• Title/Summary/Keyword: Right-handed

Search Result 339, Processing Time 0.025 seconds

The Effect of Performance of a Stop Signal Task on the Execution and Stop Function of Movement (정지신호과제의 수행이 동작의 실행과 정지기능에 미치는 영향)

  • Kwon, Jung-Won;Nam, Seok-Hyun;Kim, Chung-Sun
    • The Journal of Korean Physical Therapy
    • /
    • v.23 no.1
    • /
    • pp.37-43
    • /
    • 2011
  • Purpose: We studied the changes in motor response time and stop signal response time following visuomotor skill learning of a stop signal task in young healthy subjects. This study also was designed to determine what an effective practice is for different stop signals in the stop signal task (SST). Methods: Forty-five right-handed normal volunteers without a history of neurological dysfunction were recruited. They all gave written informed consent. In all subjects, motor reaction time (RT) and stop signal reaction time (SSRT) were measured for the stop signal task. Tasks were classified into three categories: predictable-stop signal task (P-SST) practice group random-stop signal task (R-SST) practice group control group. Results: Motor reaction time in the P-SST was significantly reduced when comparing pre- and post-tests (p<0.05). Stop signal reaction times in the P-SST and the R-SST were significantly reduced following motor skill learning (p<0.05). Also, the reaction time of the R-SST was shorter than that of the P-SST. Conclusion: These findings indicate that practice of an SST improves motor performance and stop function for some stop signals in the SST. P-SST practice was effective in the stop function of regular movement because of faster of the motor prediction and preparation but the R-SST was effective in the stop function of movements because of faster motor selection.

Backpack Palsy (배낭으로 인한 상완 신경총 마비)

  • Yoon, Oong-Yong;Lee, Kyu-Yong;Lee, Young Ju;Kim, Hee-Tae;Kim, Juhan;Kim, Myung-Ho
    • Annals of Clinical Neurophysiology
    • /
    • v.3 no.2
    • /
    • pp.143-146
    • /
    • 2001
  • Background : Backpack palsy was described in military personnel with shoulder girdle and proximal upper extremity symptoms, predominantly motor in nature related to the use of heavy backpack. Currently, backpack were used for sports, transporting school books and child carriers. We evaluated clinical and electrophysiological feature of backpack palsy. Methods : We included 11 patients with brachial plexopathy as a result of wearing a heavy backpack on long distance marches. All patients were done routine blood sampling, chest X-ray, C-spine X-ray and electrophysiological studies. Results : All patients were right handed person and were not as having a thoracic outlet syndrome. Sensory changes were main initial symptoms and major persistent symptoms were motor weakness. 9 patients(81.8%) were damaged the brachial plexus on non-dominant side, 1 patient was dominant and 1 patient was bilateral involvement. 10 patients(90.9%) were damaged to upper trunk of the brachial plexus by EMG findings. The prognosis was good, 10 patients(90.9%) were complete recovery during 8 weeks, 1 patient was developed reflex sympathetic dystrophy confirmed by 3-phase bone scan. Conclusions : Depression of the clavicle and costoclavicular space probably plays a certain role in pathogenic mechanism. The non-dominant side is more frequently affected, probably due to underdevelopment of the musculature in that side.

  • PDF

A Dual-Band Asymmetrical Metamaterial Antenna for Orthogonal Radiation Patterns (수직한 방사패턴을 형성하는 이중대역 비대칭 배열 메타물질 안테나)

  • Pyo, Seong-Min;Han, Sang-Min;Lee, Dong-Hyo;Kim, Young-Sik
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.9
    • /
    • pp.2246-2252
    • /
    • 2009
  • A new metamaterial antenna with dual resonant modes is presented using an asymmetrical periodic arrangement for orthogonal radiation patterns. The proposed antenna produces two orthogonal modes by the asymmetrical periodic unit-cell arrangement. The orthogonal resonant mode provides perpendicular radiation patterns without changing the antenna polarization at each resonant mode. The fabricated antenna shows good agreements with the theoretical analysis of the electric-field. The experimental results shows the orthogonal radiation patterns along x- and y-axises, and gains are 3.34 and 3.86 dBi at each radiating resonant mode, respectively. Additionally, slotted ground structures are embedded on the back side of the antenna in order to reduce the size and enhance the radiation efficiency of 12 % and 27 %, respectively.

Dual-Band Unequal Power Divider based on CRLH Transmission Line (CRLH 전송선로를 기반으로 한 이중대역 비대칭 전력 분배기)

  • Yoo, Jae-Hyun;Kim, Young;Yoon, Young-Chul
    • Journal of Advanced Navigation Technology
    • /
    • v.14 no.6
    • /
    • pp.909-915
    • /
    • 2010
  • In this paper, the unequal power divider based on CRLH (Composite Right/Left-Handed) transmission line with dual-band characteristic is proposed. They consist of dual-band branch line hybrid coupler, the connection between input and isolation port of hybrid coupler and ${\lambda}/4$ impedance transformer. When the transmission line between input and isolation port of hybrid coupler is asymmetrical connected, the divider is obtained the output results of the equal phase and unequal power dividing ratio. The simulation results of the divider represent the power ratio of 0 dB ~ 20 dB. To validate a function of divider, the hybrid coupler and transformer with 880 MHz and 1850 MHz is implemented. As a result, the proposed unequal divider obtains the power ratio of 3.2 dB ~ 8.8 dB at 880 MHz and 2.5 dB ~ 14.0 dB at 1850 MHz.

An Electrode Configuration for Recording Muscle Motor Evoked Potentials in the Upper Extremities during Intraoperative Neurophysiological Monitoring

  • Choi, Young-Doo;Jin, Seung-Hyun;Kim, Chi-Heon;Kwak, Gil Ho;Kim, Bo Eun;Chung, Chun Kee
    • Journal of Korean Neurosurgical Society
    • /
    • v.60 no.4
    • /
    • pp.475-480
    • /
    • 2017
  • Objective : The main aim of the present study is to examine the electrode configurations used to record the muscle motor evoked potential (mMEP) in the upper extremities during surgery with the goal of producing a high and stable mMEP signal, in particular among the abductor pollicis brevis (APB), abductor digiti minimi (ADM), and across the APB-ADM muscles, which have been widely used for the mMEP in the upper extremities. Methods : Thirty right-handed patients were recruited in this prospective study. No patients showed any adverse events in their mMEP signals of the upper extremities during surgery. The mMEPs were recorded independently from the signals for the APB and ADM and for those across the APB-ADM. Results : The mMEP amplitude from across the APB-ADM was statistically higher than those recorded from the APB and ADM muscles. Moreover, the coefficient of variation of the mMEP amplitude from across the APB-ADM was smaller than those of mMEP amplitude recorded from the APB and ADM muscles. Conclusion : The mMEP from across the APB-ADM muscles showed a high yield with high stability compared to those in each case from the APB and ADM muscles. The configuration across the APB-ADM muscles would be best for mMEP recordings from the upper extremities for intraoperative neurophysiological monitoring purposes.

Deep Learning Model for Mental Fatigue Discrimination System based on EEG (뇌파기반 정신적 피로 판별을 위한 딥러닝 모델)

  • Seo, Ssang-Hee
    • Journal of Digital Convergence
    • /
    • v.19 no.10
    • /
    • pp.295-301
    • /
    • 2021
  • Individual mental fatigue not only reduces cognitive ability and work performance, but also becomes a major factor in large and small accidents occurring in daily life. In this paper, a CNN model for EEG-based mental fatigue discrimination was proposed. To this end, EEG in the resting state and task state were collected and applied to the proposed CNN model, and then the model performance was analyzed. All subjects who participated in the experiment were right-handed male students attending university, with and average age of 25.5 years. Spectral analysis was performed on the measured EEG in each state, and the performance of the CNN model was compared and analyzed using the raw EEG, absolute power, and relative power as input data of the CNN model. As a result, the relative power of the occipital lobe position in the alpha band showed the best performance. The model accuracy is 85.6% for training data, 78.5% for validation, and 95.7% for test data. The proposed model can be applied to the development of an automated system for mental fatigue detection.

Derivation of EEG Spectrum-based Feature Parameters for Mental Fatigue Determination (정신적 피로 판별을 위한 뇌파 스펙트럼 기반 특징 파라미터 도출)

  • Seo, Ssang-Hee
    • Journal of Convergence for Information Technology
    • /
    • v.11 no.10
    • /
    • pp.10-19
    • /
    • 2021
  • In this paper, we tried to derive characteristic parameters that reflect mental fatigue through EEG measurement and analysis. For this purpose, mental fatigue was induced through a resting state with eyes closed and performing subtraction operations in mental arithmetic for 30 minutes. Five subjects participated in the experiment, and all subjects were right-handed male students in university, with an average age of 25.5 years. Spectral analysis was performed on the EEG collected at the beginning and the end of the experiment to derive feature parameters reflecting mental fatigue. As a result of the analysis, the absolute power of the alpha band in the occipital lobe and the temporal lobe increased as the mental fatigue increased, while the relative power decreased. Also, the difference in power between resting state and task state showed that the relative power was larger than the absolute power. These results indicate that alpha relative power in the occipital lobe and temporal lobe is a feature parameter reflecting mental fatigue. The results of this study can be utilized as feature parameters for the development of an automated system for mental fatigue determination such as fatigue and drowsiness while driving.

Feasibility of a New Desktop Motion Analysis System with a Video Game Console for Assessing Various Three-Dimensional Wrist Motions

  • Kim, Kwang Gi;Park, Chan Soo;Jeon, Suk Ha;Jung, Eui Yub;Ha, Jiyun;Lee, Sanglim
    • Clinics in Orthopedic Surgery
    • /
    • v.10 no.4
    • /
    • pp.468-478
    • /
    • 2018
  • Background: The restriction of wrist motion results in limited hand function, and the evaluation of the range of wrist motion is related to the evaluation of wrist function. To analyze and compare the wrist motion during four selected tasks, we developed a new desktop motion analysis system using the motion controller for a home video game console. Methods: Eighteen healthy, right-handed subjects performed 15 trials of selective tasks (dart throwing, hammering, circumduction, and winding thread on a reel) with both wrists. The signals of light-emitting diode markers attached to the hand and forearm were detected by the optic receptor in the motion controller. We compared the results between both wrists and between motions with similar motion paths. Results: The parameters (range of motion, offset, coupling, and orientations of the oblique plane) for wrist motion were not significantly different between both wrists, except for radioulnar deviation for hammering and the orientation for thread winding. In each wrist, the ranges for hammering were larger than those for dart throwing. The offsets and the orientations of the oblique plane were not significantly different between circumduction and thread winding. Conclusions: The results for the parameters of dart throwing, hammering, and circumduction of our motion analysis system using the motion controller were considerably similar to those of the previous studies with three-dimensional reconstruction with computed tomography, electrogoniometer, and motion capture system. Therefore, our system may be a cost-effective and simple method for wrist motion analysis.

Work-Related Upper Extremity Musculoskeletal Pain Korean Baristas (한국의 바리스타들의 업무 관련 상지 근골격계 통증)

  • Kim, Ha-Eun;Kwon, Ye-Lim;Park, Hyun-Ju;Kang, Jul-Gi;Lee, Ji-In;Kim, Eun-Joo
    • Journal of the Korea Convergence Society
    • /
    • v.10 no.7
    • /
    • pp.335-342
    • /
    • 2019
  • The purpose of this study was to investigate the current status of work-related upper extremity musculoskeletal pain in baristas and to identify the elements that are related to pain. The questionnaires were distributed to 100 workers in 63 cafes on Jeonju city in Korea. As a result of investigating work related pain, 65.3% (n=64) answered "yes" to the question that had pain at least once a week, month, or year, or 34.7% (n=34) answered "no". Most of the workers were right-handed, and when they felt pain, they felt 25 to 50% of time per day. Especially, baristas reported that the use of porter filters during work and the tamping operation were the most painful. In conclusion, our study indicated that necessary to introduce and develop a program to prevent cafe worker disease, as well as need to future research to improve work environment and posture according to the characteristics of the cafe works.

Immediate Effect on Mu-rhythm of Somatosensory Cortex using Visual Feedback Training in Healthy Adults (건강한 성인에서 시각적 되먹임 훈련이 감각운동겉질의 뮤-리듬에 미치는 즉각적인 효과 )

  • Su-Bok Kim;On-Seok Lee
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.18 no.3
    • /
    • pp.47-53
    • /
    • 2023
  • PURPOSE: A visual feedback method was proposed to induce brain stimulation in a stroke patient, and among them, there was a treatment using a mirror. On the other hand, mirror therapy focuses only on the functional changes in body movements, and analysis of neurophysiological mechanisms of brain activity is lacking. In addition, studies on evaluating the activity and response generated in specific brain regions during visual feedback training using mirrors are insufficient. METHODS: Fifteen healthy adults (male: 10, female: 5, Years: 23.33 ± 1.23), who were right-handed were recruited. By attaching the C3, Cz, and C4 channels in the sensorimotor cortex using an electroencephalogram, training was performed under the conditions without mirror-based visual feedback (No-condition) and with visual feedback (Tasks-condition). At this time, the immediate activity of the mu-rhythm in response to training was separated and evaluated. RESULTS: The tasks-condition of C3, Cz, and C4 channels activated the relative mu-rhythm rather than the no-condition, and all showed significant differences (p < .05). In addition, in all channels at the start time, the tasks-condition was more active than the no-condition (p < .05). The activity of the cortical response was higher in the tasks-condition than in the no-condition (p < .05). CONCLUSION: The mu-rhythm activity can be evaluated objectively when visual feedback using a mirror is applied to healthy subjects, and a basic analysis protocol is proposed.