• Title/Summary/Keyword: Robin

Search Result 513, Processing Time 0.03 seconds

Round Robin Test for Reliability Evaluation of Ultrasonic Thickness Measurement Results in Nuclear Power Plant Pipelines (원전감육배관 UT 두께측정 결과의 신뢰도 평가를 위한 다자비교시험)

  • Lee, Seung-Joon;Yi, Won-Geun;Lee, Joon-Hyun;Lee, Sung-Ho
    • Proceedings of the KSME Conference
    • /
    • 2007.05a
    • /
    • pp.1702-1707
    • /
    • 2007
  • The reduction of pipe-thickness induced by flow accelerated corrosion (FAC) is one of the most serious problems on the maintenance of piping system in nuclear power plants (NNP). If the thickness of a pipe component is reduced below the critical level, it cannot sustain pressure and consequently results in leakage or rupture. For this reason, wall thinning by FAC has been inspected in secondary side piping systems in NPPs. In this research Round Robin Test (RRT) was conducted to verify confidence of wall thinning measurement system in NPP. 12 inspectors from 3 companies participated and 23 specimens were used according to standard practice in RRT. The gage R&R analysis was introduced in regard to repeatability and reproducibility that are affected to measurement system errors. Confidence intervals of thickness measurement system were obtained.

  • PDF

Packet Scheduling with QoS and Fairness for Downlink Traffic in WiMAX Networks

  • Nie, Wei;Wang, Houjun;Park, Jong-Hyuk
    • Journal of Information Processing Systems
    • /
    • v.7 no.2
    • /
    • pp.261-270
    • /
    • 2011
  • The IEEE 802.16 standard is supposed to provide a wide-range broadband wireless service, but it leaves the implementation of the wireless resource scheduler as an open issue. We have studied the scheduling problem and propose a two level scheduling (TLS) scheme with support for quality of service and fairness guarantees for downlink traffic in a WiMAX network. A central controller Base Station has a number of users, and each mobile subscriber station has different channel conditions. The same mobile subscriber station may have different service requirements at different times in the WiMAX network. Based on OPNET simulation, the results show our scheduling algorithm can increase the network throughput, maintain relative fairness, and lower delay over the round robin and weighted round robin algorithms.

A Modified Dynamic Weighted Round Robin Cell Scheduling Algorithm

  • Kwak, Ji-Young;Nam, Ji-Seung;Kim, Do-Hyun
    • ETRI Journal
    • /
    • v.24 no.5
    • /
    • pp.360-372
    • /
    • 2002
  • In this paper, we propose the modified dynamic weighted round robin (MDWRR) cell scheduling algorithm, which guarantees the delay property of real-time traffic and also efficiently transmits non-real-time traffic. The proposed scheduling algorithm is a variation of the dynamic weighted round robin (DWRR) algorithm and guarantees the delay property of real-time traffic by adding a cell transmission procedure based on delay priority. It also uses a threshold to prevent the cell loss of non-real-time traffic that is due to the cell transmission procedure based on delay priority. Though the MDWRR scheduling algorithm may be more complex than the conventional DWRR scheme, considering delay priority minimizes cell delay and decreases the required size of the temporary buffer. The results of our performance study show that the proposed scheduling algorithm has better performance than the conventional DWRR scheme because of the delay guarantee of real-time traffic.

  • PDF

A comparison of predicted VLE of LNG mixtures containing $H_2S$ by use of Cubic and Noncubic EOS ($H_2S$를 포함하는 LNG 혼합물에 대한 Cubic과 Noncubic 상태방정식의 예측 비교)

  • Choi Eunjoo;Lee Taejong
    • Journal of the Korean Institute of Gas
    • /
    • v.4 no.4 s.12
    • /
    • pp.1-5
    • /
    • 2000
  • Cubic and non-cubic equations of state are used to calculate the vapor-liquid equilibrium(VLE) compositions for liquified natural gas(LNG) containing hydrogen sulfide. Modified Benedict-Web-Robin EOS is chosen as a non-cubic equation of state while Peng-Robinson, Soave-Redlich-Kwong EOS are used for a cubic EOS. Modified Benedict-Web-Robin EOS. showed better predictability than the cubic EOS used for the systems $H_2S/CH_4,\;H_2S/iC_4H_{10},\;H_2S/N_2$. specially for liquid composition.

  • PDF

Analysis on the Results of the Rockwell Hardness Round Robin Test (로크웰 경도도 순회 비교측정 결과에 대한 분석)

  • Bahng, G.W.;Tak, N.H.
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.14 no.5
    • /
    • pp.275-281
    • /
    • 2001
  • To improve the reliability of hardness test results, Rockwell hardness round robin test was carried out for 10 laboratories. The test condition was the same with the ISO(International Standards Organization) standards. Korea Research Institute of Standards and Science(KRISS) supplied the hardness standard blocks and an indenter to laboratories for the measurement. The participating laboratories measured hardness of the specified areas on the blocks for 6 times with their own indenter as well as common indenter, respectively, and reported the results to KRISS. The result showed that quite large amount of the differences came from the indenter and it is necessary to change indenter with better quality for improved reliability in hardness measurement.

  • PDF

A Study on the Evaluation of Measurement Uncertainty for the National Calibration and Test Organizations (Liquid Flow) (국가교정검사기관(액체유량)의 측정불확도 평가 및 비교연구)

  • 임기원
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.12 no.11
    • /
    • pp.1012-1019
    • /
    • 2000
  • A proficiency test is one of programs which Korea Research Institute of Standards and Science(KRISS), as national metrology institute, is putting in operation for the mutual recognition arrangement. The Fluid Flow Group of KRISS evaluated the measurement capability for liquid flowmeter calibrator of the national calibration and test organizations. The uncertainty of national standard system was estimated in accordance with Guide to The Expression of Uncertainty in Measurement (ISO), and the turbine flowmeter, which was used for the round-robin test as a reference flowmeter, was characterized. The round-robin tests with the turbine flowmeter package were carried out in 1995 and 1999. The test results of the organizations and those of KRISS agreed within $\pm0.2$%. It is found thus that the organizations have the traceability of the national standard for liquid flow measurement.

  • PDF

Simultaneous Burst and Burst Control Packet Transmission Protocol for Optical Burst Switching Ring Networks

  • Park, Joon-Pyo;Lee, Man-Seop
    • ETRI Journal
    • /
    • v.29 no.1
    • /
    • pp.116-119
    • /
    • 2007
  • In this letter, we design a collision resolution protocol for optical burst switching ring networks to avoid burst collision. We define the offset time condition for no burst transmission collision and manage the free time list of nodes for no burst reception collision. In order to improve the throughput, we use a fiber delay line, void-filling, and void-compression. This protocol does not require any additional procedures for bandwidth reservation such as centralized assignment of bandwidth, lightpath setup of WDM ring networks, or token capturing for the burst transmission. The simulation results show that the proposed protocol can achieve high throughput while saving 70% of wavelengths when compared to round robin with random selection, round robin with persistent, and round robin with non-persistent with only destination delay.

  • PDF

Tongue-lip adhesion in Pierre Robin sequence

  • Kumar, K.S. Krishna;Vylopilli, Suresh;Sivadasan, Anand;Pati, Ajit Kumar;Narayanan, Saju;Nair, Santhy Mohanachandran
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.42 no.1
    • /
    • pp.47-50
    • /
    • 2016
  • Patients with Pierre Robin sequence exhibit varying degrees of airway obstruction and feeding difficulty. In some patients, airway obstruction may be profound, warranting surgical intervention to maintain a patent airway. The purpose of this article is to highlight the advantages of the tongue-lip adhesion procedure for the management of airway obstruction in such patients compared to the currently available options.

Round-robin Test on AC Losses in a Technical High-Tc Superconducting Tape (실용고온초전도테이프의 교류손실에 대한 Round-robin테스트)

  • 류경우;최병주;황시돌
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.53 no.7
    • /
    • pp.437-443
    • /
    • 2004
  • In this work the AC loss measurement setup based on an iron core background magnet, not used in a conventional one, has been successfully developed. To prove its validity, a round-robin test for the same Bi-2223 tape sample among three institutes has been done. The results show that the self-field and magnetization losses from the developed setup well agree with the losses measured at two other institutes of Korea Basic Science Institute and Yokohama National University. The measured magnetization losses for parallel or perpendicular fields can be well predicted from the slab model or the strip model for a filamentary region. However the magnetization losses for longitudinal fields can be rather predicted by the slab model for a decoupled filament. The self-field losses are well explained by the Norris ellipse model.

Round-robin Test Results of AC Losses in a Practical Bi-2223 Tape (Bi-2223테이프의 교류손실에 관한 round-robin테스트 결과)

  • Kim, Hyun-Jun;Ryu, Hyung-Woo;Choi, Byoung-Ju
    • Proceedings of the KIEE Conference
    • /
    • 2003.07b
    • /
    • pp.780-782
    • /
    • 2003
  • 60 Hz의 전력분야에 고온초전도체를 적용 하는데 있어 가장 큰 장애요소인 교류손실에 대한 연구의 일환으로서 한 일간의 상이한 시험방법 및 장치에 대한 신뢰성과 정밀도를 상호 확인하기 위해 동일한 샘플 및 동일 시험조건으로 양측에서 round-robin테스트를 하였다. 그 주요 결과는 양측에서 측정한 자화손실은 시험 방법 및 장치의 상이함에도 불구하고 비교적 잘 일치하였다. 이는 자화손실 측정 시, 금기사항으로 되어있는 철심자석의 사용이 문제가 되지 않음을 의미하며, 이는 다시 기존 자화손실 시험장치의 공심자석 및 자석용 전원 설비가 대단히 소형화될 수 있음을 의미한다.

  • PDF