• Title/Summary/Keyword: Rotating Pin

Search Result 51, Processing Time 0.024 seconds

An Assessment of Post-Injection Transmission Measurement for Attenuation Correction With Rotating Pin Sources in Positron Emission Tomography (양전자방출단층촬영(PET)에서 회전 핀선원과 투과 및 방출 동시 영상 방법을 이용한 감쇠보정 방법 특성에 관한 고찰)

  • Lee, J.R.;Choi, Y.;Lee, K.H.;Kim, S.E.;Chi, D.Y.;Shin, S.A.;Kim, B.T.
    • The Korean Journal of Nuclear Medicine
    • /
    • v.29 no.4
    • /
    • pp.533-540
    • /
    • 1995
  • Attenuation correction is important in producing quantitative positron emission tomography (PET) images. Conventionally, photon attenuation effects are corrected using transmission measurements performed before tracer administration. The pre-injection transmission measurement approach may require a time delay between transmission and emission scans for the tracer studies requiring a long uptake period, about 45 minutes for F-18 deoxyglucose study. The time delay will limit patient throughput and increase the likelihood of patient motion. A technique lot performing simultaneous transmission and emission scans (T+E method) after the tracer injection has been validated. The T+E method substracts the emission counts contaminating the transmission measurements to produce accurate attenuation correction coefficients. This method has been evaluated in experiments using a cylindrical phantom filled with background water (5750 cc) containing $0.4{\mu}Ci/cc$ of F-18 fluoride ion and one insert cylinder (276 cc) containing $4.3{\mu}Ci/cc$. GE $Advance^{TM}$ PET scanner and Ge-68 rotating pin sources for transmission scanning were used for this investigation. Post-injection transmission scan and emission scan were peformed alternatively over time. The error in emission images corrected using post-infection transmission scan to emission images corrected transmission scan was 2.6% at the concentration of $1.0{\mu}Ci/cc$. No obvious differences in image quality and noise were apparent between the two images. The attenuation correction can be accomplished with post-injection transmission measurement using rotating pin sources and this method can significantly shorten the time between transmission and omission scans and thereby reduce the likelihood of patient motion and increase scanning throughput in PET.

  • PDF

Development of Tactile Display for the Blind in Japan (일본의 시각장애인을 위한 촉각디스플레이 개발)

  • Han, S.M.
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.4 no.1
    • /
    • pp.63-70
    • /
    • 2010
  • Research and development of Assistive Technology (AT) for blind people is primarily focused on assisting mobility and improving access to information. Some particularly useful devices for aiding access to information and communication are DAISY players used with talking books, screen readers for reading screens, video magnifiers to aid low vision, Braille displays, and Braille PDAs. These essential devices have been successfully commercialized and have assisted many visually impaired people. Assistive technology devices for visually impaired people are called sensory substitution devices, because these devices substitute tactile or auditory functions for visual functions. The tactile interfaces of sensory substitution devices such as Braille displays and Braille PDAs have a bimorph type of piezoelectric actuator that forms a Braille (pin) of the Braille cells by moving up and down. KGS Corporation of Japan has more than 80% share of the worldwide market for these Braille cell actuators. Commercializing it for the first time in the world. This paper reviews the various endeavors in Japan in the research and development of tactile displays, such as Braille displays and Braille PDAs. Furthermore, it discusses sensory substitution devices that use tactile displays, focusing especially on the rotating Braille display we have developed.

Measurement of Damping Coefficients of a Squeeze Film Damper with Piston Ring Seal Ends (피스톤 링 실 끝단을 갖는 스퀴즈 필름 댐퍼의 감쇠 계수 측정)

  • Nam Kyu Kim;Yeongchae Song;Tae Ho Kim;Jeonggi Hong;Kyungdae Kang
    • Tribology and Lubricants
    • /
    • v.40 no.2
    • /
    • pp.54-60
    • /
    • 2024
  • This study experimentally identifies the effects of end shape, clearance, total damper length, journal eccentricity ratio, oil supply pressure, and oil flow rate on the damping coefficient of a squeeze film damper (SFD) with piston ring seal ends and a central groove. The SFD is composed of a lubricating fluid flowing between the outer race of a rolling element bearing and cartridge, along with an anti-rotation pin to prevent the rotation of the outer race. The device provides additional viscous damping to a rotating system. Additionally, piston ring seals attached at both ends of the damper increase the damping coefficient of the rotating system by reducing oil leakage. Because these different design conditions affect the damping coefficient of an SFD, we perform experiments including different conditions. Tests show that the damping coefficient increases significantly in the SFD with piston ring seal ends compared with the SFD with open ends. The damping coefficient also increases with increasing total damper length and journal eccentricity ratio, and decreases with increasing clearance. Additionally, in contrast to the trend observed for the SFD with open ends, the damping coefficient for the SFD with piston ring seal ends increases with increasing supply pressure and flow rate as the frequency decreases but shows consistent results as the frequency increases.

Dynamic Behavior Analysis of Reciprocating Compressor Pistons (왕복동형 압축기 피스톤의 동적 거동 해석)

  • 김태종
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.12 no.9
    • /
    • pp.717-724
    • /
    • 2002
  • In this study, a numerical analysis for the piston secondary dynamics of small refrigeration reciprocating compressors is performed. In general, the length of cylinder in this class of compressors is shortened to diminish the frictional losses of the piston-cylinder system. So, the contacting length between piston and cylinder wall is in variable with the rotating crank angle around the BDC of the reciprocating piston. In the problem formulation of the piston dynamics, the change in bearing length of the piston and all corresponding forces and moments are considered in order to determine the piston trajectory, velocity and acceleration at each step. A Newton-Raphson procedure was employed in solving the secondary dynamic equations of the piston. The developed computer program can be used to calculate the entire piston trajectory and the hydrodynamic force and moment as functions of crank angle under compressor running conditions. The results explored the effects of the radial clearance, lubricant viscosity, length of the cylinder wall, and pin location on the stability of the piston.

A study on the operation method of safety device of rotating quick coupler (회전 퀵커플러 안전장치 동작방법 연구)

  • Song, Jong-Won;Song, Chil-Sung
    • Design & Manufacturing
    • /
    • v.15 no.1
    • /
    • pp.8-13
    • /
    • 2021
  • Excavators are construction machines used for digging soil, transporting soil, dismantling buildings and clearing the ground at construction sites. There are various attachments attached to the arm end of the excavator and used for various operations. There are the most common types of buckets attached for excavation and other types of attachments used for foresting, road cleaning, snow removal, and waste disposal. When multiple types of work are done at the same time, several attachments must be replaced and a device called a quick coupler is used to reduce replacement time. Although a quick coupler reduces the replacement time of the Attachment, it is necessary to attach safety devices to prevent unintentional detachment of attached attachments during the operation. To prevent the attachment from leaving or falling regardless of the operator's intention, support is installed in the hook of the bucket pin and controlled through a separate hydraulic cylinder to ensure safety. When attaching an attachment, it shall be attached without any action. This study is intended to verify the design validity of safety devices to prevent falls of attachments occurring at construction sites.

Characteristics of Electric Resistance Heated Surface Friction Spot Welding Process of Copper and Aluminum Dissimilar Metal Sheets (구리와 알루미늄 이종금속 판재간의 전기저항가열 표면마찰 스폿용접 특성)

  • Sun, Xiao-Guang;Jin, In-Tai
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.21 no.8
    • /
    • pp.99-109
    • /
    • 2022
  • In this study, an electric resistance-heated surface friction spot-welding process was proposed and tested for the spot-welding ability of copper and aluminum dissimilar metal sheets using electric resistance heating and surface friction heating. This process has welding variables, such as the current value, energizing cycles, rotational speed, and friction time. The current value and energizing cycle can affect the resistance heat, and the rotational speed of the rotating pin and friction time influence frictional heat generation. Resistance heating before friction heating has a preheating effect on the Cu-Al contact interface and a positive effect on preventing friction heat loss during the friction stage. However, because resistance preheating can soften the copper sheet and affect the contact stress and friction coefficient, it has difficulties that may adversely affect frictional heat generation. Therefore, the optimal combination of welding variables should be determined through simulations and experiments of the spot-welding process to determine the effects of electric resistance preheating on the suggested process. Through this procedure, it is known that the proposed spot-welding process can improve the welding quality during the spot welding of Cu-Al sheets.

Comparison Study of Wear Resistance Among Several Denture Teeth Opposing Various Restorative Materials (대합되는 재료에 따른 합성수지 인공치의 마모저항성에 관한 비교 연구)

  • Park, Young-Bae
    • Journal of Technologic Dentistry
    • /
    • v.31 no.1
    • /
    • pp.63-74
    • /
    • 2009
  • Partial or complete prosthesis is needed when teeth are lost due to various kinds of reason. Artificial teeth recover occlusion instead of natural teeth. Artificial teeth are required of esthetics, fragile resistance and abrasive resistance. Artificial tooth is made of acrylic resin or porcelain. Nowadays, acrylic resin artificial teeth are mainly used. Acrylic resin teeth are occluded with natural teeth, gold alloy, Ni-Cr alloy or porcelain etc. Acrylic resin teeth have similar translucency, gloss of natural teeth. And it has good chemical bond with denture base material, but it has low wear resistance. The aim of this study is to compare wear resistance among several denture teeth(Endura, SR-orthosit-PE, Planustar) and between artificial resin denture teeth and opposing 3 restorative materials(gold, Ni-Cr alloy, porcelain). Wear tests were conducted with a rotating wear testing apparatus(pin-on-disk type wear tester) under conditions of rpm 180, 75 minutes and constant loading of 50N. The upper part was the cusp of maxillary first molar and the lower part was a disk type restorative materials. To make similar oral environment, water was supplied continually. The acrylic resin teeth wear was determined by weighing the cusp each 5 minutes during 75 minutes test. Vicker's hardness tester was used to evaluate the surface hardness of test specimens. The SEM was used to evaluate the wear surfaces. The results were as follows: 1. Wear rates of acrylic resin teeth opposing to the restorative materials were high in order of Porcelain, Gold, Ni-Cr alloy (p<.05). 2. Wear resistance rate opposing to the Porcelain disk, was shown in order of Endura, SR-orthosit-PE, Planustar. The wear rate of opposing to porcelain disk was above two times more than that of other groups (p<.05). 3. Wear resistance rates opposing to the Gold, Ni-Cr alloy disk, was shown in order of Endura, SR-orthosit-PE, Planustar (p<.05). 4. A degree of the surface hardness is directly proportional to the degree of wear resistance. There are statistically significant differences between each groups (p<.05).

  • PDF

Mechanism of a grafting machine using the insertion method (삽접법을 이용한 기계접목 메카니즘 연구)

  • Park, Kyu-Sik;Lee, Ki-Myung;Kim, Joo-Yup
    • Current Research on Agriculture and Life Sciences
    • /
    • v.15
    • /
    • pp.115-122
    • /
    • 1997
  • Grafting is an important skill for the stable supply and production of high quality. However, the shortage of skillful labor has become great difficulty for a mass production of grafting-seedling. In this study, a suitable mechanism for a grafting machine was developed. The following summarize the results of this study: 1. An insertion method was selected for mechanism of the grafting machine without bonding agent, clip, pin. This insertion-grafting method can be applicable to general vegetables and a mass production system. In addition to, this method is suitable for developing the grafting mechanism. 2. Growing point was removed while remaining both cotyledons on rootstock. The productivity of this system was five fold greater than the one of an experienced labor. 3. The rootstock processing was placed on left and scion processing unit was placed on right of the system, then processed rootstock and scion graft by rotating $180^{\circ}$. 4. The efficiency tests on mechanical grafting rate showed 98%.

  • PDF

Smart Decontamination Device for Small-size Radioactive Scrap Metal Waste : Using Abrasion pin in Rotating Magnetic Field and Ultrasonic Wave Cleaner (소형 금속방사성폐기물 제염장치 개발 : 자기장 연삭핀과 초음파 세정기의 응용)

  • Hong, Yong-Ho;Park, Su-Ri;Han, Sang-Wook;Kim, Byung-Jick
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.12 no.1
    • /
    • pp.79-88
    • /
    • 2014
  • We have developed a smart decontamination device for small-size radioactive scrap metal (SSRSM) necessarily generated from nuclear facilities. This is a multi-modal device such as rotation of magnetic field focusing on the region containing the abrasion pins placed around target and ultrasonic cleaner. Additionally, in order to increase the decontamination efficiency we have modified some configuration of the device so that it could work on them evenly and totally. With the Optimal operating for operation of the new device, we tried to decontaminate some various metal selected as a sample during 15 minutes sequentially using each method, magnetic and ultrasonic device. As a result, the range of decontamination factor has been highly increased to 18~56. After decontamination, all samples were found its activity less than background level.

Atmospheric Turbulence Simulator for Adaptive Optics Evaluation on an Optical Test Bench

  • Lee, Jun Ho;Shin, Sunmy;Park, Gyu Nam;Rhee, Hyug-Gyo;Yang, Ho-Soon
    • Current Optics and Photonics
    • /
    • v.1 no.2
    • /
    • pp.107-112
    • /
    • 2017
  • An adaptive optics system can be simulated or analyzed to predict its closed-loop performance. However, this type of prediction based on various assumptions can occasionally produce outcomes which are far from actual experience. Thus, every adaptive optics system is desired to be tested in a closed loop on an optical test bench before its application to a telescope. In the close-loop test bench, we need an atmospheric simulator that simulates atmospheric disturbances, mostly in phase, in terms of spatial and temporal behavior. We report the development of an atmospheric turbulence simulator consisting of two point sources, a commercially available deformable mirror with a $12{\times}12$ actuator array, and two random phase plates. The simulator generates an atmospherically distorted single or binary star with varying stellar magnitudes and angular separations. We conduct a simulation of a binary star by optically combining two point sources mounted on independent precision stages. The light intensity of each source (an LED with a pin hole) is adjustable to the corresponding stellar magnitude, while its angular separation is precisely adjusted by moving the corresponding stage. First, the atmospheric phase disturbance at a single instance, i.e., a phase screen, is generated via a computer simulation based on the thin-layer Kolmogorov atmospheric model and its temporal evolution is predicted based on the frozen flow hypothesis. The deformable mirror is then continuously best-fitted to the time-sequenced phase screens based on the least square method. Similarly, we also implement another simulation by rotating two random phase plates which were manufactured to have atmospheric-disturbance-like residual aberrations. This later method is limited in its ability to simulate atmospheric disturbances, but it is easy and inexpensive to implement. With these two methods, individually or in unison, we can simulate typical atmospheric disturbances observed at the Bohyun Observatory in South Korea, which corresponds to an area from 7 to 15 cm with regard to the Fried parameter at a telescope pupil plane of 500 nm.