• 제목/요약/키워드: Rigid fixation

검색결과 161건 처리시간 0.024초

Treatment of Nonsyndromic Craniosynostosis Using Multi-Split Osteotomy and Rigid Fixation with Absorbable Plates

  • Nam, Su Bong;Nam, Kyeong Wook;Lee, Jae Woo;Song, Kyeong Ho;Bae, Yong Chan
    • 대한두개안면성형외과학회지
    • /
    • 제17권4호
    • /
    • pp.211-217
    • /
    • 2016
  • Background: Nonsyndromic craniosynostosis is a relatively common craniofacial anomaly and various techniques were introduced to achieve its operative goals. Authors found that by using smaller bone fragments than that used in conventional cranioplasty, sufficiently rigid bone union and effective regeneration capacity could be achieved with better postoperative outcome, only if their stable fixation was ensured. Methods: Through bicoronal incisional approach, involved synostotic cranial bone together with its surrounding areas were removed. The resected bone flap was split into as many pieces as possible. The extent of this 'multi-split osteotomy' depends on the degree of dysmorphology, expectative volume increment after surgery and probable dead space caused by bony gap between bone segments. Rigid interosseous fixation was performed with variable types of absorbable plate and screw. In all cases, the pre-operational three-dimensional computed tomography (3D CT) was checked and brain CT was taken immediately after the surgery. Also about 12 months after the operation, 3D CT was checked again to see postoperative morphology improvement, bone union, regeneration and intracranial volume change. Results: The bony gaps seen in the immediate postoperative brain CT were all improved as seen in the 3D CT after 12 months from the surgery. No small bone fragment resorption was observed. Brain volume increase was found to be made gradually, leaving no case of remaining epidural dead space. Conclusion: We conclude that it is meaningful in presenting a new possibility to be applied to not only nonsyndromic craniosynostosis but also other reconstructive cranial vault surgeries.

생체 흡수성 고정판을 이용한 하악골 골절치료의 예후 (THE PROGNOSIS OF FIXATION OF MANDIBULAR FRACTURES WITH BIODEGRADABLE PLATES AND SCREWS)

  • 최진호;김주록;하태진;유장배;김일규
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제27권1호
    • /
    • pp.32-38
    • /
    • 2005
  • The efficacy of bioresorbable fixation has recently been described in the osseosynthesis of the oral & maxillofacial region. However, a liitle data exist regarding the use of biodegradable plates and screws for the internal fixation of human mandible fractures. The purpose of this study is to analyze and compare the treatment of mandibular fractures by using a bioresorbable fixation system with conventional titanium system in human mandible fractures. eighteen patients constituted the bioresorbable fixation group and twenty-five patients constituted the titanium fixation group. Both groups underwent open reduction and internal fixation by use of a bioresorbable system or a titanium fixation system. Panoramic radiograph were obtained preoperatively, immediately postoperatively after reduction, at 6 months and at 12 months postoperatively. In the bioresorbable fixation group, complication(infection) occurred in 1 patient(5.6%) and was resolved by incision & drainage, plate removal and antibiotics without untoward sequelae. 2 patients(8.0%) experienced complications in the titanium fixation group and were treated using conservative treatment. There was no statistical difference in complication rates between two groups. Our data supported the use of bioresorbale plate fixation in mandibular fractures as a means of avoiding the potential and well documented problems with rigid titanium fixation systems. In conclusion, the bioresorbable fixation system provide a reliable and sufficient alternative to conventional titanium plate system.

Compression Osteosynthesis로 하악골골절을 치료한 경우 골절선상의 치아가 감염에 미치는 영향

  • 최병호;유재하;윤중호
    • 대한치과의사협회지
    • /
    • 제32권1호통권296호
    • /
    • pp.69-74
    • /
    • 1994
  • Fifty-one patients with fracture of mandible were treated by rigid internal fixation using AO Eccentric Dynamic Compression Plate. All teeth in the fracture line were left in all patients. None of patients were placed into maxillomancibular fixation. Two patients postoperatively developed infection (3.9%). The use of the AO EDCP for the fracture of mandible was found to be useful to prevent the infection, even permitting maintenance of the teeth in the line of fracture.

  • PDF

하악골 골절환자에서 술후 자가통증조절장치와 근주용 진통제의 효과에 관한 비교 (A COMPARATIVE STUDY ON POST-OPERATIVE ANALGESIC EFFECT FOR PATIENT-CONTROLLED AND INTRAMUSCULAR ANALGESIA IN MANDIBULAR FRACTURE PATIENTS)

  • 이석재;김경욱;김철환
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제28권1호
    • /
    • pp.42-48
    • /
    • 2006
  • Open reduction and rigid internal fixation is the most popular treatment method for maxillofacial fracture patients, and it is unevitable that postoperative pain can be developed. Many surgeons including oral & maxillofacial surgeons have made constant efforts to decrease postoperative pain. This study is a comparison of postoperative analgesia and intramuscular analgesia in patients with mandibular fractures. In this study, twenty-one patients (Experimental group) were randomly selected and they were injected with IV patient-controlled analgesia (PCA; Walkmed$^{(R)}$, USA). For control group another twenty-one patients were injected with intramusclar non-steroid anti-inflammatory drugs (Rheoma$^{(R)}$, Samsung Pharm. Co.). And then, we measured visual analogue scale (VAS) scores from first postoperative day to second day at regular time interval. The following results were uptained; 1. In patient group who with open reduction and rigid internal fixation, there was significant difference of postoperative analgesic effect during the first postoperative day(p<0.05). 2. In patient group with over 90 minutes surgery time, there was significant difference of postoperative analgesic effect during the first and second postoperative day when compared between experimental group and control group(p<0.05). 3. In patient group with less than 90 minutes surgery time, there was no significant difference of postoperative analgesic effect during the first and second postoperative day when compared between experimental group and control group(p>0.05). 4. In patient group with surgery of open reduction using rigid internal fixation at single fractured site, there was no significant difference of postoperative analgesic effect during the first and second postoperative day when compared between experimental group and control group(p>0.05). 5. In patient group with surgery at two fractured sites, there was significant difference of postoperative analgesic effect during the first postoperative day when compared between experimental group and control group(p<0.05). As mentioned above, it suggest that patient-controlled analgesia is more effective for postoperative pain relief than intramuscular injection in patients with rigid internal fixation by open reduction after mandibular fracture occurred. Especially, it is considered that in patient with more than 90 minutes surgery time or in cases with multiple fractured sites had more effective results with PCA therapy than conventional intramuscular analgesics.

환축추체 후방 나사고정술 후 생긴 동정맥루 (Arteriovenous Fistula after C1-2 Posterior Transarticular Screw Fixation - Case Report -)

  • 이혁기;조재훈;이성락;강동기;김상철;김용선
    • Journal of Korean Neurosurgical Society
    • /
    • 제29권2호
    • /
    • pp.280-285
    • /
    • 2000
  • Posterior transarticular screw fixation for atlantoaxial instability due to trauma or rheumatoid arthritis provides immediate rigid fixation of the C1-2 vertebral segment while preserving motion between the occiput and C1. This technique provides more resistance to translational and rotational forces than wiring technique. However, the technique of transarticular screw fixation is inherently demanding because of the complex anatomy of the occipitocervical region and vertebral artery(VA) at risk for arterial damage. VA injury may lead to serious subsequent neurological deficits and possibly death from bilateral VA injury. We report a case of a vertebral artery-to-epidural venous plexus fistula after posterior transarticular screw fixation which was treated with balloon occlusion.

  • PDF

Delayed degradation according to the location of fixation with using an absorbable plate

  • Kim, Tae Ho;Kang, Seok Joo;Sun, Hook
    • 대한두개안면성형외과학회지
    • /
    • 제19권2호
    • /
    • pp.114-119
    • /
    • 2018
  • Background: The ideal absorbable plating system should provide sufficient rigidity and then be absorbed within a timely manner. The Resorb-X has been recently developed as a plating system with a mixture ratio of 50:50 poly(D, L-lactide). Methods: We present seven of 121 patients who experienced delayed degradation with this absorbable plate. One hundred twenty-one patients with facial bone fracture underwent surgical treatment from March 2011 to March 2015, and rigid fixation was achieved with the Resorb-X. Results: Of 121 patients, seven (5.8%) developed complications at the surgical sites. Six of 102 cases underwent fixation of the infraorbital rim and one of 73 underwent fixation of the frontozygomatic buttress; the other sites of fixation did not develop delayed degradation. Foreign body granuloma developed at the earliest by postoperative 20 months and at the latest by postoperative 28 months (average, 23.5 months). Conclusion: We observed that the use of absorbable plates in incision sites or areas with thin skin can increase the possibility of delayed degradation. When performing surgery in these areas, the normal skin above the fixed location should be covered sufficiently.

뚜껑문 안와저 골절에 있어서 망상 흡수성 판을 이용한 관혈적 정복술 및 내고정술 (Open Reduction and Internal Fixation (ORIF) of Trapdoor Orbital Floor Blowout Fracture with Absorbable Mesh Plate)

  • 권유진;김지훈;황재하;김광석;이삼용
    • Archives of Plastic Surgery
    • /
    • 제37권5호
    • /
    • pp.619-625
    • /
    • 2010
  • Purpose: Trapdoor orbital blowout fracture is most common in orbital blowout fracture. Various materials have been used to reconstruct orbital floor blowout fracture. Absorbable alloplastic implants are needed because of disadvantages of nonabsorbable alloplastic materials and donor morbidity of autogenous tissue. The aim of the study is to evaluate usefulness of absorbable mesh plate as a reconstructive material for orbital blowout fractures. Methods: From December 2008 to October 2009, 18 trapdoor orbital floor blowout fracture patients were treated using elevator fixation, depressor fixation, or elevatordepressor fixation techniques with absorbable mesh plates and screw, depending on degree of orbital floor reduction, because absorbable mesh plates are less rigid than titanium plates and other artificial substitutes. Results: Among 18 patients, 5 elevator fixation, 4 depressor fixation, and 9 elevator and depressor fixation technique were performed. In all patients, postoperative computed tomographic (CT) scan showed complete reduction of orbital contents and orbital floor, and no displacement of bony fragment and mesh plate. Mean follow-up was 10 months. There were no significant intraoperative or postoperative complications. Conclusion: Three different techniques depending on the degree of orbital floor reduction are useful for open reduction and internal fixation of trapdoor orbital floor blowout fracture with absorbable mesh plates.

A Mid-Term Follow-Up Result of Spinopelvic Fixation Using Iliac Screws for Lumbosacral Fusion

  • Hyun, Seung-Jae;Rhim, Seung-Chul;Kim, Yong-Jung J.;Kim, Young-Bae
    • Journal of Korean Neurosurgical Society
    • /
    • 제48권4호
    • /
    • pp.347-353
    • /
    • 2010
  • Objective : Iliac screw fixation has been used to prevent premature loosening of sacral fixation and to provide more rigid fixation of the sacropelvic unit. We describe our technique for iliac screw placement and review our experience with this technique. Methods : Thirteen consecutive patients who underwent spinopelvic fixation using iliac screws were enrolled. The indications for spinopelvic fixation included long segment fusions for spinal deformity and post-operative flat-back syndrome, symptomatic pseudoarthrosis of previous lumbosacral fusions, high-grade lumbosacral spondylolisthesis, lumbosacral tumors, and sacral fractures. Radiographic outcomes were assessed using plain radiographs, and computed tomographic scans. Clinical outcomes were assessed using the Oswestry Disability Index (ODI) and questionnaire about buttock pain. Results : The median follow-up period was 33 months (range, 13-54 months). Radiographic fusion across the lumbosacral junction was obtained in all 13 patients. The average pre- and post-operative ODI scores were 40.0 and 17.5, respectively. The questionnaire for buttock pain revealed the following : 9 patients (69%) perceived improvement; 3 patients (23%) reported no change; and 1 patient (7.6%) had aggravation of pain. Two patients complained of prominence of the iliac hardware. The complications included one violation of the greater sciatic notch and one deep wound infection. Conclusion : Iliac screw fixation is a safe and valuable technique that provides added structural support to S1 screws in long-segment spinal fusions. Iliac screw fixation is an extensive surgical procedure with potential complications, but high success rates can be achieved when it is performed systematically and in appropriately selected patients.

Lumbo-iliac Fixation Using Modified Galveston Technique in a Patient with Metastatic Sacral Tumor

  • Shin, Dong-Ah;Kim, Hyo-Jun;Shin, Dong-Gyu;Kim, Hyoung-Ihl
    • Journal of Korean Neurosurgical Society
    • /
    • 제41권1호
    • /
    • pp.61-64
    • /
    • 2007
  • Lumbo-sacral junction is a transition lone between the mobile lumbar spine and immobile pelvis. Lumbosacral junction has been considered to be the most troublesome portion of the spine to be fused because of the difference in anatomical and biomechanical factors between spine and pelvis. A metastatic sacral tumor in a 57-year-old man was resected, followed by unilateral lumbo-iliac fixation across lumbosacral junction using modified Galveston technique. Rigid fixation was successfully achieved. Detailed anatomy and surgical techniques are presented.

A Review of Subbrow Approach in the Management of Non-Complicated Anterior Table Frontal Sinus Fracture

  • Kim, Jeenam;Choi, Hyungon
    • 대한두개안면성형외과학회지
    • /
    • 제17권4호
    • /
    • pp.186-189
    • /
    • 2016
  • Frontal sinus fractures, particularly anterior sinus fractures, are relatively common facial fractures. Many agree on the general principles of frontal fracture management; however, the optimal methods of reduction are controversial. The subbrow approach enables accurate reduction and internal fixation of the fractures in the anterior table of the frontal sinus by allowing direct visualization of the fracture. Given the surgical success in reduction and rigid fixation, patient satisfaction, and aesthetic benefits, the transcutaneous approach through a subbrow incision is superior to other reduction techniques used in the management of an anterior table frontal sinus fracture.