• Title/Summary/Keyword: Rogowski coil

Search Result 57, Processing Time 0.032 seconds

Intelligent Substation Construction of 154kV Class (154kV 인텔리전트 변전소 구축)

  • Kim J B.;Chung Y. H.;Song W. P.;Choi I. H.;Kim J. H.;Lee D. I.;Koh H. S.
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.524-526
    • /
    • 2004
  • We perform intelligent substation construction of 154kV class with KEPRI. The intelligent substation is build in Gochang 765kV testing facility and consists of electronic instruments, digital control panel, remote monitoring and diagnosis system, and digital relay system. Rogowski coil type CT(RCT) and capacitive voltage divider(CVD) are applicable for instrument transformer of conventional type. Digital control panel(UP) replaces local panel which is drived by mechanical operation. For monitoring condition of GIS and TR, various sensors are used. In this paper, we report the synopsis and the progress state of project.

  • PDF

Output Characteristics of Current Sensor and Voltage Sensor Built in Epoxy Spacer (에폭시 스페이서에 내장되는 전류센서와 전압센서의 출력 특성)

  • Park, Seong-Hee;Kim, Kil-Sou;Kang, Seong-Hwa;Lim, Kee-Joe
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.2
    • /
    • pp.361-366
    • /
    • 2007
  • In the distribution networks, it is necessary to develop small and light voltage and current sensor for compact and digitalized switchgears. For this purpose, some researches have been continuing till now, CT(current transformer) and VT(voltage transformer) are one of that research. But conventional CT and VT have some problems, that is, have big size and saturation characteristics because of used to iron core. In this paper, CS(current sensor) and VS(voltage sensor), have some merits measuring of current and voltage magnitude as a alternated conventional equipment, were studied. So, this paper shows the process CS and VS design method, equivalent circuit and output result, respectively. As a result of this test, proposed CS and VS have linearity for the output, no saturation.

다양한 공정 주파수에서 유도 결합 플라즈마의 플라즈마 밀도와 에너지 전달 효율 측정

  • Lee, Jae-Won;Choe, Ik-Jin;Lee, Yeong-Gwang;Jeong, Jin-Uk
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.02a
    • /
    • pp.242-242
    • /
    • 2011
  • 현재 반도체 및 디스플레이 장비들이 공정 매개변수 및 플라즈마 변수를 독립적으로 제어하기 위하여 전원 주파수를 다양하게 사용된다. 플라즈마의 상태나 에너지 전달 효율은 반도체 및 디스플레이 공정에 중요한 요소이다. 따라서 플라즈마 발생장치의 전원 주파수를 바꾸었을 때의 플라즈마 밀도와 에너지 전달 효율에 관하여 연구하였다. 공정용 유도 결합 플라즈마(ICP)를 발생시키기 위하여 신호 발생기에서 전력 증폭기와 임피던스 정합회로(Matcher)를 거쳐 반응 용기에서 플라즈마를 발생시켰다. 6 mTorr의 압력에서 주파수는 13.56 MHz에서부터 80 MHz까지, 15~60 W의 전력을 인가하였다. 플라즈마의 에너지 효율을 측정은 제작한 로고스키코일(Rogowski Coil)을 이용하여 시스템 전반을 등가회로로 계산하였으며, 플라즈마 밀도는 반응용기 중앙에서 부유 탐침법을 적용하여 도출하였다. 같은 전력 조건에서 주파수가 증가함에 따라 플라즈마 밀도가 증가함을 볼 수 있었다. 그러나 플라즈마 에너지 효율은 주파수가 높아짐에 따라 점점 커지다 작아지는 경향을 볼 수 있었다. 에너지 전달 효율의 변화는 정합회로의 표피효과(Skin effect)에 기인하며 플라즈마 밀도의 변화는 이온의 에너지 손실에 기인한다.

  • PDF

A Study on the High Speed Breaking of Parallel Arcing (병렬아크의 고속 차단에 관한 연구)

  • Kim, Il-Kwon;Ji, Hong-Keun;Kim, Sung-Uk;Park, Dae-Won;Kil, Gyung-Suk
    • Proceedings of the KSR Conference
    • /
    • 2008.06a
    • /
    • pp.327-331
    • /
    • 2008
  • This paper dealt with high speed breaking method to parallel arcing in low-voltage systems. The proposed high speed breaking circuit consists of a Rogowski coil and an integrator, and operates with an earth leakage circuit breaker (ELCB). A parallel arcing state was simulated by a short circuit using stripped wires. In this test, we analyzed tripping characteristics of the circuit breaker by the length of wires from 5m to 30m. From the experimental results, we confirmed that the proposed method can break the parallel arcing within a few millisecond.

  • PDF

Development of a Ubiquitous Sensor for Monitoring Insulators and Arresters (애자/피뢰기 모니터링을 위한 유비쿼터스 센서 개발)

  • Kil, G.S.;Shin, G.C.;Park, J.K.;Sim, J.W.;Song, J.Y.
    • Proceedings of the KSR Conference
    • /
    • 2006.11b
    • /
    • pp.736-741
    • /
    • 2006
  • In this study, a ubiquitous sensor for condition monitoring of insulators and lightning arresters installed in power distribution lines and electric traction vehicles is presented. The sensor consists of two parts; a leakage current measurement and a lightning surge detection. Measured data are transmitted to a supervisory computer through ZigBee protocol based on IEEE 802.15.4. To detect leakage current, a window type Mn-ZCT is used and a low-noise amplifier with a gain of 60dB is designed, and this can measure leakage current in ranges of $100{\mu}A{\sim}5mA$. A sample-hold(S/H) and a Rogowski coil are injected to analyze the magnitude of surge current in ranges from 500A to 10kA with $8/20{\mu}s$-waveform.

  • PDF

The Analysis for the characteristics about the Digital Control CT & PT (디지털 제어형 CT 및 PT에 관한 특성 분석)

  • Shin, Jung-Eun;Kim, Jae-Chul;Song, Seung-Youp;Kwon, Young-Mok;Kim, On-Suk
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2004.05a
    • /
    • pp.456-459
    • /
    • 2004
  • Generally, instrument transformer of the core type have been used for measuring current. Because instrument transformer has defects, electronic instrument was appeared. Electronic instrument has many merit-linearity, small size, low cost, etc. Rogowski coil is typical electronic CT and R-divider is typical electronic VT. This paper is introduced a basic concept and theory of electronic current transformer, electronic voltage transformer.

  • PDF

The Development of Electronic Transformer(CT/PT) for Intelligent GIS Based on IEC 60044 (IEC 60044 기반 Intelligent GIS용 전자식 변성기 개발)

  • Kim, M.S.;Jung, J.R.;Kim, J.B.;Song, W.P.
    • Proceedings of the KIEE Conference
    • /
    • 2005.07c
    • /
    • pp.2262-2264
    • /
    • 2005
  • 지금까지 변전소나 개폐소에서 전류, 전압을 계측하는 수단으로서 주로 철심과 권선으로 구성되어진 변류기(CT), 계기용 변압기(PT, PD)가 사용되어져 왔다. 최근, 2차측의 계측기나 보호 Relay의 Digital화가 진전되어 또한 이것을 Digital Network으로 총합한 Intelligent 변전소의 구축이 검토되어지고 있으며, Digital Network에 대응한 변성기 관련규격인 IEC 60044가 근래 제정되어짐에 따라 이에 적합한 전자식 변성기가 요구되어지고 있다. 상기와 같은 요구로 인해 당사에서는 IEC 60044를 기반으로 한 전자식변성기 Layout을 구성하였으며, CT는 검출부에 Rogowski Coil을 적용하며 그 후단에 적분기를 설치하였으며, VD는 검출부에 중간 전극을 이용해서 분압하는 방식인 Capacitive Voltage Divider를 사용하고 증폭기를 삽입하여, 각각 요구되는 전압 신호를 얻었다. 이러한 신형 CT/VD의 적용으로 종래의 CT/PT가 차지하는 공간이 필요없게 되어 컴팩트한 GIS의 구조가 가능하게 되어 있다.

  • PDF

Development of Current and Voltage Sensors for Distribution switchgears (로고스키 코일과 저항 분압기 원리를 이용한 배전급 전류/전압 센서 개발)

  • Choe, W.J.;Sohn, J.M.;Lee, B.W.;Oh, I.S.
    • Proceedings of the KIEE Conference
    • /
    • 2003.07b
    • /
    • pp.888-890
    • /
    • 2003
  • In the distribution networks, it is required to develop compact and smart current and voltage sensors for compact and digital switchgears. The sensor developed newly adopt the priciple of rogowski coil for current sensing and resistive voltage divider for voltage sensing. The sensing characteristics and reliabilities were improved compared to conventional ones. In the near future, these voltage and current sensing apparatus will be widely used with electronic protection units for the distribution switchgear.

  • PDF

Construction of 154kV Intelligent Substation for Verification Test (154kV급 실증시험용 인텔리전트 변전소 구축)

  • Chung, Y.H.;Kim, J.B.;Lee, H.S.;Choi, I.H.;Lee, D.I
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.661-662
    • /
    • 2007
  • We have carried out the construction of the 154kV intelligent substation with KEPRI. The intelligent substation is built in Gochang testing facility of KEPCO and consists of electronic instruments for GIS(gas insulated switchgear), digital control panel, remote monitoring and diagnosis system, and digital relay system. Rogowski coil type CT(RCT) and capacitive voltage divider(CVD) are introduced compared with the instrument transformer of conventional type. Digital control panel(DCP) replaces the LCP(local control panel) which is drived for mechanical operation. For the monitoring of the condition of GIS and TR, various sensors are used. In this paper, we mention the synopsis and report the progress state of project.

  • PDF

A Study on the Development of Digital CT/VD for GIS (가스절연개폐장치(GIS)용 디지털 CT/VD 개발에 관한 연구)

  • Kim, M.S.;Kim, J.B.;Song, W.P.;Kim, D.S.
    • Proceedings of the KIEE Conference
    • /
    • 2002.11a
    • /
    • pp.22-24
    • /
    • 2002
  • 지금까지 변전소나 개폐소에서 전류, 전압을 계측하는 수단으로서 주로 철심과 권선으로 구성되어진 변류기(CT), 계기용 변압기(PT, PD)가 사용되어져 왔다. 최근, 2차측의 계측기나 보호 Relay의 Digital화가 진전되어, 또한 이것을 Digital Network으로 총합한 Intelligent 변전소의 구축이 검토되어짐에 따라, Digital Network에 대응한 신형 CT, VD가 요구되어지고 있다. 상기와 같은 요구로 인해 당사에서는 CT는 검출부에 Rogowski Coil을 적용하며 그 후단에 적분기를 설치하였으며, VD는 검출부에 중간 전극을 이용해서 분압하는 방식인 Capacitive Voltage Divider를 사용하고 증폭기를 삽입하여, 각각 요구되는 전압 신호를 얻었다. 이러한 신형 CT/VD의 적용으로 종래의 CT/PT가 차지하는 공간이 필요 없게 되어 컴팩트한 GIS의 구조가 가능하게 되어 있다.

  • PDF