• Title/Summary/Keyword: Ring test

Search Result 769, Processing Time 0.03 seconds

Novel pH/Temperature Sensitive Hydrogels of Poly (ethylene glycol)-Poly (caprolactone) -Poly (${\beta}-amino\;ester$) (PAE-PCLA-PEGPCLA-PAE) Biodegradable Polyester Block Copolymer

  • Huynh Dai Phu;Lee Doo-Sung
    • Proceedings of the Polymer Society of Korea Conference
    • /
    • 2006.10a
    • /
    • pp.263-263
    • /
    • 2006
  • Poly (ethylene glycol)(PEG) - Poly (${\varepsilon}-caprolactone(CL)$) - Poly (D,L lactide(LA) (PCLA-PEG-PCLA) was synthesized by ring-opening polymerization to form temperature sensitive hydrogel triblock copolymer. The triblock copolymer was acrylated by acryloyl chloride. ${\beta}-amino$ ester was used as a pH sensitive moiety, in this study ${\beta}$- amino ester obtained from 1,4-butandiol diacrylate, and 4, 4' trimethylene dipiperidine, it have pKb around 6.6. pH/temperature sensitive penta-block copolymer (PAE-PCL-PEG-PCL-PAE) was synthesized by addition polymerization from acrylated triblock copolymer, 1,4-butandiol diacrylate, and 4, 4' trimethylene dipiperidine. Their physicochemical properties of triblock and penta-block copolymers were characterized by $^1H-NMR$ spectroscopy and gel permeation spectroscopy. Sol-gel phase transition behavior of PAE-PCL-PEG-PCL-PAE block copolymers were investigated by remains stable method. Aqueous media of the penta-block copolymer (at 20 wt%) changed from a sol phase at pH 6.4 and $10^{\circ}C$ to a gel phase at pH 7.4 and $37^{\circ}C$. The sol-gel transition properties of these block copolymers are influenced by the hydrophobic/hydrophilic balance of the copolymers, block length, hydrophobicity, stereo-regularity of the hydrophobic of the block copolymer, and the ionization of the pH function groups in the copolymer depended on the changing of environmental pH, respectively. The degradation and the stabilization at pH 7.4 and $37^{\circ}C$, and the stabilization at pH 6.4 and $10^{\circ}C,\;5^{\circ}C,\;0^{\circ}C$, of the gel were determined. The results of toxicity experiment show that the penta block copolymer can be used for injection drug delivery system. The sol?gel transition of this block copolymer also study by in vitro test ($200{\mu}l$ aqueous solution at 20wt% polymer was injected to mouse). Insulin loading and releasing by in vitro test was investigated, the results showed that insulin can loading easily into polymer matrix and release time is around 14-16days. The PAE-PCL-PEG-PCL-PAE can be used as biomaterial for drug, protein, gene loading and delivery.

  • PDF

Evaluation of Shrinkage Cracking Characteristics and Degree of Restraint for Ultra-High-Strength Concrete (초고강도 콘크리트의 수축 균열 특성 및 구속도 평가)

  • Yoo, Doo-Yeol;Min, Kyung-Hwan;Yang, Jun-Mo;Yoon, Young-Soo
    • Journal of the Korea Concrete Institute
    • /
    • v.22 no.5
    • /
    • pp.641-650
    • /
    • 2010
  • The concrete cracking from the restrained stress caused by the shrinkage may play significant cause of deterioration of concrete structures by allowing the permeation of sulphate and chloride ions which in turn triggers corrosion of steel reinforcement. In particular, the cracking becomes more critical as water binder ratio (W/B) is reduced and concrete strength increases. Therefore, it needs to evaluate correctly the comprehensive shrinkage behavior of concrete with high strength: high-strength concrete (HSC), ultra-highstrength concrete (UHSC). The unrestrained shrinkage tests, however, cannot estimate the net shrinkage effectively which affects cracking after full development of strength and stiffness because it does not consider the degree of restraint, strength development, stress relaxation, and so on. Therefore, in this study, both free and restrained shrinkage tests with variables of W/B (W/B of 30, 25 and 16%) and admixtures (fly ash (FA) and granulated blast-furnace slag (BFS)) for HSC, very-high-strength concrete (VHSC) and UHSC were performed. The test results indicated that the autogenous shrinkage and total shrinkage at drying condition were reduced as W/B increased and FA, BFS were added, and the cracking behavior was suppressed as W/B increased and FA was added.

A Study on the Analysis of the Resistance Characteristics and Damage Patterns of Brass Fittings Type CSST (황동이음쇠형 금속플렉시블호스(CSST)의 저항 특성 및 소손 패턴 해석에 관한 연구)

  • Lee, Jang-Woo;Choi, Chung-Seog
    • Fire Science and Engineering
    • /
    • v.30 no.5
    • /
    • pp.67-73
    • /
    • 2016
  • This paper examined the structure, fire resistance of brass fittings type CSST employed in gas appliances and the reliability verification. Brass fittings of type CSST consisted of cladding, tubing, nut, clamp ring, socket, and ball valve. The applicable JIA standard regulates the maximum working pressure to be 4.2 kPa, which is the highest pressure of the relevant standards and the KS D 3625 stipulates the maximum pressure to be 3.24 kPa. With a normal product, the average resistance within the confidence interval was found to be $7.36m{\Omega}$. The average resistance within the confidence interval was $6.67m{\Omega}$ after the fire resistance tests. The analysis indicated that the AD was 1.584 and the standard deviation was 0.3972 with respect of a normal product. Compared to the normal product, however, the damaged product after the fire resistance test showed better features, such as an AD of 1.145 and a standard deviation of 0.2467. Moreover, the average resistance of the normal product was $7.359m{\Omega}$ and the standard deviation in histogram analysis was 0.3972. The average resistance of the damaged product after the fire resistance test in the histogram was $6.67m{\Omega}$ and the standard deviation was 0.2467.

Bioequivalence Evaluation of Lovastatin Tablets (로바스타틴 정제의 생물학적 동등성 평가)

  • Bok, Hae Sook;Kim, Myoung Min;Choi, Kyung Eob
    • Korean Journal of Clinical Pharmacy
    • /
    • v.8 no.2
    • /
    • pp.107-112
    • /
    • 1998
  • Lovastatin is a lipid lowering agent for the treatment of hypercholesterolemia and belongs to a new class of pharmacologic compounds called the 3-hydroxy-3-methylglutaryl coenzyme A (HMG CoA) reductase inhibitors. By competitively inhibiting HMG CoA reductase, lovastatin disrupts the biosynthesis of cholesterol in hepatic and peripheral cells and increases the synthesis of high-density-lipoprotein HDL) receptors. Following oral administration, the lactone ring of lovastatin is hydrolysed to the active inhibitor of HMG CoA reductase, lovastatin acid. Lovastatin is known to have poor oral absorption and wide individual variation. In this study, bioequivalence test of two lovastatin formulations, the test drug ($Lovaload^{TM}$, Chong Kun Dang Pharmaceutical Co.) and the reference drug ($Mevacor^{TM}$, Chung Wae Pharmaceutical Co.) were conducted according to the guidelines of Korea Food and Drug Administration (KFDA). A total of 18 healthy male volunteers, $31.90\pm3.60$ years old and $72.17\;7.88$ kg of body weight in average, were evaluated in a randomized crossover manner with a 2-week washout period. Concentrations of lovastatin acid in plasma were measured upto 12 hours following a single oral administration of eight tablets (20 mg of lovastatin per tablet) by high-performance liquid chromatography with UV detection at 238 nm. The area under the concentration-vs-time curve from 0 to 12 hours $(AUC_{0-12h})$ was calculated by the trapezoidal summation method. The statistical analysis showed that there are no significant differences in $AUC_{0-12h),\;C_{max}\;and\;T_{max}$ between the two formulations ($6.72\%,\;1.52\%,\;and\;0.88\$, respectively). The least significant differences between the formulations at $\alpha$=0.05 were less than $20\%\;(11.65\%,\;19.73\%,\;and\;14.81\%\;for\;AUC_{0-12h},\;C_{max}\;and\;T_{max}$, respectively). The $90\%$ confidence intervals for these parameters were also within $\pm20\%\;(-1.50{\leq}{\delta}{\leq}15.00$, $-12.50{\leq}{\delta}{\leq}15.50,\;and\;-9.64{\leq}{\delta]{\leq}11.40{\leq}\;for\;\;AUC_{0-12h}$ ,$C_{max}\;and\;T_{max}$, respectively). In conclusion, the new generic product $Lovaload^{TM}$ was proven to be bioequivalent with the reference drug.

  • PDF

Synthesis and characterization of PPG-based urethane-modified epoxy resin for enhancing impact resistance of epoxy composite resin (에폭시 복합수지의 내충격성을 향상을 위한 PPG 기반 우레탄 변성 에폭시 합성 및 특성 분석)

  • Hwang, Chiwon;Jeon, Jaehee;Ahn, Dowon;Yu, Youngchang;Lee, Wonjoo
    • Journal of Adhesion and Interface
    • /
    • v.23 no.2
    • /
    • pp.44-52
    • /
    • 2022
  • Epoxy resin has the disadvantage of being easily destroyed by instantaneous impact due to its high crosslinking density despite its high glass transition temperature (Tg) and excellent properties. To compensate for this, in this study, polyol was synthesized by ring opening polymerization of propylene glycol (PPG) diamine, Jeffamine D 2000 and propylene carbonate, and urethane modified epoxy was synthesized using this. The properties of the synthesized urethane modified epoxy were confirmed by FT-IR, H-NMR. To confirm the degree of improvement in impact resistance as an adhesive, a urethane modified epoxy adhesive was prepared by mixing a digylcidyl ether bisphenol A (DGEBA) with curing agent and curing accelerator. Properties test of urethane modified epoxy were shear strength, tensile strength and impact strength. As a result, excellent results were obtained in all test when the ratio of DGEBA : urethane modified epoxy was 8:2.

Strength Properties of Wooden Model Erosion Control Dams Using Domestic Pinus rigida Miller I (국내산 리기다소나무를 이용한 목재 모형 사방댐의 강도 성능 평가 I)

  • Kim, Sang-Woo;Park, Jun-Chul;Lee, Dong-Heub;Son, Dong-Won;Hong, Soon-Il
    • Journal of the Korean Wood Science and Technology
    • /
    • v.36 no.6
    • /
    • pp.77-87
    • /
    • 2008
  • Wooden model erosion control dam was made with pitch pine, of which the strength properties was evaluated. Wooden model erosion control dam was made with diameter 90 mm of pitch pine round posts treated with CUAZ-2 (Copper Azole), changing joint in three different types. In each type, erosion control dam was made in nine floor (cross-bar of five floors and vertical-bar of four floors), of which the hight was 790 mm. And then strength properties were investigated through horizontal loading test and impact strength test, and the deformation of structure through image processing (AICON 3D DPA-PRO system). In horizontal loading test of wooden model erosion control dam using round post of diameter 90 mm, whether there was stone or not did not affect strength much when using self drill screw, but strength was decreased by 23%. In monolithic type of erosion control dam using screw bar, strength was increased by 1.5 times and deformation was decreased when filling with stone. When reinforcing with screw bar that ring is connected to self drill screw, strength was increased by 4.8 times. In impact strength test of wooden model erosion control dam made with round post of diameter 90 mm, the erosion control dam connected with self drilling screw not filling with stone was totally destroyed by the 1st impact, and the erosion control dam using screw bar was ruptured at cross-bar at which 779 kgf of impact was loaded in the 1st impact. In the 2nd impact, the base parts were ruptured, and reaction force was decreased to 545 kgf. In the 3rd impact, whole base parts were destroyed, and reaction force was decreased to 263 kgf.

Development of a Small Animal Positron Emission Tomography Using Dual-layer Phoswich Detector and Position Sensitive Photomultiplier Tube: Preliminary Results (두층 섬광결정과 위치민감형광전자증배관을 이용한 소동물 양전자방출단층촬영기 개발: 기초실험 결과)

  • Jeong, Myung-Hwan;Choi, Yong;Chung, Yong-Hyun;Song, Tae-Yong;Jung, Jin-Ho;Hong, Key-Jo;Min, Byung-Jun;Choe, Yearn-Seong;Lee, Kyung-Han;Kim, Byung-Tae
    • The Korean Journal of Nuclear Medicine
    • /
    • v.38 no.5
    • /
    • pp.338-343
    • /
    • 2004
  • Purpose: The purpose of this study was to develop a small animal PET using dual layer phoswich detector to minimize parallax error that degrades spatial resolution at the outer part of field-of-view (FOV). Materials and Methods: A simulation tool GATE (Geant4 Application for Tomographic Emission) was used to derive optimal parameters of small PET, and PET was developed employing the parameters. Lutetium Oxyorthosilicate (LSO) and Lutetium-Yttrium Aluminate-Perovskite(LuYAP) was used to construct dual layer phoswitch crystal. $8{\times}8$ arrays of LSO and LuYAP pixels, $2mm{\times}2mm{\times}8mm$ in size, were coupled to a 64-channel position sensitive photomultiplier tube. The system consisted of 16 detector modules arranged to one ring configuration (ring inner diameter 10 cm, FOV of 8 cm). The data from phoswich detector modules were fed into an ADC board in the data acquisition and preprocessing PC via sockets, decoder block, FPGA board, and bus board. These were linked to the master PC that stored the events data on hard disk. Results: In a preliminary test of the system, reconstructed images were obtained by using a pair of detectors and sensitivity and spatial resolution were measured. Spatial resolution was 2.3 mm FWHM and sensitivity was 10.9 $cps/{\mu}Ci$ at the center of FOV. Conclusion: The radioactivity distribution patterns were accurately represented in sinograms and images obtained by PET with a pair of detectors. These preliminary results indicate that it is promising to develop a high performance small animal PET.

Morphometric Study on the Arterial Palmar Arch of the Hand (손바닥 동맥활에 관한 형태계측 연구)

  • Park, Bong Kwon;Jang, Soo Won;Choi, Seung Suk;Ahn, Hee Chang
    • Archives of Plastic Surgery
    • /
    • v.36 no.6
    • /
    • pp.691-701
    • /
    • 2009
  • Purpose: Deviations of arterial palmar arches in the hand can be explained on the embryological basis. The purpose of this study was to provide new information about palmar arches through cadaver's dissection. The values of the location and diameter in these vessels were analyzed in order to support anatomical research and clinical correlation in the hand. Methods: The present report is based on an analysis of dissections of fifty - three hands carried out in the laboratory of gross anatomy. A reference line was established on the distal wrist crease to serve as the X coordinate and a perpendicular line drawn through the midpoint between middle and ring fingers, which served as the Y coordinate. The coordinates of the x and y values were measured by a digimatic caliper, and statistically analyzed with Student's t - test. Results: Complete superficial palmar archs were seen in 96.2 % of specimens. In the most common type of males, the superficial arch was formed only by the ulnar artery. In the most common type of females, the superficial arch was formed anastomosis between the radial artery and the ulnar artery. The average length of the superficial and deep palmar arch is $110.3{\pm}33.0mm$ and $67.9{\pm}14.0mm$ respectively. Regarding the superficial palmar arch, ulnar artery starts $-16.1{\pm}5.1mm$ on X - line, and $2.5{\pm}24.5mm$ on Y - line. Radial artery appears on palmar side $7.7{\pm}3.2mm$ on X - line, and $20.9{\pm}10.9mm$ on Y - line. But radial artery starts on $6.3{\pm}3.6mm$ on X - line, and $3.4{\pm}5.1mm$ on Y - line. Digital arteries of superficial palmar arch starts on $6.1{\pm}3.7mm$, $33.9{\pm}8.8mm$ on index finger, $1.8{\pm}3.4mm$, $40.1{\pm}7.3mm$ on middle finger, $-3.2{\pm}4.9mm$, $42.6{\pm}7.0mm$ on ring finger, and $-8.9{\pm}5.1mm$, $42.5{\pm}80mm$ on little finger in respective X and Y coordinates. Radial artery of deep palmar arches measured at the palmar side perforating from the dorsum of hand. It's coordinates were $9.7{\pm}4.8mm$ on X - line, $21.7{\pm}10.2mm$ on Y - line. Ulnar artery was measured at hypothenar area, and it's coordinates were $-20.4{\pm}6.3mm$ on X - line, and $30.6{\pm}7.4mm$ on Y - line. Conclusions: Anatomically superficial palmar arch can be divided into a complete and an incomplete type. Each of them can be subdivided into 4 types. The deep palmar arch is less variable than the superficial palmar arch. We believe these values of the study will be used for the vascular surgery of the hand using the endoscope and robot in the future.

Lane-wise Travel Speed Characteristics Analysis in Uninterrupted Flow Considering Lane-wise Speed Reversal (차로속도역전현상을 고려한 연속류 도로의 차로별 주행 속도 특성 분석)

  • Yang, Inchul;Jeon, Woo Hoon;Ki, Sung hwan;Yoon, Jungeun
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.15 no.6
    • /
    • pp.116-126
    • /
    • 2016
  • In this study, lane-wise traffic flow characteristics were analysed on uninterrupted flow using a new notion of "lane-wise travel speed reversal (LTSR)" which is defined as a phenomena that travel speed in the median lane is lower than other lanes. Mathematical formulation was also proposed to calculate the strength of LTSR. The experiment road site is Seoul Outer Ring Expressway (Jayuro-IC~Jangsoo-IC), and travel trajectories for each four lane were collected for weekdays (Mon. through Fri.) during morning peak. Comparing lane-wise travel speeds for entire test road section, no LTSR was observed, meaning that the travel speed in the median lane is the fastest, followed by 2nd, 3rd, and 4th lane as in order. Howerver, the result of microscopic analysis using 100-meter discrete road section based data shows that LTSR occurs many times. Especially the strength of LTSR is higher in congestion area and freeway merge and diverge segment. It is expected that these results could be used as a fundamental data when establishing lane-by-lane traffic operation strategy and developing lane-wise traffic information collection and dissemination technology.

Characteristics of Early-Age Restrained Shrinkage and Tensile Creep of Ultra-High Performance Cementitious Composites (UHPCC) (초고성능 시멘트 복합체의 초기 재령 구속 수축 및 인장 크리프 특성)

  • Yoo, Doo-Yeol;Park, Jung-Jun;Kim, Sung-Wook;Yoon, Young-Soo
    • Journal of the Korea Concrete Institute
    • /
    • v.23 no.5
    • /
    • pp.581-590
    • /
    • 2011
  • Since ultra-high performance cementitious composites (UHPCC) not only represents high early age shrinkage strain due to its low water-to-binder ratio (W/B) and high fineness admixture usage but also reduces the cross section of structure from the higher mechanical properties, it generally has more shrinkage cracks from the restraints of formwork and reinforcing bars. In this study, free and restrained shrinkage experiments were conducted to evaluate the suitability of incorporating both expansive admixture (EA) and shrinkage reducing agent (SRA). The test results indi-cated that approximately 40~44% of free shrinkage strain was decreased. Also, the results showed that 35% and 47% of residual tensile stresses were relieved by synergetic effect of SRA and EA, respectively. Residual tensile stresses from ringtest were relaxed by approximately 61% and 64% of elastic shrinkage stresses due to SRA and EA, respectively, because of the tensile creep effect. Therefore, the creep effect should be considered to precisely estimate the restrained shrinkage behavior of concrete structures. The degree of restraint of UHPCC was approximately in the range of 0.78~0.85. The addition of combined EA and SRA showed minute influence on the degree of restraint. However, the effect decreased when thicker concrete ring was used. Tensile creep strains were measured and compared to the predicted values from 4-parametric prediction model considering time dependent restrained forces.