• 제목/요약/키워드: Rise ratio

검색결과 1,048건 처리시간 0.024초

3경간 연속 중로식 강Arch 교량의 내풍안정성을 고려한 Rise 비 (Rise Ratio of the 3 Continuous Spans Half Through Steel Arch Bridges Considering Wind Resistant Dynamic Stability)

  • 강성후;박선준;최명기
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2004년도 가을 학술발표회 논문집
    • /
    • pp.76-83
    • /
    • 2004
  • The most important element is a rise ratio when regarding beauty and economics of arch bridges. Only the effect of dead load has been considered to decide the rise ratio. In this study, when going over the rise ratio of arch bridges, examined the problems, that the determination of the rise ratio by the dead load has, by adding the factor of a determination of optimum rise ratio, which is not only the effect of the dead load that has been currently considered but also the problem with respect to wind resistant dynamic stability that is now taken seriously. Synthetically, when deciding rise ratio that is investigated in basic step of design, it is not necessary to consider the evaluation wind resistant dynamic stability.

  • PDF

동적안정성을 고려한 3경간 연속 중로식 강 Arch 교량의 Rise 비 (The Rise Ratio of the 3 Continuous Span Length Steel Arch Bridges Considering Dynamic Stability)

  • 강성후;박선준;최명기
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제8권4호
    • /
    • pp.175-183
    • /
    • 2004
  • 아치교량의 미관과 경제성을 고려할 때 가장 중요한 요소가 라이즈 비 이며, 이러한 라이즈 비를 결정하는데 있어 현재는 자중에 의한 영향만을 고려하고 있다. 본 연구에서는 아치교량의 라이즈 비 검토시 현재 고려하고 있는 자중에 의한 영향뿐만 아니라 최근 중요시 되고 있는 지진하중에 대한 동적안정성 문제를 라이즈 비 결정인자로 추가하여 자중에 의한 라이즈 비 결정이 가지고 있는 문제점에 대하여 검토하였다. 그 결과 라이즈 비 선정시 지진하중에 대한 동적안정성은 필히 고려되어야 할 것으로 판단되었다.

라이즈-스팬 비에 따른 개폐식 돔 지붕의 외장재 설계용 피크순압력계수 (Peak Net Pressure Coefficients for Cladding Design of Retractable Dome Roofs according to Rise-Span Ratio)

  • 천동진;김용철
    • 한국공간구조학회논문집
    • /
    • 제24권2호
    • /
    • pp.101-109
    • /
    • 2024
  • In this study, the characteristics of wind pressure distribution on circular retractable dome roofs with a low rise-to-span ratio were analyzed under various approaching flow conditions by obtaining and analyzing wind pressures under three different turbulent boundary layers. Compared to the results of previous studies with a rise-to-span ratio of 0.1, it was confirmed that a lower rise-to-span ratio increases the reattachment length of the separated approaching flow, thereby increasing the influence of negative pressure. Additionally, it was found that wind pressures varied significantly according to the characteristics of the turbulence intensity. Based on these experimental results, a model for peak net pressure coefficients for cladding design was proposed, considering variations in turbulence intensity and height.

라이즈비를 고려한 닐센아치교의 형상 거동에 관한 연구 (The Study on Shape Behavior of Nielsen Arch Bridge Considering Rise Ratio)

  • 박순응;박문호;김진규;노우혁;조성욱;류지영
    • 한국산업융합학회 논문집
    • /
    • 제13권3호
    • /
    • pp.161-168
    • /
    • 2010
  • Recently, bridges have been momenttous as not only regarding function but also concerning aesthetics. However, when beauty is considered in the bridge, it is also essential that stability and economics be considered. Besides, when considering stability, an arch bridge is one of the most stable structures. The most important element is a rise ratio when regarding beauty and economics of arch bridges. The effect of dead load and DB24 load have been considered to decide proper rise ratio. Therefore, in this study, examined the value of moment, displacement and member forces, in the variation of the rise ratio of arch bridges. The most optimum shape of Nielsen arch bridges has determined by analyzing member forces, moments and displacement with parameters of rise ratio and angle of vertical members. By comparison between values, the hanger types have been also considered to derive the optimum shape of Nielsen arch bridge.

  • PDF

이송되는 컵 내부의 자유 표면의 거동 특성에 대한 수치해석 (A Numerical Analysis of the Behavior of the Free Surface in a Moving Cup)

  • 홍태협;채희문;김창녕
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회B
    • /
    • pp.2997-3002
    • /
    • 2007
  • A manipulator is operated for the motion of mechanical hands or arms by mechanical mechanism. When a cup including liquid inside is shifted by a manipulator, it is important to know how a free surface of the liquid moves. In this study, non-dimensional parameters have been found that affect the rise of the free surface in a cup moving with constant acceleration. The non-dimensional parameters are the dimensionless time, the ratio of inertia effect to vicous effect (Reynolds number), aspect ratio of the liquid inside the cup and acceleration ratio (Froude number). Through this study, the height of the free surface rise in a cup has been predicted. Generally the maximum rise of the free surface is dependent on the Reynolds number and Froude number strongly, but on the aspect ratio weakly. But the influence of the aspect ratio on the maximum rise of the free surface in not negligible in the range 10 < Re < 100.

  • PDF

디젤기관에 있어서 에멀젼 연료가 연소특성에 미치는 영향 (Effects on the Characteristics of Combustion by using Emulsion Fuel in Diesel Engine)

  • 임재근;조상곤;황상진;유동훈;서장원
    • 한국마린엔지니어링학회:학술대회논문집
    • /
    • 한국마린엔지니어링학회 2006년도 전기학술대회논문집
    • /
    • pp.41-42
    • /
    • 2006
  • A study on the combustion characteristics by using Emulsion Fuel in Diesel Engine is performed experimentally. In this paper, the experiments are performed at engine speed 1800rpm, emulsion fuel ratio is 0%, 10%, 20%, and main measured items are specific fuel consumption, pressure, ratio of pressure rise, rate of heat release etc. The obtained conclusions are as follows. 1) Specific fuel consumption increase maximum 19.8% at low load, but is not effected at full load. 2) Ratio of pressure rise and rate of heat release are about the same in the case of 10% and 20% of emulsion fuel ratio. 3) Cylinder Pressure increase 11.7%, ratio of pressure rise increase 60.4% in case of emulsion fuel ratio 20% at full load. 4) Rate of heat release increase 76.9% in case of emulsion fuel ratio 20% at full load.

  • PDF

면진장치 설치각도에 따른 아치구조물의 지진응답 (Seismic Response of Arch Structure with Base Isolation Device Depending on Installation Angle)

  • 김기철;이준호
    • 한국공간구조학회논문집
    • /
    • 제22권1호
    • /
    • pp.25-32
    • /
    • 2022
  • The seismic behaviors of the arch structure vary according to the rise-span ratio of the arch structure. In this study, the rise-span ratio (H/L) of the example arch structure was set to 1/4, 1/6, and 1/8. And the installation angle of the seismic isolator was set to 15°, 30°, 45°, 60° and 90°. The installation angles of the seismic isolator were set by analyzing the horizontal and vertical reaction forces according to the rise-span ratio of the arch structure. Due to the geometrical and dynamic characteristics of the arch structure, the lower the rise-span ratio, the greater the horizontal reaction force of the static load, but the smaller the horizontal reaction force of the dynamic load. And if the seismic isolator is installed in the direction of the resultant force of the reaction forces caused by the seismic load, the horizontal seismic response becomes small. Also, as the installation angle of the seismic isolator increases, the hysteresis behavior of the seismic isolator shows a plastic behavior, and residual deformation appears even after the seismic load is removed. In the design of seismic isolators for seismic response control of large space structures such as arch structures, horizontal and vertical reaction forces should be considered.

디젤기관에 있어서 에멀젼연료 연소특성에 미치는 영향 (Effects of Emulsified Fuel on Combustion Characteristics in a Diesel Engine)

  • 임재근;조상곤;황상진;유동훈
    • 동력기계공학회지
    • /
    • 제11권1호
    • /
    • pp.51-55
    • /
    • 2007
  • A study on combustion characteristics using emulsified fuel in a diesel engine were performed experimentally. In this paper, the experiments were performed at engine speed 1800rpm, emulsion ratios were 0%, 10%, 20%, and main measured items were specific fuel consumption, cylinder pressure, rate of pressure rise, rate of heat release etc. The obtained conclusions were as follows. 1) Specific fuel consumption increased maximum by 19.8% at low load, but was not affected at full load. 2) Rate of pressure rise and rate of heat release were about the same in the case of 10% and 20% of emulsion ratio. 3) Cylinder Pressure increased 9.6%, rate of pressure rise increased 53.4% in case of emulsion ratio 20% at full load. 4) Rate of heat release increased 72.4% in case of emulsion ratio 20% at full load.

  • PDF

대만의 남아선호와 출생시 성비의 불균형 (Sex Preference and Sex Ratio at Birth: the Case of Taiwan)

  • Chang, Ming-cheng
    • 한국인구학
    • /
    • 제17권2호
    • /
    • pp.98-115
    • /
    • 1994
  • This study is attempting to examine the possible determinants of the rise of the sex ratio at birth from 106 to 110 in past decade in Taiwan. The basic hypothesis for the sudden rise of the sex ratio at birth is due to a combination of prenatal sex determination and abortion. The reasoning for this hypothesis involves three types of considerations - motivation, norm, and access. The theory is evaluated by analyzing data from birth registration and a large and representative sampie of Taiwanese wives of childbearing age. The empirical data seem to support the theoretical preposition and the basic hypothesis that the rise of the sex ratio at birth in Taiwan is due to a combination of prenatal sex determination and abortion. There is striking evidence of son-preference in the rise of the sex ratio at birth in higher birth order. In 1990 the sex ratio was 119 for third births and 128 for fourth and fifth births compared to the expected 106. Also, the 1991 KAP data indicated that women who have only daughters but no any son are more likely to make prenatal sex screening and terminate their pregnancies in male live births at higher birth order. Obviously, genetic diagnosis through chorionic villus sampling which was available in recent years was misused for prenatal sex determination and sex selective abortion.

  • PDF

중심코어를 가지는 저층 철근콘크리트 필로티 건물의 내진성능 (Seismic Performance of Low-rise Piloti RC Buildings with Concentric Core)

  • 윤태호
    • 한국산업융합학회 논문집
    • /
    • 제25권4_2호
    • /
    • pp.611-619
    • /
    • 2022
  • In this study, the seismic performance of low - rise piloti buildings with concentric core (shear wall) position is analysed and reviewed based on KDS 41. The prototype is selected among the constructed low - rise piloti buildings with concentric core designed based on KBC 2005 which was used for many low - rise piloti buildings construction. The seismic performance of the building shows plastic behavior in X-direction and elastic behavior in Y-direction. The inter-story drift is lager than that of concentric core case and is under the maximum allowed drift ratio. The displacement ratio of first story is much lager the that of upper stories, and the frame structure in the first story is evaluated as vulnerable to lateral force. Therefore, low - rise piloti buildings with concentric core need the diminishment of lateral displacement and reinforcement of lateral resistance capacity in seismic design and seismic retrofit.