• 제목/요약/키워드: Roof

검색결과 2,231건 처리시간 0.028초

섬유보강 다공성 옥상녹화 황토콘크리트의 물리·역학적 및 온도변화 특성 평가 (Physical·Mechanical and Temperature Properties of Fiber Reinforced Porous Green Roof Hwang-toh Concrete)

  • 오리온;김춘수;김황희;전지홍;권완식;박찬기
    • 한국농공학회논문집
    • /
    • 제55권4호
    • /
    • pp.65-72
    • /
    • 2013
  • The physical, mechanical, water purification and temperature properties of fiber reinforced porous hwang-toh green roof concrete have been evaluated in this study. The effect of the depending on replacement ratio of blast furnace slag to cement was investigated such that the replacement ratio is varied to 0 % and 30 %. Also, the replacement ratios of hwang-toh were 0, 20 and 30 %. The polyvinyl alcohol fiber was used for the reinforcing fiber. A series of pH test, unit weight, void ratio, compressive strength, after purification and variation of temperature test have been performed to evaluate the performance, water purification effect and temperature properties of the fiber reinforced porous hwang-toh green roof concrete. The test results indicate that the physical and mechanical properties of fiber reinforced porous hwang-toh green roof concrete is affected by the replacement ratio of the blast furnace slag and hwang-toh contents. Results of purifying water showed that the water purification effect of porous hwang-toh green roof concrete is about 40 %. Also, the temperature properties test results indicate the green roof blocks using fiber reinforced porous hwang-toh green roof concrete have insulation and temperature reduction effect.

압전재료 센서 액츄에이터를 이용한 자동차루프의 능동진동제어 (Active Vibration Control of An Automotive Roof using Piezoelectric Sensor and Actuator)

  • 문성진;김찬묵;강영규
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2004년도 추계학술대회논문집
    • /
    • pp.834-839
    • /
    • 2004
  • In this paper, we have studied on the active vibration control of an automotive roof in passenger car's structure using piezoelectric material as the actuator and sensor attached on the surface of the automotive roof, As a control algorithm, negative velocity feedback control method is used in the study and the position of the sensor is almost attached on the nearest position of maximum normal stresses occurring while the roof is vibrating due to disturbance or exciting, Also, the actuator is attached on the other side mostly collocated to the sensor. The optimum positions have the maximum stresses of the roof which have been found in the result of the finite element analysis using Nastran software, As the fundamental experiments, a beam and plate have also been implemented to verify the performance of vibration suppression. Finally the experiment of the roof has been carried out and The roof experiment has just given a possibility to an active vibration control of the automotive structure still not applied for passenger cars.

  • PDF

A Case Study of Extensive Green Roof System for Tropical Climate in Malaysia

  • Kok, Kah Hoong;Jung, Kwansue;Sidek, Lariyah Mohd;Abidin, Mohd Roseli Zainal;Felix, Micah Lourdes
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2016년도 학술발표회
    • /
    • pp.329-329
    • /
    • 2016
  • Rapid urbanization has taken environmental toll on the surrounding which can be witnessed by the advent of global warming and climate change. Driven by environmental needs, Green Building Index (GBI) was established in Malaysia to drive initiative to lead the property industry towards becoming more environmental friendly. Green roofs (roof with vegetated cover) as one of the assessment criteria of GBI, are gaining attention in the Malaysian society as a versatile new environmental friendly mitigation technology. This paper evaluates the qualitative and quantitative performances of an extensive green roof at Humid Tropics Centre under local tropical climate. Simulations showed that the extensive green roof system could reduce the peak discharge up to 26% in relation to impervious brown roof. Its reduction ability decreased for storms with intense rainfall. Increment of pH was observed for the green roof runoff and the runoff water quality ranged between class I and II under Water Quality Index (WQI). High concentrations of phosphate were noticed in the runoff samples and substrates (fertilized planting soil) might be the potential contributor. Findings indicate that there was a reduction of around $1.5^{\circ}C$ for indoor temperature of the building after installation of the extensive green roof.

  • PDF

한국잔디식재 옥상녹화의 온도저감 및 증발산량 평가 (Assessment of Temperature Reduction and Evapotranspiration of Green Roof Planted with Zoysia japonica)

  • 김세창;이현정;박봉주
    • 한국환경과학회지
    • /
    • 제22권11호
    • /
    • pp.1443-1449
    • /
    • 2013
  • This was an experimental study to evaluate temperature reduction and evapotranspiration of extensive green roof. Three test cells with a dimension of $1.2(W){\times}1.2(D){\times}1.0(H)$ meters were built using 4-inch concrete blocks. Ten-centimeter concrete slab was installed on top of each cell. The first cell was control cell with no green roof installed. The second and third cells were covered with medium-leaf type Zoysiagrass (Zoysia japonica) above a layer of soil. Soil thickness on the second cell was 10cm and that on the third cell was 20cm. Air temperature, relative humidity and solar irradiance were measured using AWS (automatic weather system). Temperature on top surface and ceiling of the control cell and temperature on top surface, below soil and ceiling of green roof cells was measured. Evapotranspiration of the green roof cells were measured using weight changes. Compared with temperature difference on the control cell, temperature difference was greater on green roof cells. Between two green roof cells, the temperature difference was greater on the third cell with a thicker soil layer. Temperature differences below soil and on ceilings of green roof cells were found greater than those of the control cell. Between the green roof cells, there was no difference in the temperature reduction effects below soil and on ceilings based on substrate depth. In summary, green roof was found effective in temperature reduction due to evapotranspiration and shading effect.

개폐식 지붕구조의 움직임에 대한 공간구조물의 진동해석 (Vibration Analysis of Space Structure with Retractable Roof)

  • 김기철;강주원;김현수
    • 한국공간구조학회논문집
    • /
    • 제11권1호
    • /
    • pp.113-120
    • /
    • 2011
  • 지붕구조의 개폐가 가능한 체육시설 및 복합시설은 대공간구조물의 장점을 잘 나타내고 있으며 대공간구조물의 전천후 사용이 가능하도록 하였다. 개폐식 지붕구조는 구조형식, 마감재료, 개폐방식에 따라서 매우 다양하며 개폐방식에 따라서 중첩방식, 수평이동방식, 주름접기방식 등으로 구분할 수 있다. 특히 중첩방식이나 수평이동방식에 의한 지붕구조의 움직임은 주행하중, 충격하중, 관성력 및 제동력과 같은 동적하중이 구조물에 가해질 수 있으므로 이에 대한 대공간구조물의 진동해석이 필요할 것으로 사료된다. 지붕구조의 움직임에 의한 주행하중은 이동질량 또는 이동하중으로 적용할 수 있으나 비교적 움직임이 느린 개폐식 지붕구조에 의한 동적하중은 아동하중으로 적용하는 것이 타당하다. 따라서 본 논문에서는 지붕구조의 개폐로 야기되는 이동하중에 대한 새로운 적용방법을 제안하고 이를 이용하여 개폐식 지붕의 개폐속도에 따른 대공간구조물의 진동해석을 수행하였다. 본 논문에서 제안된 등가 이동하중은 지붕구조 개폐에 의한 대공간구조물의 진동해석에 있어서 매우 용이하게 활용할 수 있다.

도시 협곡에서 건물 지붕 냉각이 스칼라 물질 확산에 미치는 영향 (Effects of Building-roof Cooling on Scalar Dispersion in Urban Street Canyons)

  • 박수진;김재진
    • 대기
    • /
    • 제24권3호
    • /
    • pp.331-341
    • /
    • 2014
  • In this study, the effects of building-roof cooling on scalar dispersion in three-dimensional street canyons are investigated using a computational fluid dynamics (CFD) model. For this, surface temperature of building roof is systematically changed and non-reactive pollutants are released from street bottom in urban street canyons with the aspect ratio of 1. The characteristics of flow, air temperature, and non-reactive pollutant dispersion in the control experiment are analyzed first. Then, the effects of building-roof cooling are investigated by comparing the results with those in the control experiment. In the control experiment, a portal vortex which is a secondary flow induced by ambient air flow is formed in each street canyon. Averaged air temperature is higher inside the street canyon than in both sides of the street canyon, because warmer air is coming into the street canyon from the roof level. However, air temperature near the street bottom is lower inside the street canyon due to the inflow of cooler air from both sides of the street canyon. As building-roof temperature decreases, wind speed at the roof level increases and portal vortex becomes intensified (that is, downdraft, reverse flow, and updraft becomes stronger). Building-roof cooling contributes to the reduction of average concentration of the non-reactive pollutants and average air temperature in the street canyon. The results imply that building-roof cooling has positive effects on improvement of thermal environment and air quality in urban areas.

강건설계를 이용한 층서두께 배열과 루프볼트 지보설계에 관한 연구 (A Study on the Stratum Thickness Arrangement and Roof Bolt Support Design using Robust Design)

  • 장명환
    • 터널과지하공간
    • /
    • 제28권2호
    • /
    • pp.142-155
    • /
    • 2018
  • ${\bigcirc}{\bigcirc}$광산은 광체주변에 미고결된 층서가 불규칙하게 발달되어 있다. 본 연구는 효율적인 루프볼트(roof bolt) 시공을 위하여 불규칙한 층서의 두께를 체계적으로 배열하고 이에 대응하는 지보시스템을 제시한 것이다. 층서별 두께를 조합한 81개의 경우의 수를 강건설계에 의하여 9개의 사례로 한정하여 지보설계를 하였다. 각 사례에 대하여 천반하중으로 작용할 수 있는 하중고를 층서의 특성과 RMR에 의하여 결정하였다. 하중고에 의한 하중범위를 블록형상과 아치형상으로 가정하여 계산하였다. 두 방법의 평균하중으로 루프볼트의 지보력을 감안한 지보설계를 하였다. 지보설계에 대한 수치해석 결과 케이블 볼트는 선단정착 방식보다 전면접착 방식이 천반유지에 더 효과적인 것으로 분석되었다. 시공결과 천반의 컨트롤은 가능하였으나 갱도측벽의 변형으로 천반 전체가 하부로 조금씩 침강하는 현상을 보였다.

Field measurements of wind pressure on an open roof during Typhoons HaiKui and SuLi

  • Feng, Ruoqiang;Liu, Fengcheng;Cai, Qi;Yan, Guirong;Leng, Jiabing
    • Wind and Structures
    • /
    • 제26권1호
    • /
    • pp.11-24
    • /
    • 2018
  • Full-scale measurements of wind action on the open roof structure of the WuXi grand theater, which is composed of eight large-span free-form leaf-shaped space trusses with the largest span of 76.79 m, were conducted during the passage of Typhoons HaiKui and SuLi. The wind pressure field data were continuously and simultaneously monitored using a wind pressure monitoring system installed on the roof structure during the typhoons. A detailed analysis of the field data was performed to investigate the characteristics of the fluctuating wind pressure on the open roof, such as the wind pressure spectrum, spatial correlation coefficients, peak wind pressures and non-Gaussian wind pressure characteristics, under typhoon conditions. Three classical methods were used to calculate the peak factors of the wind pressure on the open roof, and the suggested design method and peak factors were given. The non-Gaussianity of the wind pressure was discussed in terms of the third and fourth statistical moments of the measured wind pressure, and the corresponding indication of the non-Gaussianity on the open roof was proposed. The result shows that there were large pulses in the time-histories of the measured wind pressure on Roof A2 in the field. The spatial correlation of the wind pressures on roof A2 between the upper surface and lower surface is very weak. When the skewness is larger than 0.3 and the kurtosis is larger than 3.7, the wind pressure time series on roof A2 can be taken as a non-Gaussian distribution, and the other series can be taken as a Gaussian distribution.

대구시 중구의 옥상녹화를 통한 환경 및 경제적 편익 분석 (An Analysis of Environmental and Economic Benefits of Green Roof in Jung-Gu, Daegu)

  • 김수봉;장중근
    • 한국환경과학회지
    • /
    • 제16권5호
    • /
    • pp.603-610
    • /
    • 2007
  • Recent urban sprawl has destroyed various kinds of green space in tile city. It has affected duality of people's life in the city, as well as urban ecosystem. Recent study shows the possibilities of roofs as green spaces in urban central site where the land costs are generally high. This research focuses on Jung-Gu district in Daegu Metropolitan city as a study area and calculates possible area of green roof using 2002 Autocad program based on aerial photographs and land registration maps. And the purpose of this research is to analyze environmental and economic effects of green roof. The environmental effects are as follows. It is expected that $91,106m^2$ green spaces, 12.13 % of study site, will be added if green roof is performed in the study site. It is assumed that the expanded areas could reduce the highest temperature to $0.5-1.0^{\circ}C$ during the summer in terms of environmental effect. And the following shows the economic effects. If green roof and greening urban central site are created as a same size of $91,106m^2$, it will be expected that the costs of green roof will be much more in-expensive than about 98 billions won. It will be also found that the expense of cooling energy can be saved out about 8 millions won per day in summer, if grass planting is accomplished on the possible areas of green roof in the study site. Therefore, it is desirable to take legal supports such as enacting regulations to activate green roof for more environmental and economic effects. For instance, green roof for public institutions, school and model area selection are desirable method to publicize the effect of greening program for citizen's participation.

정면 3칸 팔작지붕 불전의 추녀부 처마 곡선 구성 방법에 관한 연구 (A Study on Constructing Eave Curve of Part Chunyeo in the Three-Kan Hipped and Gable-roofed Buddhist Temples)

  • 위소연;성대철;신웅주
    • 건축역사연구
    • /
    • 제26권4호
    • /
    • pp.35-44
    • /
    • 2017
  • The purpose of this study is to classify three-Kan hipped and gable-roofed Buddhist temples with the construction of their eave curve of part chunyeo and examine the characteristics and causes. The conclusions have been drawn as follows: First, there are largely three ways to secure symmetry in eave curve of part chunyeo. One is to obtain symmetry in eave curve of part chunyeo by making the size of eaves curves on well sides the same and forming symmetric curves in the front section along with the side roof and then forming the straight line in the central part (hereinafter referred to as the long straight line section method). The second is a method to enlarge eaves curves in the front and form eaves curves on the roof section to be symmetric (hereinafter referred to as the front is larger than side eaves curves method). The third is the method to make eaves curves in the roof section to be symmetric by adjusting the roof length and making difference between the front and side roof's length minimum (hereinafter referred to as the roof length-controlling method). Second, there are 16 cases applying two or more methods, and they are the mainstream. Third, there are 12 cases applying the front is larger than side eaves curve method and roof length-controlling method both, which seems to be the most universal. To sum up, they secured symmetry in roof edges considering the construction of seonjayeon and pyeongyeon according to the size of the structure, recognition on the directions of entrance into the area of the building, forms of planes, harmony with structures around, recognition on roof curves in accordance with the size, and also structural faults in the chunyeo part.