• Title/Summary/Keyword: Room Unit

Search Result 702, Processing Time 0.029 seconds

Effect of Pre-treatment and Packaging Method on Freshness Prolongation of Spring Kimchi Cabbage during Low Temperature Storage (봄배추의 전처리 및 포장방법이 저온저장 중 선도유지에 미치는 효과)

  • Se-Jin Park;Ji-Young Kim;Andri Jaya Laksana;Byeong-Sam Kim
    • KOREAN JOURNAL OF PACKAGING SCIENCE & TECHNOLOGY
    • /
    • v.29 no.2
    • /
    • pp.119-128
    • /
    • 2023
  • This study was examined for investigating the quality changes of spring kimchi cabbage under various treatments (pre-drying/pre-cooling, packaging types, and stacking and loading in container and pallete in the storage room) during cold storage. The results showed that control (upward stacking without pre-drying/pre-cooling and HDPE or PVC film cover) was increased significantly in weight loss and trimming loss, compared to other treatments such as DPDH (downard stacking + pre-drying + HDPE), DPDP (downard stacking + pre-drying + PVC), DPCH (downnard stacking + pre-cooling + HDPE), and UPCH (upward stacking + pre-cooling +HDPE) during storage for three months. In Sensory evaluation, judging from marketable properties, the desirable appearance of spring kimchi cabbage with the modified pallet-unit MA packed, PE, and PVC film wrapping could be maintained until 9 weeks after pre-drying/pre-cooling. Meanwhile, the control without any treatments after 6 weeks, the sensory score was declined, significantly. In general, the low temperature (10℃ and 2℃) of pre-treatment with combination of plastic film packaging in spring kimchi cabbage storage could inhibit the physiological activity and reduce the direct exposure of environmental cold air in the storage. Therefore, these two variables were the key points for extending the shelf-life of spring kimchi cabbage.

Study on the Plan to Reduce the EVENT of the Gas Regulator (정압기 EVENT 감소방안 연구)

  • Kang-ok Yun;Tae-jun Eom;Ki-beom Kim;Yong-woo Lee;Hyoung-Min Lee;Byeong-Geun Gong
    • Journal of the Korean Institute of Gas
    • /
    • v.27 no.1
    • /
    • pp.57-62
    • /
    • 2023
  • The Gas Regulator EVENT is a signal sent by the Remote Terminal Unit(RTU) installed in each local gas regulator (hereinafter referred to as "regulator"), and is an abnormal alarm that can be intuitively checked in our client server. This is an important data that enables immediate dispatch order and initial action in the situation room when a regolator abnormality occurs, and can analyze the cause of the regulator abnormality. Looking at the trend of EVENT data for regulator over the past three years, there is a clear trend of increasing unchecked EVENT data. The increase in non-checking event (actual abnormality or noise event) may mean that firstly, mechanical or pressure abnormality occurs in the actual regulator, and secondly, there is no abnormality in the actual regulator, but communication error occurred in the RTU, reset. EVENT Data may be formed as if an abnormality occurred in the static voltage due to an error, sensor error, power failure (instantaneous power failure), etc. Among them, this study analyzed the recently generated unchecked EVENT data to identify critical noise events among RTU errors, which are noise events, and reviewed ways to increase the reliability of Regulator EVENTs by reducing them.

Evaluation of Ventilation Performances for Various Combinations of Inlets and Outlets in a Residential Unit through CO2 Tracer-Gas Concentration Decay Method (CO2 추적가스 농도감소법을 이용한 공동주택의 급·배기구 조합에 따른 환기 성능 분석)

  • Sang Yoon Lee;Soo Man Lee;Jong Yeob Kim;Gil Tae Kim;Byung Chang Kwag
    • Land and Housing Review
    • /
    • v.14 no.4
    • /
    • pp.111-120
    • /
    • 2023
  • Indoor air quality has become increasingly important with the increase in time spent in residential environments, impact of external fine dust, yellow dust, and the post-COVID 19 pandemic. Residential mechanical ventilation plays a key role in addressing indoor air quality. The legal standard for residential air changes per hour in Korea is 0.5 ACH. However, there are no standards for the location of supply and return vents. This study atempts to analyze the impact of ventilation performance based on the location of supply and return vents. An experiment was conducted using the CO2 tracer gas concentration decay method in a mock-up house set inside a large chamber to minimize external influences. The experimental results indicated that the commonly used combination of 2 supply and 2 return vents in living room spaces had a lower mean age of air than the combination of 1 supply and 2 return vents. Using multiple supply and return vents had lower mean age of air than using just 1 supply and 1 return vent.

The Consideration about Heavy Metal Contamination of Room and Worker in a Workshop (공작실에서 실내 및 작업종사자의 중금속 오염도에 관한 고찰)

  • Kim Jeong-Ho;Kim Gha-Jung;Kim Sung-Ki;Bea Suk-Hwan
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.17 no.2
    • /
    • pp.87-94
    • /
    • 2005
  • Purpose : Heavy metal use when producing the block from the workshop. At this time, production of heavy metal dust and fume gives risk in human. This like heavy metal to improve seriousness through measurement and analysis. And by the quest in solution is purpose of this thesis. Materials and Methods : Organization is Inductively Coupled Plasma Atomic Emission Spectrometer, and the object is Deajeon city 4 workshops in university hospital radiation oncology (Bismuth, Lead, Tin and cadmium). Method is the ppb the pumping it does at unit, comparison analysis. And the Calculation heavy metal standard level in air through heavy metal standard level in body and blood, so Heavy metal temporary standard set. Results : Subterranean existence room air quality the administration laws appointed Lead and Cadmium's exposure recommend that it is $3{\mu}g/m^3\;and\;2{\mu}g/m^3$. And Bismuth and Tin decides $7{\mu}g/m^3\;and\;6{\mu}g/m^3$ through standard level in air heavy metal and standard level in body and blood. Heavy metal measurement level of workshops in 4 university hospital Daejeon city compares with work existence and nonexistence. On work nonexistence almost measurement level is below the recommend level. But work existence case express high level. Also consequently in composition ratio of the block is continuous with the detection ratio. Conclusion : Worker's heavy metal contamination imbrued serious for solution founds basic part. In hospital may operation on local air exhauster and periodical efficiency check, protector offer, et al. And worker have a correct understanding part of heavy metal contamination, and have continuous interest, health control. Finally, learned society sphere administer to establishment standard level and periodical measurement. And it founds basic solution plan of periodical special health checkup.

  • PDF

Study on the Storage of Chestnut (밤 저장(貯藏)에 관(關)한 연구(硏究))

  • Yim, Ho;Kim, Choung-Ok;Shin, Dang-Wha;Suh, Kee- Bong
    • Korean Journal of Food Science and Technology
    • /
    • v.12 no.3
    • /
    • pp.170-175
    • /
    • 1980
  • A mass production of chestnut necessiates the development of economic long-term storage method. The main objective of this study was to confirm the technical aspect of the chestnut storage method which was developed by two year project and to review the method of commercial application. The chestnut used for the experiments were separated in brine $(5.5{\sim}6.0^{\circ}\:B{\acute{a}}ume)$ into matured and unmatured lots and fumigated with $CS_2$ at a 5 $lb/27\;m^3$ level for $25{\sim}30\;hrs.$ The chestnuts were packed in wooden boxes with sawdust (50% moisture) in the ratio of 1 : 1 by volume. The boxes were stored in the cold room $(1{\pm}1^{\circ}C,\;85{\sim}95%\;RH)$ and the cellar ($0{\sim}10^{\circ}C$, controlled only by circulating night cool air). The results obtained were as follows: 1. Fully matured chestnut could be successfully preserved $8{\sim}9\;months$ at a l0% decay level in the cold room and $4{\sim}5\;months$ months in cellar. 2. Immatured chestnuts wire inferior to the matured in storage stability. At the maximum storage period, its storage life was two months shorter. 3. The heat transfer equation of piled chestnuts with sawdust can be suggested as $T_{\infty}-T_0=(T_{\infty}-T_0){\cdot}10^{-t/320}$ and j and $f_h$ values were 1 and 320 min, respectively. 4. The chestnuts in the package of storage unit had longer shelf life than naked chestnut during the retail distribution at ambient temperature.

  • PDF

Characterization and Conversion Electron Mössbauer Spectroscopy of HoMn1-x-FexO3 Thin Films by Pulsed Laser Deposition (PLD를 이용한 HoMn1-x-FexO3 박막 제조 및 후방 산란형 뫼스바우어 분광 연구)

  • Choi, Dong-Hyeok;Shim, In-Bo;Kim, Chul-Sung
    • Journal of the Korean Magnetics Society
    • /
    • v.17 no.1
    • /
    • pp.18-21
    • /
    • 2007
  • The hexagonal $HoMn_{1-x}-Fe_xO_3$(x=0.00, 0.05) thin films were prepared using pulsed laser deposition(PLD) method on $Pt/Ti/SiO_2/Si$ substrate. The microstructure and magnetic properties have been studied by x-ray diffraction(XRD), atomic force microscopy (AFH), scanning electron microscope(SEM:), x-ray photoelectron spectroscopy(XPS), and conversion electron $M\"{o}ssbauer$ spectroscopy(CEMS). From the analysis of the x-ray diffraction patterns, the crystal structure for all films was found to be a hexagonal($P6_3cm$), which was preferentially grown along(110) direction. The lattice constant $c_0$ of the film with x=0.05 was close to that of single crystal, whereas lattice constant $a_0$ with respect to single crystal shows a slight decrease. This difference of lattice parameters between film and single crystal was caused by the lattice mismatch between the film and $Pt/Ti/SiO_2/Si$ substrate. Conversion electron $M\"{o}ssbauer$ spectrum of $HoMn_{0.95}Fe_{0.05}O_3$ thin film shows an asymmetry doublet absorption ratio at room temperature, which is due to the oriented direction of crystallographic domains. This is corresponding with analysis of x-ray diffraction. The quadrupole splitting(${\Delta}E_Q$) at room temperature is found to be $1.62{\pm}0.01mm/s$. This large ${\Delta}E_Q$ was caused by asymmetry environment surrounding Fe ion.

Particulate Matter and CO2 Improvement Effects by Vegetation-based Bio-filters and the Indoor Comfort Index Analysis (식생기반 바이오필터의 미세먼지, 이산화탄소 개선효과와 실내쾌적지수 분석)

  • Kim, Tae-Han;Choi, Boo-Hun;Choi, Na-Hyun;Jang, Eun-Suk
    • Korean Journal of Environmental Agriculture
    • /
    • v.37 no.4
    • /
    • pp.268-276
    • /
    • 2018
  • BACKGROUND: In the month of January 2018, fine dust alerts and warnings were issued 36 times for $PM_{10}$ and 81 times for PM2.5. Air quality is becoming a serious issue nation-wide. Although interest in air-purifying plants is growing due to the controversy over the risk of chemical substances of regular air-purifying solutions, industrial spread of the plants has been limited due to their efficiency in air-conditioning perspective. METHODS AND RESULTS: This study aims to propose a vegetation-based bio-filter system that can assure total indoor air volume for the efficient application of air-purifying plants. In order to evaluate the quantitative performance of the system, time-series analysis was conducted on air-conditioning performance, indoor air quality, and comfort index improvement effects in a lecture room-style laboratory with 16 persons present in the room. The system provided 4.24 ACH ventilation rate and reduced indoor temperature by $1.6^{\circ}C$ and black bulb temperature by $1.0^{\circ}C$. Relative humidity increased by 24.4% and deteriorated comfort index. However, this seemed to be offset by turbulent flow created from the operation of air blowers. While $PM_{10}$ was reduced by 39.5% to $22.11{\mu}g/m^3$, $CO_2$ increased up to 1,329ppm. It is interpreted that released $CO_2$ could not be processed because light compensation point was not reached. As for the indoor comfort index, PMV was reduced by 83.6 % and PPD was reduced by 47.0% on average, indicating that indoor space in a comfort range could be created by operating vegetation-based bio-filters. CONCLUSION: The study confirmed that the vegetation-based bio-filter system is effective in lowering indoor temperature and $PM_{10}$ and has positive effects on creating comfortable indoor space in terms of PMV and PPD.

Effects of Active MA Mini-packaging on Shelf-life Maintenance during Marketing of Perilla Leaves (깻잎의 active MA 소포장이 유통기간 중 신선도 유지에 미치는 영향)

  • Jeong, Cheon-Soon;Um, Gi-Jeung;Park, Jong-Nam
    • Horticultural Science & Technology
    • /
    • v.28 no.6
    • /
    • pp.980-984
    • /
    • 2010
  • Research regarding respiration rate, off-flavor related material and freshness maintenance effect of active MA mini-packaging on perilla leaves has been carried in this study. Respiration rate was highly maintained at high oxygen treatments ($CO_2:O_2:N_2$=0:30:70 and 0:50:50), higher than non-treatment and low oxygen treatments (6:2:92, 0:10:90) during the storage period, and ethylene production was relatively higher. However, off-flavor related materials, acetaldehyde and ethanol production was noticeably low. Weight losses of non-treatment and low-oxygen treatment were about 1.8 and 1.4%, respectively. At the fifth day of storage there was no weight loss. Ascorbic acid content was 13.3 mg/100 g F.W. at the first day of storage. At the third day of storage non-treatment showed the lowest value of ascorbic acid, 8.8 mg/100 g F.W. Ascorbic acid content of active MA treatment gradually decreased without a striking difference as the storage day extended. Chlorophyll content was the lowest at the fifth day of storage with non-treatment, 47.5 (SPAD-502 unit) while the active MA treatment maintained high level of chlorophyll content, 53.0. Sensory evaluation (vision) showed that marketability gradually decreased but was maintained in high oxygen treatments (0:30:70 and 0:50:50), even at the fifth day of storage. Occurrence of off-flavor in non-treatment at the fifth day of storage was extremely low, 2.6; whereas high in high oxygen treatment, 3.4. Active MA packaging maintained freshness two more days at room temperature (about $27^{\circ}C$).

A Study on the Experience of Physical Therapy Accident in The Physiotherapist (물리치료사에 있어서 물리치료 사고의 경험에 관한 연구)

  • Kim, Jong-Dae
    • Journal of Korean Physical Therapy Science
    • /
    • v.9 no.1
    • /
    • pp.69-80
    • /
    • 2002
  • The objective of research provides the physical therapy of good quality to the patients to search for the problem pant against a physical therapy accident and it simultaneously respects physical therapy company law, the possibility of preparing a system defensive ability in order to be. The data were collected from 2000 October 1 to December 30th, and analyzed by a frequency and a percentage, oneway ANOVA, Scheffe method, $x^2$ official approvals. Conclusion (1) the accident where the patient falls from inside the treatment 'room is many and occasionally' 29.3% (63 people) with was many most. (2) Because of a mistake by a part-time therapist in holiday or a colleague therapist to do, the fracture or bum accident happens 12.5% (27 people), by a assist nurse due to more showed 12.1% (26 people) experience degree in the patient. (3) From physical therapy process breakdown of the medical treatment machinery and tools or it is in malfunction to do and the experience which has a failure to physical therapy is one enemy 68.1% (147 people) was in item. Also it treats and the patient or in the protector it sends an explanation in advance not to be, the experience which it enforces 50% (108 people), of service hour treatment equipment the medical treatment directives broad way of the doctor is accurate in insufficiency and does not enforce the experience is 45.4% (98 people), the patient whom I am treating Hot Pack (electricity has pack inclusion) with to do, the art dealer (over at 1 buffoonery) the experience which it puts on 27.1% (58 people), The patient whom I am treating is the electrotherapy flag (electricity has pack exclusion) with to do, the art dealer (1 degree art dealer over) the experience which it puts on 16.3% (35 people), the experience boat song the patient against a fracture from physical therapy process 9 person (4.2%) was visible an experience degree. (4) With hospital infection to do, from the patient the experience and the therapist which receive a problem proposal were caused by with hospital infection and the answer back regarding the experience which tries to receive a treatment appeared 6% (13 people), 42% (9 people) with each. (5) It listened to the treatment hour patient or the appeal of the protector and especially it does not appear to be being important it was not and and the management which is special it did not take, also the experience where the condition of the patient is deteriorated after that was 10.3% (22 people). (6) The condition or state of the patient does not agree with the medical treatment instruction of the doctor not to be, amendment one experience was 67.5% (145 people). (7) The experience degree of the physical therapy accident which relates with physical therapy recording and a secret maintenance 59.7% (129 people) 'is many and occasionally it is,' it showed an answer back and e it showed a most high accident experience degree. (8) The business overweight of physical therapy company 43.3% (93 people) with was high most from recognition degree of the physical therapy company against a physical therapy accident. (9) Against the question which asks the responsibility subject matter of physical therapy accident the whole answer back volition 42.8% did it is a joint responsibility where the multi person relates. (10) The accident occurs most the hour unit which plentifully in the afternoon 64.3% (133 people) with appeared from the recognition degree against the frequency hour unit of physical therapy accident. (11) Physical therapy it bought and after the various medical treatment accident which relates against the attitude of the, patient side against the physical therapy company it understood and trillion it was many most with 33.3% to be finished. (12) After physical therapy accident the management against the physical therapy company of the hospital authorities concerned above all do not experience 70.6% (149 people), from event right and wrong submission 22.7% (48 people), warning management 2.8% (6 people), the event report requirement and money compensation were each 0.5% (1 person). (13) As the prevention book of physical therapy accident most it is important, the fact which it thinks that, the persons supplement of physical therapy company 58.8% (127 people) with was high most. (14) It related with a physical therapy accident and the medical law 43.5%, civil law 23.9%, was visible the answer back ratio of the criminal law 13.7% from the degree which probably is a relation law.

  • PDF

MODULATION OF INTRACELLULAR pH BY $Na^+/H^+$ EXCHANGER AND $HCO_3^-$ TRANSPORTER IN SALIVARY ACINAR CELLS ($Na^+/H^+$ exchanger와 $HCO_3^-$ transporter에 의한 흰쥐 타액선 선세포내 pH 조절)

  • Park, Dong-Bum;Seo, Jeong-Taeg;Sohn, Heung-Kyu;Lee, Jong-Gap
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.25 no.2
    • /
    • pp.352-367
    • /
    • 1998
  • Intracellular pH (pHi) plays an important role in the regulation of cellular processes by influencing the acitivity of various enzymes in cells. Therefore, almost every type of mammalian cell possesses an ability to regulate its pHi. One of the most prominent mechanisms in the regulation of pHi is $Na^+/H^+$ exchanger. This exchanger has been known to be activated when cells are stimulated by the binding of agonist to the muscarinic receptors. Therefore, the aims of this study were to compare the rates of $H^+$ extrusion through $Na^+/H^+$ exchanger before and during muscarinic stimulation and to investigate the possible existence of $HCO_3^-$ transporter which is responsible for the continuous supply of $HCO_3^-$ ion to saliva. Acinar cells were isolated from the rat mandibular salivary glands and loaded with pH-sensitive fluoroprobe, 2', 7'-bis(2-carboxyethyl)-5(6)-carboxyfluorescein(BCECF), for 30min at room temperature. Cells were attached onto the coverglass in the perfusion chamber and the changes in pHi were measured on the iverted microscope using spectrofluorometer. 1. By switching the perfusate from $HCO_3^-$-free to $HCO_3^-$-buffered solution, pHi decreased by $0.39{\pm}0.02$ pH units followed by a slow increase at an initial rate of $0.04{\pm}0.007$ pH units/min. The rate of pHi increase was reduced to $0.01{\pm}0.002$ pH units/min by the simultaneous addition of 1 mM amiloride and $100{\mu}M$ DIDS. 2. An addition and removal of $NH_4^+$ caused a decrease in pHi which was followed by an increase in pHi. The increase of pHi was almost completely blocked by 1mM amiloride in $HCO_3^-$-free perfusate which implied that the pHi increase was entired dependent on the activation of $Na^+/H^+$ exchanger in $HCO_3^-$-free condition. 3. An addition of $10{\mu}M$ carbachol increased the initial rate of pHi recovery from $0.16{\pm}0.01$ pH units/min to $0.28{\pm}0.03pH$ units/min. 4. The initial rate of pHi decrease induced by 1mM amiloride was also increased by the exposure of the acinar cells to $10{\mu}M$ carbachol ($0.06{\pm}0.008pH$ unit/min) compared with that obtained before carbachol stimulation ($0.03{\pm}0.004pH$ unit/min). 5. The intracellular buffering capacity ${\beta}1$ was $14.31{\pm}1.82$ at pHi 7.2-7.4 and ${\beta}1$ increased as pHi decreased. 6. The rate of $H^+$ extrusion through $Na^+/H^+$ exchanger was greatly enhanced by the stimulation of the cells with $10{\mu}M$ carbachol and there was an alkaline shift in the activity of the exchanger. 7. An intrusion mechanism of $HCO_3^-$ was identified in rat mandibular salivary acinar cells. Taken all together, I observed 3-fold increase in $Na^+/H^+$ exchanger by the stimulation of the acinar cells with $10{\mu}M$ carbachol at pH 7.25. In addition, I have found an additional mechanism for the regulation of pHi which transported $HCO_3^-$ into the cells.

  • PDF