• Title/Summary/Keyword: Robotic-assisted surgery

Search Result 48, Processing Time 0.029 seconds

Robotic Intraoperative Tracheobronchial Repair during Minimally Invasive 3-Stage Esophagectomy

  • Marano, Alessandra;Palagi, Silvia;Pellegrino, Luca;Borghi, Felice
    • Journal of Chest Surgery
    • /
    • v.54 no.2
    • /
    • pp.154-157
    • /
    • 2021
  • Tracheobronchial injury (TBI) is an uncommon but potentially fatal event. Iatrogenic lesions during bronchoscopy, endotracheal intubation, or thoracic surgery are considered the most common causes of TBI. When TBI is detected during surgery, concomitant surgical treatment is recommended. Herein we present a case of successful robotic primary repair of iatrogenic tracheal and left bronchial branch tears during a robot-assisted hybrid 3-stage esophagectomy after neoadjuvant chemoradiotherapy. A robotic approach can facilitate the repair of this injury while reducing both the potential risk of conversion to open surgery and the associated increased risk of postoperative respiratory complications.

$DaVinci^{TM}$ S robot-assisted esophagectomy in a 83-year-old patient with esophageal cancer (고령의 식도암 환자에서 다빈치 S 로봇을 이용한 식도 절제술)

  • Haam, Seok-Jin;Park, Seong-Yong;Paik, Hyo-Chae
    • Korean Journal of Bronchoesophagology
    • /
    • v.14 no.2
    • /
    • pp.53-56
    • /
    • 2008
  • The postoperative respiratory complications such as pneumonia and ARDS, are poor prognostic factors after esophagectomy in patients with esophageal cancer. To avoid these complications, there have been attempts to use minimally invasive approach. Recently introduced daVinciTM S surgical system is used in esophagectomy because of its advantages of minimal invasiveness, clear 3-dimensional imaging and precise handling of robotic arms. We report a 83-year-old esophageal cancer patient who underwent daVinciTMS robot-assisted esophagectomy, laparoscopic stomach mobilization followed by cervical esophagogastrostomy.

  • PDF

Preliminary study on application of augmented reality visualization in robotic thyroid surgery

  • Lee, Dongheon;Kong, Hyoun-Joong;Kim, Donguk;Yi, Jin Wook;Chai, Young Jun;Lee, Kyu Eun;Kim, Hee Chan
    • Annals of Surgical Treatment and Research
    • /
    • v.95 no.6
    • /
    • pp.297-302
    • /
    • 2018
  • Purpose: Increased robotic surgery is attended by increased reports of complications, largely due to limited operative view and lack of tactile sense. These kinds of obstacles, which seldom occur in open surgery, are challenging for beginner surgeons. To enhance robotic surgery safety, we created an augmented reality (AR) model of the organs around the thyroid glands, and tested the AR model applicability in robotic thyroidectomy. Methods: We created AR images of the thyroid gland, common carotid arteries, trachea, and esophagus using preoperative CT images of a thyroid carcinoma patient. For a preliminary test, we overlaid the AR images on a 3-dimensional printed model at five different angles and evaluated its accuracy using Dice similarity coefficient. We then overlaid the AR images on the real-time operative images during robotic thyroidectomy. Results: The Dice similarity coefficients ranged from 0.984 to 0.9908, and the mean of the five different angles was 0.987. During the entire process of robotic thyroidectomy, the AR images were successfully overlaid on the real-time operative images using manual registration. Conclusion: We successfully demonstrated the use of AR on the operative field during robotic thyroidectomy. Although there are currently limitations, the use of AR in robotic surgery will become more practical as the technology advances and may contribute to the enhancement of surgical safety.

Robot-Assisted Repair of Atrial Septal Defect: A Comparison of Beating and Non-Beating Heart Surgery

  • Yun, Taeyoung;Kim, Hakju;Sohn, Bongyeon;Chang, Hyoung Woo;Lim, Cheong;Park, Kay-Hyun
    • Journal of Chest Surgery
    • /
    • v.55 no.1
    • /
    • pp.55-60
    • /
    • 2022
  • Background: Robot-assisted repair of atrial septal defect (ASD) can be performed under either beating-heart or non-beating-heart conditions. However, the risk of cerebral air embolism (i.e., stroke) is a concern in the beating-heart approach. This study aimed to compare the outcomes of beating- and non-beating-heart approaches in robot-assisted ASD repair. Methods: From 2010 to 2019, a total of 45 patients (mean age, 43.4±14.6 years; range, 19-79 years) underwent ASD repair using the da Vinci robotic surgical system. Twenty-seven of these cases were performed on a beating heart (beating-heart group, n=27) and the other cases were performed on an arrested or fibrillating heart (non-beating-heart group, n=18). Cardiopulmonary bypass (CPB) was achieved via cannulation of the femoral vessels and the right internal jugular vein in all patients. Results: Complete ASD closure was verified using intraoperative transesophageal echocardiography in all patients. Conversion to open surgery was not performed in any cases, and there were no major complications. All patients recovered from anesthesia without any immediate postoperative neurologic symptoms. In a subgroup analysis of isolated ASD patch repair (beating-heart group: n=22 vs. non-beating-heart group: n=5), the operation time and CPB time were shorter in the beating-heart group (234±38 vs. 253±29 minutes, p=0.133 and 113±28 vs. 143±29 minutes, p=0.034, respectively). Conclusion: Robot-assisted ASD repair can be safely performed with the beating-heart approach. No additional risk in terms of cerebral embolism was found in the beating-heart group.

Robot-Assisted Free Flap in Head and Neck Reconstruction

  • Song, Han Gyeol;Yun, In Sik;Lee, Won Jai;Lew, Dae Hyun;Rah, Dong Kyun
    • Archives of Plastic Surgery
    • /
    • v.40 no.4
    • /
    • pp.353-358
    • /
    • 2013
  • Background Robots have allowed head and neck surgeons to extirpate oropharyngeal tumors safely without the need for lip-split incision or mandibulotomy. Using robots in oropharyngeal reconstruction is new but essential for oropharyngeal defects that result from robotic tumor excision. We report our experience with robotic free-flap reconstruction of head and neck defects to exemplify the necessity for robotic reconstruction. Methods We investigated head and neck cancer patients who underwent ablation surgery and free-flap reconstruction by robot. Between July 1, 2011 and March 31, 2012, 5 cases were performed and patient demographics, location of tumor, pathologic stage, reconstruction methods, flap size, recipient vessel, necessary pedicle length, and operation time were investigated. Results Among five free-flap reconstructions, four were radial forearm free flaps and one was an anterolateral thigh free-flap. Four flaps used the superior thyroid artery and one flap used a facial artery as the recipient vessel. The average pedicle length was 8.8 cm. Flap insetting and microanastomosis were achieved using a specially manufactured robotic instrument. The total operation time was 1,041.0 minutes (range, 814 to 1,132 minutes), and complications including flap necrosis, hematoma, and wound dehiscence did not occur. Conclusions This study demonstrates the clinically applicable use of robots in oropharyngeal reconstruction, especially using a free flap. A robot can assist the operator in insetting the flap at a deep portion of the oropharynx without the need to perform a traditional mandibulotomy. Robot-assisted reconstruction may substitute for existing surgical methods and is accepted as the most up-to-date method.

Esthetic neck dissection using an endoscope via retroauricular incision: a report of two cases

  • Kim, Jae-Young;Cho, Hoon;Cha, In-Ho;Nam, Woong
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.40 no.1
    • /
    • pp.27-31
    • /
    • 2014
  • Various surgical techniques, such as endoscopic surgery and robotic surgery, are developed to optimize the esthetic outcome even in operations for malignancy. A modified face-lift or retroauricular approach are used to minimize postoperative scarring. Recently, robot-assisted surgery is being done in various fields and considered as favorable treatment method by many surgeons. However its high cost is a nonnegligible fraction for many patients. On the other hand, endoscopic surgery, which is cheaper than robotic surgery, is minimally invasive with contentable neck dissection. Although it is a difficult technique for a beginner surgeon due to its limited operation view, we suppose it as an alternative method for robotic surgery. Herein, we report two cases of endoscopic neck dissection via retroauricular incision with a discussion regarding the pros and cons of endoscopic neck dissection.

Two Cases of Robot-Assisted Totally Minimally Invasive Esophagectomy with Colon Interposition for Gastroesophageal Junction Cancer: Surgical Considerations

  • Kinam Shin;In Ha Kim;Yun-Ho Jeon;Chung Sik Gong;Chan Wook Kim;Yong-Hee Kim
    • Journal of Chest Surgery
    • /
    • v.57 no.3
    • /
    • pp.323-327
    • /
    • 2024
  • This case report presents 2 patients with gastroesophageal junction cancer who both underwent totally minimally invasive esophagectomy with colon interposition. Patients 1 and 2, who were 43-year-old and 78-year-old men, respectively, had distinct clinical presentations and medical histories. Patient 1 underwent minimally invasive robotic esophagectomy with a laparoscopic total gastrectomy, colonic conduit preparation, and intrathoracic esophago-colono-jejunostomy. Patient 2 underwent completely robotic total gastrectomy, colon conduit preparation, and intrathoracic esophago-colono-jejunostomy. The primary challenge in colon interposition is assessing colon vascularity and ensuring an adequate conduit length, which is critical for successful anastomosis. In both cases, we used indocyanine green fluorescence angiography to evaluate vascularity. Determining the appropriate conduit is challenging; therefore, it is crucial to ensure a slightly longer conduit during reconstruction. Because totally minimally invasive colon interposition can reduce postoperative pain and enhance recovery, this surgical technique is feasible and beneficial.

Robotically Assisted Mitral Valve Repair as the Treatment of Choice for Patients with Difficult Anatomies

  • Russo, Marco;Ouda, Hamed;Andreas, Martin;Taramasso, Maurizio;Benussi, Stefano;Maisano, Francesco;Weber, Alberto
    • Journal of Chest Surgery
    • /
    • v.52 no.1
    • /
    • pp.55-57
    • /
    • 2019
  • Robotically assisted mitral valve repair has proven its efficacy during the last decade. The most suitable approach for patients with difficult anatomies, such as morbid obesity, sternal deformities, cardiac rotation, or vascular anomalies, represents a current challenge in cardiac surgery. Herein, we present the case of a 71-year-old patient affected by severe degenerative mitral valve regurgitation with pectus excavatum and a right aortic arch with an anomalous course of the left subclavian artery who was successfully treated using a Da Vinci-assisted approach.

Use of Magnetic Resonance Imaging for Evaluating Residual Breast Tissue After Robotic-Assisted Nipple-Sparing Mastectomy in Women With Early Breast Cancer

  • Wen-Pei Wu;Hung-Wen Lai;Chiung-Ying Liao;Joseph Lin;Hsin-I Huang;Shou-Tung Chen;Chen-Te Chou;Dar-Ren Chen
    • Korean Journal of Radiology
    • /
    • v.24 no.7
    • /
    • pp.640-646
    • /
    • 2023
  • Objective: Prospective studies on postoperative residual breast tissue (RBT) after robotic-assisted nipple-sparing mastectomy (R-NSM) for breast cancer are limited. RBT presents an unknown risk of local recurrence or the development of new cancer after curative or risk-reducing mastectomies. This study investigated the technical feasibility of using magnetic resonance imaging (MRI) to evaluate RBT after R-NSM in women with breast cancer. Materials and Methods: In this prospective pilot study, 105 patients, who underwent R-NSM for breast cancer at Changhua Christian Hospital between March 2017 and May 2022, were subjected to postoperative breast MRI to evaluate the presence and location of RBT. The postoperative MRI scans of 43 patients (age, 47.8 ± 8.5 years), with existing preoperative MRI scans, were evaluated for the presence and location of RBT. In total, 54 R-NSM procedures were performed. In parallel, we reviewed the literature on RBT after nipple-sparing mastectomy, considering its prevalence. Results: RBT was detected in 7 (13.0%) of the 54 mastectomies (6 of the 48 therapeutic mastectomies and 1 of the 6 prophylactic mastectomies). The most common location for RBT was behind the nipple-areolar complex (5 of 7 [71.4%]). Another RBT was found in the upper inner quadrant (2 of 7 [28.6%]). Among the six patients who underwent RBT after therapeutic mastectomies, one patient developed a local recurrence of the skin flap. The other five patients with RBT after therapeutic mastectomies remained disease-free. Conclusion: R-NSM, a surgical innovation, does not seem to increase the prevalence of RBT, and breast MRI showed feasibility as a noninvasive imaging tool for evaluating the presence and location of RBT.

Development of Control and HMI for Safe Robot Assisted Minimally Invasive Surgery (최소침습수술용 로봇의 안전성을 위한 제어 및 HMI 개발)

  • Jung, Hoi-Ju;Song, Hyun-Jong;Park, Jang-Woo;Park, Shin-Suk
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.28 no.9
    • /
    • pp.1048-1053
    • /
    • 2011
  • Recently, robots have been used in surgical area. Robotic surgery in Minimally Invasive Surgery gives many advantages to surgeons and patients both. This study introduce a robotic assistant to improve the safety of telerobotic Minimally Invasive Surgical procedures. The master-slave system is applied to the telerobotic surgical system with the master arm, which control the system, and slave robot which operates the surgery on the patient body. By using a 3-DOF master arm, the surgeon can control the 6-DOF surgical robot under the constraint of fulcrum point. This paper explains the telerobotic surgical system and confirms the system with the precision of the robot control related to the fulcrum point to enhance the safety.