• Title/Summary/Keyword: Risk Voltage

Search Result 173, Processing Time 0.022 seconds

Analysis Technique of Risk Voltage around Grounding Electrode by New Touch and Step Voltage Measurement Methods (새로운 접촉 및 보폭전압 측정법에 의한 접지전극 주위의 위험전압 분석기법)

  • Gil, Hyoung-Jun;Kim, Hyang-Kon
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.26 no.6
    • /
    • pp.81-86
    • /
    • 2012
  • This paper describes the analysis technique of risk voltage around grounding electrode by new touch and step voltage measurement methods. We have analyzed three techniques for risk voltage measurement, such as footprint-electrode method, test-probe method, and simulated-personnel method. We have selected test-probe method considering applicability of site. In order to reduce error related to the location of the auxiliary electrode, we propose a new approach to perform risk voltage measurement with minimum errors and short auxiliary electrode distances. Field tests were carried out at a grounding grid. It can be concluded that the proposed method will be satisfactory for risk voltage measurement.

Measurement and Analysis of Risk Voltages by Various Current Sources in Grounding System (다양한 전류원에 대한 접지시스템의 위험전압 측정과 분석)

  • Kil, Gyung-Suk;Moon, Byoung-Doo;Kim, Hwang-Kuk;Park, Dae-Won;Gil, Hyoung-Jun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.1
    • /
    • pp.113-118
    • /
    • 2009
  • Grounding systems set the reference voltage level of electric circuits and suppress the Ground Potential Rise (GPR) by flowing fault currents to the ground safely. There are several parameters which evaluate the performance of grounding systems as ground resistance, touch voltage and step voltage. The touch and step voltages, which is called "risk voltage", are especially important to ensure the safety of human body. This paper dealt with the influence of current sources with the different frequency components on the touch and the step voltages. Three types of current sources as commercial frequency, square wave, and surge with the fast risetime of $50\;ns{\sim}500\;ns$ were used to analyze the risk voltages in a grounding system. The risk voltages showed remarkable difference in the same current amplitude depending on the current sources, and increased linearly with the current amplitude in the same current source. From the experimental results, it was confirmed that the risk voltages can be evaluated by a small current application in large-scale grounding systems and the possible largest risk voltage can be calculated by a surge current with the risetime of 200 ns or a current source with the same frequency component as the surge current.

Measurement and Analysis of Risk Voltages in a Grounding System (접지계에서 위험전압의 측정과 분석)

  • Jin, Chang-Hwan;Park, Dae-Won;Seo, Jae-Seok;Kil, Gyung-Suk;Gil, Hyeong-Jun
    • Proceedings of the KSR Conference
    • /
    • 2011.10a
    • /
    • pp.3099-3103
    • /
    • 2011
  • In measurement of risk voltages; the step and touch voltage, the distance between the current electrode and the ground electrode recedes up to several hundred meters as the scale of grounding system increases. This paper dealt with the measurement method of risk voltage in a restricted space. The risk voltage was analyzed depending on the distance and the direction of the current electrode from the ground electrode in a $10[m]{\times}10[m]$ mesh grounding system. The average value of risk voltages measured at a point 20 [m] away from the current electrode was deviated below 5 [%] from that measured at 100 [m] point. Consequently, the evaluation of risk voltage of a large-scale grounding system buried in a spatially restricted place is available if the current electrode is installed in symmetry to the ground electrode.

  • PDF

Measurement and Analysis of the Dangerous Voltage Around Grounding Electrode for Safety in Substation Ground (변전소 접지설계를 위한 접지전극 주변의 위험전압 측정과 분석)

  • Son, Seok-Geum;Kim, Jae-Chul
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.60 no.4
    • /
    • pp.214-219
    • /
    • 2011
  • The substation grounding design,"IEEE Guide for Safety in AC Substation Grounding (ANSI / IEEE Std 80)"has been widely used. Substation grounding design and substation grounding resistance of grounding network site to predict the voltage at the risk of a very important task, which is a ground fault current due to the influx of the ground network and due to rise in the Earth's potential can be applied to human dangerous Voltage within safe tolerances be configured to be the ground because the network. IEEE Std. 80 for the substation construction safety equipment on the ground securing the ground electrode and the mesh around the boundary potential distribution in terms of risk analysis by the touch voltage and the reference was to clean up the definition and the basic steps of the voltage of the voltage limits the risk of peripheral grounding electrode Suppression by the simulator through a new secure from dangerous voltage design techniques were presented.

Countermeasure of Voltage Sag in Radial Power Distribution System using Load Transfer Switching (부하 절환 스위칭을 이용한 방사상 배전계통에서의 순간전압강하 대책)

  • Yun, Sang-Yun;Oh, Jung-Hwan;Kim, Jae-Chul
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.49 no.11
    • /
    • pp.558-565
    • /
    • 2000
  • In this paper, we propose a method for mitigating for mitigating the effect of voltage of voltage sag in radial power distribution systems using load transfer switching (LTS). The term of LTS is defined that the weakness load points for voltage sag transfer to the alternative source during the fault clearing practices. The sequenced of proposed LTS method is divided into the search of weakness points for voltage sag using the risk assessment model and transfer behavior of weakness points. The search of weakness point is carried out using the risk assessment model of voltage sag and Monte Carlo simulation method and the historical reliability data in Korea Electric Power Corporation (KEPCO) are also used. Through the case studies, we verify the effectiveness of proposed LTS method and present the searching method of effective application points of LTS method using the risk assessment model.

  • PDF

Design and Application of a Ground Risk Voltage Measurement System (대지 위험전압 측정기의 설계 및 적용)

  • Jang, Un-Yong;Cha, Hyeon-Kyu;Cha, Sang-Wook;Park, Dae-Won;Kil, Gyung-Suk
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.24 no.3
    • /
    • pp.250-255
    • /
    • 2011
  • This paper dealt with the design, fabrication and application of a risk voltage measurement system (RVMS) which analyzes the step and touch voltages in electrical grounding systems. The RVMS supply 300 V and 1.4 A in ranges from 40 Hz to 1 kHz as the test power source. A DAQ module having resolution of 400 kS/s and 16 bit is equipped with 7 inputs for measuring voltage and current. Also, a noise elimination algorithm of digital filter was applied to reduce the measurement error caused by external noises as a commercial frequency current. The performance of the RVMS was evaluated by measurement of the step and touch voltage according to the IEEE standard 80 and 81 in a grounding system with a 10 m counterpoise. The result showed that the RVMS analyzes the risk voltage with the error below 5%.

Analysis of Risk Voltage for Grounding Electrode by Injection of Earth Leakage Current

  • Gil, Hyoung-Jun;Kim, Dong-Woo;Kim, Dong-Ook;Lee, Ki-Yeon;Moon, Hyun-Wook;Kim, Hyang-Kon;Kil, Gyung-Suk
    • International Journal of Safety
    • /
    • v.8 no.2
    • /
    • pp.9-14
    • /
    • 2009
  • This paper describes analysis of risk voltage for grounding electrode where earth leakage current is injected. To assess risk voltage of grounding electrode, the grounding simulator and CDEGS program were used to obtain measured data and theoretical results of this study. The grounding simulator was composed of a hemispherical water tank, AC power supply, a movable potentiometer, and test grounding electrodes. The shapes of grounding electrode model was ground rod. The potential rise was measured by grounding simulator, and the touch and step voltages were computed by CDEGS program. As a consequence, the potential rise of ground rod abruptly decreases with increasing the distance from the grounding electrode to the point to be tested. The touch voltage above the ground rod was low, but the step voltage was high. The measured results were compared with the computer calculated data and were known in good agreement.

Assessing the Effect of Voltage Sag in Distribution System Using a Fuzzy Risk Assessment Model (퍼지 위험도 평가 모델을 이용한 배전계통의 순간전압강하 영향 평가)

  • Yun, Sang-Yun;Oh, Jung-Hwan;Han, Byung-Duk;Kim, Jae-Chul;Park, Joong-Shin;Lim, Dong-Gyun
    • Proceedings of the KIEE Conference
    • /
    • 1999.07c
    • /
    • pp.1085-1087
    • /
    • 1999
  • In this paper, we propose the method for assessing the effect of voltage sag in power distribution system using fuzzy risk assessment model. The proposed method is based on SCBEMA curve that expresses the representative susceptibility curve by voltage sag for each customer type. These corves are made using the CBEMA curves obtained from the experiment for the customers'sensitive equipment. In order to transform SCBEMA curves to the probability damage by voltage sag, the fuzzy risk assessment model is used in this paper. Case studies were performed to analyze the effect of voltage sag by varying parameters. The Monte Carlo simulation method and the historical reliability data in KEPCO are used for case studies.

  • PDF

Judgement of the need for Over-Voltage Control of the Low-Voltage Electrical Installations (저압 전기설비의 과전압 억제 필요성 판단)

  • Lee, Ju-Cheol;Kim, Jae-Chul
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.29 no.2
    • /
    • pp.91-96
    • /
    • 2015
  • There are provision for risk analysis in IEC standards. It is to determine the need for installation of a surge protection device (SPD) in order to protect the low-voltage electrical installations from overvoltages caused by atmospheric phenomena and the like. However, scattered many related standards, the lack of details are not easy to apply it in the field. We investigated the relevant domestic and international standards for applies to the international standards in domestic. And we proposed the flow chart for determining the need for protection of the low-voltage electrical installations from overvoltage due to atmospheric phenomena and it set the appling target facility.

Increased Risk of Childhood Acute Lymphoblastic Leukemia (ALL) by Prenatal and Postnatal Exposure to High Voltage Power Lines : A Case Control Study in Isfahan, Iran

  • Tabrizi, Maral Mazloomi;Bidgoli, Sepideh Arbabi
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.6
    • /
    • pp.2347-2350
    • /
    • 2015
  • Childhood acute lymphoblastic leukemia (ALL) is one of the most common hematologic malignancies, accounting for one fourth of all childhood cancer cases. Exposure to environmental factors around the time of conception or pregnancy can increase the risk of ALL in the offspring.This study aimed to evaluted the role of prenatal and postnatal exposure to high voltage power lines on the incidence of childhood ALL.This cross-sectional case control study was carried out on 22 cases and 100 controls who were born and lived in low socioeconomic families in Isfahan and hospitalized for therapeutic purposes in different hospitals from 2013-2014.With regard to the underlying risk factors, familial history and parental factors were noted but in this age, socioeonomic and zonal matched case control study, prenatal and childhood exposure to high voltage power lines was considered as the most important environmental risk factors of ALL (p=0.006, OR=3.651, CI 95%, 1.692-7.878). As the population was of low socioeconomic background, use of mobiles, computers and microwave was negligible. Moreover prenatal and postnatal exposure to indoor electrically charged objects was not determined to be a significant environmental factor. Thus, pre and post natal exposure to high voltage power lines and living in pollutant regions as well as familial influence could be described as risk factors of ALL for the first time in a low socioeconomic status Iranian population.