• Title/Summary/Keyword: RoHs

Search Result 89, Processing Time 0.022 seconds

Determination of halogen elements in plastics by using combustion ion chromatography (연소IC를 이용한 플라스틱 중 할로겐 물질 정량)

  • Jung, Jae Hak;Kim, Hyo Kyoung;Lee, Yang Hyoung;Lee, Lim Soo;Shin, Jong Keun;Lee, Sang Hak
    • Analytical Science and Technology
    • /
    • v.21 no.4
    • /
    • pp.284-295
    • /
    • 2008
  • For plastics samples, a method using combustion ion chromatography was selected as a method for rapid low-cost analysis to test whether hazardous substances are contained or not. Using combustion ion chromatography, a verification test for F, Cl and Br compounds generated a linear calibration curve with a correlation coefficient of $r^2$ = 0.999~1.000 in the calibration range from 0.5 to 4.0 mg/kg. The detection limits were found to be 0.005~0.024 mg/kg and quantitative limits were found to be 0.014~0.073 mg/kg. The recoveries of combustion ion chromatography using certified reference material (CRM) were found to be 95.5~104.9%. Based on these results, a proficiency test was conducted together with several laboratories in and out of the country, to make comparative analysis of the results from each laboratory. As a result, the data supported the use of combustion ion chromatography as an effective analysis method to deal with regulations for halogen-free electronic products and for other hazardous substances in the electronic products.

${SO_4}^{2-}$ ion Removal from Solution by Crystal Precipitation on Surface Active Glasses (표면활성유리에의 결정석출을 이용한 용액중 황산염 이온 제거)

  • 남명식;김철영
    • Journal of the Korean Ceramic Society
    • /
    • v.35 no.12
    • /
    • pp.1286-1293
    • /
    • 1998
  • ${SO_4}^{2-}$ ions present in industrial waste water if combined with other metal ions in the water can cause serious scale problem in a transporting pipe. In this study therefore ${SO_4}^{2-}$ ions in an acidic solution have been removed by using surface active glasses. Glasses with various compositions of $SiO_2-Na_2O-B_2O_3-RO$ (R=Mg, Ca, Sr, Ba) system were reacted in a ${SO_4}^{2-}$ ion-containing solution with various pHs ranging from 1 to 4 for various time the reacted glass surfaces were analyzed by XRD and SEM and all ions in the reacted solution were also measured ${SO_4}^{2-}$ ions in the solution were combined with divalent ions leached out of glass and precipitated on the glass surface as sulfate crystals. In this was the surface ion could be removed from the acidic solution. The sulfate ion removal capacity is closely related to the solubility product con-stants of the newly formed sulfate crystals. Almost no sulfate crystal was formed on the MgO-containing glass while sulfate crystals were easily formed on the glass containing either SrO or BaO This indicates that those glasses have strong removal efficiency of ${SO_4}^{2-}$ ions from the solution.

  • PDF

Degradation Behavior of Eutectic and Pb-free Solder Plated Ribbon in Crystalline Silicon Photovoltaic Module (유무연 용융도금 리본에 따른 결정질 실리콘 태양전지 모듈 열화거동)

  • Kim, Ju-Hee;Kim, A Yong;Park, Nochang;Ha, Jeong Won;Lee, Sang Guon;Hong, Won Sik
    • Journal of Welding and Joining
    • /
    • v.32 no.6
    • /
    • pp.75-81
    • /
    • 2014
  • Usage of heavy metal element (Pb, Hg and Cd etc.) in electronic devices have been restricted due to the environmental banning of the European Union, such as WEEE and RoHS. Therefore, it is needed to develop the Pb-free solder plated ribbon in photovoltaic (PV) module. This study described that degradation characteristics of PV module under damp heat (DH, $85^{\circ}C$ and 85% R.H.) condition test for 1,000 h. Solar cell ribbons were utilized to hot dipping plate with Pb-free solder alloys. Two types of Pb-free solder plated ribbons, Sn-3.0Ag-0.5Cu (SAC305) and Sn-48Bi-2Ag, and an electroless Sn-40Pb solder hot dipping plated ribbon as a reference sample were prepared to evaluate degradation characteristics. To detect the degradation of PV module with the eutectic and Pb-free solder plated ribbons, I-V curve, electro-luminescence (EL) and cross-sectional SEM analysis were carried out. DH test results show that the reason of maximum power (Pm) drop was mainly due to the decrease fill factor (FF). It was attributed to the crack or oxidation of interface between the cell and the ribbon. Among PV modules with the eutectic and Pb-free solder plated ribbon, the PV module with SAC305 ribbon relatively showed higher stability after DH test than the case of PV module with Sn-40Pb and Sn-48Bi-2Ag solder plated ribbons.

Evaluation of the proficiency testing results for brominated flame retardants in high impact polystyrene (고충격폴리스티렌 중 브롬계 난연제 숙련도시험 결과 평가)

  • Kim, Dal-Ho;Ryu, Je-Hoon;Choi, Yong-Wook
    • Analytical Science and Technology
    • /
    • v.24 no.6
    • /
    • pp.435-442
    • /
    • 2011
  • Polybrominated diphenyl ethers (PBDEs) are a class of brominated flame retardants (BFRs) which have taken much interest recently due to their potential hazardous effects to human body and ecosystem. Many countries and European community prohibits the usage of certain BFRs in electronics and electronic devices (e.g. RoHS). In this perspectives, Korea Research Institute of Standards and Science (KRISS) has designed and practiced proficiency testing programs based on the ISO/IEC 17043 in order to assist laboratory accreditation activities. The programs for interlaboratory comparisons include congeners of PBDE (PBDE-154, 183, 206, 209) in high impact polystyrene (HIPS). A sample bottle that contains 10 g granular HIPS was distributed to 35 participating laboratories and the test results were calculated by the statistical procedure using z-scores to evaluate performance of each laboratory. The results and the laboratory's performance were discussed.

Evaluation of the Corrosion Resistance of Steel Coated with Zinc Using a Cr-free Coating Solution as a Function of Heat Treatment Time (Cr-free 코팅액에 의한 아연도금강판의 건조시간에 따른 내식특성)

  • Seo, Hyun-Soo;Moon, Hee-Joon;Kim, Jong-Soon;Ahn, Seok-Hwan;Moon, Chang-Kwon;Nam, Ki-Woo
    • Journal of Ocean Engineering and Technology
    • /
    • v.24 no.5
    • /
    • pp.67-74
    • /
    • 2010
  • Chromate conversion coating is a coating technique used to passivate aluminum, zinc, cadmium, copper, silver, magnesium, tin, and their alloys to slow corrosion. The process uses various toxic chromium compounds, which may include hexavalent chromium. The industry is developing less toxic alternatives in order to comply with substance restriction legislation, such as RoHS. One alternative is to develop a Cr-free coating solution. In this study, eco-friendly, Cr-free solutions (urethane solution S-700, organic/inorganic solution with Si LRO-317) were used. Test specimens were dried in a drying oven at $190^{\circ}C$ for 3, 5, 7, and 9 minutes. Corrosion resistance was evaluated using a salt spray test for 72 hours. The results show that the optimum corrosion resistance was achieved at $190^{\circ}C$ for five minutes for EGI and three or five minutes for HDGI, respectively. The adhesive properties of the two types of coating solutions were superior regardless of drying time.

Evaluation of the Corrosion Resistance of Zn-Coated Steel as a Function of the Temperature of the Cr-free Solution Used to Coat the Steel (Cr-free 코팅액에 의한 아연도금강판의 열처리 온도에 따른 내식특성)

  • Seo, Hyun-Soo;Moon, Hee-Joon;Kim, Jong-Soon;Ahn, Seok-Hwan;Moon, Chang-Kwon;Nam, Ki-Woo
    • Journal of Ocean Engineering and Technology
    • /
    • v.24 no.5
    • /
    • pp.60-66
    • /
    • 2010
  • Zinc has a number of characteristics that make it well suited for use as a coating to protecting iron and steel products from corrosion. Its excellent corrosion resistance in most environments accounts for its successful use as a protective coating on a variety of products and in many exposure conditions. The excellent field performance of zinc coatings results from their ability to form dense, adherent films that corrode at a rate that ranges from 1% to 10% of the corrosion rate of ferrous materials, depending on the environment. Recently, EU RoHS and EU ELV prohibited the use of materials that adversely affect the environment, such as Pb, Hg, Cd, and $Cr^{+6}$. In this study, environmentally-friendly, Cr-free solutions (epoxy solution, acrylic solution, and urethane solution S-700) and organic/inorganic solution with Si; LRO-317) were used to evaluate the corrosion resistance of zinc-coated steel subjected to a saltwater spray for 72 hours. The coating of urethane solution (S-700) was best among the three kinds of solution with heat treatment during five minutes at $190^{\circ}F$. Test specimens with S-700 and LRO-317 coating were heat treated in a drying oven at 170, 180, 190, 200, and $210^{\circ}C$ for five minutes. The results show that the optimum corrosion resistance was $190^{\circ}C$ in EGI and $170^{\circ}C$ in HDGI, respectively.

Electrochemical Ion Migration Sensitivity of Printed Circuit Board Plated with Sn-3.0Ag-0.5Cu and Sn-37Pb (Sn-3.0Ag-0.5Cu, Sn-37Pb 표면처리 기판의 전기화학적 이온 마이그레이션 민감도)

  • Hong, Won-Sik;Park, No-Chang;O, Cheol-Min;Kim, Gwang-Bae
    • Proceedings of the KWS Conference
    • /
    • 2006.10a
    • /
    • pp.136-138
    • /
    • 2006
  • Recently a lots of problems have observed in high densified and high integrated electronic components. One of them is ion migration phenomena, which induce the electrical short of electrical circuit. Ion migration phenomena has been observed in the field of exposing the specific environment and using for a long time. Also as the RoHS restriction was started in July 1st, 2006, Pb-free solder was utilized in electronics assemblies. In this case, it is very important to compatible between components and printed circuit board(PCB), thus surface treatment materials of PCB was changed to Sn, Sn-3.0Ag-0.5Cu, Cu. Therefore these new application become to need to reevaluate the sensitivity about electrochemical ion migration. This study was evaluated the occurrence time of electrochemical ion migration using by water drop test. We utilized PCB(printed circuit board) having a comb pattern as follows 0.1, 0.318, 0.5, 1.0 mm pattern distance. Sn-3.0Ag-0.5Cu and Sn-37Pb were electroplated on the comb pattern. 6.5V and 15.0V were applied in the comb pattern and then we measured the electrical short time causing by occurring the ion migration. In these results, we evaluate the sensitivity and derived the prediction models of ion migration occurrence time depending on the pattern materials, applied voltage and pattern spacing of PCB conductor.

  • PDF

Validation of sequence test method of Pb-free solder joint for automotive electronics (자동차 전장품용 무연솔더 접합부의 시리즈 시험 유효성)

  • Kim, A Young;Oh, Chul Min;Hong, Won Sik
    • Journal of Welding and Joining
    • /
    • v.33 no.3
    • /
    • pp.25-31
    • /
    • 2015
  • Due to environmental regulations (RoHS, WEEE and ELV) of the European Union, electronics and automotive electronics have to eliminate toxic substance from electronic devices and system. Specifically, reliability issue of lead-free solder joint have an increasing demand for the car electronics caused by ELV banning. The authors prepared engine control unit and cabin electronics soldered with Sn-3.0Ag-0.5Cu (SAC305). To compare with the degradation characteristics of solder joint strength, thermal cycling test (TC), power-thermal cycling test (PTC) and series tests were conducted. Series tests were conducted for TC and PTC combined stress test using the same sample in sequence and continuously. TC test was performed at $-40{\sim}125^{\circ}C$ and soak time 10 min for 1000 cycles. PTC test was applied by pulse power and full function conditions during 100 cycles. Combined stress test was tested in accordance with automotive company standard. Solder joint degradation was observed by optical microscopy and environment scanning electron microscopy (ESEM). In addition, to compare with deterioration of bond strength of quad flat package (QFP) and chip components, we have measured lead pull and shear strength. Based on the series test results, consequently, we have validated of series test method for lifetime and reliability of Pb-free solder joint in automotive electronics.

The effect on dispersibility of additive elements in Cr+6 free chemical conversion coating solution (Cr+6 free 화성피막 용액의 분산성에 미치는 첨가 원소의 영향)

  • Park, Jeong-Hwan;Kim, Tae-Won;Jo, Dae-Hyeong;Kim, Jeong-Su;Han, Su-Min;Jeong, Dae-Hui;Jeon, Gyu-Seong
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2017.05a
    • /
    • pp.104-104
    • /
    • 2017
  • 유럽의 폐차 처리 지침, RoHs 및 국내 친환경 소재 부품의 개발이 날로 가속화 되면서 종래 사용해 오던 인산염 피막 등 중금속이 함유된 코팅 재료는 점차 친환경 코팅 용액으로 전환이 되었다. 최근 자동차 산업 등에서 종래 중금속인 $Cr^{+6}$을 함유하지 않는 다양한 코팅 용액이 상용화 되고 있다. 그 중 가장 효율적으로 적용되고 있는 용액이 아연 flake를 첨가하여 희생 양극효과를 가능하게 하여 내식용 코팅 용액으로 상용화 하고 있다. 이 용액에는 내식성을 확보하기 위하여 희생양극이 가능한 소재 인 아연 분말을 첨가하며, 이 분말의 분산성이 소재와 코팅 층의 밀착성, 내식성에 결정적인 영향을 미친다. 특히 산업 현장에서는 아연 분말의 효율적인 분산을 위하여 24시간 이상 교반해야하기 때문에 생산성을 감소시키는 결정적인 요인으로 작용을 한다. 아연 분말의 분산은 용액 내에 첨가하는 각종 첨가제의 종류와 첨가량에 따라 현저하게 분산성이 다르기 때문에 첨가 원소에 대한 연구가 매우 중요하다. 본 연구에서는 서로 다른 이종 합금을 첨가하여 각종 첨가제의 종류 및 첨가량이 분산에 미치는 영향을 조사하였고, 첨가량이 코팅 층의 밀착성 및 내식성에 미치는 영향에 대하여 연구하였다. 분산제 첨가량이 낮을 경우 용액은 두껍게 코팅이 되며 분산 거리가 짧아졌다. 이 경우 코팅 층의 박리가 쉽게 발생하며, 코팅 층이 불균일하였다. 1.7% 첨가량에서 최적분산효과를 얻을 수 있었으며, 1,000시간 이상의 내식성을 확보할 수 있었다. 분산성과 동시에 유동성 확보가 중요하며, 유동성 확보를 위하여 점증제의 첨가량에 대한 변화를 주었다. 최적의 첨가량은 1.5% 이상으로 이 경우 부식 발생시간을 억제할 수 있었다.

  • PDF

A study on corrosion resistance of color coated steel sheet using Magnesium-adopted alloy plated steel sheet (마그네슘 첨가 합금도금강판을 이용한 칼라도장강판의 내식특성에 관한 연구)

  • Lee, Gyeong-Hwang;Yang, Ji-Hun;Jeong, Jae-In
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2018.06a
    • /
    • pp.44-44
    • /
    • 2018
  • 칼라도장강판은 금속 제품의 제품화 공정 중에 도장 공정을 생략함으로 경제적이며, 제조공정 중 발생할 수 있는 VOCs(Volatile Organic Compounds)의 배출 염려가 없어 건축 및 가전 산업에 다용되고 있다. 칼라도장강판은 용융아연도금강판(GI), 전기아연도금강판(EGI), 용융알루미늄아연합금도금강판 등이 기재로 적용되고 있으며, 최근 마그네슘 성분이 첨가되는 고내식 도금강판 개발과 함께 고내식 도금강판을 이용한 칼라도장강판의 개발 및 수요 발굴을 위한 연구가 활발하게 진행 중에 있다. 칼라강판의 구성은 일반적으로 도막 밀착성 확보를 위한 화성처리층, 기재와 도막간의 밀착성과 내식성 개선을 위한 하도층(primer layer), 가공성, 내오염성, 의장성 등의 기능성 부여를 위한 상도층(top layer)의 구조로 도장되어 있다. 도료는 가공성, 내오염성, 경도 등의 기능성이 우수한 폴리에스테르 수지계가 가장 폭넓게 사용되고 경화제로는 멜라민 화합물과 이소시아네이트 화합물이 널리 사용되고 있다. 칼라도장 강판은 1970년대 이후 본격적으로 보급되어 사용되기 시작하였으며, 화성처리층은 밀착성과 내식성이 우수한 크로메이트처리가 널리 사용되고, 하도층은 방청성이 우수한 크로메이트계 방청 안료를 함유시킨 도료가 일반적이다. 그러나, 전기전자 제품에 적용되는 칼라도장강판은 2006년에 RoHS 규제의 시행과 더불어 6가 크롬 사용 제한의 영향으로 크롬프리 화성처리가 일반화되어 적용되고 있으며, 그 동안 6가 크롬 제안이 유보적이었던 건축용 칼라도장강판 또한 크롬프리 화성처리층 및 크로메이트계 방청 안료의 하도층 적용을 회피하고 있는 추세이다. 이에 따라, 고내식 합금도금강판을 기재로 사용하고 기존의 화성처리층과 하도층에 크롬프리 수지를 적용하는 연구개발이 활발하게 진행 중에 있다. 본 연구에서는 마그네슘이 첨가된 고내식 합금도금강판으로 Al-Mg-S i강판과 용융 Zn-Al-Mg 합금도금강판에 기존의 상용화 공정에서 사용되는 크롬계 및 크로프리 화성처리 적용 칼라도장강판에 대한 내식성 등 칼라도장강판의 특성에 대해 발표한다.

  • PDF