• Title/Summary/Keyword: Rotary file

Search Result 109, Processing Time 0.024 seconds

Prevention and Solution of the Fracture of Nickel-Titanium Endodontic Instruments (니켈티타늄 전동파일 파절의 예방 및 처치)

  • Kim, Hyeon-Cheol
    • The Journal of the Korean dental association
    • /
    • v.54 no.8
    • /
    • pp.640-650
    • /
    • 2016
  • Nickel-Titanium (NiTi) rotary instruments have brought a big step toward "efficient" practice of endodontic procedure. The rotary files help clinicians to reduce their working time and also increase the clinical success rate with minimal procedural errors. However, NiTi instruments still have a few drawbacks including unpredictable fatigue fracture. Clinicians may reduce the potential risk of instruments fracture by following some clinical guidelines for rotary instruments. In some clinical cases of instruments fracture, we may try to remove the instruments' fragments or bypass the fragment to reach the apical canal. In some limited cases, the fractured instruments' fragments would not jeopardize the clinical prognosis of root canal treatment. Nevertheless, it is impossible to be overemphasized that the prevention of file fracture is much easier than the removal of fracture fragment. Clinicians need to understand the fracture mechanisms and, in clinic, need to discard the used instruments timely.

  • PDF

Evaluation of apical canal shapes produced sequentially during instrumentation with stainless steel hand and Ni-Ti rotary instruments using Micro-computed tomography (Stainless steel hand file과 Ni-Ti rotary file을 이용한 근관 형성시 근단부 근관 형태의 순차적 변화에 대한 평가)

  • Lee, Woo-Jin;Lee, Jeong-Ho;Chun, Kyung-A;Seo, Min-Seock;Yoo, Yeon-Jee;Baek, Seung-Ho
    • Restorative Dentistry and Endodontics
    • /
    • v.36 no.3
    • /
    • pp.231-237
    • /
    • 2011
  • Objectives: The purpose of this study was to determine the optimal master apical file size with minimal transportation and optimal efficiency in removing infected dentin. We evaluated the transportation of the canal center and the change in untouched areas after sequential preparation with a #25 to #40 file using 3 different instruments: stainless steel K-type (SS K-file) hand file, ProFile and LightSpeed using microcomputed tomography (MCT). Materials and Methods: Thirty extracted human mandibular molars with separated orifices and apical foramens on mesial canals were used. Teeth were randomly divided into three groups: SS K-file, Profile, LightSpeed and the root canals were instrumented using corresponding instruments from #20 to #40. All teeth were scanned with MCT before and after instrumentation. Cross section images were used to evaluate canal transportation and untouched area at 1-, 2-, 3-, and 5- mm level from the apex. Data were statistically analyzed according to 'repeated nested design' and Mann-Whitney test (p = 0.05). Results: In SS K-file group, canal transportation was significantly increased over #30 instrument. In the ProFile group, canal transportation was significantly increased after preparation with the #40 instrument at the 1- and 2- mm levels. LightSpeed group showed better centering ability than ProFile group after preparation with the #40 instrument at the 1 and 2 mm levels. Conclusions: SS K-file, Profile, and LightSpeed showed differences in the degree of apical transportation depending on the size of the master apical file.

Effect of adaptive motion on cyclic fatigue resistance of a nickel titanium instrument designed for retreatment

  • Ozyurek, Taha;Yilmaz, Koray;Uslu, Gulsah
    • Restorative Dentistry and Endodontics
    • /
    • v.42 no.1
    • /
    • pp.34-38
    • /
    • 2017
  • Objectives: The aim of this study was to evaluate the cyclic fatigue resistance of the ProTaper Universal D1 file (Dentsply Maillefer) under continuous and adaptive motion. Materials and Methods: Forty ProTaper Universal D1 files were included in this study. The cyclic fatigue tests were performed using a dynamic cyclic fatigue testing device, which had an artificial stainless steel canal with a $60^{\circ}$ angle of curvature and a 5 mm radius of curvature. The files were randomly divided into two groups (Group 1, Rotary motion; Group 2, Adaptive motion). The time to failure of the files were recorded in seconds. The number of cycles to failure (NCF) was calculated for each group. The data were statistically analyzed using Student's t-test. The statistical significant level was set at p < 0.05. Results: The cyclic fatigue resistance of the adaptive motion group was significantly higher than the rotary motion group (p < 0.05). Conclusion: Within the limitations of the present study, the 'Adaptive motion' significantly increased the resistance of the ProTaper Universal D1 file to cyclic facture.

Comparison of apical extrusion of intracanal bacteria by various glide-path establishing systems: an in vitro study

  • Dagna, Alberto;El Abed, Rashid;Hussain, Sameeha;Abu-Tahun, Ibrahim H;Visai, Livia;Bertoglio, Federico;Bosco, Floriana;Beltrami, Riccardo;Poggio, Claudio;Kim, Hyeon-Cheol
    • Restorative Dentistry and Endodontics
    • /
    • v.42 no.4
    • /
    • pp.316-323
    • /
    • 2017
  • Objectives: This study compared the amount of apically extruded bacteria during the glide-path preparation by using multi-file and single-file glide-path establishing nickel-titanium (NiTi) rotary systems. Materials and Methods: Sixty mandibular first molar teeth were used to prepare the test apparatus. They were decoronated, blocked into glass vials, sterilized in ethylene oxide gas, infected with a pure culture of Enterococcus faecalis, randomly assigned to 5 experimental groups, and then prepared using manual stainless-steel files (group KF) and glide-path establishing NiTi rotary files (group PF with PathFiles, group GF with G-Files, group PG with ProGlider, and group OG with One G). At the end of canal preparation, 0.01 mL NaCl solution was taken from the experimental vials. The suspension was plated on brain heart infusion agar and colonies of bacteria were counted, and the results were given as number of colony-forming units (CFU). Results: The manual instrumentation technique tested in group KF extruded the highest number of bacteria compared to the other 4 groups (p < 0.05). The 4 groups using rotary glide-path establishing instruments extruded similar amounts of bacteria. Conclusions: All glide-path establishment instrument systems tested caused a measurable apical extrusion of bacteria. The manual glide-path preparation showed the highest number of bacteria extruded compared to the other NiTi glide-path establishing instruments.

Incidence of postoperative pain after using single continuous, single reciprocating, and full sequence continuous rotary file system: a prospective randomized clinical trial

  • Umesh Kumar;Pragnesh Parmar;Ruchi Vashisht;Namita Tandon;Charan Kamal Kaur
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • v.23 no.2
    • /
    • pp.91-99
    • /
    • 2023
  • Background: Extrusion of debris is a major factor that results in postoperative pain during root canal treatment with various instruments and instrumentation techniques. Therefore, instrumentation techniques that extrude minimal debris into the periapical area while reducing pain are desirable. This study aimed to compare the incidence of postoperative pain and intake of analgesic medication (frequency and quantity) after endodontic treatment of mandibular posterior teeth using two single files and full-sequence continuous rotary systems with different kinematic motions. Methods: Thirty-five of 105 patients were assigned equally to three groups according to the instrumentation system used: ProTaper Next (PN) X2, 25/06 (Dentsply, Maillefer, Ballaigues, Switzerland), One Shape (OS), #0.25/06 (Micro Mega, Besancon, France), and Wave One Gold (WG), Red - #0.25, 0.07 (Dentsply, Maillefer, Ballaigues, Switzerland). Five specialists were included in this study design; each professional prepared 21 teeth, and randomly selected 7 per instrument system. The VAS sheet ranging from 0 to 10 was used to record the initial and postoperative pains at 24, 48, and 72 h, and 7th day after single visit endodontic treatment in mandibular premolars and molars with a diagnosis of asymptomatic irreversible pulpitis with or without apical periodontitis. Postoperatively, an analgesic, ibuprofen 400 mg was administered for intolerable pain at a dose of 1 tablet for 6 h. The patients were asked over the telephone regarding postoperative pain at intervals of 24, 48, and 72 h, and 7th day using a visual analogue scale. Result: There were no statistically significant differences among the PN, OS, and WG systems (P > 0.05) with regard to the incidence of postoperative pain at any of the four time points assessed. Conclusion: The intensity of postoperative pain, frequency, and analgesic intake were similar across all three types of instrument systems; however, the reciprocating single file (WG) was associated with less postoperative pain than the full sequence continuous rotary file.

The Postprocessor Technology of for 5-axis Control Machining (5축가공을 위한 포스트프로세서 기술)

  • Jung, Hyoun-Chul;Hwang, Jong-Dae;Kim, Sang-Myung;Jung, Yoon-Gyo
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.10 no.2
    • /
    • pp.9-15
    • /
    • 2011
  • In order to develop a practical postprocessor for 5-axis machining, the general equations of numerically controlled (NC) data for 5-axis configurations with not only non-orthogonal rotary axes but also orthogonal rotary axes were exactly expressed by the inverse kinematics, and a Windows-based postprocessor written in Visual Basic was developed according to the proposed algorithm. The developed postprocessor is a general system that suitable for all kinds of 5-axis machine tool with orthogonal and non-orthogonal rotary axes. Through implementation of the developed postprocessor and verification by a cutting simulation and machining experiment, the effectiveness of the proposed algorithm is confirmed. Compatibility is improved by allowing exchange of data formats such as rotational tool center position (RTCP) controlled NC data, vector post NC data, and program object file (POF) cutter location (CL)data, and convenience is increased by adding the function of work-piece origin offset. Consequently, the technology of practical post-processor for 5-axis machining is developed.

Comparative analysis of various corrosive environmental conditions for NiTi rotary files (니켈티타늄 파일의 부식에 영향을 미치는 다양한 환경 조건 비교)

  • Yum, Ji-Wan;Park, Jeong-Kil;Hur, Bock;Kim, Hyeon-Cheol
    • Restorative Dentistry and Endodontics
    • /
    • v.33 no.4
    • /
    • pp.377-388
    • /
    • 2008
  • The aim of the present study is to compare the corrosion tendency using two kinds of NiTi files in the various environmental conditions through the visual examination and electrochemical analysis. ProTaper Universal S2, 21 mm (Dentsply Maillefer, Ballaigues, Switzerland) and Hero 642, 0.06 tapers, size 25, 21 mm (Micromega, Besancon, France) rotary instruments were tested. The instruments were randomly divided into eighteen groups (n = 5) by the immersion temperature, the type of solution, the brand of NiTi rotary instrument and the presence of mechanical loading. Each file was examined at various magnifications using Scanning Electron Microscope (JEOL, Akishima, Tokyo, Japan) equipped with energy dispersive X-ray microanalysis (EDX). EDX was used to determine the components of the endodontic file alloy in corroded and noncorroded areas. The corrosion resistance of unused and used NiTi files after repeated uses in the human teeth was evaluated electrochemically by potentiodynamic polarization test using a potentiostat (Applied Corrosion Monitoring, Cark-in-Cartmel, UK). Solution temperature and chloride ion concentration may affect on passivity of NiTi files. Under the conditions of this in vitro study, the corrosion resistance is slightly increased after clinical use.

MANAGEMENT OF SEPARATED FILE IN THE ROOT CANAL (근관 내 File의 파절 시 대처 방안)

  • Kim, Hye-Jeong;Jang, Hoon-Sang;Park, Se-Hee;Cho, Kyung-Mo;Kim, Jin-Woo
    • Restorative Dentistry and Endodontics
    • /
    • v.31 no.3
    • /
    • pp.161-168
    • /
    • 2006
  • During root canal preparation procedures, the potential for instrument separation is always present. Files, a lentulo, a Gates-Glidden (GG) bur or any manufactured obstruction can be left behind in the canal Nickel-titanium (NiTi) rotary files are in common usage in these days. Despite their undeniable advantages, there is a potential risk of separation within the canals. It is very rapid, unpredictable, and creates a great deal of stress for the practitioner. When an endodontic instrument separates, the best option is to remove it. Ultrasonic instruments and microscopes have improved the success rate for removing separated instruments. But It is difficult and not always possible. Therefore prevention is the key. In this case report, several management methods of separated file in the canal are presented.

Development of a CAD/CAM System for the Die Having Complex Geometric Solid Shape - for Rotary Blade as an Example - (자유곡면물체(自由曲面物體)의 금형설계(金型設計) 및 제작(製作)의 자동화(自動化)를 위한 CAD/DAM - 로우터리 경운(耕耘)날을 중심(中心)으로 -)

  • Kim, Soung Rai;Kim, Ki Dae
    • Korean Journal of Agricultural Science
    • /
    • v.22 no.1
    • /
    • pp.11-23
    • /
    • 1995
  • The CAD/CAM system for the manufacturing automation is the newest technology in mechanical engineering area and becomes the important research subject nowadays. Most of all hardwares and softwares for the CAD/CAM system used in the our manufacturing companies such as automobile company are developed by the foreign country and the purchasing price of them is very expensive but their applicability to a certain area is very limited. This study was conducted to develope a CAD/CAM system for the design and the automatic manufacturing of the iron pattern shaped with 3 - dimensional free curved surface, and to test its applicability to the design and the manufacturing of the rotary blade. The results obtained from the study are as follow; 1. The CAD system which can process graphic procedures from the free curved surface shaped data was developed with personal computer. 2. The CAM main program was developed. This main program could produce CL data from CAD data file by checking the tool interference according to the cutting mode. 3. The sub. program which can simulate the tool trace from the CL data was developed. 4. The post processor for the Deckel FP2NC NC milling machine from CL data file was developed and the sub program could transmit NC program through modem to NC milling machine was developed. 5. The developed CAM system seemed to be applicable to any other system. Because the measuring results of the cross sectional thickness of the plastic model from the manufacturing iron pattern by the system showed that this system could properly check the tool interference. 6. In took 75~90 hours to manufacture two iron patterns of rotary blade. For the sake of convenience in applying to the other systems, this system was developed in BASIC and FORTRAN computer language and minimum portion of machine language as possible.

  • PDF

Cyclic fatigue resistance tests of Nickel-Titanium rotary files using simulated canal and weight loading conditions

  • Cho, Ok-In;Versluis, Antheunis;Cheung, Gary S.P.;Ha, Jung-Hong;Hur, Bock;Kim, Hyeon-Cheol
    • Restorative Dentistry and Endodontics
    • /
    • v.38 no.1
    • /
    • pp.31-35
    • /
    • 2013
  • Objectives: This study compared the cyclic fatigue resistance of nickel-titanium (NiTi) files obtained in a conventional test using a simulated canal with a newly developed method that allows the application of constant fatigue load conditions. Materials and Methods: ProFile and K3 files of #25/.06, #30/.06, and #40/.04 were selected. Two types of testing devices were built to test their fatigue performance. The first (conventional) device prescribed curvature inside a simulated canal (C-test), the second new device exerted a constant load (L-test) whilst allowing any resulting curvature. Ten new instruments of each size and brand were tested with each device. The files were rotated until fracture and the number of cycles to failure (NCF) was determined. The NCF were subjected to one-way ANOVA and Duncan's post-hoc test for each method. Spearman's rank correlation coefficient was computed to examine any association between methods. Results: Spearman's rank correlation coefficient (${\rho}$ = -0.905) showed a significant negative correlation between methods. Groups with significant difference after the L-test divided into 4 clusters, whilst the C-test gave just 2 clusters. From the L-test, considering the negative correlation of NCF, K3 gave a significantly lower fatigue resistance than ProFile as in the C-test. K3 #30/.06 showed a lower fatigue resistance than K3 #25/.06, which was not found by the C-test. Variation in fatigue test methodology resulted in different cyclic fatigue resistance rankings for various NiTi files. Conclusions: The new methodology standardized the load during fatigue testing, allowing determination fatigue behavior under constant load conditions.