• Title/Summary/Keyword: Rms

Search Result 2,308, Processing Time 0.029 seconds

A Study for Effects of Image Quality due to Scatter Ray produced by Increasing of Tube Voltage (관전압 증가에 기인한 산란선 발생의 화질 영향 연구)

  • Park, Ji-Koon;Jun, Je-Hoon;Yang, Sung-Woo;Kim, Kyo-Tae;Choi, Il-Hong;Kang, Sang-Sik
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.7
    • /
    • pp.663-669
    • /
    • 2017
  • In diagnostic medical imaging, it is essential to reduce the scattered radiation for the high medical image quality and low patient dose. Therefore, in this study, the influence of the scattered radiation on medical images was analyzed as the tube voltage increases. For this purpose, ANSI chest phantom was used to measure the scattering ratio, and the scattering effect on the image quality was investigated by RMS evaluation, RSD and NPS analysis. It was found that the scattering ratio with increasing x-ray tube voltage gradually increased to 48.8% at 73 kV tube voltage and to 80.1% at 93 kV tube voltage. As a result of RMS analysis for evaluating the image quality, RMS value according to increase of tube voltage was increased, resulting in low image quality. Also, the NPS value at 2.5 lp/mm spatial frequency was increased by 20% when the tube voltage was increased by 93 kV compared to the tube voltage of 73 kV. From this study, it can be seen that the scattering radiation have a significant effect on the image quality according to the increase of x-ray tube voltage. The results of this study can be used as basic data for the improvement of medical imaging quality.

The Effect of Increased Dilution Volume and Prolonged Infusion Time of Vancomycin on Incidence of Adverse Reactions through Peripheral Venous Cannulae (말초정맥을 통한 반코마이신희석과 주입시간연장이 부작용발생에 미치는 영향)

  • Oh, Myeong Ju;Kim, Mae Ja
    • Korean Journal of Adult Nursing
    • /
    • v.12 no.2
    • /
    • pp.196-208
    • /
    • 2000
  • The purpose of the study was to explore the effect of 2 hour infusion of vancomycin(1g) in 200ml of isotonic saline every 12 hour on the frequency of "red man syndrome", phlebitis and length of peripheral catheter placement of infected patients, in order to provide safe infusion method for reducing vancomycinin-duced RMS and phlebitis. The subjects of the study consisted of 16 hospitalized patients; 3 oncology and gastro-intestinal patients, 1 neurological patient, 6 thoracic surgical patients and 6 orthopedic patients, who had received vancomycin from July to October in 1999 at S-hospital. The dependent variables were the incidence of RMS, phlebitis and the length of peripheral catheter placement. The incidence of RMS was checked by an inspector at the first night whenever the infusion method of vancomycin was changed. RMS was observed every 15 minutes during an hour for symptoms of RMS such as itching, erythema, chest pain and systolic blood pressure. Incidence of phlebitis was assessed by inspector twice a day from the insertion of peripheral catheter to the removal of the catheter. The data were analyzed by percentage, mean, $X^2$-test, t-test, repeated ANOVA, and logistic regression analysis using the SPSSWIN program. The results are summarized as follows; 1. No significant difference was identified in frequency of RMS between the experimental group and control group. 2. There was no significant difference in the change of systolic blood pressure as the time goes on between the experimental group and control group. 3. The incidence of phlebitis was significantly lower in the experimental group than in the control group. 4. The length of peripheral catheter placement was significantly longer in the experimental group than in the control group. 5. Other drugs administrated with vancomycin didn't influence the occurrence of phlebitis. However, the infusion method of vancomycin influenced the occurrence of phlebitis. The results suggest that 2 hour infusion of vancomycin(1g) in 200ml of isotonic saline every 12 hours may decrease the incidence of phlebitis and increase the length of peripheral catheter placement compared to 1 hour infusion of vancomycin(1g) in 100ml of isotonic saline every 12 hours. However, it does not reduce the incidence of RMS.

  • PDF

Unsteady 2-D flow field characteristics for perforated plates with a splitter

  • Yaragal, Subhash C.
    • Wind and Structures
    • /
    • v.7 no.5
    • /
    • pp.317-332
    • /
    • 2004
  • Wind tunnel experiments were conducted under highly turbulent and disturbed flow conditions over a solid/perforated plate with a long splitter plate in its plane of symmetry. The effect of varied level of perforation of the normal plate on fluctuating velocities and fluctuating pressures measured across and along the separation bubble was studied. The different perforation levels of the normal plate; that is 0%, 10%, 20%, 30%, 40% and 50% are studied. The Reynolds number based on step height was varied from $4{\times}10^3$ to $1.2{\times}10^4$. The shape and size of the bubble vary with different perforation level of the normal plate that is to say the bubble is reduced both in height and length up to 30% perforation level. For higher perforation of the normal plate, bubble is completely swept out. The peak turbulence value occurs around 0.7 to 0.8 times the reattachment length. The turbulence intensity values are highest for the case of solid normal plate (bleed air is absent) and are lowest for the case of 50% perforation of the normal plate (bleed air is maximum in the present study). From the analysis of data it is observed that $\sqrt{\overline{u^{{\prime}2}}}/(\sqrt{\overline{u^{{\prime}2}}})_{max}$, (the ratio of RMS velocity fluctuation to maximum RMS velocity fluctuation), is uniquely related with dimensionless distance y/Y', (the ratio of distance normal to splitter plate to the distance where RMS velocity fluctuation is half its maximum value) for all the perforated normal plates. It is interesting to note that for 50% perforation of the normal plate, the RMS pressure fluctuation in the flow field gets reduced to around 60% as compared to that for solid normal plate. Analysis of the results show that the ratio [$C^{\prime}_p$ max/$-C_{pb}(1-{\eta})$], where $C^{\prime}_p$ max is the maximum coefficient of fluctuating pressure, $C_{pb}$ is the coefficient of base pressure and ${\eta}$ is the perforation level (ratio of open to total area), for surface RMS pressure fluctuation levels seems to be constant and has value of about 0.22. Similar analysis show that the ratio $[C^{\prime}_p$ max/$-C_{pb}(1-{\eta})]$ for flow field RMS pressure fluctuation levels seems to be constant and has a value of about 0.32.

Numerical Study on the Baffle Structure for Determining the Flow Characteristic in Small Scale SCR System (소형 SCR 시스템 내 유동 제어를 위한 Baffle의 구조 결정에 관한 수치해석적 연구)

  • Park, Mi-Jung;Chang, Hyuk-Sang;Ha, Ji-Soo
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.32 no.9
    • /
    • pp.862-869
    • /
    • 2010
  • Numerical analysis was done to evaluate the gas flow distribution in small scale SCR system which has $2.4{\times}2.4{\times}3.1\;m^3$ in volume and 25,300 Sm3/hr in flue gas flow capacity. Various types of baffles proposed for controlling the flow uniformity were evaluated by the CFD analysis to find the optimal geometry of the baffle in the SCR system. By installing baffles in the SCR system, the RMS (%) value was raised up to 6.2% compared with the baffle-uninstalled state. The effect of baffle thicknesses on the RMS (%) value was not shown within 0 and 8 mm in thickness, but the RMS (%) value was raised by 2.5% in 10 mm of baffles thickness, which causes the unstability in flow. By comparison between the shape of baffles, it is known that the lattice type baffle has better performance in controlling the flow uniformity than the circular truncated cone type baffle or mixer type baffle. RMS (%) values have more that 10% difference according to the shape of baffle type.

The study on characterization of current limit and fabrication of device for current limit formed by thick film (후막형 전류제한소자제작과 전류제한특성 연구)

  • Lim, Sung-Hun;Kang, Hyeong-Gon;Choi, Myung-Ho;Han, Byung-Sung
    • Proceedings of the KIEE Conference
    • /
    • 1999.07d
    • /
    • pp.1704-1706
    • /
    • 1999
  • $YBa_2Cu_3O_x$ superconducting thick film was fabricated by surface diffusion process of $Y_2BaCUO_5$ and the mixed compound of $(3BaCuO_2+2CuO)$ expected to be liquid phase above the peritectic temperature of YBa2Cu30x. For the surface diffusion. 3BaCu02+2CuO mixed with binder material was patterned on $Y_2BaCuO_5$ substrate by the screen printing method. The characteristic of current limit on thick film fabricated was measured. The thick film limited the current from $2.8213mA_{rms}$ to $4.2034mA_{rms}$ with $500{\Omega}$ load resistance, and from $4.1831mA{rms}$ to $4.2150mA_{rms}$ with $10{\Omega}$ load resistance.

  • PDF

Pattern Classification Algorithm for Wrist Movements based on EMG (근전도 신호 기반 손목 움직임 패턴 분류 알고리즘에 대한 연구)

  • Cui, H.D.;Kim, Y.H.;Shim, H.M.;Yoon, K.S.;Lee, S.M.
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.7 no.2
    • /
    • pp.69-74
    • /
    • 2013
  • In this paper, we propose the pattern classification algorithm of recognizing wrist movements based on electromyogram(EMG) to raise the recognition rate. We consider 30 characteristics of EMG signals wirh the root mean square(RMS) and the difference absolute standard deviation value(DASDV) for the extraction of precise features from EMG signals. To get the groups of each wrist movement, we estimated 2-dimension features. On this basis, we divide each group into two parts with mean to compare and promote the recognition rate of pattern classification effectively. For the motion classification based on EMG, the k-nearest neighbor(k-NN) is used. In this paper, the recognition rate is 92.59% and 0.84% higher than the study before.

  • PDF

A Ku-Band 5-Bit Phase Shifter Using Compensation Resistors for Reducing the Insertion Loss Variation

  • Chang, Woo-Jin;Lee, Kyung-Ho
    • ETRI Journal
    • /
    • v.25 no.1
    • /
    • pp.19-24
    • /
    • 2003
  • This paper describes the performance of a Ku-band 5-bit monolithic phase shifter with metal semiconductor field effect transistor (MESFET) switches and the implementation of a ceramic packaged phase shifter for phase array antennas. Using compensation resistors reduced the insertion loss variation of the phase shifter. Measurement of the 5-bit phase shifter with a monolithic microwave integrated circuit demonstrated a phase error of less than $7.5{\circ}$ root-mean-square (RMS) and an insertion loss variation of less than 0.9 dB RMS for 13 to 15 GHz. For all 32 states of the developed 5-bit phase shifter, the insertion losses were $8.2{\pm}1.4$dB, the input return losses were higher than 7.7 dB, and the output return losses were higher than 6.8 dB for 13 to 15 GHz. The chip size of the 5- bit monolithic phase shifter with a digital circuit for controlling all five bits was 2.35 mm ${\times}$1.65 mm. The packaged phase shifter demonstrated a phase error of less than $11.3{\circ}$ RMS, measured insertion losses of 12.2 ${\pm}$2.2 dB, and an insertion loss variation of 1.0 dB RMS for 13 to 15 GHz. For all 32 states, the input return losses were higher than 5.0 dB and the output return losses were higher than 6.2 dB for 13 to 15 GHz. The size of the packaged phase shifter was 7.20 mm${\times}$ 6.20 mm.

  • PDF

Equivalent RMS Sine-wave Modulation of the Step-pulse type Multi-level Inverter (스텝펄스형 멀티레벨 인버터를 위한 RMS 등가형의 새로운 사인파 변조법)

  • Jin, Sun-Ho;Kwak, Jun-Ho;Jo, Kwan-Jun;Oh, Jin-Seok
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.11 no.3
    • /
    • pp.239-246
    • /
    • 2006
  • This paper suggests a new modulation strategy for step pulse type multi-level inverter. The proposed strategy is simple to determine the switching angles without regard to increase of levels. Designed to extract the equivalent RMS value compared to ideal sine wave from inverter, it can be applied effectively to high level step pulse inverter. Also this paper proposed modulation strategy for modified H-bridge 13 level inverter which has different cell source voltages with simulation and experiment. The modulation characteristics from simulation and experiment, agreed very well with tracing sine wave about modified structure of cascaded H-bridge multi-level inverter.

A Study on the In-process Detection of Fracture of Endmill by Acoustic Emission Measurement (음향방출을 이용한 가공중의 엔드밀 파손 검출에 관한 연구)

  • Yoon, Jong-Hak;Kang, Myung-Soon
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.7 no.3
    • /
    • pp.75-82
    • /
    • 1990
  • Automatic monitoring of the cutting conditions is one of the most improtant technologies in machining. In this study, the feasibility in applying acoustic emission(AE) signals for the in-process detection of endmill wear and fracture has been investigated by performing experimental test on the NC vertical milling machine with SM45C for specimen. As the results of detecting and analyzing AE signals on various cutting conditions, the followings have confirmed. (1) The RMS value of acoustic emission is related sensitively to the cutting velocity, but is not affected largely by feed rate. (2) The burst type AE signals of high level have been observed when removing chips distorderly and discontinuously. (3) When the RMS value grows up rapidly due to the increase of wear the endmill are generally broken or fractured, but when the endmills fracture at the conditions of smooth chip-flow or built-up-edge(BUE) occurred frequently, the rapid change of the RMS arenot found. And it is expected that this technigue will be quite useful for in-process sensing of tool wear and fracture.

  • PDF

Open Boundary Conditions Considering the Radiating Effect (방사효과를 고려한 개방경계조건)

  • Suh, Seung Won;Shin, Eung Bai;Yoon, Tae Hoon
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.9 no.2
    • /
    • pp.63-71
    • /
    • 1989
  • The objective of this study is to enhance the reliability of the computed results by setting up of an improved treatments onto the open boundary condition for tidal motion in finite domain. By the $L^2-norm$ and RMS error tests, it was revealed that Sommerfeld's radiating condition gives better result than a forced boundary condition. In the numerical tests for a long wave in a simplified rectangular bay, it was found that the computational accuracy of the newly improved technique to the Sommerfeld condition, suggested in this study with the 2 dimensional shallow finite element model, could be improved by 30% of RMS error to the existing Sommerfeld condition.

  • PDF