• Title/Summary/Keyword: Risk Mitigation Plan

Search Result 53, Processing Time 0.022 seconds

A Study on Risk Mitigation Measures of NaTech Damage Effect of Hazardous Chemical Storage Tank - Focus on Triggered by Earthquake - (화학물질 저장탱크의 NaTech 피해영향 저감방법 연구 - 지진으로 인한 사고 중심으로 -)

  • Lee, Tae-Hyung;Lee, Hyun-Seung;Yoo, Byung-Tae
    • Journal of the Korean Institute of Gas
    • /
    • v.22 no.5
    • /
    • pp.79-88
    • /
    • 2018
  • This study presents an evaluation method to estimate the damage scale of chemical storage tank of petrochemical plant due to the earthquake that is likely to occur among NaTech damage types. Based on this, the risk for damage reduction of chemical storage tanks was evaluated. As a result of the study, the risk of the storage tank increased greatly considering the earthquake, and the risk was greatly reduced as a result of evaluating the proposed measures to mitigate the damage impact on the earthquake. This study is expected to contribute to the research on the reduction of NaTech damages such as typhoons and thunderstorms as well as earthquakes, and to establish an emergency response plan. In the future, it is necessary to systematically study and institutionalize the risk reduction measures considering earthquakes.

Development of a Framework of Emergency Action Plan for Domestic Water Front Critical Infrastructure (국내 주요 수변시설물 EAP 프레임워크 개발)

  • Park, Su-Yeul;Choi, Soo-Young;Oh, Eun-Ho;Kim, Jin-Man
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.4
    • /
    • pp.125-134
    • /
    • 2017
  • Unusual precipitation caused by typhoons and severe rain stormscan threaten human life and property. Thus, various organizations prepare emergency action plans (EAPs) to provide proper guidelines for operators, experts, and emergency response personnel to protect and enhance critical infrastructure. For example, FEMA and DHS have various types of EAPs for dams, levees, and other structures to protect people and property. FEMA defines EAPs as official documents to decrease the damage and impact in emergency situations and to reduce casualties. These documents should consider all possible situations in an emergency and can reduce problems in facility management. This study analyzes EAPs for infrastructure from the USA, Japan, and Korea in order to suggest an ideal EAP framework. EAPcontent can include how to guide experts and operators in disaster stages (mitigation, preparedness, response, and recovery), how to operate emergency equipment, and how to protect critical infrastructure and life. The suggested EAP framework performed very well in a test location. It can therefore be used for infrastructure organizations in Korea and to inform of the appropriate processes and methods for risk reduction in flood disasters.

From Radon and Thoron Measurements, Inhalation Dose Assessment to National Regulation and Radon Action Plan in Cameroon

  • Saidou;Shinji Tokonami;Masahiro Hosoda;Augustin Simo;Joseph Victor Hell;Olga German;Esmel Gislere Oscar Meless
    • Journal of Radiation Protection and Research
    • /
    • v.47 no.4
    • /
    • pp.237-245
    • /
    • 2022
  • Background: The current study reports measurements of activity concentrations of radon (220Rn) and thoron (220Rn) in dwellings, followed by inhalation dose assessment of the public, and then by the development of regulation and the national radon action plan (NRAP) in Cameroon. Materials and Methods: Radon, thoron, and thoron progeny measurements were carried out from 2014 to 2017 using radon-thoron discriminative detectors (commercially RADUET) in 450 dwellings and thoron progeny monitors in 350 dwellings. From 2019 to 2020, radon track detectors (commercially RADTRAK) were deployed in 1,400 dwellings. It was found that activity concentrations of radon range in 1,850 houses from 10 to 2,620 Bq/㎥ with a geometric mean of 76 Bq/㎥. Results and Discussion: Activity concentrations of thoron range from 20 to 700 Bq/㎥ with a geometric mean of 107 Bq/㎥. Thoron equilibrium factor ranges from 0.01 to 0.6, with an arithmetic mean of 0.09 that is higher than the default value of 0.02 given by UNSCEAR. On average, 49%, 9%, and 2% of all surveyed houses have radon concentrations above 100, 200, and 300 Bq/㎥, respectively. The average contribution of thoron to the inhalation dose due to radon and thoron exposure is about 40%. Thus, thoron cannot be neglected in dose assessment to avoid biased results in radio-epidemiological studies. Only radon was considered in the drafted regulation and in the NRAP adopted in October 2020. Reference levels of 300 Bq/㎥ and 1,000 Bq/㎥ were recommended for dwellings and workplaces. Conclusion: Priority actions for the coming years include the following: radon risk mapping, promotion of a protection policy against radon in buildings, integration of the radon prevention and mitigation into the training of construction specialists, mitigation of dwellings and workplaces with high radon levels, increased public awareness of the health risks associated with radon, and development of programs on the scientific and technical aspects.

A Study on Regulation Improvement of Local Ventilation System (국소배기장치의 규제개선에 관한 연구)

  • kim, Nam Suk;Kim, Young Suk;Woo, In Sung
    • Journal of the Korean Institute of Gas
    • /
    • v.22 no.3
    • /
    • pp.74-83
    • /
    • 2018
  • Anyone who wants to install local ventilation system must obtain a permission from the Ministry of Employment and Labor even if he has permission from the Ministry of Environment. This is because not only the Atmospheric Environmental Protection Act, but also the manufacturing industry's hazardous risk prevention plan under Article 48 Clause 2 of the Industrial Safety and Health Act is to be submitted by 15 days before the construction. Under the current Environmental Protection Act, the Ministry of Environment regulates only the emission of pollutants from local exhaust ventilation systems into the atmosphere and the contents of workers' safety and health within industrial sites are managed by the Ministry of Employment and Labor. Even with the approval of the Ministry of Environment, the number of unsuccessful cases by the Ministry of Employment and Labor has increased, causing a growing discontent among the sites due to production delays and additional costs of improvement. In addition, local exhaust systems that are at greater risk of fire explosion have increased the risk of severe industrial accidents due to fire explosion. This is due to insufficient design of air volume, control speed, return speed, duct size, and risk of fire explosion. This is because the criteria and procedures for approval of local exhaust ventilation systems are similar, but the Industrial Safety and Health Act adds additional screening items for safety and safety of workers and fire and explosion. In this study, the Environment Ministry and the Employment and Labor Ministry seek to find a reasonable way to operate the system by comparing local exhaust ventilation system installation approval standards.

Development of the Simulator for FPC-G, the Focal Plane Fine Guiding Camera for SPICA

  • Pyo, Jeonghyun;Jeong, Woong-Seob;Lee, Chol;Kim, Son-Goo;Lee, Dae-Hee
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.38 no.1
    • /
    • pp.76.2-76.2
    • /
    • 2013
  • SPICA(SPace Infrared Telescope for Cosmology and Astrophysics) is an infrared space observatory with cooled telescope of 3 m aperture. Because of its large aperture, near- and mid-infrared instruments onboard SPICA require fine guidance with attitude accuracy less than 0.1 arcsecond. The FPC-G is a focal plane camera to achieve this high attitude accuracy and KASI is leading its development. The SPICA project is now under the Risk Mitigation Phase 2 (RMP2) and one of major risks is to satisfy the requirement of pointing and attitude control. To assess the impacts of disturbance sources on the attitude control and devise methods to mitigate possible risks, a software simulator of the FPC-G is under the development. In this presentation, we report the status of development of the simulator and the development plan during the RMP2.

  • PDF

THE NEXT-GENERATION INFRARED ASTRONOMY MISSION SPICA UNDER THE NEW FRAMEWORK

  • NAKAGAWA, TAKAO;SHIBAI, HIROSHI;ONAKA, TAKASHI;MATSUHARA, HIDEO;KANEDA, HIDEHIRO;KAWAKATSU, YASUHIRO
    • Publications of The Korean Astronomical Society
    • /
    • v.30 no.2
    • /
    • pp.621-624
    • /
    • 2015
  • We present the current status (as of August 2014) of SPICA (Space Infrared Telescope for Cosmology and Astrophysics), which is a mission optimized for mid- and far-infrared astronomy with a cryogenically cooled 3m-class telescope. SPICA is expected to achieve high spatial resolution and unprecedented sensitivity in the mid- and far-infrared, which will enable us to address a number of key problems in present-day astronomy, ranging from the star-formation history of the universe to the formation of planets. We have carried out the "Risk Mitigation Phase" activity, in which key technologies essential to the realization of the mission have been extensively developed. Consequently, technical risks for the success of the mission have been significantly mitigated. Along with these technical activities, the international collaboration framework of SPICA has been revisited, which resulted in la arger contribution from ESA than that in the original plan. To enable the ESA participation under the new framework, a SPICA proposal to ESA is under consideration as a medium-class mission under the framework of the ESA Cosmic Vision. The target launch year of SPICA under the new framework is the mid-2020s.

Parameter Optimization and Uncertainty Analysis of the Rainfall-Runoff Model (강우-유출모형 매개변수의 최적화 및 불확실성 분석)

  • Moon, Young-Il;Kwon, Hyun-Han
    • 한국방재학회:학술대회논문집
    • /
    • 2008.02a
    • /
    • pp.723-726
    • /
    • 2008
  • It is not always easy to estimate the parameters in hydrologic models due to insufficient hydrologic data when hydraulic structures are designed or water resources plan are established, uncertainty analysis, therefore, are inevitably needed to examine reliability for the estimated results. With regard to this point, this study applies a Bayesian Markov Chain Monte Carlo scheme to the NWS-PC rainfall-runoff model that has been widely used, and a case study is performed in Soyang Dam watershed in Korea. The NWS-PC model is calibrated against observed daily runoff, and thirteen parameters in the model are optimized as well as posterior distributions associated with each parameter are derived. The Bayesian Markov Chain Monte Carlo shows a improved result in terms of statistical performance measures and graphical examination. The patterns of runoff can be influenced by various factors and the Bayesian approaches are capable of translating the uncertainties into parameter uncertainties. One could provide against an expected runoff event by utilizing information driven by Bayesian methods. Therefore, the rainfall-runoff analysis coupled with the uncertainty analysis can give us an insight in evaluating flood risk and dam size in a reasonable way.

  • PDF

A Study on the Risk Assessment and Mitigation Plan about Fire Explosion of n-Pentane in EPS Process (EPS공정에서 발생하는 n-Pentane의 화재폭발에 대한 위험성평가 및 위험성 완화 대책에 관한 연구)

  • Seo, Min Su;Kim, Ki Sug;Kim, Bo Min;Kang, Dong Cheon;Kang, Kil Jae;Chon, Young Woo
    • Korean Journal of Hazardous Materials
    • /
    • v.6 no.2
    • /
    • pp.39-46
    • /
    • 2018
  • 최근 전자제품 생산업체에서 EPS를 직접생산하게 되면서 EPS 공정이 증가하고 있다. EPS에는 펜탄이 포함되어 있으며, 펜탄은 하이브리드 혼합물로 구분할 수 있어 높은 화재폭발의 위험성을 가지고 있다. 각 공정별 펜탄의 누출률은 발포기, 사일로실, 저장실 순이나 발포기의 경우 일반적으로 밀폐되어 있으므로 사일로 실이 가장 화재폭발 위험성이 높다고 판단하였다. 사일로실의 누출률 중 70%는 사일로 상단을 통해 누출되며, 사일로 상단을 통해 누출되는 펜탄의 거동을 분석하여 사일로실 위험성 완화대책을 수립하였다. 1. 폭발위험구역 2종으로 관리, 2. 사일로상단 50cm이내 환기설비 설치 또는 Push-Pull 구조의 환기설비설치, 3. 사일로 하단 1.4m이내에 가스감지기 설치, 4. 60%이상의 습도유지

Assessment of Extreme Wind Risk for Window Systems in Apartment Buildings Based on Probabilistic Model (확률 모형 기반의 아파트 창호 시스템 강풍 위험도 평가)

  • Ham, Hee Jung;Yun, Woo-Seok;Choi, Seung Hun;Lee, Sungsu;Kim, Ho-Jeong
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.28 no.6
    • /
    • pp.625-633
    • /
    • 2015
  • In this study, a coupled probabilistic framework is developed to assess wind risk on apartment buildings by using the convolution of wind hazard and fragility functions. In this framework, typhoon induced extreme wind is estimated by applying the developed Monte Carlo simulation model to the climatological data of typhoons affecting Korean peninsular from 1951 to 2013. The Monte Carlo simulation technique is also used to assess wind fragility function for 4 different damage states by comparing the probability distributions of the window system's resistance performance and wind load. Wind hazard and fragility functions are modeled by the Weibull and lognormal probability distributions based on simulated wind speeds and failure probabilities. The modeled functions are convoluted to obtain the wind risk for the different damage levels. The developed probabilistic framework clearly shows that wind risk are influenced by various important characteristics of terrain and apartment building such as location of building, exposure category, topographic condition, roof angle, height of building, etc. The risk model presented in this paper can be used as tools to predict economic loss estimation and to establish wind risk mitigation plan for the existing building inventory.

An analysis study for reasonable installation of tunnel fire safety facility (터널 방재설비의 합리적 설치를 위한 분석적 연구)

  • Park, Jin-Ouk;Yoo, Yong-Ho;Park, Byoung-Jik
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.17 no.3
    • /
    • pp.243-248
    • /
    • 2015
  • Domestic road and railroad construction have been increasingly growing and for reasons of mitigating traffic congestion, urban plan and refurbishment project, deeper and longer tunnels have been built. The event of fire is the most fatal accident in a tunnel, and it can be very disastrous with a high possibility. In this study, QRA (Quantitative Risk Analysis) which is one of quantitative risk analysis approaches was applied to tunnel fire safety design and the evaluation of QRA cases and the cost comparison of QRA methods were carried out. In addition analysis of risk reduction effect of tunnel fire safety system was conducted using AHP (Analytic Hierarchy Process) and the priority of major factors that could mitigate the risk in tunnel fire was presented. As a result, significant cost reduction effect could be obtained by incorporating QRA and it is expected to design fire safety system rationally. The priority of fire safety system based on risk mitigation effect by fire safety system considering the cost is in order of water pipe, emergency lighting, evacuation passage and smoke control system.