• 제목/요약/키워드: Room fire

검색결과 531건 처리시간 0.028초

미생물에 의한 공기의 SO$_{2}$ 오염방제에 관한 연구 (Studies on the determination of atmospheric sulfur dioxide and elimination of sulfur in kerosene by thiobacilli)

  • 이배함;이병조;이정근;정성구
    • 미생물학회지
    • /
    • 제7권2호
    • /
    • pp.57-62
    • /
    • 1969
  • The experiments attempted to basic studies on the atmospheric dioxide in Korea and on the elimination of sulfur in oil Thiobacilli in order to control of atmospheric sulfur dioxide. The results of experiments are following as : 1) Content of atmospheric sulfur dioxide in industrial zone which used kerosene for fuel was 0.092 ppm(average) and 0.16ppm(maximum). 2) Content of sulfur dioxide at room air which used briquet for stove fire was 0.44ppm (average) adn 0.50 pp,(maximum). 3) Thirteen strains of thiobacilli were isolated from Korean soil and sewage and they were identified with T. thiooxidans (5strains), T. thioparus(3strains), T.ferrooxidans 3 man's observation and the description in Bergey's manual. 4) Two promising strains, one of T. thiooxidans and one of T. ferooxidans. were selected for elimieation of in kerosene.

  • PDF

레저보트${\cdot}$요트의 인테리어재료 특징에 관한 연구 (A Study on Characteristics of Interior design materials in Leisure Boats & Yachts)

  • 변량선
    • 한국실내디자인학회논문집
    • /
    • 제15권1호
    • /
    • pp.158-165
    • /
    • 2006
  • The space of leisure boats & yachts is formed by interior design elements and shapes are formed by combination of those elements. By means of configuration of the design elements, space is made in a ship and patterns in an inside space are made through production. These space can be categorized as (1) cabin(common cabin, staterooms, one-cabin), (2) salon, (3) galleys & dinette, (4) heads(showers, toilets, bidets, sinks), (5) cockpit, (6) wheelhouses, navigation stations, (7) fore peaks, (8) engine room, (9) deck etc. Interior materials are classified into (1) walls(bulkheads & lining wall), (2) floors(sole), (3) ceilings(overheads), (4) doors & windows, (5) furniture, (6) lightings and (7) Hardware & decoration in large, medium and small sizes, which constitute interior design elements of a leisure boat & yacht. The materials used in leisure boats & yachts have properties of lightweight, noise and vibration resistance, fire & flame retardant, stability, strengths, lifespan, appearance and special operation in construction.

전력공급용 주변압기실 Water Mist 소화설비 적용에 관한 연구 (A Sturdy on Water Mist Fire Extinguishment System for the Transformer Room)

  • 노순철;백두현;최영환;지성구
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.39-42
    • /
    • 2004
  • 주변압기실에 Water Mist 소화설비의 적용을 위하여 과거 화재사례 분석, 변압기의 형태, 변압기실의 구조 등을 검토하여 3가지 화재유형을 상정하였고, 발생 가능한 화재규모 및 종류를 검토하여 소화성능 평가를 위한 6가지 화재 시나리오를 제시하고 이를 검증하기 위한 모의실험을 수행하였다. 본 연구를 통하여 주변압기실에 적용 가능한 최적의 Water Mist 소화설비의 시험기준을 정립하였으며, 향후 본 시험기준에 의한 전력공급용 주변압기실 Water Mist 소화설비가 화재에 의한 대형 재난을 예방함과 동시에 안정적인 전력공급에 이바지할 것으로 기대된다.

  • PDF

슬러지 소각시설 악취 및 환기에 관한 연구 (A Study on the Odor and Ventilation in Sludge Incineration Facilities)

  • 서병석;전용한
    • 대한안전경영과학회지
    • /
    • 제22권2호
    • /
    • pp.7-13
    • /
    • 2020
  • Sludge incineration facilities are socially recognized as a hate facility. Therefore, a careful deodorization plan must be established. Therefore, the incineration facility must conduct research on odor ventilation. In this study, a odor diffusion simulation in an incineration facility was conducted and analyzed. In particular, research was carried out on carry-in rooms, pre-treatment rooms, and storage facilities for crops, which are expected to rapidly spread odor. As a result, ammonia 1.62, hydrogen sulfide 0.63, and acetaldehyde 0.73 were found in the transfer room. In addition, pretreatment rooms and stencil storage facilities were found to be lower than regulatory standards.

바닥온돌 매립형 환기덕트시스템의 온도변화에 대한 고찰 (The Changes of Temperature for Embedded Duct Ventilation System in Ondol)

  • 김옥;박진철;김남규;오재근
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.375-380
    • /
    • 2006
  • Embedded Duct Ventilation System in Ondol is embedded supply duct in Ondol. This system allows heat up outside air to inside temperature with out using heat exchanger and electric heating coiling in winter season. In this research, we measured temperature of inside and surface of Ondol, supply duct, and supply air temperature incorporate embedded duct ventilation system in Ondol in model house($110m^2$) & one room($23m^2$)

  • PDF

쪽방촌의 여름철 더위해결을 위한 방안 제시 (A Proposal for the Future of Summer in the Dosshouse)

  • 유남규;김민성;김봉주
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2019년도 추계 학술논문 발표대회
    • /
    • pp.102-103
    • /
    • 2019
  • There are about 3,500 people living in the Seoul Dosshouse, including Namdaemun, Dongdaemun, Donui-dong, Changshin-dong, and Yeongdeungpo. The daytime temperature in the Dosshouse is 43 degrees and the indoor temperature is 35 degrees, which is also higher than the surrouding area. Most of them live in one-person the poor strata, where they have been fighting the heat and the summer. The old building is closely located and a 1.5-pyeong room without windows is a hot environment. Water, air-conditioning is difficult or impossible for people who are economically inferior and cannot solve their own solutions. The solution that can be provided by the country is to heat up once or twice a day by fire hose or shelter. However, there are many patients with discomfort, the distance is far, and the effect is insignificant. Therefore, through this experiment by using discarded banner, I would like to suggest a way to solve the summere heat of the Dosshouse.

  • PDF

Safe Use of Medical Lasers

  • Woo, Seung Hoon;Chung, Phil-Sang;Lee, Sang Joon
    • Medical Lasers
    • /
    • 제10권2호
    • /
    • pp.68-75
    • /
    • 2021
  • Medical lasers have been widely used for various diseases. Despite the notable benefits, lasers could cause several complications such as skin burn, eye injury, airway fire, and so on. These accidents may occur not only with patients, users of the laser, or laser handlers but also to people passing in front of the laser treatment room. Although there is a risk associated with the laser, most of them can be prevented through good training, use of proper protection equipment, and ensuring the safe operation of the laser at all times. Due to the increasing use of lasers and the growing interest in their use, medical institutions should particularly emphasize the safe use of lasers and introduce systems for laser safety.

메틸렌피페라지노메틸-비스-포스폰산 금속염으로 처리된 목재 시험편의 연소특성 (Combustion Characteristics of Wood Specimens Treated with Methylenepiperazinomethyl-Bis-Phosphonic Acid (Mn+)s)

  • 진의;정영진
    • 한국화재소방학회논문지
    • /
    • 제28권3호
    • /
    • pp.55-61
    • /
    • 2014
  • 이 연구에서는 메틸렌피페라지노메틸-비스-포스폰산 금속염($PIPEABPM^{n+}$)과 메틸렌피페라지노메틸-비스-포스폰산(PIPEABP) 으로 처리된 리기다 소나무의 연소성을 시험하였다. 15 wt%의 메틸렌피페라지노메틸-비스-포스폰산 금속염과 메틸렌피페라지노메틸-비스-포스폰산 수용액으로 각각 리기다 소나무에 3회 붓칠하여 실온에서 건조시킨 후, 콘칼로리미터(ISO 5660-1)를 이용하여 그의 연소성을 시험하였다. 그 결과, 메틸렌피페라지노메틸-비스-포스폰산 금속염으로 처리한 시험편은 메틸렌피페라지노메틸-비스-포스폰산을 처리한 시험편에 비해 최대질량감소율($MLR_{peak}$)이 (0.104~0.121) g/s으로 낮았다. 그리고 그의 금속염으로 처리한 시험편($PIPEABPM^{n+}$)은 금속염으로 처리하지 않은 시험편(PIPEABP)보다 낮은 총연기발생률(TSRR), (224.4~484.0) $m^2/m^2$과 낮은 $CO_{mean}$ (0.0537~0.0628) kg/kg 값을 보였다. 특별히 2차 연기발생속도(2nd-SPR)는 메틸렌피페라지노메틸-비스-포스폰산 니켈염($PIPEABPNi^{2+}$)으로 처리한 시험편을 제외하고, 금속염 처리 시험편($PIPEABPM^{n+}$)은 (0.0117~0.0146) g/s으로서 금속염으로 처리하지 않은 시험편(PIPEABP)에 비하여 낮았다. 따라서 메틸렌피페라지노메틸-비스-포스폰산 금속염으로 처리한 시험편은 처리하지 않은 시험편에 비하여 그의 연소 억제성을 부분적으로 향상시켰다.

연소 시험에서 발생하는 일산화탄소와 이산화탄소의 발생 (Production of Carbon Monoxide and Carbon Dioxide Gases in the Combustion Tests)

  • 정영진
    • 한국화재소방학회논문지
    • /
    • 제29권5호
    • /
    • pp.7-13
    • /
    • 2015
  • 본 연구에서는 메틸렌피페라지노메틸-비스-포스폰산 금속염($PIPEABPM^{n+}$)과 메틸렌피페라지노메틸-비스-포스폰산(PIPEABP)으로 처리된 리기다 소나무의 연소독성가스의 생성을 시험하였다. 15 wt%의 메틸렌피페라지노메틸-비스-포스폰산 금속염과 메틸렌피페라지노메틸-비스-포스폰산 수용액으로 각각 리기다 소나무에 3회 붓칠하여 실온에서 건조시킨 후, 콘칼로리미터(ISO 5660-1)를 이용하여 연소독성가스의 생성을 시험하였다. 그 결과, 메틸렌피페라지노메틸-비스-포스폰산 금속염으로 처리한 시험편은 메틸렌피페라지노메틸-비스-포스폰산 철염($PIPEABPFe^{2+}$)으로 처리한 시험편을 제외하고, 메틸렌피페라지노메틸-비스-포스폰산을 처리한 시험편과 비교하여 최대일산화탄소의 생성($CO_{peak}$ production)이 (0.0136~0.0178% at 532~678 s)으로 낮게 나타났다. 그리고 금속염으로 처리한 시험편($PIPEABPM^{n+}$)은 금속염으로 처리하지 않은 시험편(PIPEABP)보다 낮은 최대이산화탄소의 생성($CO_{2\;peak}$ production)이 (0.0537~0.0628% at 532~678 s)임을 보였다. $O_2$의 생성농도는 사람에게 치명적일 수 있는 수준인 15%보다는 훨씬 높으므로 그로 인한 위험성은 배제할 수 있었다. 따라서 메틸렌피페라지노메틸-비스-포스폰산 금속염으로 처리한 시험편은 처리 하지 않은 시험편과 비교하여 연소-유독성을 부분적으로 감소시켰다.

알킬렌디아미노알킬-비스-포스폰산 유도체에 의해 처리된 중밀도섬유판의 연소성 (Combustive Properties of Medium Density Fibreboard (MDF) Specimens Treated with Alkylenediaminoalkyl-Bis-Phosphonic Acid Derivatives)

  • 진의;정영진
    • 한국화재소방학회논문지
    • /
    • 제28권4호
    • /
    • pp.57-63
    • /
    • 2014
  • 이 연구에서는 피페라지노메틸-비스-포스폰산(PIPEABP), 메틸피페라지노메틸-비스-포스폰산(MPIPEABP), N,N-디메틸 렌디아미노메틸-비스-포스폰산(MDEDAP), 비스-디알킬아미노알킬 포스폰산(DMDAP)으로 처리된 중밀도섬유판(MDF)의 연소성을 시험하였다. 15 wt%의 알킬렌디아미노알킬-비스-포스폰산 수용액으로 MDF에 3회 붓칠하여 실온에서 건조시킨 후, 콘칼로리미터(ISO 5660-1)를 이용하여 그의 연소성을 시험하였다. 그 결과, 알킬렌디아미노알킬-비스-포스폰산 및 비스-디메틸아미노메틸 포스피닉산(DMDAP)로 처리한 시험편은 연소속도 감소에 의하여 무처리한 시험편에 비해 최대질량감소율 도달시간($TMLR_{peak}$) = (340475) s을 지연시켰다. 게다가 $CO_{mean}$은 (0.0883~0.0963) kg/kg으로서 무처리한 시험편(0.0612 kg/kg)보다 높게 측정되었다. 특별히 화학 첨가제 수용액으로 처리한 시험편의 비소화면적($SEA_{mean}=5m^2/kg{\sim}21.5m^2/kg$)은 무처리한 시험편의 비소화면적($-426.8m^2/kg$) 보다 높았다. 따라서 알킬렌디아미노알킬-비스-포스폰산 및 비스-디알킬아미노알킬 포스폰산으로 처리된 MDF의 시험편은 무처리한 MDF 시험편의 난연성을 향상시킨 것으로 판단된다. 그러나 연기발생량 감소에는 부정적인 영향을 주었다.