• Title/Summary/Keyword: Ripple power

Search Result 1,035, Processing Time 0.035 seconds

The Design and Reliability Evaluation of Metallized Film Capacitor for Power Electronic Applications (전력전자용 금속증착 필름 커패시터 설계 및 신뢰성 평가)

  • Yoon, Jung-Rag;Kim, Young-Kwang;Lee, Serk-Won;Lee, Heun-Young
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.24 no.5
    • /
    • pp.381-386
    • /
    • 2011
  • This paper presents the design and reliability evaluation of metallized film capacitor for power e lectronics application. The rated voltage of development capacitor is DC 3300[V], the capacitance is 5 ${\mu}F$ and the ripple current capability is 130 $A_{rms}$. Film metallization and patterns are an important design factor that has been development enhance the electric and reliability properties of film capacitor for power electronics. In term of capacitor construction and metallized pattern is one of the parameters that can be modified to further improve the rating in the terms of maximum ripple current and lifetime. This capacitor can be used as snubber capacitor application such as power train invertor system.

A Novel Input and Output Harmonic Elimination Technique for the Single-Phase PV Inverter Systems with Maximum Power Point Tracking (최대출력추종 제어를 포함한 단상 태양광 인버터를 위한 새로운 입출력 고조파 제거법)

  • Amin, Saghir;Ashraf, Muhammad Noman;Choi, Woojin
    • Proceedings of the KIPE Conference
    • /
    • 2019.07a
    • /
    • pp.207-209
    • /
    • 2019
  • This paper proposes a grid-tied photovoltaic (PV) system, consisting of Voltage-fed dual-active-bridge (DAB) dc-dc converter with single phase inverter. The proposed converter allows a small dc-link capacitor, so that system reliability can be improved by replacing electrolytic capacitors with film capacitors. The double line frequency free maximum power point tracking (MPPT) is also realized in the proposed converter by using Ripple Correlation method. First of all, to eliminate the double line frequency ripple which influence the reduction of DC source capacitance, control is developed. Then, a designing of Current control in DQ frame is analyzed and to fulfill the international harmonics standards such as IEEE 519 and P1547, $3^{rd}$ harmonic in the grid is directly compensated by the feedforward terms generated by the PR controller with the grid current in stationary frame to achieve desire Total Harmonic Distortion (THD). 5-kW PV converter and inverter module with a small dc-link film capacitor was built in the laboratory with the proposed control and MPPT algorithm. Experimental results are given to validate the converter performance.

  • PDF

Interleaved High Step-Up Boost Converter

  • Ma, Penghui;Liang, Wenjuan;Chen, Hao;Zhang, Yubo;Hu, Xuefeng
    • Journal of Power Electronics
    • /
    • v.19 no.3
    • /
    • pp.665-675
    • /
    • 2019
  • Renewable energy based on photovoltaic systems is beginning to play an important role to supply power to remote areas all over the world. Owing to the lower output voltage of photovoltaic arrays, high gain DC-DC converters with a high efficiency are required in practice. This paper presents a novel interleaved DC-DC boost converter with a high voltage gain, where the input terminal is interlaced in parallel and the output terminal is staggered in series (IPOSB). The IPOSB configuration can reduce input current ripples because two inductors are interlaced in parallel. The double output capacitors are charged in staggered parallel and discharged in series for the load. Therefore, IPOSB can attain a high step-up conversion and a lower output voltage ripple. In addtion, the output voltage can be automatically divided by two capacitors, without the need for extra sharing control methods. At the same time, the voltage stress of the power devices is lowered. The inrush current problem of capacitors is restrained by the inductor when compared with high gain converters with a switching-capacitor structure. The working principle and steady-state characteristics of the converter are analyzed in detail. The correctness of the theoretical analysis is verified by experimental results.

Current Reference Calculation for Distribution Static Compensator using Phase Shift (위상변이를 이용한 배전용 정지형 보상기의 전류 지령 계산)

  • Hong, Sung-Min;Choi, Jong-Woo
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.17 no.1
    • /
    • pp.41-47
    • /
    • 2012
  • This paper proposes a calculation of compensation current using phase shift to eliminate ripple components of instantaneous active power under unbalanced or non-linear loads condition. The proposed phase shift method instead of existing method(LPF; Low Pass Filter) to remove ripple components and this proposed method improves performances of transient and steady state response. To compare proposed method with existing method, experiments have been done for calculating an average active power at load side. Their results show that transient response and steady state response of proposed method is improved.

Design and Analysis of High-order Active Input Filter for Power Factor Correction(PFC) Converter (역률 개선 컨버터용 고차 능동 필터의 설계 및 분석)

  • Lee, Dong-Young;Cho, Bo-Hyung
    • Proceedings of the KIEE Conference
    • /
    • 1996.07a
    • /
    • pp.259-261
    • /
    • 1996
  • In this paper, active input filter for power factor correction(PFC) circuit employing ripple arrent and voltage cancellation is proposed to reduce filter's size and cost, and to make filter design easy. Switching ripple current and voltage can be sensed through the secondary windings of filter inductor. Single stage passive filter can achieve high order filter characteristics by using active ripple current and voltage cancellation technique. Conventional high order passive filter and its problems are suggested. Analysis of active filter and design procedure are detailed. Simulation result is presented to verify high order filter characteristics of proposed scheme.

  • PDF

DC Link Currents in Frequency Domain for Three-Phase AC/DC/AC PWM Converters

  • Park Young-Wook;Lee Dong-Choon;Seok Jul-Ki
    • Proceedings of the KIPE Conference
    • /
    • 2001.10a
    • /
    • pp.169-173
    • /
    • 2001
  • In this paper, dc link ripple currents for three-phase ac/dc/ac PWM converters are ana lysed in a frequency domain. The expression of the harmonic currents is developed by using switching functions and exponential Fourier series expansion. The dc link ripple currents with regard to power factor and modulation index are investigated. In addition, the effect of the displacement angle between the switching periods of line-side converters and load-side inverters on the dc link ripple current is studied. The result of the dc link current analysis is helpful in specifying the dc link capacitor size and its lifetime estimation.

  • PDF

Improvement of Torque Ripple Using Compensation for the Phase Delay of Winding Inductance on Brushless DC Motor (상 권선 인덕턴스의 위상지연 보상에 의한 브러시리스 직류 전동기의 토크 리플 개선)

  • 유시영;이두수
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.6 no.2
    • /
    • pp.180-190
    • /
    • 2001
  • In this paper, a method of reducing torque ripples caused by phase winding inductances in BLDCM(Brushless DC Motor) drives is presented. In order to compensate the inductive current delays, commutation angle is controlled by the value compensating angle varied in accordance with rotational speed. Using the microprocessor AVR 8515, the proposed compensator is implemented and experiments are done with a 4-pole 3-phase BLDCM. The results show the remarkable reduction of torque ripple at whole speed ranges.

  • PDF

2-Phase Bidirectional Non-Inverting Buck-Boost Converter using Coupled Inductor (결합 인덕터를 이용한 2상 양방향 비반전 벅-부스트 컨버터)

  • Chae, Jun-Young;Jeong, Seung-Yong;Cha, Hon-Nyong;Kim, Heung-Geun
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.19 no.6
    • /
    • pp.481-487
    • /
    • 2014
  • This study proposes a two-phase non-inverting buck-boost converter that uses a coupled inductor. The multi-phase converter has many advantages over single-phase counterparts, such as reduced output current ripple and conduction loss in switching devices and passive elements. Although the output current ripple of the multi-phase converter is reduced significantly because of the interleaved effect, the inductor current ripple is not reduced in multi-phase converters. One of the solutions to this problem is to use a coupled inductor. A 4 kW prototype converter is built and tested to verify the performance of the proposed converter.

Measurement of Hydraulic Pump Flow Ripple Characteristics Based on the ISO 10767-1 and the Evaluation of the Measuring Accuracy (ISO 10767-1에 기초한 유압 펌프의 유량 맥동 측정 및 정밀도 평가)

  • Kim, J.W.;Kang, M.G.;Lee, I.Y.
    • Transactions of The Korea Fluid Power Systems Society
    • /
    • v.4 no.3
    • /
    • pp.22-27
    • /
    • 2007
  • The source flow ripple and the source impedance in hydraulic pump are characteristic values showing fluid-borne vibration characteristics decisively. We cannot measure these two characteristic values directly, but can measure them by some indirect methods. One representative indirect measuring method is ISO 10767-1. The authors constructed a hardware and a software for the measuring method based on ISO 10767-1. Through the error evaluation of the measured results, accuracy of the measuring method using ISO 10767-1 was examined in detail.

  • PDF

Zero-Current Switching Two-Transformer Phase-Shift Full-Bridge Converter using Voltage Ripple (전압 리플을 이용해 영전류스위칭하는 두개의 트랜스포머를 가지는 위상천이 풀-브릿지 컨버터)

  • Yoon, Hyun-Ki;Moon, Gun-Woo;Youn, Myung-Joong
    • Proceedings of the KIPE Conference
    • /
    • 2005.07a
    • /
    • pp.436-438
    • /
    • 2005
  • This paper presents a Zero-Current Switching(ZCS) two-transformer phase-shift full-bridge(TTFB) converter using voltage ripple. The proposed converter provides Zero-Voltage Switching(2VS) of leading leg switches and ZCS of lagging leg switches using volt-age ripple. Especially, circulating current Is reduced by ZCS operation and there are no additional components required for the soft switching of power switches. Furthermore, in case of light load, ZVS operation of lagging leg can be achieved. The operations, analysis and design consideration of proposed converter are presented. To verify the validity of the proposed converter, experimental results for a flow (205V, 2A) prototype are presented.

  • PDF