• Title/Summary/Keyword: Robot Leg

Search Result 246, Processing Time 0.021 seconds

Analysis Torque Characteristics and Improved Efficiency of Permanent Magnet Multi-D.O.F. Spherical Motor (영구자석형 다자유도 구형전동기의 토크특성 분석과 효율 향상에 대한 연구)

  • Lee, Ho-Joon;Kim, Yong;Jang, Ik-Sang;Park, Hyun-Jong;Kang, Dong-Woo;Won, Sung-Hong;Lee, Ju
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.1
    • /
    • pp.57-63
    • /
    • 2012
  • A surfaced permanent magnet spherical motor is capable of operating as three degree of freedom that used for the joints of the robot's arm, leg, and eyes. Ongoing research like new concept is essential part of motor field, it will make a great contribution in the future the overall portion of the motor, is becoming expected. The author analysis torque characteristics in spherical motor with state of rotating and positioning. And future design direction is smaller motors with equivalent or higher output. Solutions as torque and efficiency improvements are selecting the core with special processing type like powder metallurgy materials. Their special characteristic is high permeability and low eddy current losses at high speed, so improved the torque and efficiency.

Constant DC Capacitor Voltage Control based Strategy for Active Load Balancer in Three-phase Four-wire Distribution Systems

  • Win, Tint Soe;Tanaka, Toshihiko;Hiraki, Eiji;Okamoto, Masayuki;Lee, Seong Ryong
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • v.3 no.2
    • /
    • pp.176-183
    • /
    • 2014
  • Three-phase four-wire distribution systems are used for both three-phase three-wire loads and single-phase two-wire consumer appliances in South Korea, Myanmar and other countries. Unbalanced load conditions frequently occur in these distribution systems. These unbalanced load conditions cause unbalanced voltages for three-phase and single-phase loads, and increase the loss in the distribution transformer. In this paper, we propose constant DC capacitor voltage control based strategy for the active load balancer (ALB) in the three-phase four-wire distribution systems. Constant DC capacitor voltage control is always used in active power line conditioners. The proposed control strategy does not require any computation blocks of the active and reactive currents on the distribution systems. Balanced source-side currents with a unity power factor are obtained without any calculation block of the unbalanced active and reactive components on the load side. The basic principle of the constant DC capacitor voltage control based strategy for the ALB is discussed in detail and then confirmed by both digital computer simulations using PSIM software and prototype experimental model. Simulation and experimental results demonstrate that the proposed control strategy for the ALB can balance the source currents with a unity power factor in the three-phase four-wire distribution systems.

Camera Self-Calibration from Two Ellipse Contours in Pipes

  • Jeong, Kyung-Min;Seo, Yong-Chil;Choi, Young-Soo;Cho, Jai-Wan;Lee, Sung-Uk;Kim, Seung-Ho
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.1516-1519
    • /
    • 2004
  • A tele-operated robot should be used to maintain and inspect nuclear power plants to reduce the radiation exposure to the human operators. During an overhaul of the nuclear power plants in Korea, a ROV(Remotely Operated Vehicle) may enter a cold-leg connected to the reactor to examine the state of the thermal sleeve and it's position in the safety injection nozzle. To measure the positions of the thermal sleeve or scratches from the video images captured during the examination, the camera parameters should be identified. However, the focal length of the CCD camera could be increased to a close up of the target and the aspect ratio and the center of the image could also be varied with capturing devices. So, it is desired to self-calibrated the intrinsic parameters of the camera and capturing device with the video images captured during the examination. In the video image of the safety injection nozzle, two or more circular grooves around the nozzle are shown as ellipse contours. In this paper, we propose a camera self-calibration method using a single image containing two circular grooves which are the greatest circles of the cylindrical nozzle whose radius and distance are known.

  • PDF

A Study on Particular Abnormal Gait Using Accelerometer and Gyro Sensor (가속도센서와 각속도센서를 이용한 특정 비정상보행에 관한 연구)

  • Heo, Geun-Sub;Yang, Seung-Han;Lee, Sang-Ryong;Lee, Jong-Gyu;Lee, Choon-Young
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.29 no.11
    • /
    • pp.1199-1206
    • /
    • 2012
  • Recently, technologies to help the elderly or disabled people who have difficulty in walking are being developed. In order to develop these technologies, it is necessary to construct a system that gathers the gait data of people and analysis of these data is also important. In this research, we constructed the development of sensor system which consists of pressure sensor, three-axis accelerometer and two-axis gyro sensor. We used k-means clustering algorithm to classify the data for characterization, and then calculated the symmetry index with histogram which was produced from each cluster. We collected gait data from sensors attached on two subjects. The experiment was conducted for two kinds of gait status. One is walking with normal gait; the other is walking with abnormal gait (abnormal gait means that the subject walks by dragging the right leg intentionally). With the result from the analysis of acceleration component, we were able to confirm that the analysis technique of this data could be used to determine gait symmetry. In addition, by adding gyro components in the analysis, we could find that the symmetry index was appropriate to express symmetry better.

Smart Glasses Cannula Guide System Development for Interventional Cardiology Procedures (중재적 심장 질환 시술을 위한 스마트 글래스 삽입관 가이드 시스템 개발)

  • Jang, Ik Gyu;Heo, Yeong Jun;Jeon, Geum Sang;Choi, Jaesoon
    • Journal of Biomedical Engineering Research
    • /
    • v.41 no.5
    • /
    • pp.173-178
    • /
    • 2020
  • Remote control intervention surgery robotic system improves treatment effect on cardiovascular patients and reduces X-ray exposure. However, at the time of the first procedure, CT (computerized tomography) and other ultrasound diagnostic equipment should be used because the operator must insert the cannula directly into the patient's leg. Improvements to this have been un-met-needs of hospitals. In this paper, we developed a system that can insert the cannula intuitively and quickly by displaying blood vessels at a glance through the system using smart wearable glasses. The core development method is as follows. In order to project augmented reality onto the surgical image, CT scan angiography image is extracted and processed. In the process, three CT-Markers are used to create a coordinate system of blood vessel images. Additionally, a reference marker is photographed on a single camera to obtain a camera coordinate system. Since the CT marker and the reference marker are in the same position, 3D registration is performed. In the text, a detailed explanation will be given.

Kinematic and dynamic analysis of a spherical three degree of freedom joint rehabilitation exercise equipment (3자유도 구형관절 재활운동기기의 기구학 및 동역학 해석)

  • Kim, Seon-Pil
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.14 no.4
    • /
    • pp.16-29
    • /
    • 2009
  • This paper investigates the kinematic and dynamic analysis of a spherical three degree of freedom parallel joint module, which is used in the exercise equipment for balance and leg-strength improvement of aged people. The joint module has three dyads which consist of two links and three revolute joints, and their all joints intersect at the global point located at the module's center. The paper shows the explicit mathematical procedure for deriving the closed form solutions in the inverse and forward position analysis of this parallel joint module. In velocity and acceleration analysis, we derived relations for joint velocities and accelerations of dyads and rotational velocity and acceleration of the top plate. For applying this module to rehabilitation exercise, we determined the dynamic model of the Korean males in their 50s and examined the model's results by dynamic model simulation.