• 제목/요약/키워드: Roof window control

검색결과 19건 처리시간 0.026초

자연환기량과 포그분무량 조절에 의한 온실 온습도의 동시제어 기법 연구 (A Study on the Control of the Temperature and Relative Humidity in Greenhouse by Adjusting the Amount of Natural Ventilation and Fog Spray Quantity)

  • 김영복;성현수;황승재;김현태;유찬석
    • 한국태양에너지학회 논문집
    • /
    • 제36권5호
    • /
    • pp.31-50
    • /
    • 2016
  • To develope a greenhouse fog cooling system to control the temperature and relative humidity simultaneously to the target value, a theoretical analysis and experiments were done. The control process includes the measuring of environmental variables, setting and coding of the water and heat balance equations to maintain the target temperature and relative humidity in greenhouse, calculating of the open level of the greenhouse roof window that governs the natural ventilation and spray water quantity, and operating of the motor to open/close the roof window and pump to spray for water. The study results were shown to be very good because the average air temperature in the greenhouse was kept to be about $28.2^{\circ}C$ with the standard deviation of about $0.37^{\circ}C$ compared to the target temperature of $28^{\circ}C$ and the average relative humidity was about 75.2% compared to the target relative humidity was 75% during the experiments. The average outside relative humidity was about 41.0% and the average outside temperature was $27.2^{\circ}C$ with the standard deviation of about $0.54^{\circ}C$. The average solar intensity in the greenhouse was 712.9 W. The wind velocity of outside greenhouse was 0.558 m/s with the standard deviation of 0.46 m/s.

동해연안 주택외관의 인지특성에 관한 연구 (An Analysis on the characteristic of recognition about Individual Housing according to the landscape in Donghae Seaside)

  • 조원석;김흥기;김용기;주재우;김정현
    • 한국농촌건축학회논문집
    • /
    • 제7권3호
    • /
    • pp.27-35
    • /
    • 2005
  • This study is about finding out characteristic of recognition individual housing in seaside of Donghae. To accomplish this purpose, we survey the 150 houses related to the landscape. Thus the major analysis is to take basic data, such as image(modern, western, traditional, etc) about exterior form of housing corresponding to the landscape. The result summarized as follows First, the elements for the characteristic of recognition were exterior material finish, exterior color, roof type, roof material finish, window size, roof slope, area of wall vs roof. Second, the image of traditional housing was very insufficient to plan landscape of housing with design elements. This research suggests that landscape housing of future is to be environmental landscape design and the proper design is to be various considering not only user's preference but also control of landscape.

  • PDF

단동 플라스틱 온실의 천창 환기효과와 설치기준 분석 (Analysis on the installation criteria and ventilation effect for round roof windows in single-span plastic greenhouses)

  • 남상운;김영식;고기혁;성인모
    • 농업과학연구
    • /
    • 제39권2호
    • /
    • pp.271-277
    • /
    • 2012
  • Dimensions, operation conditions and improvement items for round roof windows were investigated in arch shape single-span plastic greenhouse with roof vents, and natural ventilation performance was analyzed based on the ventilation theory. Diameter of round roof windows was mostly 60 cm, and chimney height projected on roof was average 30 cm. Installation space was mostly 5 to 6 m but farmhouse of 10 m and over was 16.7% also. A round roof window which has 60 cm diameter was installed to 6 m space generally and 80 cm diameter was installed to 10 m space, but correct standards did not exist. There were a lot of opinions that ventilation effect of round roof windows is fairly good and user satisfaction is generally excellent. It is problem that there is few effects in summer and that vinyl around each vent tears well and rainwater leaks, and improvement hope item required development of automatic control system. In the wind speed of 0.3 m/s, it was estimated that natural ventilation rates were 0.69, 0.55, 0.50 and 0.48 volumes per minute in case of 2, 4, 6 and 8 m installation space for round roof windows, respectively. It was analyzed that the ratio of ventilation due to buoyancy out of total ventilation were 65.2, 41.9, 29.9 and 22.8% in case of 2, 4, 6 and 8m installation space, respectively. By the round roof windows installed at space of 6 m, ventilation rate was estimated to 0.5 volumes per minute, and we can expect the increase in ventilation rate of 30%. In order to meet the recommended ventilation rate for summer season, we have to install the round roof windows at space of 1 to 2 m. However, it is difficult to apply those installation space because of falling productivity due to lower light transmittance as well as rising costs. It is estimated that the installation space of 6m is appropriate for spring or fall season. Therefore it is necessary to encourage installing the roof windows in single-span plastic greenhouses.

경북북부지역 전통 양반가옥의 채광조절 기능에 관한 연구 -처마, 창호(窓戶), 창호지(窓戶紙)를 중심으로- (Daylighting Controls of Korean Traditional Houses built in Chosun Dynasty especially on examples located in northern Gyeongbuk province)

  • 김곤;구재오
    • KIEAE Journal
    • /
    • 제4권3호
    • /
    • pp.79-85
    • /
    • 2004
  • There is something valuable in Korean traditional architecture that does not change even after more than a number of years. Each design element of traditional houses has its own role to embody natural, healthy, and environment-friendly architectural planning. With traditional already-built examples located in the northern area of Gyeongbuk province, this study attempts to untangle some of the daylighting control issues in opening design. By looking at more than just photometric materials, at some threshold level, the whole of daylighting control characteristics of their openings is being surveyed from the viewpoint of geometric relationship between their roof structures and windows. As a glazing material, in addition, Korean traditional window covering paper, Changhoji, is evaluated for its transmittal performance under artificial and real skies as well.

아치형 단동온실의 지붕환기구조 및 천창효과 (Roof Ventilation Structures and Ridge Vent Effect for Single Span Greenhouses of Arch Shape)

  • 남상운
    • 농업과학연구
    • /
    • 제28권2호
    • /
    • pp.99-107
    • /
    • 2001
  • 온실재배에 있어서 가장 경제적인 환경조절방법은 자연환기에 의한 것이므로 온실의 자연환기 성능을 극대화하는 것은 매우 중요하다. 온실의 자연환기 성능을 극대화하기 위해서는 지붕환기창의 설치가 중요한데, 아치형 단동 온실의 경우에는 천창을 설치하기 어려운 구조로 되어 있어서 대부분의 농가가 측창만 설치하여 운영하고 있다. 본 연구에서는 아치형 단동 온실의 지붕에 환기창 설치를 장려하기 위한 일환으로 사례조사와 효과분석을 실시하였다. 아치형 단동 온실의 지붕환기구조 실태조사 결과 폭 5~8m의 소형 온실에서는 플라스틱으로 제작된 원형 및 굴뚝형 환기창을, 폭 12~18m의 대형온실에서는 철재 파이프를 덧붙인 양권취식을 많이 사용하고 있었다. 지붕환기창 설치 온실과 관행의 권취식 측창만 설치된 온실에 대한 대조 실험 결과 비록 적은 면적의 지붕환기창을 설치하였지만 온도하강 $1^{\circ}C$ 이상의 천창 환기 효과가 있었으며, 지붕환기를 실시함으로써 온도분포를 보다 균일하게 할 수 있는 것으로 나타났다. 지붕환기창을 설치함으로서 얻을 수 있는 온도상승 억제효과는 일사량과 풍속조건에 따라 뚜렷한 차이를 보이며, 풍속이 낮은 경우에 효과가 커지는 것을 확인할 수 있었다. 환기창의 개폐순서에 따른 전체적인 온도 하강의 차이는 없으나, 환기로 온도를 제어하는 경우에는 실내온도가 설정온도보다 높을 때는 천창을 열은 후 측창을 열고, 반대의 경우에는 측창을 닫은 후 천창을 닫는 것이 바람직한 것으로 판단되었다.

  • PDF

차량 윈도우 리프트 음질 향상을 위한 음질 지수 제작 및 개선에의 응용 (The Development and Application of Sound Quality Index for the Improving Sound Quality to Road Vehicle Power Window System)

  • 김성현;박동철;조현호;성원찬;강연준
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2013년도 추계학술대회 논문집
    • /
    • pp.525-530
    • /
    • 2013
  • With the increasing the importance of emotional quality of vehicle, the sound quality of systems with electric motor components has become increasingly important. Electric motors are used for windows, seats, sun roof, mirrors, steering columns, windshield wiper, climate control blowers, etc. In this paper, a study was conducted to identify sound quality factors that contribute to customer's satisfaction and preference of the window lift system. Jury test for subjective evaluation was carried out and sound quality index was developed. Averaged sound pressure level and sharpness were significant factors when glass moves down. Also, maximum loudness at stop section and averaged loudness were significant factor when glass moves up. Noise source identification was carried out for the reduced the loudness and sharpness during glass transferred section and impulsive noise at stop section, Using the source identification result, several improvement points were applied. And finally, the degree of sound quality improvement was judged using sound quality index.

  • PDF

단순 퍼지 제어기법을 이용한 온실의 천창환기에 의한 냉방제어 (Cooling Control of Greenhouse Using Roof Window Ventilation by Simple Fuzzy Algorithm)

  • 민영봉;윤용철;허무룡;강동현;김현태
    • 농업생명과학연구
    • /
    • 제44권4호
    • /
    • pp.69-77
    • /
    • 2010
  • 온실의 환기제어시 외기온도와 풍속변화에 보다 유연하게 대처하면서 온실내 온도제어성능을 향상시키기 위해서 퍼지제어가 많이 이용되고 있지만, 제어로직이 복잡하여 대용량 메모리를 갖는 컨트롤러가 필요하다. 본 연구에서는 소용량의 마이크로 컨트롤러에서 프로그램이 가능한 단순퍼지제어 알고리즘을 개발하여 시험하였다. 개발한 단순퍼지 제어 알고리즘의 성능을 비교하기 위하여 기존의 스텝제어 알고리즘을 도입한 제어프로그램으로 온실의 천창환기에 의한 온도제어를 실시하여 두 알고리즘의 성능을 직접 비교하고, 또 PID 및 표준 퍼지제어 성능과는 기존의 연구 결과와 비교하여 상대적 성능을 평가하므로써 온실의 환기냉방제어의 유리한 제어기법을 확립할 수 있는 기초자료를 얻고자 수행하였다. 단순 퍼지제어에 의한 실내온도 최대 제어오차는 $1.2^{\circ}C$, 1시간동안의 평균환기창 적산열림량과 조작회수는 각각 84%, 13회로 나타났으며, 문헌조사에 의한 퍼지제어에서 각각 $1.3^{\circ}C$, 75% 및 12회에 비해 동등한 제어성능을 보였다. 본 연구에서 개발한 단순퍼지제어는 제어로직이 PID제어보다 단순함에도 불구하고 스텝제어와 PID제어보다 성능이 우수하고, 퍼지제어와 동등한 제어성능을 갖는 것으로 나타났다.

패널굴절방식 환기창 온실의 환기효과 (Ventilation Effect of the Greenhouse with Folding Panel Type Windows)

  • 김진영;이시영;김현환;전희;윤익학
    • 생물환경조절학회지
    • /
    • 제11권1호
    • /
    • pp.5-11
    • /
    • 2002
  • 본 연구는 여름 같은 고온기나 외부온도가 높지 않아도 시설내 온도가 많이 상승하는 봄 .가을 같은 시기에 온실내 고온 공기를 외부로 신속하게 유출시켜 강제환기를 사용하지 않고도 온실내부의 환경을 조절 할 수 있는 새로운 자연 환기창을 개발하는데 목적을 두고 수행하였다 패널굴절방식 측창은 지면에 가까운 쪽의 패널 하부에 절점을 두고 패널 상부가 측고 부위로부터 가이드 레일을 따라 하향하도록 구성하여 창이 개방되게 하였고, 천창은 측고 부위에 절점을 두고 용마루 쪽의 패널 상부가 가이드 레일을 따라 경사진 지붕면을 따라 하향하도록 구성하여 고온 공기층이 정체되어 있는 온실 상부인 측고 부위와 용마루 부위가 개방되도록 하였다. 굴절 패널의 상부 개방거리는 X=L(1-cos$\theta$)로 나타낼 수 있고 측면 개방 거리는 Y=L/2$\times$sin$\theta$로 나타낼 수 있다. 천창 개방시간은 4분 20초 소요되었으며 개방 시작한 2분 후부터 온도가 하강하기 시작하였고, 완전 개방 2분 후부터는 외기온과의 온도차 3~4$^{\circ}C$정도를 유지하면서 평형상태를 유지하였다. 패널굴절방식 환기창 온실의 환기성능은 체적환기량이 22.3-94.3m$^3$.m$^{-2}$ .h$^{-1}$이었으며, 환기 횟수는 15.2~39.3회.h$^{-1}$로 나타나 일반적인 연속형 천창의 10~15회.h$^{-1}$ 정도에 비해 환기효과가 높은 것으로 나타났다. 그리고 벤로형 온실과의 천창개폐시 온도하강을 비교하였을 때 환기효과가 2배 이상 높은 것으로 판단되었다.$_{r}$", $\mu$$_{r}$′) and the dielectric loss ($\varepsilon$$_{r}$"/$\varepsilon$$_{r}$′) were increased. It was caused that the absorption characteristics of the absorber were improved. The conduction loss and magnetic loss were expected to be occurred together because two matching frequencies were shown with carbon addition. It was confirmed that the matching frequency of the microwave absorber could be controlled by controlling heat-treatment temperatures and carbon additions.ons.tions.加的)으로 되거나 과가황(過加黃)이 될 우려가 있는 제조공정(製造工程)에서는 흔히들 이 방법(方法)을 무시(無視)하고 있다. 여기서 강조(强調)해 두어야 할 것은 항상 제품(製品)의 외부(外部)를 완전(完全)히 가황(加黃)시킬 필요(必要)는 없다는 것이다. 다공성(多孔性)이나 기포생성(氣泡生成)을 조장(助長)하는 불량가황상태(不良加黃狀態)와 표면(表面)에서의 과가황상태간(過加黃狀態間)의 균형(均衡)을 취(取)해 줘야 하는데 물론(勿論) 이때는 가황시간(加黃時間)을 단축(短縮)시켜야 한다는 경제적(經濟的)인 측면(側面)도 아울러 고려(考慮)해야 한다

포그냉방 온실에서 측창개폐수준이 온습도 제어에 미치는 영향 (Effects of the Open Level of the Side Window on the Control of the Temperature and Relative Humidity in the Fog Cooling Greenhouse)

  • 김영복;성현수;윤남규;이시영;황승재;김현태;이장평
    • 농업생명과학연구
    • /
    • 제45권6호
    • /
    • pp.265-278
    • /
    • 2011
  • 하절기 온실 내 온도와 상대습도를 동시에 제어할 목적으로 압축공기를 이용한 이류체 분무 포그 냉방을 도입한 유리온실에서 측창의 개폐수준이 온실내의 온도와 상대습도 제어에 어떠한 영향을 주는지 분석하였다. 제어과정은 온실 환경변수들을 측정하고, 이를 반영하여 온실 내 수분평형방정식과 열평형방정식을 정립한 다음, 이 방정식들을 프로그램으로 코딩하여 각 사이클의 천창 개폐량과 포그 분무량을 결정하고 제어하였다. 온실의 온습도 제어목표는 온도와 습도를 각각 28, 75%로 설정하였고, 실험은 측창이 전혀 열리지 않은 0%, 50% 열린 경우, 100% 열린 경우 세 가지 모드를 비교분석하였다. 제어실험결과 온실 내 건구온도의 평균은 모드에 따라 각각 28.2, 27.2 $26.3^{\circ}C$로 나타났으며, 표준편차는 $0.4{\sim}0.8^{\circ}C$이었다. 상대습도는 측창을 완전히 닫은 모드인 0%의 경우 평균 76.3% 정도로서 목표 상대습도인 75%에 상당히 근접해서 제어되고 있었으며, 표준편차가 2.1%로서 다른 모드에 비해 상당히 안정된 범위에서 유지되는 것으로 나타났다. 0%의 모드에서 가장 목표온도로 잘 제어되고 있는 것으로 나타났다.

An Economic Evaluation under Thailand Feed in Tariff of Residential Roof Top Photovoltaic Grid Connected System with Energy Storage for Voltage Stability Improving

  • Treephak, Kasem;Saelao, Jerawan;Patcharaprakiti, Nopporn
    • International Journal of Advanced Culture Technology
    • /
    • 제3권1호
    • /
    • pp.120-128
    • /
    • 2015
  • In this paper, Residential roof top photovoltaic system with 9.9 kW design is proposed. The system composed of 200 Watts solar array 33 panels connecting in series 10 strings and parallels 3 strings which have maximum voltage and current are 350 V and 23.8 A. The 10 kW sinusoidal grid-connected inverter with window voltage about 270-350 is selected to convert and transfer DC Power to AC Power at PCC (Point of Common Coupling) of power system following to utility standard. However the impact of fluctuation and uncertainty of weather condition of PV may decrease the voltage stability and voltage collapse of power system. In order to solve this problem the energy storage such 120 V 1200 Ah battery bank and 30 kVAR capacitor are designed for voltage stability control. The other expensed for installing the system such battery charger, cable, accessories and maintenance cost are concerned. The economic analysis by using investment from money loan with interest about 7% and use own money which loss income of deposit about 3% are calculated as 671,844 and 547,044 for PV system with energy storage and non energy storage respectively. The solar energy from PV is about 101,616 Bath per year which evaluated by using the value of $5kWh/m^2/day$ from average peak sun hour (PSH) of the Thailand and 6.96 Bath/kWh of Feed in Tariff Incentive. The payback periods of four scenarios are proposed follow as i) PV system with energy storage and use loan money is 15 years ii) PV system with no energy storage and use loan money is 10 years iii) PV system with energy storage and use deposit money is 9 years iv) PV system with energy storage and use deposit money is 7 years. In addition, the other scenarios of economic analysis such no FIT support and other type of economic analysis such NPV and IRR are proposed in this paper.