• 제목/요약/키워드: Road sprinkler

검색결과 6건 처리시간 0.019초

2023년 여름철 폭염 집중관측을 통한 서울 도심환경 조건에 따른 기온 및 노면 온도의 변화 특성 (Characteristics of Changes in Air and Road Temperatures Induced by Environmental Conditions in the Urban Region of Seoul Through an Intensive Observing Period (IOP) of Heatwaves in the Summer of 2023)

  • 나성준;한상대;김제원;박문수;김백조
    • 한국환경과학회지
    • /
    • 제33권1호
    • /
    • pp.75-85
    • /
    • 2024
  • An intensive observing period (IOP) of heatwaves in the urban region of Seoul in the summer of 2023 was carried out to understand the changes in air temperature and road temperature induced by environmental conditions. The temperature observed at eight points with different urban environmental conditions was compared with the temperature by the KMA/AWS to analyze the characteristics of change in air temperature by height and the change in road temperature according to environmental conditions and road sprinkler. The comparison of the average temperature observed in different urban environmental conditions with the temperature observed at KMA/AWS showed that the air temperature in asphalt and open space sites was 0.7 to 2.3℃ higher and that the one in bus stops was 0.9 to 2.3℃ higher. In terms of temperature deviations depending on residential type, the temperature in highly populated areas was about 0.1 to 0.8℃ higher than that of apartment complexes. In addition, regardless of the size of a park, the temperature in the park was lower than the temperature in dense housing areas and apartment complexes. In asphalt and residential areas, the road temperature was higher than the temperature at a height of 150 cm, Conversely, road temperature was lower than air temperature in a shaded shelter and large park. In addition, after spraying a surface road, the road temperature immediately dropped by about 3 to 4℃; however, after about 20 minutes, it rose again to the previous road temperature. This change in road temperature appeared only for the temperature of 30 cm height.

천장형 에어컨이 스프링클러 헤드 작동에 미치는 영향에 관한 연구 (A Study on the Effect of Ceiling Type Air Conditioner on Sprinkler Head Operation)

  • 이선영;윤명오;이영주;이준
    • 한국방재안전학회논문집
    • /
    • 제13권1호
    • /
    • pp.51-58
    • /
    • 2020
  • 본 연구는 천장형 에어컨의 기류가 스프링클러 헤드의 작동에 미치는 영향을 시뮬레이션 프로그램을 이용하여 분석한 내용이다. 시뮬레이션 공간은 10 m×7 m×3 m로, 화원의 크기는 0.8 m×0.8 m×0.6 m로 설정하였다. 에어컨에서 발생하는 찬 기류는 25℃로 설정하고 풍속을 10 ㎧, 8.5 ㎧, 7.5 ㎧의 3가지 CASE로 나누어 진행하였다. 시뮬레이션 결과 에어컨이 작동하지 않았을 때와 비교했을 때 모든 CASE에서 작동 지연이 발생하였으며 10 ㎧ 풍속의 경우는 10분경과시까지 스프링클러 헤드가 작동하지 않았다. 이와 같은 결과를 통해 에어컨이 작동하는 공간에서는 스프링클러 헤드가 작동하는 시간의 지연이 나타났음을 확인할 수 있었고 10 ㎧와 같은 강풍의 경우는 초기진화실패라는 최악의 결과를 예측할 수 있었다.

도시철도 터널 내 청소장치별 집진먼지 비교 분석 (A Comparative Analysis of Dust Particles Collected by Cleaning Equipments in Subway Tunnel)

  • 이영권;김일홍;조병기;김만화;박종헌
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2011년도 춘계학술대회 논문집
    • /
    • pp.1388-1398
    • /
    • 2011
  • Air pollution in subway tunnel is primarily caused from the wear of metallic materials. As undesirable substance, PM(Particulate Matter) can especially harm the health of passengers and workers as well as clog the main parts of rolling stock such as inverters. To improve the air quality in subway tunnel, SMRT(Seoul Metropolitan Rapid Transit Corporation) has developed anti-pollution devices such as Magnetic Dust Collector, Vacuum Cleaner For Rail Road and Particulate Removing Sprinkler Vehicle. Introducing these mechanical devices, this paper is mainly devoted to explaining the characteristics of collected dust according to the result of particle-size analysis and componential analysis.

  • PDF

터널 화재시 물분무노즐에 의해 형성되는 제연수막의 연기층 확산방지성능에 관한 실험적 연구 (Experimental Research on Effects of Water Sprayed Curtain On Anti-diffusion of Fire Gases in Case of Tunnel Fire)

  • 박형주;최영상;지남용
    • 한국건축시공학회지
    • /
    • 제4권1호
    • /
    • pp.97-103
    • /
    • 2004
  • In case of a fire in road or railway tunnel it is always necessary to keep the escape condition as good as possible. Most of the victims of major fires in tunnels are because they couldn't leave the tunnel in time and were trapped by smoke, or rescue teams couldn't reach the place of the accident due to low visibility and high temperature. In spring 2003 a comprehensive field experiment was undertaken in a large scaled tunnel in Youngin City to test the effectiveness of a new water spray curtain system, designed to the air qualify inside of a tunnel in case of fire during passenger's escape to safe routes, In order to control the smoke propagation, fixed water sprayed nozzles were used to make water curtain system, which can be installed or hanging water piping line below ceiling. The experiment was accompanied by an extensive measurement campaign in order to measure temperature dropping effect and flow conditions as well as CO concentration for various water sprayed curtains produced by sprinkler heads or water spray nozzle. Eventually comparison analysis were undertaken to investigate the performance of water curtains under fixed water pressure. Therefore most effective water curtain system was presented on the basis of water droplet size in long tunnel.

복층터널 화재대응을 위한 원격 자동소화 시스템 개발 연구 (Development of remote control automatic fire extinguishing system for fire suppression in double-deck tunnel)

  • 박진욱;유용호;김양균;박병직;김휘성;박상헌
    • 한국터널지하공간학회 논문집
    • /
    • 제21권1호
    • /
    • pp.167-175
    • /
    • 2019
  • 차량화재가 대부분인 터널 화재 사고에 효과적으로 대응하기 위해서는 초기에 화재를 진압하는 것이 가장 효율적이다. 그러나 도심지 터널의 경우 화재 사고시 차량 정체로 인해 소방대 투입이 어려워 신속한 소화 활동에 제약을 받으며, 이러한 문제는 최근 장대화 및 대심도화 되고 있는 지하도로(복층터널)의 경우 더욱더 심하게 나타날 것으로 판단된다. 국내의 경우 터널에서 발생되는 재난 재해에 대비하여 터널연장과 터널 조건별로 정해지는 위험도 지수를 토대로 연장등급과 방재등급을 산정하여 방재시설 설치 범위를 규정하고 있으며, 특히 터널 화재에 직접적으로 대응하기 위한 설비로 소화기구, 옥내소화전설비, 물분무설비 등을 등급에 따라 기본시설로 지정하고 있다. 그러나 이런 소화설비는 현실적으로 기능적이고 기술적인 측면에서 많은 약점이 발생되어 개선방안이 필요한 실정이다. 특히, 하나의 단면을 중간 슬래브로 나눠 상하행선으로 사용하는 형태인 복층터널의 경우 일반 소화설비보다 더 신속하고 효과적으로 화재 진압이 가능한 설비가 필요할 것으로 판단된다. 따라서 본 연구에서는 기존 터널 방재시설(소화설비)이 가지는 문제점을 보완하고, 복층터널의 구조적 특수성에 최적화된 원격 자동소화 시스템을 개발하였다. 그 결과로 낮은 층고를 고려한 장거리용 설비와 보급성을 확대한 옥내소화전용 설비 등 두 가지 형태의 시스템 개발을 완료하여 성능을 검증하였으며, 실제 터널에 보급되어 널리 활용될 수 있도록 현재 실용화를 추진 중에 있다.

도시 가로수 관리 품셈 개선에 관한 연구 (A Study on Improvement Methods of Cost Estimation in Order for the Proper Management of Street Trees)

  • 도윤택;한봉호;박석철
    • 한국조경학회지
    • /
    • 제50권4호
    • /
    • pp.20-36
    • /
    • 2022
  • 본 연구는 가로수 관리의 합리적인 표준품셈 항목 및 적정 단가 설정을 통한 고품질 가로수 관리의 기초자료 제공을 목적으로 하였다. 현재 가로수 관리항목은 가로수 전정을 제외하고, 일반 조경수 품셈을 가로수 관리 품셈으로 활용하고 있다. 또한 한국전력공사에서는 표준전기품셈의 가지치기 항목을 적용하여 표준품셈 대비 강전정의 경우 평균 51%, 약전정의 경우 평균 39% 낮은 단가로 사업을 수행하고 있다. 이는 가로수 관리 품질을 유지하거나 향상시킬 수 없는 한계로 판단되었으며, 가로수 관리의 적정 단가 기준이 필요함을 뜻한다. 가로수 관리 품셈을 개선하기 위해 현업에서 투입되는 비용을 검토할 필요가 있었다. 하지만 국내의 조경 분야 실적공사비에 대한 데이터의 부재로 미국 RSMeans Building Construction Cost Data(RSMeans)의 세부항목을 검토하였다. RSMeans란 1942년부터 누적된 미국의 실적기반 적산방식으로 주로 연방교통부와 각 주정부의 도로국을 중심으로 공사비를 산정하는 데이터베이스이다. RSMeans는 지속적인 신기술 도입과 노동 및 재료비용의 계속된 변경을 반영하기 위해 매해 건설제품과 방법을 찾고 수량화하며, 생산성 비율을 조정하고 있다. 본 연구에서는 국내 조경 관리 방법과 큰 차이가 없는 RSMeans의 세부항목과 현행 인건비 등을 적용하여 실적공사비를 산출하였다. 적용 결과 표준품셈은 실적공사비와 비교하면 가로수 전지의 강전정의 경우 107%로의 양호한 비율이었지만, 약전정은 59%로 과소 설계가 되어 있었다. 또한, 관목 전정은 82%, 제초는 92%, 교목 시비는 87%, 방풍벽 설치는 91% 수준으로 과소 설계되어 있었다. 살수차 관수와 약제 살포는 각각 118%와 124%의 비율로 실적공사비와 비교하면 과대 설계된 부분도 확인하였다. 과소평가된 항목들은 가로수의 특수성으로 도로 안전통제 등으로 인건비 및 장비의 투입비 상승이 주요 원인으로 판단되었다. 향후 표준품셈의 조경 유지 관리항목에 일반 조경수뿐만 아니라 가로수에 관한 항목 추가가 필요하다.