• Title/Summary/Keyword: Root dentin

Search Result 265, Processing Time 0.018 seconds

A COMPARATIVE STUDY ON RADIOPACITY OF CANAL FILLING AND RETROGRADE ROOT-END FILLING MATERIALS (근관 충전재 및 치근단 역충전재의 방사선 불투과성에 관한 비교 연구)

  • Kim, Yong-Sang;Kim, Seo-Kyong;Hwang, Yun-Chan;Hwang, In-Nam;Oh, Won-Mann
    • Restorative Dentistry and Endodontics
    • /
    • v.33 no.2
    • /
    • pp.107-114
    • /
    • 2008
  • This study was performed to assess the radiopacity of a variety of canal filling and retrograde root-end filling materials according to the specification concerning root canal obturation materials. Ten materials including Gutta-percha pellets, amalgam, Fuji II LC, $Dyract^{(R)}$ AP, Super $EBA^{(R)}$, $IRM^{(R)}$, AH $26^{(R)}$, $Sealapex^{TM}$, Tubli-$Seal^{TM}$, and dentin were evaluated in this study. In the first part, densitometric reading of an each step of aluminum step wedge on occlusal film were performed at 60 kVp (0.2, 0.3, 0.4 s), 70 kVp (0.2, 0.3, 0.33 s) to decide appropriate voltage and exposure time. In the second part, ten specimens which are 5 mm in diameter and 0.5, 1.0, 1.5, 2.0, 2.5, 3.0 mm in thickness, were fabricated from each material studied. The specimens were radiographed simultaneously with an aluminum step wedge under decided condition (60 kVp, 0.2 s). The mean radiographic density values of the materials were transformed into radiopacity expressed equivalent thickness of aluminum (mm Al). The following results were obtained. 1. Among the various conditions including 0.2 s, 0.3 s, 0.4 s at 60 kVp and 0.2 s, 0.3 s, 0.33 s at 70 kVp, the appropriate voltage and exposure time that meet the requirement of density from 0.5 to 2.0 was 0.2 s at 60 kVp. 2. All of the materials in this study had greater radiopacity than the minimun level recommended by ISO No. 4049 standards. 3. Most of the materials had greater radiopacity than 3 mm Al requirement of ANSI/ADA specification No. 57 (2000) and ISO No. 6876 (2001) standards except for Fuji II LC and Dyract. It suggests that all experimental canal filling and retrograde root-end filling materials have a sufficient radiopacity that meet the requirement concerning root canal obturation materials except for Fuji II LC and Dyract.

A COMPARATIVE STUDY ON RADIOPACITY OF ROOT CANAL SEALERS (근관 전색재의 방사선 불투과성에 관한 비교연구)

  • Kim, Tae-Min;Kim, Seo-Kyoung;Hwang, In-Nam;Hwang, Yun-Chan;Kang, Byung-Cheol;Yoon, Suk-Ja;Lee, Jae-Seo;Oh, Won-Mann
    • Restorative Dentistry and Endodontics
    • /
    • v.34 no.1
    • /
    • pp.61-68
    • /
    • 2009
  • This study was performed to assess the radiopacity of a variety of root canal sealers according to the specification concerning root canal sealers. Ten materials including Tubli-$Seal^{TM}$. Kerr Pulp Canal $Sealer^{TM}$, AH $26^{(R)}$, AH $plus^{(R)}$, AH plus $jet^{TM}$, Ad sea $1^{TM}$. $Sealer^{TM}$, $NOGENOL^{TM}$, ZOB $seal^{TM}$, $Epiphany^{TM}$ and dentin were evaluated in this study. In the first part, densitometric reading of an each step of aluminum step wedge on occlusal film was performed at different voltage and exposure time. In the second part, ten specimens were radiographed simultaneously with an aluminum step wedges on the occlusal films under decided condition. The mean radiographic density values of the materials were transformed into radiopacity expressed equivalent thickness of aluminum (mm Al). The following results were obtained. 1. Among the various conditions, the appropriate voltage and exposure time that meet the requirement density was 60 kVp at 0.2 s 2. All of the materials had greater radiopacity than 3 mm Al requirement of ANSI/ADA specification No. 57 (2000) and ISO No. 6876 (2001) standards. 3. The radiopacity of materials increased as thickness of materials increased. 4. The mm Al value of each specimen at 1mm in thickness has a significant difference in the statistics. It suggests that root canal sealers have a sufficient radiopacity that meet the requirement.

The effects of short-term application of calcium hydroxide on dentin fracture strength (단기간의 수산화 칼슘 적용이 상아질 파절강도에 미치는 영향)

  • Shin, Eun-Jung;Park, Yeong-Joon;Lee, Bin-Na;Jang, Ji-Hyun;Chang, Hoon-Sang;Hwang, In-Nam;Oh, Won-Mann;Hwang, Yun-Chan
    • Restorative Dentistry and Endodontics
    • /
    • v.36 no.5
    • /
    • pp.425-430
    • /
    • 2011
  • Objectives: This in vitro study investigated whether short-term application of calcium hydroxide in the root canal system for 1 and 4 wk affects the fracture strength of human permanent teeth. Materials and Methods: Thirty two mature human single rooted mandibular premolars in similar size and dentin thickness without decay or restorations were hand and rotary instrumented and 16 teeth vertically packed with calcium hydroxide paste and sealed coronally with caviton to imitate the endodontic procedure and the other 16 teeth was left empty as a control group. The apicies of all the samples were sealed with resin, submerged in normal saline and put in a storage box at $37^{\circ}C$ to mimic the oral environment. After 1 and 4 wk, 8 samples out of 16 samples from each group were removed from the storage box and fracture strength test was performed. The maximum load required to fracture the samples was recorded and data were analysed statistically by the two way ANOVA test at 5% significance level. Results: The mean fracture strengths of two groups after 1 wk and 4 wk were similar. The intracanal placement of calcium hydroxide weakened the fracture strength of teeth by 8.2% after 4 wk: an average of 39.23 MPa for no treatment group and 36.01 MPa for CH group. However there was no statistically significant difference between experimental groups and between time intervals. Conclusions: These results suggest that short term calcium hydroxide application is available during endodontic treatment.

Sealing Ability of Root Canals Obturated with Gutta-percha, Epoxy Resin-based Sealer, and Dentin Adhesives (에폭시레진계 봉함제와 상아질접착제로 근관충전시 미세누출에 관한 연구)

  • Kim, Hee-Jung;Baek, Seung-Ho;Bae, Kwang-Shik
    • Restorative Dentistry and Endodontics
    • /
    • v.29 no.1
    • /
    • pp.51-57
    • /
    • 2004
  • 본 연구는 에폭시레진계 봉함제 (AH26)과 두 가지의 상아질 접착제와 함께 근관충전을 시 행하였을 때와 에폭시레진계 봉함제 단독으로 사용하였을 때의 미세누출을 혐기성 세균모델을 이용하여 평가하였다. 52개의 단근치를 이용하여 .04, .06 taper Profile (Dentsply-Maillefer, Ballaigues, Swiss)을 사용하여 변형된 crown-down pressureless법으로 근관형성 하였다. 형성된 치근을 12개씩 무작위로 나누어 4개의 실험군으로 하였으며, 나머지 치아 중 2개를 양성대조군에, 2개는 음성대조군으로 사용하였다. 제1군은 All Bond 2(Bisco, Itasca, IL, USA)를 적용하고 거타퍼쳐와 AH26 (Dentsply, Konstanz, Germany)을 이용하여 continuous wave of condensation technique으로 근관충전 하였으며, 제 2군은Prime & Bond NT (Dentsply, Konstanz, Germany)를 적용 후 거타퍼쳐와 AH26을 이용하여 충전하였으며, 제3군은 17% EDTA를 적용하여 도말층을 제거한 후 거터퍼쳐 와 AH26을 사용하여 충전하였다. 제4군은 17% EDTA를 적용하지 않고 거터퍼쳐와 AH26을 사용하여 충전하였다. Fusobacterium nucleatum (VPI 10197)을 추적자로 이용한 혐기성세균모델을 사용하여 혐기성배양기에서 배양시키면서 60일 동안 각군에 대한 미세누출 여부를 관찰하였다. 매일 배양액의 혼탁도와 색상변화를 관찰하여 기록하였다. 제4군에서 통계학적으로 유의할만한 미세누출을 가장 많이 보였으며(p<0.0005) 나머지 3개의 실험군에서는 서로간의 통계학적으로 유의할 만한 차이를 보이지 않았다. 주사전자현미경 관찰 시 제 1군과 제2군의 상아질 접착제가 상아세관으로 침투한 소견을 관찰 할 수 있었다.

A Study on the Toothbrush-Dentifrice Abrasion of Class V Restroations (치경부 5급 와동 수복의 잇솔질 마모에 관한 연구)

  • Hwang, Su-Jin;Yu, Mi-Kyung;Lee, Kwang-Won
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.21 no.1
    • /
    • pp.69-81
    • /
    • 2005
  • The objective of this study was to evaluate the toothbrush abrasion characteristics of class V restorations. Thirty extracted human premolars, which were collected from oral surgery clinics were used. We mounted five teeth in a metal ring mold of 50 mm in diameter and 15 mm in height using chemically cured acrylic resin. Class V cavities were prepared in lingual cervical root surfaces and restored using one of following restorative materials : Dentin Conditioner/Fuji II LC (Group FL), All Bond II/Z-250 (Group ZT), One-up Bond F/Palfigue Estelite (Group PE), F2000 Primer/Adhesive (Group FT), and Prime & Bond 2.1/Dyract AP (Group DR). They were stored under distilled water at $37^{\circ}C$ for seven days. The toothbrush abrasion test was conducted using a wear testing machine of pin-on disk type under a load of 1.5 N for 100,000 cycles. We have examined the bonded interfaces, the changes of surface roughness and color of abraded surfaces. From this experiment, the following results were obtained. 1. The change of surface roughness showed high degree: RMGIC>compomer>composite resin (p<0.05). 2. Because of the protrusion and missing of filler particles, SEM observation of abraded surfaces of RMGIC and compomers revealed the increase of surface roughness due to the selective removal of matrix resin. 3. The color change by toothbrush abrasion was affected in large part by the change of $L^*$ and $b^*$ of resin composites (p<0.05). 4. The color change by toothbrush abrasion was so small to detect by human eyes. 5. SEM observation of abraded surfaces revealed the interface bonding was the best in the FT group.

Surgical Evaluation of Endodontic Treatments for Apicoectomy According to Alveolar Bone Resorption Types (치조골흡수 유형에 따른 치근단 절제술의 수술적 평가에 관한 연구)

  • Hong, Hyoung Taek;Chun, Heoung Jae
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.26 no.6
    • /
    • pp.471-474
    • /
    • 2013
  • The surgical evaluation of the apicoectomy with various types of alveolar bone resorption was conducted in current study. The apicoectomy is the common and important treatment in endodontics. Finite element analysis was used for evaluation. The 3D solid model of the maxillary central incisor was reconstructed using CT images of a mature Asian female. Loading and boundary conditions were simulated in the normal mastication of maxillary central incisor. For evaluation of apicoectomy, lingual, labial and entire alveolar bone resorption models were developed. In the results, lingual alveolar bone resorption did not significantly influence stress distribution pattern of root dentin and labial alveolar bone had an important role for supporting structural stability in tooth system.

X-LINKED DOMINANT HYPOPHOSPHATAEMIC RICKETS: 13 YEARS FOLLOW-UP STUDY (X 염색체 우성 저인산혈증성 구루병: 13년간의 치험례)

  • Ha, Na;Kim, Youngjin;Kim, Hyunjung;Nam, Soonhyeun
    • The Journal of Korea Assosiation for Disability and Oral Health
    • /
    • v.13 no.1
    • /
    • pp.14-18
    • /
    • 2017
  • X-linked dominant hypophosphataemic rickets(XLHR) is a hereditary disease generally transmitted as an X-linked dominant trait. Oral manifestations include poorly mineralized dentin, enlarged pulp chambers and root canals, early tooth loss. Also, spontaneous dental abscesses could occur in the absence of a history of trauma or caries. This report describes the clinical finding and dental treatment of a child, who came to the hospital for treatment caries but was refered to pediatrics because the child showed clinically short of status, bow-leg and radiographically enlarged pulp chamber and canal, there as diagnosed as XLHR. After the diagnosis, 13 years follow-up and treatment were performed.

Clinical Effect of MS Coat and Elmex gel on the Dentin Hypersensitivity following Periodontal Surgery (치주수술 후 지각과민증에 대한 MS Coat와 엘멕스 겔처치의 임상적 효과)

  • Park, Sung-Min;Lim, Sung-Bin;Chung, Chin-Hyung
    • Journal of Periodontal and Implant Science
    • /
    • v.31 no.4
    • /
    • pp.727-736
    • /
    • 2001
  • Dentinal hypersensitivity is one of the complicated symptom rather than a disease. It has special reaction or pain over uncovered root by heat, mechanical or chemical stimulations, which are normal with healthy teeth, The purpose of this study is to discover rather MS Coat (oxalate-containing pre-polymerized resin suspension) or Elmex gel(amine fluoride+sodium fluoride) is effective on hypersensitivity after periodontal treatment using NRS(Numerica1 Rating Scales), which it is useful for evaluating pain level. This study has been prepared in Dankook Dental Hospital with generally healthy adult who had been suffered from dentinal hypersensitivity after periodontal treatment. Divided in three groups with saline(control group), MS Coat(test 1 group) and Elmex gel(test 2 group). And then, following evaluations were made at the end of 1 minute, 1 week, 1 month and 3 months. 1. The sequence of higher frequency & severeness of hypersensitivity is water within $7^{\circ}C$, air stream & explorer. 2. As time goes on, 1 minute, 1 week, 1 month & 3 months, severeness of hypersensitivity scored lower with water, air stream and explorer. 3. With explorer, the differences among three groups as time had to seen. 4. With air stream, the sensitivity scored lower after 1min with MS Coat, Elmex, and saline sequence. As time goes on the sensitivity was lower with MS Coat and Elmex than saline, but there was no difference between MS Coat and Elmex. 5. With water in $7^{\circ}C$, the sensitivity was much decreasing with MS Coat and Elmex than saline, but there was no difference between MS Coat and Elmex. As the result, MS Coat and Elmex are effective on hypersensitivity caused by periodontal treatment.

  • PDF

WORKING LENGTH CHANGE BY INSTRUMENTATION ACCORDING TO THE CANAL CURVATURE (만곡근관에서 근관형성에 따른 작업장 변화에 관한 연구)

  • Kim, Byung-Hyun;Kim, Young-Sik;Lee, Young-Kyoo
    • Restorative Dentistry and Endodontics
    • /
    • v.24 no.4
    • /
    • pp.623-627
    • /
    • 1999
  • During canal instrumentation of a curved canal, restoring force of endodontic instrument remove more dentin from the inner wall of the curvature. This effect tends to straighten the canal and thus may significantly shorten the working length. This study was to determine the mean reduction in working length after instrumentation according to the curvature. The curvature of mandibular mesial root was determined before instrumentation. 30 canals were divided into 3 groups each 10 on the basis of degree of curvature. Experimental groups as follows. In group 1, canals having curvature from 15 to 20 degrees: in group 2, canals having curvature from 20 to 30degrees; in group 3, canals having curvature above 30 degrees. Experimental teeth in all groups were accessed, and their actual working length determined by passing a size 15 K-file(IAF) just through the minor apical foramen. The canals were sequentially enlarged to size 35 with ProFile .06 series. The change of working length was calculated by measuring the tip of IAF beyond apical foramen by using stereomicroscope. The change of canal curvature following instrumentation were measured using the Schneider technique. The results were as follows. 1. The greatest changes of curvature and working length were observed in the group 3 canals(P<0.05), next were group 2 canals and group 1 canals(P>0.05). 2. Group 1 canals showed a mean reduction in 1.61 degrees and length of 0.12m respectively(P>0.05). 3. Group 2 canals showed a mean reduction in 3.42 degrees(P<0.05) and length of 0.25mm(P>0.05) respectively. 4. Group 3 canals showed a mean reduction in 7.23 degrees(<0.05) and length of 0.64mm respectively(P<0.05).

  • PDF

AMELOGENESIS IMPERFECTA : REPORT OF CASE (법랑질 형성 부전증에 관한 증례 보고)

  • Kim, Jae-Gon;Lee, Young-Su;Her, Sun;Park, Jong-Ha;Baik, Byeong-Ju
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.25 no.3
    • /
    • pp.598-603
    • /
    • 1998
  • Amelogenesis imperfecta is a group of hereditary defects of enamel unassociated with any other generalized defects. The prevalence of this condition has been estimated to range from 1 in 14,000 to 1 in 16,000, depending on the population studied. It may be differentiated into three general types : hypoplastic, hypocalcified, and hypomaturation, depending on the clinical presentation of the defects and the likely stage of enamel formation that is primarily affected. The dentin and root form are usually normal, but the enamel may lack the normal prismatic structure, being laminated throughout its thickness or at the periphery, with the result that these teeth are more resistant to decay. This case is that of an six-year-old girl brought to the pediatric dentistry department by her parents for esthetic reasons and also because of slight dental sensitivity. Clinical and radiographic examinations confirmed amelogenesis imperfecta. The author has treated with the crowning of the primary molars, using prefomed NiCr crowns and periodic fluoride application on whole dentition.

  • PDF