• Title/Summary/Keyword: Rod float

Search Result 8, Processing Time 0.023 seconds

Analysis of Field Observations on Characteristics of Stage-Discharge Relationshiup for Yangsan River (양산천 수위-유량관계 특성에 관한 현장관측 분석)

  • 이용희;이상배
    • Journal of Korean Port Research
    • /
    • v.14 no.1
    • /
    • pp.107-114
    • /
    • 2000
  • Derivation of stage-discharge relationship and characteristics for Yangsan river is presented in this paper. This research has been conducted as the second one after the first trial in 1997. The determination of discharge at a Yangsan river gauging was best made by measuring the flow velocities with a current meter and rod float. The rating curve obtained through 52 stage-discharge measurements on Yangsan river basin in 1999 is represented by Q=15.3540-140.6076H+182.44372H$^2$, which is discovered to be most excellent among other curves in reliability analysis. The observed stage-discharge data for Yangsan river was tested by HEC-RAS program, and reproduction of discharge by the induced curve was investigated and compared with the computational results. The rating curve of Yangsan river shows characteristics of Yangsan river more accurately compared with those separated in terms of water levels.

  • PDF

Inter-comparison of Accuracy of Discharge Measurement Methods - A Case Study Performed in the Dalcheon River Downstream of the Goesan Dam- (유량측정 방법의 정확도 분석 -괴산댐 하류 달천 적용 사례를 중심으로-)

  • Lee, Chan-Joo;Kim, Dong-Gu;Kwon, Sung-Il;Kim, Won
    • Journal of Korea Water Resources Association
    • /
    • v.43 no.12
    • /
    • pp.1039-1050
    • /
    • 2010
  • Relative accuracy of six discharge measurement methods-velocity-area method, rod-float method, ADCP moving-vessel method, ADCP fixed-vessel method, electromagnetic wave surface velocimeter (EWSV), LSPIV- is evaluated by comparing discharges measured by them with dam released discharges. Data from 39 times of concurrent discharge measurement campaigns are analyzed. Except the rod-float method, measured discharges show absolute errors less than 6.2% with dam discharges. When the four methods is evaluated by being compared with discharges measured with the conventional velocity-area method, discharges with electromagnetic wave surface velocimetry shows 7.35% of absolute errors and other three methods shows absolute errors less than 6%. The rod-float method, which shows large discrepancy compared with dam and velocity-area method, need complementary verification.

A Basic Study of Stage-discharge Rating Stabilization at the Ssang-chi Gauging Station (쌍치 수위관측소의 수위-유량관계곡선 안정화를 위한 기초 연구)

  • Lee, Jeong-Ju;Kwon, Hyun-Han
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.30 no.1B
    • /
    • pp.81-87
    • /
    • 2010
  • On the SSang-chi gauging station, the discharge had been measured by the rod float method for the past twelve years. However the shifts of the rating curves are too big to be accepted. The major factors of rating curve variation were reviewed for shift analysis. To estimate the discharge measured by rod float method, two cross sections and their stages are generally required. But, the rating curves had been derived only with the observed depth of gauging station since the cross sections were not available. To correct the errors, the reference rating curve was developed. In this study, the water surface slopes of the curve were simulated by RMA2 model. The historical rating curves were re-developed by the calculated discharges on the base of the water surfaces. The results show that the range of fluctuation decreased and rating curves in recent years are physically reasonable.

A Study on Characteristics of Stage-discharge Relationship for Yangsan River (양산천 수위-유량관계 특성에 관한 연구)

  • 이용희;이상배
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2000.04a
    • /
    • pp.91-98
    • /
    • 2000
  • Derivation of stage-discharge relationship and characteristics for Yangsan river is presented in this paper. This research has been conducted as the second one after the first trial of 1997. The determination of discharge at a Yangsan river gauging was best made by measuring the flow velocities with a current meter and rod float. The rating curve obtained through 52 stage-discharge measurements on Yangsan river basin in 1999 is represented by Q=15.3540-140.6076H+182.44372$H^2$, which is discovered to be most excellent among other curves in reliability analysis. The capability of the observed stage-discharge data for Yangsan river was tested by HEC-RAS program, and its capability to reproduce discharge was investigated and compared with the computational results. Rating curve stability is determined on the basis of deviations in the stage-discharge relationship, utilization of specific gauge, and absolute differences between sequential stream flow measurements and an analysis residuals. Therefore it seems necessary to research method to obtain rating curve in a rigorous and accurate manner.

  • PDF

A Study on a process for signal to detect the continuous position of liquid (연속 수위 검출 신호 처리에 대한 연구)

  • Bae, Sang-June;Chae, Su-Hyung
    • Proceedings of the KIEE Conference
    • /
    • 2002.06a
    • /
    • pp.178-183
    • /
    • 2002
  • In this paper, the capacitive sensor which can detect the continuous position of liquid is proposed. The proposed sensor make up copper rod's defect which are oxidized in liquid and float switch's defect which are tired of continuous movements. This sensor make use of what capacitance is varying due to quantity and kind of dielectric in the plane gap. The operating principle of the sensor and the amplifying methode of detecting signal and the methode of apply in computer control system are presented in this paper.

  • PDF

Horary System of the Early Chosen and the King Sejong′s Striking Clepsydra : (1) Water-Clocks (조선초기의 시제와 세종의 자격루:(1) 물시계)

  • 남문현;한득영
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1996.11a
    • /
    • pp.697-701
    • /
    • 1996
  • King Sejong's Striking water-clock which brought in use on the first of July in 1434 was mainly composed of timekeeping and time announcing parts signalling twelve double-hours, and five night-watches and night-watch-divisions automatically by means of ball-operating jackworks. The clock was arranged with dual timekeeping system, the one for a full day(twelve double-hours) and the other for five night-watches achieving twelve double-hours and one-hundred interval horary systems. The vessels were arrayed in inflow-type water-clock, a large reservoir on the highest story, a constant-level tank for supplying water to the measuring vessel evenly in the middle, and the lowest tank to receive water from the above constant-level tank. An indicator-rod on the float was raised upwards depending on the water-level increase to show timing scales and also to release small bronze balls from the ball-rack mechanisms implanted on the measuring vessel to signal timing intervals.

  • PDF

A Field Tracer Experiment by Using a Radioisotope near the Offshore (동위원소를 이용한 연안역 현장실험)

  • Kim, Ki Chul;Park, Geon Hyeong;Lee, Jin Yong;Jung, Sung Hee;Min, Byung Il;Suh, Kyung Suk
    • Journal of Radiation Industry
    • /
    • v.6 no.1
    • /
    • pp.41-47
    • /
    • 2012
  • A field tracer experiment using a radioisotope was conducted to analyze the transport and dispersion characteristics of pollutants in the coastal area near a Wolsung. A rod float including GPS was released to track the paths of radioisotope. NaI detector was installed to measure the released radioisotope from the boat, and measurements were performed with the real time. The measured tracer data by a field experiment can be used as the basic data for understanding the transport characteristics of pollutants and verifying numerical models near the offshore.

A STUDY ON THE JUJEON OF AUTOMATIC CLEPSYDRA IN EARLY JOSEON DYNASTY (조선 전기 자동물시계의 주전(籌箭) 연구)

  • YUN, YONG-HYUN;KIM, SANG HYUK;MIHN, BYEONG-HEE;OH, KYONG TAEK
    • Publications of The Korean Astronomical Society
    • /
    • v.36 no.3
    • /
    • pp.65-78
    • /
    • 2021
  • Jagyeokru, an automatic striking water clock described in the Sejong Sillok (Veritable Records of King Sejong) is essentially composed of a water quantity control device and a time-signal device, with the former controlling the amount or the flow rate of water and the latter automatically informing the time based on the former. What connects these two parts is a signal generating device or a power transmission device called the 'Jujeon' system, which includes a copper rod on the float and ball-racked scheduled plates. The copper products excavated under Gongpyeong-dong in Seoul include a lot of broken plate pieces and cylinder-like devices. If some plate pieces are put together, a large square plate with circular holes located in a zigzag can be completed, and at the upper right of it is carved 'the first scheduled plate (一箭).' Cylinder-like devices generally 3.8 cm in diameter are able to release a ball, and have a ginkgo leaf-like screen fixed on the inner axis and a bird-shaped hook of which the leg fixes another axis and the beak attaches to the leaf side. The lateral view of this cylinder-like device appears like a trapezoid and mounts an iron ball. The function of releasing a ball agrees with the description of Borugak Pavilion, where Jagyeokru was installed, written by Kim Don (1385 ~ 1440). The other accounts of Borugak Pavilion's and Heumgyeonggak Pavilion's water clocks describe these copper plates and ball releasing devices as the 'Jujeon' system. According to the description of Borugak Pavilion, a square wooden column has copper plates on the left and right sides the same height as the column, and the left copper plate has 12 drilled holes to keep the time of a 12 double-hours. Meanwhile, the right plate has 25 holes which represent seasonal night 5-hours (Kyeong) and their 5-subhours (Jeom), not 12 hours. There are 11 scheduled plates for seasonal night 5-hours made with copper, which are made to be attached or detached as the season. In accordance with Nujutongui (manual for the operation of the yardstick for the clepsydra), the first scheduled plate for the night is used from the winter solstice (冬至) to 2 days after Daehan (大寒), and from 4 days before Soseol (小雪) to a day before the winter solstice. Besides the first scheduled plate, we confirm discovering a third scheduled plate and a sixth scheduled plate among the excavated copper materials based on the spacing between holes. On the other hand, the width of the scheduled plate is different for these artifacts, measured as 144 mm compared to the description of the Borugak Pavilion, which is recorded as 51 mm. From this perspective, they may be the scheduled plates for the Heumgyeonggak Ongru made in 1438 (or 1554) or for the new Fortress Pavilion installed in Changdeokgung palace completed in 1536 (the 31st year of the reign of King Jungjong) in the early Joseon dynasty. This study presents the concept of the scheduled plates described in the literature, including their new operating mechanism. In addition, a detailed model of 11 scheduled plates is designed from the records and on the excavated relics. It is expected that this study will aid in efforts to restore and reconstruct the automatic water clocks of the early Joseon dynasty.