• 제목/요약/키워드: Root canal instrumentation

검색결과 110건 처리시간 0.024초

NiTi Rotary Instrumentation이 근관만곡도 변화에 미치는 영향 (THE EFFECT OF NiTi ROTARY INSTRUMENTATION ON THE CHANGE OF APICAL ROOT CANAL CURVATURE)

  • 임형태;홍찬의;조용범
    • Restorative Dentistry and Endodontics
    • /
    • 제23권1호
    • /
    • pp.257-268
    • /
    • 1998
  • During cleaning and shaping of narrow and curved canals, it is very difficult or nearly impossible to maintain the original canal shape. Procedural accidents such as, ledge, zipping, perforation, and instrument breakage are frequently occurred and even may lead to failure of endodontic therapy. To prevent these kinds of accidents, various instrumentation techniques and materials have been introduced. Recently some nickel titanium (NiTi) files are introduced and it is reported that These NiTi files created rounder preparations with less transportation than conventional instruments in curved canals. This study compared the change of the canal curvature and procedural accidents after instrumentation produced by stainless steel K-flexo file, and NiTi rotary files (Profile 29 and Quantec 2000). Thirty narrow and curved canals (25-45 degree) of extracted human molars were randomly divided into three groups. In group 1, canals were instrumented using a step-back and watch-winding/pull motion with K-flexo files. In group 2, canals were prepared with Profile 29. Group 3, canals were prepared with Quantec 2000 files. Before and after preparation of canals, periapical radiographs were taken and scanned. The change of canal curvature were measured using Photoshop 4.0 program and the incidence of procedural accidents were also evaluated. The results were as follows: 1. All group showed some loss of canal curvature after instrumentation. 2. Average loss of canal curvature was $6.70{\pm}5.31$ degree for group 1, $3.80{\pm}2.57$ degree for group 2, and $5.40{\pm}4.83$ degree for group 3. All group There was significant change in curvature between before and after instrumentation (p<0.05). But there was no statistical difference amoung 3 groups. 3. In group I, there were no procedural accidents, such as ledging, perforation, or instrument fracture. In group 2, two cases of ledge and one case of instrument fracture were produced Goup 3, each one case of ledge, perforation and instrument fracture were occurred. Whthin the limits of above results, It seems that NiTi rotary instrumentation is not All Mighty and if we use uncarefully, it is more dangerous to produce some procedural accidents than conventional hand files. But more studies should be taken to evaluate the exact effects of NiTi rotary instrumentations.

  • PDF

Micro-computed tomographic evaluation of canal retreatments performed by undergraduate students using different techniques

  • Silva, Emmanuel Joao Nogueira Leal;Belladonna, Felipe Goncalves;Carapia, Marianna Fernandes;Muniz, Brenda Leite;Rocha, Mariana Santoro;Moreira, Edson Jorge Lima
    • Restorative Dentistry and Endodontics
    • /
    • 제43권1호
    • /
    • pp.5.1-5.9
    • /
    • 2018
  • Objectives: This study evaluated the amount of remaining root canal filling materials after retreatment procedures performed by undergraduate students using manual, rotary, and reciprocating techniques through micro-computed tomographic analysis. The incidence of instrument fracture and the instrumentation time were also evaluated. Materials and Methods: Thirty maxillary single rooted teeth were prepared with Reciproc R25 files and filled with gutta-percha and AH Plus sealer by the continuous wave of condensation technique. Then, the specimens were assigned to 3 groups (n = 10), according to the retreatment technique used: manual, rotary, and reciprocating groups, which used K-file, Mtwo retreatment file, and Reciproc file, respectively. Retreatments were performed by undergraduate students. The sample was scanned after root canal filling and retreatment procedures, and the images of the canals were examined to quantify the amount of remaining filling material. The incidence of instrument fracture and the instrumentation time were recorded. Results: Remaining filling material was observed in all specimens regardless of the technique used. The mean volume of remaining material was significantly lower in the Reciproc group than in the manual K-file and Mtwo retreatment groups (p < 0.05). The time required to achieve a satisfactory removal of canal filling material and refinement was significantly lower in the Mtwo retreatment and Reciproc groups (p < 0.05) when compared to the manual K-file group. No instrument fracture was observed in any of the groups. Conclusions: Reciproc was the most effective instrument in the removal of canal fillings after retreatments performed by undergraduate students.

Evaluation of canal preparation with Ni-Ti rotary files by micro computed tomography

  • Lee, Jeong-Ho;Kim, Mi-Ja;Seok, Chang-In;Lee, Woo-Cheol;Baek, Seung-Ho
    • Restorative Dentistry and Endodontics
    • /
    • 제29권4호
    • /
    • pp.378-385
    • /
    • 2004
  • The purpose of this study was to compare the effects of preparation with GT files and profiles .04 in shaping of root canals and reconstruct the three-dimensional root canal system using micro computed tomography 40 canals of the extracted human mandibular molars were used, and randomly distributed into two experimental groups. In group 1. canals were prepared by GT files. In group 2, Profiles .04. were used. Apical preparation size was #30. For each tooth pre and post operative cross-sectional images were obtained by the micro CT at 50 micron intervals. Pre and post operative cross-sectional images of 1, 2, 3, 5, and 8mm from the apex were compared. For each section. canal area and centering ratio were determined. For each tooth pre- and post-operative root canal volume from the furcation to the apex of the roots was calculated by three-dimensional image software. Following results were obtained: 1. At 8mm from the apex, area of dentin removed by GT rotary file was significantly larger than that by Profile .04. And at the other levels there was not a significant difference. 2. There was a trend for GT rotary file to remain more centered in the canals than Profile .04 at all levels. But at 3mm level. there was a statistically significant difference. 3. In root canal volume increments after instrumentation, there was no significant difference between two groups.

Micro-computed tomographic assessment of the shaping ability of the One Curve, One Shape, and ProTaper Next nickel-titanium rotary systems

  • Tufenkci, Pelin;Orhan, Kaan;Celikten, Berkan;Bilecenoglu, Burak;Gur, Gurkan;Sevimay, Semra
    • Restorative Dentistry and Endodontics
    • /
    • 제45권3호
    • /
    • pp.30.1-30.11
    • /
    • 2020
  • Objectives: This micro-computed tomographic (CT) study aimed to compare the shaping abilities of ProTaper Next (PTN), One Shape (OS), and One Curve (OC) files in 3-dimensionally (3D)-printed mandibular molars. Materials and Methods: In order to ensure standardization, 3D-printed mandibular molars with a consistent mesiobuccal canal curvature (45°) were used in the present study (n = 18). Specimens were instrumented with the OC, OS, or PTN files. The teeth were scanned pre- and post-instrumentation using micro-CT to detect changes of the canal volume and surface area, as well as to quantify transportation of the canals after instrumentation. Two-way analysis of variance was used for statistical comparisons. Results: No statistically significant differences were found between the OC and OS groups in the changes of the canal volume and surface area before and after instrumentation (p > 0.05). The OC files showed significantly less transportation than the OS or PTN systems for the apical section (p < 0.05). In a comparison of the systems, similar values were found at the coronal and middle levels, without any significant differences (p > 0.05). Conclusions: These 3 instrumentation systems showed similar shaping abilities, although the OC file achieved a lesser extent of transportation in the apical zone than the OS and PTN files. All 3 file systems were confirmed to be safe for use in mandibular mesial canals.

A comparison of shaping ability of four nickel-titanium rotary instruments in simulated root canals

  • Yun, Hyung-Hwa;Park, Jung-Won;Kim, Sung-Kyo
    • 대한치과보존학회:학술대회논문집
    • /
    • 대한치과보존학회 2001년도 추계학술대회(제116회) 및 13회 Workshop 제3회 한ㆍ일 치과보존학회 공동학술대회 초록집
    • /
    • pp.588.1-588
    • /
    • 2001
  • The purpose of this study was to compare the root canal shaping ability of four nickel-titanium rotary instruments. Forty eight simulated curved root canals were instrumented in plastic with the Crown-down technique using the $ProTaper^{TM}$ , the ProFile, the $GT^{TM}$, and the Quantec. Canals were instrumented until apical canal were up to size 30 by one operator. Each instrument was used only once and instrumentation time was measured.(omitted)

  • PDF

Comparison of apical seal with or without the use of dentin adhesive system

  • Lee, Min-Jo;Choi, Kyoung-Kyu;Choi, Gi-Woon
    • 대한치과보존학회:학술대회논문집
    • /
    • 대한치과보존학회 2003년도 제120회 추계학술대회 제 5차 한ㆍ일 치과보존학회 공동학술대회
    • /
    • pp.600-600
    • /
    • 2003
  • I. Objectives Effective endodontic obturation must provide a complete, three-dimensional filling of the root canal system, preventing the communication of fluids between root canal and surrounding periapical tissues. The objective of this study was to compare the apical leakage with or without the use of dentin adhesive system. II. Materials and Methods Forth extracted human teeth with single canals were decoronated. Root canals were instrumented using GT rotary files and Profile .04 file up to #40, 1mm short of the apex. After each instrumentation, copious irrigation with 5.25% sodium hypochlorite solution and confirmation of apical patency were performed.(omitted)

  • PDF

네 가지 전동 Ni-Ti 파일의 danger zone에서의 근관성형력 (Shaping Ability of Four Rotary Nickel-Titanium Instruments to Prepare Root Canal at Danger Zone)

  • 최석동;진명욱;김기옥;김성교
    • Restorative Dentistry and Endodontics
    • /
    • 제29권5호
    • /
    • pp.446-453
    • /
    • 2004
  • 하악 대구치 근심치근의 danger zone에서 수종의 전동 니켈-티타늄 파일의 근관성형력을 근관성형 전후 치질 두께의 변화를 측정하여 평가하고자 하였다. 기구에 따라 총 40개의 하악 대구치를 10개씩 $Profile^{\circledR}$, GT Rotary file, Quantec 및 ProTaper 4개 군으로 나누고 각 치아당 2개의 근관을 straight up-and-down과 anticurvature 군으로 나누어 근단부 근관을 모두 30번 크기로 일정하게 확대하였다. 수정된 Bramante법을 사용하였으며 술전 및 술후의 근관 상아질 두께를 치수저 하방 1, 3 및 5 mm지점에서 측정, 이원변량분석법으로 통계분석하였다. 모든 군의 danger zone과 safe zone에서의 straight up-and-down 동작과 anticurvature 동작 사이에는 치근상아질 두께변화에 현저한 차이를 나타내지 않았다 (p > 0.05). ProTaper는 danger zone과 safe zone 모두에서 다른 기구에 비해 많은 량의 근관상아질 삭제를 보였으며 특히 분지부 3 mm 수준에서 현저하였다(p < 0.05).

근관처치시(根管處置時) 근관면(根管面)에 일어나는 미세구조(微細構造)의 변화(變化)에 관(關)한 연구(硏究) (A STUDY ON THE MICROSCOPIC CHANGE OF THE CANAL WALL AFTER CANAL TREATMENT)

  • 강명회
    • Restorative Dentistry and Endodontics
    • /
    • 제6권1호
    • /
    • pp.51-62
    • /
    • 1980
  • A Scanning Electron Microscope study was conducted to compare the effectiveness of mechanical preparation of the root canal in conjunction with a few number of canal irrigants that have been widely used for canal treatment. The irrigants used in this study were 5% sodium hypochlorite, 3% hydrogen peroxide, 15% EDTA, and 30% hydrochloric acid. The root canals of 84 freshly extracted teeth with single or multi root were conventionally prepared with Hedstroem files. 78 canals were irrigated with normal saline solution following each instrument number and 6 canals were prepared without irrigation. After instrumentation 72 canals were flushed with various irrigants for predetermined length of time as shown on the Table 1. Additional 20 teeth were kept uninstrumented and five of them were immersed in 15% EDTA for 5 minutes, five in 5% sodium hypochlorite for 5 minutes, five in 3% hydrogen peroxide for 20 minutes, and the last five were only rinsed with saline solution. The SEM examination revealed as follows: 1. The canal wall cannot be thoroughly prepared by means of files. 2. No typical structural changes occured on instrumented dentin surface by saline solution, 3% $H_2O_2$, 5% NaOCl, within 5 minutes. 3. 5% NaOCl Solution showed excellent solvent effect to organic substances in uninstrumented canal within 5 minutes and 15% EDTA and 3% $H_2O_2$ showed unsignificant changes. 4. 15% EDTA and 30% HCl dissolved calcified debris and dentin chips that obturated the dentinal tubules and showed patent orifices. 5. 15% EDTA affected on peritubular dentin more readily and showed concavity around dentinal tubules.

  • PDF

전동 file을 장착한 Tri Auto ZX®의 치근단공 인지 정확도 평가 (ACCURACY OF TRI AUTO ZX® IN LOCATING APICAL FORAMEN WITH ROTARY FILE)

  • 박정원
    • Restorative Dentistry and Endodontics
    • /
    • 제24권4호
    • /
    • pp.578-584
    • /
    • 1999
  • The purpose of this experiment was to determine: (1) the safe automatic apical reverse setting that prevents overinstrumentation of the root canal, using Tri Auto ZX$^{(R)}$ and (2) the effect of various irrigant on such instrumentation. The instrumentation was carried out with the automatic apical reverse setting of 0.5, 1.0, 1.5, and 2.0. The root canal irrigants used in usual manner were normal saline(0.9%), NaOCl(2.5%), and RC Prep$^{(R)}$. For each reverse setting and each irrigant, ten teeth were used with the total of 120 teeth. The distance between the file tip and the apical constriction was determined by stereomicroscope using the point that the file began to rotate in reverse direction. When the reverse setting mode was set to 0.5, 18 of 30 were overinstrumented. If these were discriminated by irrigant, 10 of 6 with 0.9% saline, 10 of 6 with NaOCl, and 10 of 6 with RC Prep$^{(R)}$ has the file tip located 0.57${\pm}$0.30mm, 0.73${\pm}$0.39mm, and 0.26${\pm}$0.25mm beyond the apical constriction respectively. In 1.0 setting 15 of 29 were over the apical constriction, and the distribution was 6 in saline, 5 in NaOCl, and 4 in RC Prep$^{(R)}$. The mean distance over the apical constriction was 0.28${\pm}$0.13mm with saline, 0.75${\pm}$0.61mm with NaOCl, and 0.25${\pm}$0.17mm with RC Prep$^{(R)}$. When the autoatic reverse mode was set to 1.5, and 2.0, 5, and 1 teeth were found to be overinstrumented in respective settings. But there were large variations in overinstrumented distances when an attempt was made to compare the effect of irrigants on this overinstrumentations and they were meaningless for the small sample size. When all of the autoreverse setting were combined to compare the number of overinstrumented teeth with each irrigant, there were no significant differences (14 for normal saline, 12 for NaOCl, 13 for RC Prep$^{(R)}$). When 0.5 or 1.0 automatic apical reverse setting mode was used the Tri Auto ZX$^{(R)}$ in clinical application, the possibility of overinstrumentation beyond the apical constriction exists in 55.9% of cases. Therefore 1.5 or 2.0 setting is safer for the preparation inside the canal but this type setting needs additional apical hand preparation of the root canal because the accuracy is lower than 0.5 or 1.0 setting.

  • PDF

Effect of passive ultrasonic agitation during final irrigation on cleaning capacity of hybrid instrumentation

  • Vinhorte, Marcilene Coelho;Eduardo Hideki, Suzuki;Maira Sousa, De Carvalho;Andre Augusto Franco, Marques;Emilio Carlos Junior, Sponchiado;Lucas Da Fonseca Roberti, Garcia
    • Restorative Dentistry and Endodontics
    • /
    • 제39권2호
    • /
    • pp.104-108
    • /
    • 2014
  • Objectives: To evaluate the effect of passive ultrasonic agitation on the cleaning capacity of a hybrid instrumentation technique. Materials and Methods: Twenty mandibular incisors with mesiodistal-flattened root shape had their crowns sectioned at 1 mm from the cementoenamel junction. Instrumentation was initiated by catheterization with K-type files (Denstply Maillefer) #10, #15, and #20 at 3 mm from the working length. Cervical preparation was performed with Largo bur #1 (Dentsply Maillefer) followed by apical instrumentation with K-type files #15, #20 and #25, and finishing with ProTaper F2 file (Denstply Maillefer). All files were used up to the working length under irrigation with 1 mL of 2.5% sodium hypochlorite (Biodyn$\hat{a}$mica) at each instrument change. At the end of instrumentation, the roots were randomly separated into 2 groups (n = 10). All specimens received final irrigation with 1 mL of 2.5% sodium hypochlorite. The solution remained in the root canals in Group 1 for one minute; and ultrasonic agitation was performed in Group 2 for one minute using a straight tip inserted at 1 mm from working length. The specimens were processed histologically and the sections were analyzed under optic microscope (x64) to quantify debris present in the root canal. Results: The samples submitted to ultrasonic agitation (Group 2) presented significant decrease in the amount of debris in comparison with those of Group 1 (p < 0.05). Conclusions: The hybrid instrumentation technique associated with passive ultrasonic agitation promoted greater debris removal in the apical third of the root canals.