• 제목/요약/키워드: Roof insulation

검색결과 74건 처리시간 0.022초

Seismic vulnerability of reinforced concrete building structures founded on an XPS layer

  • Koren, David;Kilar, Vojko
    • Earthquakes and Structures
    • /
    • 제10권4호
    • /
    • pp.939-963
    • /
    • 2016
  • According to the new directives about the rational and efficient use of energy, thermal bridges in buildings have to be avoided, and the thermal insulation (TI) layer should run without interruptions all around the building - even under its foundations. The paper deals with the seismic response of multi-storeyed reinforced concrete (RC) frame building structures founded on an extruded polystyrene (XPS) layer placed beneath the foundation slab. The purpose of the paper is to elucidate the problem of buildings founded on a TI layer from the seismic resistance point of view, to assess the seismic behaviour of such buildings, and to search for the critical parameters which can affect the structural and XPS layer response. Nonlinear dynamic and static analyses were performed, and the seismic response of fixed-base (FB) and thermally insulated (TI) variants of nonlinear RC building models were compared. Soil-structure interaction was also taken into account for different types of soil. The results showed that the use of a TI layer beneath the foundation slab of a superstructure generally induces a higher peak response compared to that of a corresponding system without TI beneath the foundation slab. In the case of stiff structures located on firm soil, amplification of the response might be substantial and could result in exceedance of the superstructure's moment-rotation plastic hinge capacities or allowable lateral roof and interstorey drift displacements. In the case of heavier, slenderer, and higher buildings subjected to stronger seismic excitations, the overall response is governed by the rocking mode of oscillation, and as a consequence the compressive strength of the XPS could be insufficient. On the other hand, in the case of low-rise and light-weight buildings, the friction capacity between the layers of the applied TI foundation set might be exceeded so that sliding could occur.

네팔 해비타트(HfH_Nepal) 생태주택 보급현황과 성능개선실험 연구 - 떠라이 평원지역을 중심으로 - (Experiment for the Performance Improvement of Eco House Provided by Habitat for Humanity Nepal(HfH_Nepal) - Case Study of Terai Plain Region, Nepal -)

  • 임윤택
    • KIEAE Journal
    • /
    • 제13권4호
    • /
    • pp.103-112
    • /
    • 2013
  • The Federal Democratic Republic of Nepal(Nepal) is one of the poorest country in the world. People in Nepal are having lots of housing problems including the lack of housing provision. Even Habitat for Humanity Nepal (HfH_Nepal) has developed various programs to diffuse ecological housing, still there are many problems due to financial and technological shortage. The purpose of this study is to verify the effects of suggestion of performance improvement for HfH_Nepal eco house with introduction of the housing situation and efforts to provide sustainable housing by HfH_Nepal in Terai plain. Ideas on CGI sheet roof with poor insulation, double panel bamboo wall and adobe brick wall which can overcome structural and waterproof flaws of the thin single panel bamboo wall. The experiment result shows that both ideas adapted to adobe brick house reduces daily temperature range 50.8% and humidity adjust effect. For the effective provision of adobe brick house, compressive strength was tested for the bricks made with locally available fiber materials. Brick with jute displayed 41.1% betterment than plain brick with closest packing condition while coconut and straw showed 25.1% and 7.9% improvement respectively. Technical and economic problems brought up during the building and experiment process were listed and countermeasures established. This kinds of building prototype houses and experiments can improve the living conditions of people in developing countries with little supplement of resources. Furthermore, consideration of locally available and affordable material can help the social and ecological sustainability in the world.

초단열 슈퍼윈도우의 건물에너지효율등급 적용 연구 (A study on the Insulation Performance of the Super Window applied to building energy efficiency rating)

  • 장철용;김치훈;안병립
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2009년도 추계학술발표대회 논문집
    • /
    • pp.205-210
    • /
    • 2009
  • Generally, the building's windows and ventilation for the purpose of mining and the vista and windows by emotional engineering design area is a growing trend. According to the flow of energy is lost from the building, will be achieved through the walls and roof and windows. Among these, the window through the loss of about 45% of the entire building is big enough to rate. In addition, the building regulation U-value Limitation of window is $3.3W/m^2$ K in southern regions, while U-value Limitation of wall is $0.35{\sim}0.58W/m^2$ K. It means that the energy loss through windows is six times more than it through wall. Therefore, the purpose of this study is to evaluate the environmental performance of the super window system by verification experiment. The results of this study are as follows; 1)Thermal performance of insulated Super Window measured as $1.44W/m^2$ $^{\circ}C$ 2)Required energy for heating was cut down about 5.3% from 266.99 $MJ/m^2$ yr to 252.85 $MJ/m^2$ yr 3)Super Window's reduction rates increased 4.1% from 31.48% to 35.58% when it is compared to normal windows. 4)Building energy efficiency rating elevated from 2nd rating to 1st rating.

  • PDF

제로에너지 솔라하우스(KIER ZeSH)의 에너지 자립도 및 경제성 분석 (The Study on the Energy self-sufficiency and Economic Analysis of KIER Zero Energy Solar House)

  • 정선영;백남춘;유창균;윤응상;윤종호
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2010년도 추계학술대회 초록집
    • /
    • pp.64.1-64.1
    • /
    • 2010
  • In this study, the energy and economic analysis of KIER Zero Energy Solar House (KIER ZeSH) was carried out. KIER ZeSH was designed and constructed in the end of 2009 for the purpose of more than 70% energy self-sufficiency in total load as well as less than 20% of additional construction cost. The several building energy conservation technologies like as super insulation, high performance window, wast heat recovery system, etc and renewable energy system. The renewable heating and cooling system is a kind of solar thermal system combined with geo-source heat pump as a back-up device. The capacity of 3.15kW solar BIPV system was also installed on the roof. The measurement by monitering system of ZeSH was conducted for one year from November 2009 to October 2010. The energy self-sufficiency and economic analysis were conducted based on the this monitering result. As a result, the energy self sufficiency is about 83% which is higher than that of the target and the payback period is 11 years.

  • PDF

한국형 아파트의 난방에너지 분석 1: 위치의 영향 (Analysis of Heating Energy in a Korean-Style Apartment Building 1: The Effect of Location)

  • 유호선;현석균;박유원;김용식;홍희기
    • 설비공학논문집
    • /
    • 제16권1호
    • /
    • pp.101-110
    • /
    • 2004
  • This paper presents an analysis of heating energy for apartment houses in a Korean-style apartment building, paying special attention on the effect of their location. Six representative locations encompass three floors and two placements on each floor. Two different roof types are also considered. In order to incorporate actual tenant's refit, a five-zone model composed of one conditioned and four unconditioned spaces is developed. TRNSYS 15 is adopted to estimate heating energy. The predicted results show fairly good agreements with the available measured data, validating the present model. Heating energy needed for an apartment located at the uppermost and lowermost floors is far greater compared with the case of intermediate floors. In addition, an appreciable difference is found between apartment with and without side end wall. Insulation thickness of walls, floors and underground structure appears to be a dominant factor affecting heating energy, which leads to needs of revision of the related regulation. Ridged-roofs instead of flat-roofs are highly recommended in apartment buildings for effective energy saving. It is finally concluded that the location-dependent, severe imbalance in heating energy should be improved and/or reflected in the policy making process and design standards.

옥상녹화 조성지역의 현황평가 및 이용객 만족도 연구 (The Evaluation of Present Condition and Visitors Satisfaction of Rooftop Greening)

  • 이동근;윤소원;오승환;장성완
    • 한국환경복원기술학회지
    • /
    • 제8권6호
    • /
    • pp.45-58
    • /
    • 2005
  • The objective of this study is to the integrated evaluation of the present condition and satisfaction of visitors of rooftop greening area using quantitative and qualitative method. The thirteen green roofs were selected to investigate environmental variables as like building structure, soil, water, atmosphere and climate environment and questionnaire survey for investigate the satisfaction of visitors was conducted. The results of this study are as follows : remove of the hazardous inflow of species, install rain water recycling facility, install outdoor unit of air condition where not to affect plants in green roof, install safety facilities in the case of making resting place, plant variable vegetation and so on. The result of questionnaire survey are that visitors want to make more comfortable resting space. The more bigger the resting space and privacy, the more satisfaction of visitor became high. In conclusion, green roofs implementation should be considered reduction of temperature and delay of runoff, insulation effect and ecological restoration as well as rooftop greening is focused on the development of resting space nowadays.

절연용 통기완충 시트와 폴리우레탄 도막 방수재를 복합 적층한 탈기 시스템에 관한 연구 (A Study on the Air-Vent System of Complex Layer Applied Poly-Urethane Waterproofing Material and Air-Permeability Buffer Sheet)

  • 오상근;박봉규;고장렬;박윤철;김수련
    • 한국건축시공학회지
    • /
    • 제2권1호
    • /
    • pp.139-146
    • /
    • 2002
  • This study deals with the characterizing and the application like as insulation materials in the joint part in concrete surface layer and waterproofing sheet especially for roof slabs. Using steel materials and butil-rubber tape to band waterproofing sheet and concrete surface together before this waterproofing system will be applied. It can be expected to both the curability and the watertightness by coating poly-urethane 2 or 3 times with sheet surface. Therefore this waterproofing system can be possible to protect water without the damage when vapor is going out from concrete and without air pockets because of the difference temperature inside and out. This system particularly consists of air bents and elastic waterproofing sheet considering the physical damage while water can cause purely physical damage. This system is one of the most efficient ways of waterproofing system without air pocket.

혼화재 및 화학반응제를 혼입한 경량기포콘크리트의 물성 개선 (Improvement of Physical Property of Autoclaved Light-Weight Concrete Using Admixtures and Chemical Reactants)

  • 송훈
    • 한국디지털건축인테리어학회논문집
    • /
    • 제12권4호
    • /
    • pp.87-95
    • /
    • 2012
  • Autoclaved lightweight concrete (ALC), also known as autoclaved aerated concrete (AAC), is a lightweight, precast building material that simultaneously provides structure, insulation. ALC is a unique building material. Because of its cellular nature, it is lightweight, self-insulating, as well as sound and fireproof. ALC products include blocks, wall panels, floor and roof panels, and lintels. Recently, the use of ALC has became increasingly popular. However, ALC have high water absorption, low compressive strength and popout the origin of the low surface strength in its properties. Thus, this study is to improve the fundamental strength by controls of increasing of admixtures and chemical reactants. Admixtures make use of meta kaolin and silica fume, chemical reactants make use of sodium silicate and sodium hydroxide. From the test result, the ALC using admixtures and chemical reactants have a good fundamental properties compared with plain ALC. These good fundamental properties is caused by the admixtures and chemical reactants of ALC by the reason of the micro filling effect and chemical binding of C-S-H gel, tobermolite and quartz.

노후 단독주택의 난방에너지 효율 개선을 위한 대안 선정 방법에 관한 연구 (Alternative Selection Method for Energy Efficiency Improvement of Old Detached House)

  • 황석호
    • 한국태양에너지학회 논문집
    • /
    • 제39권2호
    • /
    • pp.45-55
    • /
    • 2019
  • More than 76% of the detached houses in Korea are over 20 years old. These old detached houses have poor energy efficiency. According to the 2017 Housing Census (Statistics Korea), more than 50% of low-income families live in detached houses. Therefore, the improvement of energy efficiency in old detached houses is needed from the viewpoint of energy welfare. The general method of building energy modelling for the verification of energy efficiency is based on the construction year data of "Building Design Criteria for Energy Saving" due to the cost and time involved in collecting the thermal performance data of buildings. There is poor accuracy with the deterioration of long-term aging of building materials. Also, the selection of alternatives for energy performance improvement is based on the items to be applied, not a performance improvement goal. It is difficult to calculate energy performance that reflects variations in various parameters with dynamic energy simulations. In this study, the influence of long-term aging is used to accurately predict the energy performance of old detached houses. The building energy modelling method is called ENERGY#, which is a static analysis method based on ISO13790. Energy performance is evaluated by a combination of input variables including building orientation, insulation of walls and roof, thermal performance of windows and window/wall ratio, and infiltration rate. Finally, this study provides a way to determine alternatives that meet energy performance improvement goals.

플라스틱온실의 피복방식에 따른 보온 및 광투과 성능 평가 (Estimation of Heat Insulation and Light Transmission Performance According to Covering Methods of Plastic Greenhouses)

  • 이현우;김영식;심상연;이종원;소레이멘디옵
    • 생물환경조절학회지
    • /
    • 제22권3호
    • /
    • pp.270-278
    • /
    • 2013
  • 본 연구는 우리나라 상업용 온실의 보온성능 및 광투과 성능을 개선할 수 있는 피복방식을 결정하는데 필요한 자료를 제공하기 위하여 토마토 재배용 실험온실의 세 가지 피복방식에 대한 보온효과 및 광투과 특성을 평가하였으며 결과를 요약하면 다음과 같다. 공기주입 이중피복온실과 관행 이중피복온실의 관류열손실량이 거의 비슷한 것으로 나타났으나 외부기온이 비슷할 때 피복재와 보온커튼 사이의 온도가 공기주입 이중피복온실이 더 낮게 나타난 것은 공기주입 이중피복온실의 경우 나비식 천창의 틈새로 인한 환기전열손실이 크기 때문인 것으로 판단된다. 따라서 공기주입 이중피복온실에서 나비식 천창을 사용할 경우 틈새 환기전열손실을 줄일 수 있는 대책이 수립되어야 할 것으로 판단된다. 일중피복 온실과 관행이중피복온실의 관류열전달계수에 대한 온실 실험결과와 모형실험결과를 비교한 결과 모두 비슷한 값을 나타내었다. 이러한 결과는 측정된 관류열전달계수가 타당성 있는 값임을 보여주는 것이며 향후 온실의 난방설계시 직접 활용할 수 있을 것으로 기대된다. 공기주입 이중피복온실이 비록 일중피복온실보다는 광투과율이 낮으나 동일한 이중피복온실인 관행이중피복온실보다 광투과율이 높기 때문에 보온을 위해서 이중피복을 설치할 경우에 광투과율을 확보하기 위해서는 공기주입 이중피복방식을 채택하는 것이 바람직할 것으로 판단된다. 공기주입 이중피복온실에 비해 일중피복온실의 피복재 내부표면에서 발생하는 결로량이 큰 이유는 일중피복온실의 피복재 내부표면온도가 훨씬 낮기 때문에 피복재에서의 포화습도가 작아져 내부공기의 절대습도와의 차이가 증가하기 때문인 것으로 판단된다.