• Title/Summary/Keyword: Root canal

Search Result 883, Processing Time 0.018 seconds

MEASUREMENT OF PULPAL BLOOD FLOW USING A LASER DOPPLER FLOWMETER (Laser Doppler flowmeter를 이용한 치수혈류 측정)

  • Ban, Tae-Whan;Lee, Jae-Sang;Kim, Sung-Kyo
    • Restorative Dentistry and Endodontics
    • /
    • v.24 no.4
    • /
    • pp.560-569
    • /
    • 1999
  • Blood supply rather than nerve supply implies pulp vitality. To evaluate pulp vitality clinically, electric pulp test and thermal test which are based on sensory nerve response have been used in addition to many auxiliary data such as past dental history, visual inspection, radiographic examination, percussion, palpation and transillumination test. However, reactivity of the nerves to the stimulation is not synonymous with normalcy. Therefore measurement of pulpal blood flow using a laser Doppler flowmeter became a new trial to test the pulp vitality. The purpose of the present study was to evaluate normal pulpal blood flow level of maxillary teeth in adult to provide a guideline in determining the vitality of dental pulp. Pulpal blood flow was measured in maxillary central and lateral incisors, canines, first and second premolars and first molars of seventy nine adults of 22 - 30 years old using a laser Doppler flowmeter (PeriFlux 4001, Perimed Co., Stockholm, Sweden, 780 nm infrared laser, 1mW). For directly-made splints, silicone rubber impressions were taken directly from the mouth. For indirectly-made splints, alginate impressions were taken from the mouth and stone cast were made. After making depressions on the buccal surfaces of the cast teeth to indicate the hole positions, second impressions with vinyl polysyloxane putty were taken from the cast. Holes for the laser probes were made at the putty impressions 4mm above the gingival level. Laser probe (PF416 dental probe, 1.5mm) was inserted in the prepared hole and the splint was set in the mouth. After 10 minutes of patient relaxing, pulpal blood flow was recorded for 5 minutes on each tooth. The recorded flow was saved in the computer and calculated with a software 'Perisoft' version 5.1. Pulpal blood flow was also recorded in six teeth of five individuals with no response to electric pulp test and cold test, with periapical radiolucency, or with history of root canal treatment to compare with nonvital teeth. The difference between the mean flow values of each group of teeth were analyzed using one-way ANOVA and Duncan's Multiple Range test. The results were as follows: 1. The average pulpal blood flow values of all the tested teeth of each location were between 9 - 16 Perfusion Unit. Pulpal blood flow value was highest in maxillary lateral incisors, followed by first premolars, second premolars, canines, central incisors, and then first molars (p<0.01). 2. In six anterior teeth, indirectly-made splint group showed higher pulpal blood flow values than directly-made splint group (p<0.01). In posterior teeth, however, there was no significant flow value difference between directly-made splint group and indirectly-made splint one (p>0.05). 3. Teeth with vital pulps showed higher signal values than teeth with nonvital pulps (p<0.01), and the flow photographs showed heartbeat-synchronous fluctuations and vasomotions, while those were absent in non vital tooth.

  • PDF

A Radiologic Study of the Relationship of the Maxillary Sinus Floor and Apex of the Maxillary Molar (상악동 아래벽과 상악 대구치 치근사이 위치관계에 관한 방사선학적 연구)

  • Yoon Hae-Rym;Park Chang-Seo
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.28 no.1
    • /
    • pp.111-126
    • /
    • 1998
  • In this study, radiographic evaluation was made using panoramic radiography and cross-sectional tomography of SCANORA/sup (R)/ in male and female adults in their 20's on the relationship between the maxillary sinus floor and the apex of the maxillary molar, to test the accuracy and effectiveness of the cross-sectional tomography, and to use this information in the assessment of preop. and postop. root canal treatment, apical surgery, extraction and implantology. Forty-one adults with an average age of 24.4 years were studied using panoramic radiography and cross-sectional tomography. In panoramic view and cross-sectional view, the position of the apices of maxillary molars were classified as separated, contacted, or protruded type; the general shape of the maxillary sinus floor was evaluated horizontally and vertically from cross-sectional tomography. The accuracy of each radiography was tested using maxilla from 5 fresh cadavers from the Anatomy Lab at Yonsei University Dental College, and panoramic view and cross-sectional tomography were taken in the same condition as with the patients. The results were as follows: 1. Panoramic view and cross-sectional view were taken in the maxilla specimen, and the actual distance between the maxillary sinus floor and the tooth apices were measured in the specimen; the median values of the distance from the tooth apices to the maxillary sinus floor in the panoramic view, cross-sectional view and in the actual maxilla specimen were 2.83 mm, 4.51mm, and 4.l5mm, respectively. In the cross-sectional view, the measured distance was close to the actual distance but in the panoramic view, the measured distance was far from the actual distance. 2. When the results of the panoramic view and cross-sectional view were compared, 40.5% of the results agreed with each other in the two radiographic methods and buccal roots of the 2nd molar were the closest to the maxillary sinus floor in the cross-sectional tomography. 3. In cross-sectional view, when the vertical relationship of the maxillary sinus floor and maxillary roots was assessed, in 1st molars, type II (the sinus floor that extends down to the buccolingual furcation area) was predominant, while in 2nd molars, type I (the sinus floor located above the level connecting the buccal and lingual apices) was predominant. In the horizontal relationship, in 1st molars, type II (the lowest floor of the maxillary sinus located in between the buccal and lingual roots) was predominant; in 2nd molars, type I (the lowest floor of the maxillary sinus located on the buccal side of the buccal roots) and type II appeared in similar frequency. In conclusion, the SCANORA/sup (R)/ cross-sectional tomography was more effective than the frequently used panoramic view, in that the relationship of the maxillary molars and maxillary sinus floor can be evaluated more accurately and the buccolingual cross-sectional view can also be observed. And maxillary sinus floor that was close to maxillary 2nd molar had tendency to be located on buccal side than that close to 1st molar. Therefore, cross-sectional tomography is an effective and accurate method to evaluate the position of the teeth in relation to the sinus floor preoperative and can be easily used to diagnose localized periapical lesions. Also, the image quality obtained was quite satisfactory.

  • PDF

FINITE ELEMENT ANALYSIS OF MAXILLARY CENTRAL INCISORS RESTORED WITH VARIOUS POST-AND-CORE APPLICATIONS (여러가지 post-and-core로 수복된 상악 중절치의 유한요소법적 연구)

  • Seo, Min-Seock;Shon, Won-Jun;Lee, Woo-Cheol;Yoo, Hyun-Mi;Cho, Byeong-Hoon;Baek, Seung-Ho
    • Restorative Dentistry and Endodontics
    • /
    • v.34 no.4
    • /
    • pp.324-332
    • /
    • 2009
  • The purpose of this study was to investigate the effect of rigidity of post core systems on stress distribution by the theoretical technique, finite element stress-analysis method. Three-dimensional finite element models simulating an endodontically treated maxillary central incisor restored with a zirconia ceramic crown were prepared and 1.5 mm ferrule height was provided. Each model contained cortical bone, trabecular bone, periodontal ligament, 4 mm apical root canal filling, and post-and-core. Six combinations of three parallel type post (zirconia ceramic, glass fiber, and stainless steel) and two core (Paracore and Tetric ceram) materials were evaluated, respectively. A 50 N static occlusal load was applied to the palatal surface of the crown with a $60^{\circ}$angle to the long axis of the tooth. The differences in stress transfer characteristics of the models were analyzed. von Mises stresses were chosen for presentation of results and maximum displacement and hydrostatic pressure were also calculated. An increase of the elastic modulus of the post material increased the stress, but shifted the maximum stress location from the dentin surface to the post material. Buccal side of cervical region (junction of core and crown) of the glass fiber post restored tooth was subjected to the highest stress concentration. Maximum von Mises stress in the remaining radicular tooth structure for low elastic modulus resin core (29.21 MPa) was slightly higher than that for high elastic modulus resin core (29.14 MPa) in case of glass fiber post. Maximum displacement of glass fiber post restored tooth was higher than that of zirconia ceramic or stainless steel post restored tooth.