• Title/Summary/Keyword: Roof joint

Search Result 71, Processing Time 0.022 seconds

The strain of the spring ligament complex at different arthrodesis of the hindfoot for treatment of the flatfoot (평편족의 치료로 이용한 관절고정술시 스프링인대군 (spring ligament complex)에서 strain의 변화)

  • Lee, Kyung-Tai;Bae, Joon-Woo
    • Journal of Korean Foot and Ankle Society
    • /
    • v.1 no.1
    • /
    • pp.38-42
    • /
    • 1997
  • It was well known that arthrodesis of the tarsal joint is an exellent procedure to correct the flatfoot deformity for relieving pain. Recently, concept of the selective tarsal joint fusion instead of the triple fusion was developedto preserve the joint motion. To investigate and compare the effect of the each different tarsal fusion, we measured the strain at the spring ligament, medial roof of the medial longitudianl arch. Five fresh frozen cadevar foot specimens, with distal half of the tibia were utilized. The superomedial portion of the spring ligament complex was dissected from the origin to the insertion. For each specimen, a calibrated open liquid metal strain guage was secured along the length of the superomedial portion. Under the specially devised test rig, measurement of the strain was taken at each test condition from the tare weight 18.2 lb followed by 38.2 lb., 82.2 lb and a maximum loads of 134.6 lb. : 1) unfused condition, 2) isolated subtalar fusion 3) isolated talonavicular fusion 4) combined subtalar and talonavicular fusion 5) triple fusion. Statistics showed that siginificant reduction in strain following the triple fusion, and from the subtalar fusion to triple fusion.

  • PDF

The Spatial and Structural Eclectic Modes of the Korean-Western Eclectic Houses at Ojeong-dong Missionary Village (오정동 선교사촌 한양절충 주택의 공간적.구조적 절충방식 연구)

  • Seo, Ho-Seok;Kim, Kyeoung-Soo;Han, Pil-Won
    • Journal of architectural history
    • /
    • v.19 no.4
    • /
    • pp.91-108
    • /
    • 2010
  • The objective of this paper is to clarify the architectural characteristics of the Korean-Western eclectic houses at Ojeong-dong Missionary Village in Daejeon city, focused on the spatial and structural changes due to eclecticism. The consequences of the comparative analysis between the eclectic houses and two reference buildings, Myeongjae residence and Moore house, are as follows. The diverse aspects due to eclecticism can be summarized as two concepts; transformation and simplification. The transformation has appeared in the characteristic spatial elements such as an-madang, entrance and corridor, in the territory organization and the connection between building and yard, and in the roof and wall structures. The simplification has appeared in the layering of the building space, and in the joint of roof and wall. The methods of eclecticism and the resultant aspects from them that are clarified through this study are expected to be referred in examining the new possibilities of the hanok.

A Test on the Aseismic Capacity of a Traditional Three-bay-straw-roof House(I) : Rock Site Condition (전통 초가삼간 가옥의 내진성능 평가 실험(I) : 암반지반 조건)

  • 서정문;최인길;전영선;이종림;신재철
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.1 no.4
    • /
    • pp.11-20
    • /
    • 1997
  • The aseismic capacity of a traditional three-bay-straw-roof wooden house for rock site condition is quantitatively estimated. One 1/4 scale model was tested for the Nahanni Earthquake with peak ground accelerations from 0.1g to 0.6g. The natural frequency of the wooden house in elastic range is 1.66 Hz and 2.15 Hz in longitudinal and transversal direction, respectively. Damping ratio of the house in elastic range is 7%. The horizontal acceleration response of the house is significantly reduced compared with the input motion due to the nonlinear inelastic characteristics of the Sagae-machum joint of the frame. The traditional wooden house has high aseismic capacity in the rock site condition where high frequency contents of motion are predominant.

  • PDF

A Comparative Study on the Correlation the Wooden Structure Between Traditional Korean Architecture and Traditional Korean Ships - Focusing on the Ships of the Goryeo-sun - (전통 건축과 선박의 목구조 상관 관계 비교 연구 - 고려선을 중심으로 -)

  • Kim, Ra-Nee;Han, Dong-Soo
    • Journal of architectural history
    • /
    • v.31 no.6
    • /
    • pp.7-16
    • /
    • 2022
  • Traditional Korean architecture and traditional ships maintained a close relationship with carpenters and tools because wood, the material, was common. This close relationship may have been from the time of ancient architecture and ancient ships. In previous studies, researchers proved the relationship between these two sides through historical records of traditional architecture and traditional ships. This study attempts to prove the structural association using existing remains. As a result, three structural similarities between traditional architecture and traditional ships could be found. First, the types of wood used are similar, and the tools and terms used are similar. Second, the method of distinguishing horizontal and vertical materials and the structure of wood and the method of forming wood are similar. Lastly, the ship carpenters mobilized for the construction of the palace mainly worked on long and curved materials such as the eaves and the ridge of a roof, because this was the work done when the ship was built. Therefore, it can be assumed that the roof structure they created resembles that of the ship.

Assessment of the Thickness of the Roof of the Glenoid Fossa Using Cone Beam Computed Tomography in Asymptomatic Korean Adult Patients

  • Park, Hyun-Jeong;Seo, Yo-Seob;Yoon, A-Hyang;Kim, Ji Hoo;Ryu, Ji-Won
    • Journal of Oral Medicine and Pain
    • /
    • v.44 no.3
    • /
    • pp.112-117
    • /
    • 2019
  • Purpose: The aim of this study was to assess the thickness of the roof of the glenoid fossa (RGF) in Korean adult population without symptoms of temporomandibular disorder (TMD) using cone-beam computed tomography (CBCT). Methods: CBCT Data from 111 Korean adult patients aged ${\geq}25years$ (55 males and 56 females) without signs and symptoms of TMD were analyzed retrospectively in this study. The thickness of the RGF was determined as the perpendicular distance between the 'glenoid fossa line' and 'middle cranial fossa line' on parasagittal and paracoronal reconstructions, respectively. The thickness of the RGF according to sex and age was analyzed using t-tests (p<0.05). Differences were also examined between the right and left sides, and between the paracoronal and parasagittal sides. Results: The mean thickness of the RGF in all subjects was $0.75{\pm}0.39mm$; there was no significant difference in thickness between male ($0.78{\pm}0.36mm$) and female ($0.72{\pm}0.30mm$). We found no correlation between age and the mean thickness of the RGF, when age was grouped by decade. However, when subjects were divided into >40 years and ${\leq}40years$ age groups, the thickness of the RGF was significantly different between the groups. Conclusions: We found that the thickness of the RGF did not differ by sex, but might be affected by aging. Further studies with larger numbers of subjects are needed to confirm the results of this study.

A Study on the Chimi of Hwangnyongsa Temple and the Building Condition of Chimi Installed (황룡사 치미와 사용처의 건축조건 연구)

  • Kim, Sookyung
    • Journal of architectural history
    • /
    • v.31 no.6
    • /
    • pp.59-68
    • /
    • 2022
  • This paper is an architectural historical study on Chimi of Hwangnyongsa Temple. In this research, the shape and cross-section of the chimi are reviewed. The results of the study are as follows. The chimi is a form in which the head part facing the maru is omitted, and the upper and lower body are separated. The upper and lower bonds are assembled into a two types of joint throughout the side of the torso, and then bound with an iron strap. Because of the absence of ridge line in the front, and the narrow curved surface which makes the side plate close to the plane, the entire cross-section is triangular, and the rear plate maintains the shape of the chimi. The naerimmaru connected to the side of the chimi has a slope, so it is clear that the chimi was used on the woojingak-jibung(hipped-roof), and the wing part and back of the chimi are erected on the side roof. The height of the yongmaru and chunyeomaru is about the same and the roofing tiles of those are in contact. The roofing tiles of chunyemaru should be cut to fit the angle of the contacting part. The maru is 30 stories high of roofing tiles as a result of the on-board survey. Based on reference on the shape and timing of the production of chimi, the height of chimi, and the maru is believed to have been built before the Unified Silla Period and used in buildings with at least seven-kan frontage. Buildings corresponding to these construction conditions can be seen as Central hall and East hall in Hwangnyongsa temple.

A Study on the Roof Components of the Traditional Single-Room Square Type Pavilion (한칸형 전통 사각정자의 지붕부 연구)

  • Jeong, Da-In;Kim, Choong-Sik
    • Journal of the Korean Institute of Traditional Landscape Architecture
    • /
    • v.39 no.3
    • /
    • pp.56-64
    • /
    • 2021
  • Pavilion is an important landscape installation in the traditional landscaping and a representative facility that organizes space. To interpret and succeed the traditional landscape space, researches on the shape and structure of the traditional pavilion are also needed. However, researches on the style and structure of the traditional pavilion are difficult to be found. Accordingly this study aimed to identify the structural characteristics of roof part that occupied the largest portion in determining the shape of pavilion. Our research findings are as follows. As a result of analyzing 15 traditional Single-room square pavilions whose structure could be identified, it was found that the main building elements that distinguished the type of roof part in the Single-room square were crossbeam, ridge pole, and baluster. Depending on the presence of roofing members, pavilion was classified into five types: crossbeam, crossbeam+ridge pole, crossbeam+baluster, ridge pole, and baluster. In addition, as a result of analyzing the load and joint that worked on crossbeam based on the shape classification of roof part, it was found that in the traditional Single-room square pavilion, crossbeam was designed to play a balancing role between pillar and load. This study is significant in that it attempted to make a close interpretation of the shape of roof part in the pavilion and the role and function of building elements in terms of size, ratio, and load.

Effect of Joint Persistence on the Formation of Tetrahedral Block Inside an Underground Opening (절리 영속성이 사각 단면 지하공동에서의 사면체 블록 형성에 끼치는 영향)

  • Cho, Taechin
    • Tunnel and Underground Space
    • /
    • v.26 no.6
    • /
    • pp.475-483
    • /
    • 2016
  • A numerical analysis model capable of predicting the shape, the size and the potentiality of collapse of tetrahedral blocks considering the persistence obtained from the field survey of joint distribution around the underground excavation surface has been developed. Numerical functions of analyzing both the exposed trace distribution on the excavation surface and the formation of tetrahedral block controlled by the extent of joint surface have been established and linked to the previously developed three dimensional deterministic block analysis model. To illustrate the reliability of advanced numerical model the case of underground excavation in which the collapse of rock block had practically taken place was studied. Representative orientations of joint sets was determined based on the joint distribution pattern observed on the excavation surfaces. The formation of block on the roof of underground opening was analyzed to unveil the potential tetrahedral block the shape of which was very similar to the collapsed rock block. Mechanisms of collapse process has been also analyzed by considering the three dimensional shape of tetrahedral block.

Thermal Performance of Wooden Building Envelope by Thermal Conductivity of Structural Members (목조건축물 구조부재의 열전도율에 따른 건물외피의 단열 성능)

  • Kim, Sughwan;Yu, Seulgi;Seo, Jungki;Kim, Sumin
    • Journal of the Korean Wood Science and Technology
    • /
    • v.41 no.6
    • /
    • pp.515-527
    • /
    • 2013
  • Building energy simulations which are mainly used in Korea have evaluated the building energy performance with the different thermal conductivity of construction materials. In order to evaluate the energy consumption accurately, the difference in thermal conductivity of the wood used in stud for wooden structure was confirmed from the each simulation. In addition, the thermal transmission of building members and the thermal bridge at the conjunction of building members according to thermal conductivity from each simulation programs were researched. The thermal conductivity of pine that has the largest variation among the energy simulations was applied to the thermal properties of studs in wooden structure. The maximum error between the maximum and minimum thermal transmission of roof, wall, and floor slab was $0.023W/m^2{\cdot}K$. Plus, that thermal bridge at Rafter junction on the roof, roof-wall joint, and floor slab-wall joint was $0.025W/m{\cdot}K$. The heat transfer image for changes in temperature and the heat exchange were analyzed by HEAT2 program. The distorted temperature lines were found around the insufficient insulated connection parts. It was predicted that the temperature at the distorted parts in the analyzed image was lower than that of the other portion of the other structures.

A Study on the Structure and lateral Loading Capacity of Wooden Frame of Ancient Commoner's House (고대 민가의 구조 및 목조 프레임의 수평내력에 관한 연구)

  • 서정문;최인길;전영선;이종림;신재철;허택영
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.1 no.2
    • /
    • pp.31-37
    • /
    • 1997
  • Structural details of the three-bay-straw-roof house which was the most common form of residence as a commoner's house during ancient period are suggested. Wooden frames are used in the house. The typical form of joint used is Sagaemachum. The static lateral loading capacity of the frames is evaluated through the test on full scale models. The effects of joint type at the column head and wooden lattice on the lateral loading capacity and the failure modes of frames are analyzed. The ultimate lateral loading capacity and displacement of the ordinary frame at failure are 1.090 N and 400 mm(1/6rad), respectively. These values for the frame with high column are 4,160 N and 250 mm(1/9.6rad), respectively. The behavior of joint at column head controls the overall lateral loading capacity of the frame and shows very large nonlinearity. The general failure modes of joint for an ordinary frame and a frame with high column are shear and bending failure at the branches of Sagaemachum, respectively.

  • PDF