• 제목/요약/키워드: Roof

검색결과 2,232건 처리시간 0.031초

공동주택 녹색건축인증기준의 외부공간 환경성능 평가지표 보완방안 - 기후변화 대응 측면을 중심으로 - (Complementary measures for Environmental Performance Evaluation Index of External Space of Green Standard for Energy and Environmental Design for Apartment Complex - Focused on the Respect of Response to Climate Change -)

  • 예태곤;김광현;권영상
    • 대한건축학회논문집:계획계
    • /
    • 제34권1호
    • /
    • pp.3-14
    • /
    • 2018
  • An apartment complex is a building use with great potential to contribute to solving problems related to urban ecological environment and climate change. The first goal of this study is to grasp the current situation of application and limitations of the ecological area rate, which is a representative evaluation index used to evaluate the environmental performance of the external space of an apartment complex in Green Standard for Energy and Environmental Design (G-SEED). The second goal is to propose a prototype of the evaluation index for evaluating greenhouse gas (GHG) reduction performance in order to supplement the evaluation index for the environmental performance of the external space in terms of response to climate change. We analyzed 43 cases of apartment complexes certified according to G-SEED, which was enforced since July 1, 2010, and found application characteristics of each space type and the limitations of ecological area rate. We analyzed overseas green building certification systems such as LEED and BREEAM that derived implications for supplementing the limitations of ecological area rate, which is focused on the evaluation of soil and water circulation function, and set up a development direction of complementary measures. Through analysis of previous studies, relevant regulations and standards, and technical documents of the manufacturer, the heat island mitigation performance of the pavement and roof surfaces of the apartment complex and the carbon uptake performance of the trees in the apartment complex was selected as parameters to yield the GHG reduction performance of the external space of the apartment complex. Finally, a quantitative evaluation method for each parameter and a prototype of the evaluation index for the GHG reduction performance were proposed. As a result of applying the prototype to an apartment complex case, the possibility of adoption and applicability as an evaluation index of G-SEED were proved.

A research on the possibility of restoring cultural assets of artificial intelligence through the application of artificial neural networks to roof tile(Wadang)

  • Kim, JunO;Lee, Byong-Kwon
    • 한국컴퓨터정보학회논문지
    • /
    • 제26권1호
    • /
    • pp.19-26
    • /
    • 2021
  • 역사적 지역에서 발굴되는 문화재는 시대적 배경을 바탕으로 고유의 특징을 가지고 있으며, 역사와 전파 지역의 흐름에 따라 그 문양과 특징이 조금씩 변화하는 것을 볼 수 있다. 어떤 지역에서 발굴된 문화재는 그 당시의 문화를 대표하며 온전한 모습을 유지하는 것도 있지만, 대부분이 파손/손실되거나 일부분으로 나누어져 그 구성을 연구하고 파손된 부분을 복구하기 위해 많은 전문가가 동원된다. 이 연구의 목적은 이러한 복원연구에 인공지능 신경망을 통해 과거의 문양과 패턴들을 학습시키고, 출토된 문화재에서 손실된 부분을 복원시키는 데 있으며, 문화재를 복원하기 위해 기본적인 생성적 적대 신경망인 GAN(Generative Adversarial Network)[1]을 사용한다. 연구에서는 GAN을 기반으로 출토된 문화재 일부를 기반으로 하여 손상/손실된 나머지 부분을 복구한 연구 과정으로, 학습에 기반이 되는 온전한 문화재의 이미지로 훈련을 하고, 일부를 마음대로 손상해 복구할 수 있도록 했다. 연구는 문화재 복구에 있어, 시대적 특징을 어느 정도 복구하는지, 색상과 재질을 복구하는지에 중점을 두고 있다. 마지막으로는 실제 출토된 비슷한 문화재를 기반으로 훈련된 신경망을 사용하여 문양을 복구함으로써 인공신경망의 적용 범위를 연구한다.

GIS와 전산유체역학 모델을 이용한 기상 조건이 건물 화재에 미치는 영향 연구 (A Numerical Study on the Effects of Meteorological Conditions on Building Fires Using GIS and a CFD Model)

  • 문다솜;김민지;김재진
    • 대한원격탐사학회지
    • /
    • 제37권3호
    • /
    • pp.395-408
    • /
    • 2021
  • 본 연구에서는 GIS와 CFD 모델을 이용하여 풍속과 풍향이 건물 화재에 미치는 영향을 조사하였다. 이를 위해, 2020년 10월 8일 울산의 한 아파트에서 발생한 화재 사고에 대한 수치 실험을 수행하였고, 현실적인 기상 조건을 반영하기 위하여 국지기상예보시스템(LDAPS)의 바람과 온위 자료를 초기·경계 자료로 사용하였다. 먼저, 현실적인 경계 조건을 사용하여 두 가지 수치 실험을 수행하였다(규준 실험에서는 건물 화재를 고려하고, 다른 실험에서는 건물 화재를 제외하고는 규준 실험과 동일한 기상 조건 이용). 그런 다음, 규준 실험과 유입 풍속과 방향이 다른 4개의 수치 실험을 추가로 수행하였다. 수치 실험 결과, 발화 지점이 건물 풍상측에 위치할 때에는 화재로 인한 강한 상승 기류가 건물 지붕과 풍하측 지역에 영향을 미쳤다. 또한, 대피층(15층)은 건물 풍상 측 벽면의 화재를 풍하측으로 확산시키는 역할을 했다. 유입 풍속이 약할수록 발화점 주변으로의 화재가 좁게 확산되었지만 건물 위로 화염이 도달하는 고도는 상승했다. 유입 풍향이 반대인 경우, 발화 지점이 풍하측에 위치할 때에는 화염이 건물 풍상 측으로 확산되지 않았다. 본 연구 결과는 풍속과 풍향이 화재가 발생한 건물 주변의 흐름과 온도(화염) 분포에 중요하다는 것을 보여준다.

부여 부소산사지 출토 치미의 재 복원을 통한 제작기법 (Restoration of the Chimi Excavated from the Busosan Temple Site in Buyeo and Study of Its Production Techniques)

  • 황현성;나아영
    • 박물관보존과학
    • /
    • 제27권
    • /
    • pp.1-22
    • /
    • 2022
  • 부여 부소산사지 출토 치미는 지난 1978년 부여박물관에서 복원하였지만, 오랜 시간이 지남에 따라 복원재료인 석고가 열화되면서 치미의 무게를 감당하지 못해 부분적으로 심하게 파손되어 있었다. 이를 보강하기 위해 응급으로 에폭시 수지를 사용하여 몸통 내부와 일부 꼬리 부분을 여러 차례 보강한 흔적이 있었다. 전시 기간에 맞춰 치미를 이동하기 위해 상태 점검을 하던 중 치미의 하부 몸통 및 날개 부분의 안정성이 매우 취약하다고 판단되어 다시 복원하기로 하였다. 재 복원하기 위해 치미를 해체하는 과정에서 당시 도공의 제작 방법을 유추해볼 수 있는 여러 제작흔적이 남아 있어 치미의 제작 방법을 연구할 수 있는 좋은 자료로 판단되어 조사하였다. 본 논문은 재 복원을 위해 해체하는 과정에서 밝혀진 부소산사지 치미의 제작기법을 정리하였다. 3차원 기술을 이용해 치미를 스캔한 후 해체 과정에서 살펴본 치미의 제작기법을 바탕으로 수직적이고 경직된 형태를 자연스러운 형태로 수정하고 복원하여 이전 재료를 교체함으로써 복원제의 내구성을 강화하였다. 모델링한 출력물을 본래 편과 접합하고 소실된 형태를 새롭게 만들어 완형으로 재 복원하였다.

도로 주변 지역의 CCTV영상을 이용한 야간시간대 미세먼지 농도 추정 (Estimation of PM concentrations at night time using CCTV images in the area around the road)

  • 원태연;어양담;조수민;송준영;윤준희
    • 한국측량학회지
    • /
    • 제39권6호
    • /
    • pp.393-399
    • /
    • 2021
  • 본 연구는 다양한 미세먼지 농도 환경의 야간 CCTV 영상을 학습 시켜 영상에 의한 미세먼지 농도 추정에 대한 실험을 진행하였다. 주간 영상의 경우 많은 관련 연구가 존재하였고, 영상의 다양한 텍스쳐와 밝기 정보가 잘 표현되어 학습에 영향을 주는 정보가 뚜렷하다. 하지만 야간 영상의 경우 주간 영상에 비해 담고 있는 정보가 적고 야간 영상만 사용한 연구가 드물다. 따라서 차량과 가로등 같은 광원 때문에 특징이 균일하지 못한 야간 촬영 영상들과 비교적 광원이 일정한 건물 지붕, 건물 벽, 가로등을 ROI로 결합한 실험을 진행하였다. 이후 야간 영상으로 딥러닝 기반 미세먼지 농도 추정이 가능한지 상관도를 주간 실험과 비교 분석하였다. 실험 결과, 지붕 ROI (Region of Interest) 학습한 경우의 결과 값이 가장 높았고, 전체 영상과의 결합 학습모델은 더 향상된 결과를 보여주었다. 전체적으로 R2가 0.9를 상회하여 야간 CCTV 영상으로부터 미세먼지 추정이 가능함을 나타내고 있고, 날씨 자료의 추가 결합 학습은 실험 결과에 크게 영향을 주지 않은 것으로 계산되었다.

Comparison of Environment, Growth, and Management Performance of the Standard Cut Chrysanthemum 'Jinba' in Conventional and Smart Farms

  • Roh, Yong Seung;Yoo, Yong Kweon
    • 인간식물환경학회지
    • /
    • 제23권6호
    • /
    • pp.655-665
    • /
    • 2020
  • Background and objective: This study was conducted to compare the cultivation environment, growth of cut flowers, and management performance of conventional farms and smart farms growing the standard cut chrysanthemum, 'Jinba'. Methods: Conventional and smart farms were selected, and facility information, cultivation environment, cut flower growth, and management performance were investigated. Results: The conventional and smart farms were located in Muan, Jeollanam-do, and conventional farming involved cultivating with soil culture in a plastic greenhouse, while the smart farm was cultivating with hydroponics in a plastic greenhouse. The conventional farm did not have sensors for environmental measurement such as light intensity and temperature and pH and EC sensors for fertigation, and all systems, including roof window, side window, thermal screen, and shading curtain, were operated manually. On the other hand, the smart farm was equipped with sensors for measuring the environment and nutrient solution, and was automatically controlled. The day and night mean temperatures, relative humidity, and solar radiation in the facilities of the conventional and the smart farm were managed similarly. But in the floral differentiation stage, the floral differentiation was delayed, as the night temperature of conventional farm was managed as low as 17.7℃ which was lower than smart farm. Accordingly, the harvest of cut flowers by the conventional farm was delayed to 35 days later than that of the smart farm. Also, soil moisture and EC of the conventional farm were unnecessarily kept higher than those of the smart farm in the early growth stage, and then were maintained relatively low during the period after floral differentiation, when a lot of water and nutrients were required. Therefore, growth of cut flower, cut flower length, number of leaves, flower diameter, and weight were poorer in the conventional farm than in the smart farm. In terms of management performance, yield and sales price were 10% and 38% higher for the smart farm than for the conventional farm, respectively. Also, the net income was 2,298 thousand won more for the smart farm than for the conventional farm. Conclusion: It was suggested that the improved growth of cut flowers and high management performance of the smart farm were due to precise environment management for growth by the automatic control and sensor.

철도시설물 미소변형 모니터링을 위한 D-InSAR 기법 연구 (A Study on the D-InSAR Method for Micro-deformation Monitoring in Railway Facilities)

  • 김병규;이창길;김겨울;유민택;이일화
    • 한국지반공학회논문집
    • /
    • 제38권11호
    • /
    • pp.43-54
    • /
    • 2022
  • 철도 시설물에서는 침하 및 틀림에 의해 사고가 발생할 수 있어 변형을 적정수준으로 유지하는 것이 중요하다. 변형을 모니터링하기 위해서는 과도한 인력과 시간이 필요하기 때문에 이를 개선하기 위해 위성원격탐사 기술 중 하나인 InSAR 기술을 활용하고자 한다. 장기적인 시계열 분석을 위해서는 25장 이상의 고해상도 위성정보로 PS-InSAR 기법을 활용 할 수 있으나, 신속하고 단기적인 방법으로 2장 이상의 위성정보로 D-InSAR 기법으로 미세 변형을 관측할 수 있다. 본 연구에서는 TerraSAR-X 영상을 이용하여 D-InSAR 기법을 적용하여 오송 철도종합시험선로의 지반 침하량 및 구조물 변형량을 구하였다. 구조물과 사면에 반사강도를 높일 수 있는 코너리플렉터를 인공적으로 설치하여 변위 값을 임의로 수 mm 조정하여 이를 검증 할 수 있도록 하였다. D-InSAR 분석 결과로부터 적절한 코너리플렉터 배치도를 산출하였고, 궤도, 사면, 구조물 구역의 변위량을 측정하였다. 더불어 임의로 조정한 코너리플렉터의 변위값을 D-InSAR 분석으로 산출하였다. 본 연구 결과로부터 D-InSAR 결과를 철도시설물과 같은 광범위한 인프라 시설에 모니터링을 위한 기법으로 활용 가능함을 확인하였다.

화재 위험요소의 도출을 위한 노후건축지구의 공간구성 특성분석 (Analysis of Spatial Characteristics of Old Building Districts to Evaluate Fire Risk Factors)

  • 손병훈;강경하;류정림;노승준
    • 한국건축시공학회지
    • /
    • 제22권1호
    • /
    • pp.69-80
    • /
    • 2022
  • 30년 이상 된 노후 건축물의 비율은 2005년 29.0%에서 2019년 37.8%로 증가하였다. 이러한 노후 건축물은 화재 안전 성능 등 건축 관련 안전기준이 부재했던 시기에 조성된 건축물이다. 사용 과정에서 불법적인 변경과 증축이 이뤄져 안전에 더욱 취약해졌을 것으로 예상된다. 다중이용건축물 등 대형재난을 막기 위해 소방 안전 조사가 이뤄지고 있지만 대규모 노후 건축물이 밀집한 지역구 차원에서는 조사가 이뤄지지 않고 있다. 따라서 노후 건축물이 밀집한 노후 건축지구에서 화재 위험 요인을 도출하기 위해 우선 건축물의 구성 특성을 분석하였다. 화재 위험 요소 도출을 위한 노후 건축지구의 공간적 특성을 살펴보기 위하여 건축물 구조, 용도, 지붕형태, 사용승인연도를 기준으로 분석한 결과, 건축물 사용승인일을 기준으로 건축물의 주구조가 가장 큰 영향이 있었으며, 건축물 주구조를 기준으로 주거환경개선지구의 경우 지붕형태, 그 외 지역은 건축물의 주구조가 가장 큰 영향이 있는 것으로 나타났다.

시게루 반 전시공간의 생태적 특성과 변화 연구 (A Study on the Ecological Characteristics and Changes of the Shigeru Ban Exhibition Space)

  • 티엔휘;윤지영
    • 한국콘텐츠학회논문지
    • /
    • 제22권2호
    • /
    • pp.147-161
    • /
    • 2022
  • 본 연구는 2000년 이후 시게루 반이 설계한 대표적인 임시전시관 3곳과 상설전시관 3곳을 대상으로 반의 전시공간의 생태적 특성과 디자인 특성에 대한 변화를 고찰하였다. 생태건축에 관한 개념 및 특성, 전시공간의 디자인 특성 등에 대한 문헌고찰을 통해 전시공간의 디자인 특성과 생태건축의 디자인요소에 대한 분석틀을 도출하였다. 연구 결과 건축규모, 공간구성, 기능, 재료 및 기술 측면에서 임시전시관과 상설전시관 사이에 큰 변화가 있다. 시게루 반의 임시전시관은 재활용 가능한 재료로 종이튜브, 컨테이너 등을 현장에서 전시 위주의 단층 공간으로 조립해 조립방법이 단순하고 공기가 짧아 전시회가 끝난 후 전시관이 철거되어 그 재료가 다음 전시장으로 옮겨지거나 재활용됐다. 한편 상설전시관은 철근콘크리트를 주체로 하고 목재와 유리재료를 다량으로 사용해 전시공간과 휴게공간을 분리시킨 다층 복합문화공간을 조성했다. 또한 시게루 반의 전시관을 영구건축으로서 친환경적인 재료와 혁신적인 구조기술, 기후설계 개념을 적용하는 등 지속가능한 건축을 실현하고 있다. 생태적 특성 측면에서 임시전시관은 건축자재를 모두 재활용할 수 있어 철거 후 산업폐기물이 발생하지 않았다. 상설전시관은 지붕, 벽면 등에 친환경 목재를 사용해 교체와 보수가 용이하며 두 가지 유형의 전시관은 모두 자연채광과 환기를 통해 자원과 에너지를 절약을 등 생태적 건축을 보다 지속가능한 방향으로 변화시켜 가고 있다.

LCD 제조공정 종사근로자의 극저주파자기장 노출특성 연구 (A Study on the Extremely Low Frequency Magnetic Fields Exposure Characteristics of Workers in LCD Manufacturing Process)

  • 김준범;강준혁;정은교;정기효
    • 한국산업보건학회지
    • /
    • 제32권1호
    • /
    • pp.10-20
    • /
    • 2022
  • Objectives: The aim of this study is to evaluate exposure levels of the extremely low frequency magnetic fields(ELF-MF) radiated from various electric facilities in Liquid Crystal Display(LCD) manufacturing processes. Methods: This study measured the exposure levels of personal and local ELF-MF for the electronic facilities installed in two LCD manufacturing companies. Samplers were installed around workers' waist during working hours to identify personal exposure levels, and direct reading equipment were located at 3 cm, 10 cm, and 30 cm away from the surface of the electronic facilities to measure local exposure levels. Average and maximum(ceiling) values were calculated for personal and local exposure levels. Results: Average and maximum of personal exposure levels for each worker were 0.56(mean) ± 0.02(SE) µT and 6.31 ± 0.75 µT, respectively. Statistical analyses of the study found that maximum of the personal exposure levels for engineers was significantly higher than that for operators since engineers spend more time near the electronic facilities for repairing. The range of maximum personal exposure levels was 0.50 ~ 43.50 µT and its highest level was equivalent to 4.35 % of ACGIH(American Conference of Governmental Industrial Hygienists) exposure limit value(1 mT). Maximum of local exposure levels was 8.18 ± 0.52 µT and the electronic facilities with higher exposure levels were roof rail and electric panel, which were not related to direct manufacturing. The range of maximum local exposure levels was 0.60 ~ 287.20 µT and its highest level was equivalent to 28.7 % of the ACGIH exposure limit value. Lastly, the local exposure levels significantly decreased as the measurement distance from the electronic facilities increased. Conclusions: Maximum of personal and local exposure levels did not exceed the exposure limit value of ACGIH. However, it is recommended to keep the workers as far as possible from the sources of ELF-MF.