)

  • 김진수;최희승;정윤규;추원정;남항우
    • 척추신경추나의학회지
    • /
    • 제8권1호
    • /
    • pp.39-47
    • /
    • 2013
  • Objectives : The purpose of this study is to find out the relationship between hip internal rotation angle and the level of herniation of lumbar intervertebral disc(HIVD) in single-segment. Methods : We investigated 314 patients (158 male, 156 female) who were diagnosed as herniation of lumbar intervertebral disc(HIVD) in single-segment. We measured 314 patients' hip internal rotation angle and analysed the relationship between the hip internal rotation angle and the level of herniation of lumbar intervertebral disc(HIVD). Results : 1. Among 314 cases, the hip internal rotation angle was different between male and female. Hip internal rotation angle of male was mainly limited and that of female was mainly excessive. 2. Among 314 cases, the normal group, defined as patients who have specific range of hip internal rotation angle(male : $35^{\circ}{\pm}10^{\circ}$, female : $45^{\circ}{\pm}10^{\circ}$), tends to be occurred HIVD at L4/5 level. The limited group, defined as patients who have less angle than normal group, the excessive group, defined as patients who have more angle than normal group, and the complex group, defined as patients who have more angle of one leg and less angle of the other leg than normal group, tend to be occurred HIVD at L5/S1 level(p<0.05). Conclusions : In single-segment lumbar HIVD patients, The normal hip internal rotation angle mainly leads to L4/5 HIVD, while the limited and excessive hip internal rotation angle mainly lead to L5/S1 HIVD.

  • PDF

정강뼈 돌림에 따른 오버테스트의 엉덩관절 모음 각도와 엉덩정강뼈 환 길이의 상관관계 (The Relationship Between Hip Adduction Angle of Ober Test According to Tibial Rotation and Length of the Iliotibial Band)

  • 박주희;이사겸
    • 대한물리의학회지
    • /
    • 제12권1호
    • /
    • pp.43-49
    • /
    • 2017
  • PURPOSE: This study investigated the relationship among hip adduction angle, tibial rotation, and ITB length during an Ober test to determine the most appropriate position for performing the test. METHODS: The study included thirty-nine asymptomatic participants (23 males, 16 females). Their hip adduction angles were measured using the Ober test during three tibial rotation conditions (internal tibial rotation, external rotation, and neutral position). ITB length was calculated by measuring the position of the patella to lateral femoral condyle using ultrasonography (patella-condyle distance; PCD). RESULTS: The relationship among hip adduction angle, tibial rotation, and ITB length was analyzed under the three conditions using the Pearson correlation. The hip adduction angle of the internal tibial rotation, the external rotation, and the neutral position were significantly related to ITB length. Moreover, the hip adduction angle measured during the internal tibial rotation had the highest correlation with ITB length among the three conditions (r=.58, p<.001). CONCLUSION: Internal tibial rotation caused by the Ober test led to increased iliotibial band (ITB) tension and a decreased adduction angle. These findings support that tibial rotation influences the flexibility of ITB. Therefore, therapists should consider the position of the internal tibial rotation when taking measurements using an Ober test.

전방머리자세를 가진 성인들에게 목 돌림 수행 시 시각적 생체되먹임 적용이 목의 가쪽 굽힘 움직임 패턴과 목빗근 근활성도에 미치는 영향 (Effects of Visual Biofeedback on Movement Patterns of Neck Lateral Bending and Muscle Activation of Sternocleidomastoid During Neck Rotation in Adults with Forward Head Posture)

  • 양노열;오재섭
    • 대한물리의학회지
    • /
    • 제9권4호
    • /
    • pp.425-432
    • /
    • 2014
  • PURPOSE: The purpose of this study was to investigate that the differences in sternocleidomastoid muscle activity, neck rotation angle, neck lateral bending angle and neck lateral bending onset time between conditions with and without visual biofeedback during neck rotation. METHODS: Ten male and four female adults with condition of forward head posture were recruited in this study. Subjects conducted to left and right maximal neck rotation under the conditions with and without visual biofeedback. During neck rotation, kinematic data of neck rotation, neck lateral bending movement, and electromyography activities of bilateral sternocleidomastold muscles were collected. Differences in dependent variables between conditions with and without visual biofeedback were analyzed using paired t-test. RESULTS: There were significant decreases in lateral bending angle, while lateral bending movement onset time was delayed significantly when applying visual biofeedback (p<.05). However, there were no significant differences in the activation of left and right sternocleidomastoid muscles and neck rotation angle between conditions with and without visual biofeedback (p>.05). CONCLUSION: These findings suggest that visual biofeedback may be effective for axial rotation of cervical spine during neck rotation in adults with forward head posture.

Immediate Effect of Serratus Posterior Inferior Muscle Direction Taping on Thoracolumbar Junction Rotation Angle During One Arm Lifting in the Quadruped Position

  • Kim, Nu-ri;Ahn, Sun-hee;Gwak, Gyeong-tae;Yoo, Hwa-ik;Kwon, Oh-yun
    • 한국전문물리치료학회지
    • /
    • 제28권3호
    • /
    • pp.227-234
    • /
    • 2021
  • Background: The serratus posterior inferior (SPI) muscle originates from the spinous process of T11-L2 and inserts at the lower border of the 9-12th ribs. This muscle is involved in thoracolumbar rotation and stability. Several positions can be used to improve trunk stability; the quadruped position is a good position for easily maintaining a neutral spine. In particular, during one arm lifting, various muscles act to maintain a neutral trunk position, and the SPI is one of these muscles. If trunk stability is weakened, uncontrolled trunk rotation may occur at this time. Tape can be used to increase trunk stability. There have been no studies on the effect of taping applied to the SPI muscle on thoracolumbar junction (TLJ) stability. Objects: This study compared the TLJ rotation angle between three different conditions (without taping, transverse taping, and SPI muscle direction taping). Methods: Thirty subjects were recruited to the study (18 males and 12 females). The TLJ rotation angle was measured during one arm lifting in a quadruped position (ALQP). Two taping methods (transverse and SPI muscle direction taping) were applied, and the TLJ rotation angle was measured in the same movement. Results: SPI muscle direction taping significantly reduced TLJ rotation compared to that without taping (p < 0.001) and with transverse taping (p < 0.001). There was a significant difference in the TLJ rotation angle between transverse taping and SPI muscle direction taping (p < 0.017). Conclusion: SPI muscle direction taping reduces the TLJ rotation angle during ALQP. Therefore, SPI muscle direction taping is one method to improve TLJ stability and reduce uncontrolled TLJ rotation during ALQP.

Comparative Study of Infraspinatus and Posterior Deltoid Muscle Activation According to Angle of External Rotation of Glenohumeral Joint

  • Yang, Dongseok;Choi, Wonho
    • 국제물리치료학회지
    • /
    • 제11권2호
    • /
    • pp.2071-2076
    • /
    • 2020
  • Background: Based on the understanding of the muscle activation relationship between the infraspinatus and posterior deltoid muscles to according to the angle of motion during external rotation on glenohumeral joint, effective shoulder joint strengthening exercise for the prevention and rehabilitation of shoulder injury due to muscle strength imbalance can be performed by achieving the ideal muscle activity ratio during exercise. Objectives: To compare and analyze the muscle activation changes and activity ratio of the infraspinatus and posterior deltoid muscles according to the glenohumeral external rotation angle. Design: Quasi-randomized trial. Methods: The study included 48 healthy male and female adults who provided informed consent for participation in the study. All the subjects performed isometric glenohumeral external rotation by setting the angle of motion to 30°, 45°, and 60° using a 5 kg resistance weight pulley. On surface electromyography, the differences in muscle activation and activity ratio between the infraspinatus and posterior deltoid muscles were investigated. Results: A significant difference in muscle activation was found in the comparison between the infraspinatus and posterior deltoid muscles according to the glenohumeral external rotation angle (P<.05). The muscle activation levels of the infraspinatus and posterior deltoid muscles were highest at the external rotation angles of 30° and 60°, respectively. The muscle activity ratio between the infraspinatus and posterior deltoid muscles also showed a significant difference (P<.05) and was highest at the shoulder external rotation angle of 30°. Conclusion: The findings of this study suggest that muscle activity is the highest at the shoulder external rotation angle of 30° in healthy individuals.

장력제어를 통한 가변형 탄소나노튜브 공진기에 대한 연구 (Tension Control Tunable Carbon Nanotube Resonator)

  • 최태호;이준하
    • 반도체디스플레이기술학회지
    • /
    • 제12권2호
    • /
    • pp.63-66
    • /
    • 2013
  • Carbon Nanotube have been proposed for use in various applications for electromechanical systems. Nano-electromechanical resonators which provide high frequency resolution and long energy storage time, play an important role in wide area fields of science and engineering. Using the control of tension in carbon nanotube, can be made the tunable resonator. In the study, we analysis the tunable frequency change of resonator by tension changes due to the rotation angles of the single-walled carbon nanotube resonator. The frequency characteristics of a resonator as a function of the rotation angle. The tension was found to decrease with increasing rotation angle, and therefore the resonance frequencies could be changed by controlling the single-walled carbon nanotube rotation angle. The resonance frequencies decreased with increasing angle, and when the rotation angle was greater than $60^{\circ}$, these changes were marked.

Reliability and Validity of Measurement Using Smartphone-Based Goniometer of Tibial External Rotation Angle in Standing Knee Flexion

  • Jeon, In-Cheol;Kwon, Oh-Yun;Weon, Jong-Hyuck;Ha, Sung-Min;Kim, Si-Hyun
    • 한국전문물리치료학회지
    • /
    • 제20권2호
    • /
    • pp.60-68
    • /
    • 2013
  • The purpose of this study was to assess the intra-rater test-retest reliability of tibial external rotation angle measurement using a smartphone-based photographic goniometer, DrGoniometer (DrG) compared to a three-dimensional motion analysis system (Vicon). The current study showed an interchangeable method using DrG to measure the tibial external rotation angle in standing knee flexion at $90^{\circ}$. Twelve healthy subjects participated in this study. A rest session was conducted 30 minutes later for within-day reliability and five days later for between-day intra-rater test-retest reliability. To assess the validity of the measurement using DrG, we used a three dimensional motion analysis system as a gold standard to measure the angle of tibial external rotation. Intra-class correlation coefficient (ICC) and the standard error of measurement (SEM) values were used to determine the within- and between- day intra-rater test-retest reliability of using DrG and a three dimensional motion analysis system. To assess validity, Pearson correlation coefficients were used for two measurement techniques. The measurement for tibial external rotation had high intra-rater test-retest reliability of within-day (ICC=.88) and between-day (ICC=.83) reliability using DrG and of within-day (ICC=.93) and between-day (ICC=.77) reliability using a three-dimentional motion analysis system. Tibial external rotation angle measurement using DrG was highly correlated with those of the three-dimensional motion analysis system (r=.86). These results represented that the tibial external rotation angle measurement using DrG showed acceptable reliability and validity compared with the use of three-dimensional motion analysis system.

만성 요통환자에서 성별에 따른 고관절 내회전 각도의 비교 (Comparison of Hip Internal Rotation Angle in Chronic Low Back Pain Patients According to the Gender)

  • 이재영;한상엽;남항우;정벌;이차로;한상욱
    • 척추신경추나의학회지
    • /
    • 제5권2호
    • /
    • pp.9-16
    • /
    • 2010
  • Objectives : This study is planned to classify different biomechanics of men and women, from the comparison of normal range and hip internal rotation angle in chronic low back pain patients. Methods : We measured the hip internal rotation angle of the 30 men and 30 women patients with low back pain that has been over 3 months in BuCheon Jaseng Hospital of Oriental medicine. We set 35-45 degrees as normal range, and found the patients with exceeding normal range, the patients with normal range, and the patients with under normal range. Results : Men appeared to have less hip internal rotation angle than women. Especially, the men's left hip internal rotation angle was less than normal range. On the other hand, women's right hip internal rotation angle was often larger than normal range which was stastically significant. Conclusions : Contraction of hip external rotation muscle including gluteus maxius muscle and piriformis muscle in men, or relaxation of posterior gluteus medius, gluteus maxius and piriformis muscle with contraction of tensor fasciae latae, a part of hip internal rotation muscle, in women seems to be the basis for biomechanics of chronic low back pain.

  • PDF

Effects of Tensor Fasciae Latae-Iliotibial Band Self-Stretching on Lumbopelvic Movement Patterns During Active Prone Hip Lateral Rotation in Subjects With Lumbar Extension Rotation Syndrome

  • Lim, One-Bin;Yi, Chung-Hwi;Kwon, Oh-Yun;Cynn, Heon-Seock
    • 한국전문물리치료학회지
    • /
    • 제19권4호
    • /
    • pp.61-69
    • /
    • 2012
  • The purpose of this study was to identify the effects of tensor fasciae latae-iliotibial band (TFL-ITB) self-stretching exercise on the lumbopelvic movement patterns during active prone hip lateral rotation (HLR) in subjects with lumbar extension rotation syndrome accompanying TFL-ITB shortness. Eleven subjects (9 male and 2 female) were recruited for the two-week study. A three dimensional ultrasonic motion analysis system was used to measure the lumbopelvic movement patterns. The TFL-ITB length was measured using the modified Ober's test and was expressed as the hip horizontal adduction angle. The subjects were instructed how to perform TFL-ITB self-stretching exercise program at home. A paired t-test was performed to determine the significant difference in the angle of lumbopelvic rotation, movement onset time of lumbopelvic rotation, TFL-ITB length, and LBP intensity before and after the two-week period of performing the TFL-ITB self-stretching exercise. The results showed that after the intervention, the lumbopelvic rotation angle decreased significantly (p<.05), the movement onset time reduced significantly (p<.05), and LBP intensity decreased slightly but not significantly (p=.07). The hip horizontal adduction angle increased significantly (p<.05) after the intervention. These findings indicate that TFL-ITB stretching exercise increased TFL-ITB length, decreased lumbopelvic rotation angle, and delayed the movement onset time of lumbopelvic rotation after two-weeks. In conclusion, the TFL-ITB self-stretching exercise performed over a period of two weeks may be an effective approach for patients with lumbar extension rotation syndrome accompanying TFL-ITB shortness.

Effects of Counter-rotation Position on Knee/Hip Angulation, Center of Mass Inclination, and Edging Angle in Simulated Alpine Skiing

  • Yoon, Sukhoon;Kim, Jin-Hae;Park, Jae-Hyeon;Ryu, Jiseon;Park, Sang-Kyoon;Kim, Joo-Nyeon
    • 한국운동역학회지
    • /
    • 제27권2호
    • /
    • pp.91-97
    • /
    • 2017
  • Objective: To investigate rotation movement of segment for performing each position and its effect on knee/hip angulation, COM inclination, and edging angle changes. Method: Twelve Alpine skiers (age: $25.8{\pm}4.8years$, height: $173.8{\pm}5.9cm$, weight: $71.4{\pm}7.4kg$, length of career: $9.9{\pm}4.6years$) participated in this study. Each skier was asked to perform counter-rotation, neutral, and rotation positions. Results: Shank and thigh were less rotated in the counter-rotation position than in other positions, whereas the trunk and pelvis were more counter-rotated (p<.05). Hip angulation, COM inclination, and edging angle were significantly greater in the counter-rotation position than in other positions (p<.05). Conclusion: Our finding proved that the counter-rotation position increases hip angulation, COM inclination, and edging angle. Consequently, we suggest that skiers should perform counter-rotation of the trunk and pelvis relative to the ski direction in the vertical axis for the counter-rotation position. Further analysis will continue to investigate the effects of the counter-rotation position in real ski slope with kinetic analysis.