• Title/Summary/Keyword: Right/left-handed

Search Result 230, Processing Time 0.024 seconds

Development of Impedance Plethysmograph and Measurement of Digital Blood Flow (임피던스 혈류량측정기의 개발 및 손가락 혈류량의 측정)

  • 김덕원;송철규
    • Journal of Biomedical Engineering Research
    • /
    • v.12 no.1
    • /
    • pp.23-28
    • /
    • 1991
  • In this study electrical impedance plethysmograph was developed and each ten digital blood flow was measured for eight nomal males and a patient tvith digital arterial reconstruction surgery. Blood flow of the digit with surgery was approximately fourty percent compared to that of the other normal digit. For the normal subjects, right - handed subjects generally have larger blood flow in right fingers than that in left fingers while it was reverse for the left - handed subjects. The relative average magnitude of the digltal blood flow Is the third, first, second, fourth, and fifth digit in descending order for the left and rich hand, respectively. Blood flow of the fifth digit for all subjec!s except one was the smallest among the five digits.

  • PDF

A Survey of Inconveniences and Injuries Experienced by the Left-handed People from Using Right-handed Products (오른손잡이 전용제품 사용에 있어서 왼손잡이의 불편도와 상해경험에 관한 연구)

  • Jung, Hwa-Shik
    • Journal of the Korea Safety Management & Science
    • /
    • v.11 no.1
    • /
    • pp.35-41
    • /
    • 2009
  • 대부분의 사람들은 의식하지 못하지만 세상은 오른손잡이 중심으로 이뤄져 있기 때문에 왼손잡이가 일상적으로 겪는 불편은 상상외로 많다. 우리가 일상에서 많이 사용하는 연장, 주방기구, 사무용품, 가전제품, 가구, 의류, 악기, 의료기기, 스포츠용품, 공공시설 등 이들 대부분이 오른손잡이에게 맞춰져 있어 왼손잡이들은 자신들의 왼팔을 비틀어서 사용하거나 주손이 아닌 오른손으로 부자연스런 자세로 사용할 수밖에 없다. 이에 따라 왼손잡이는 일상생활에 있어서의 상당한 불편을 느낄 뿐만 아니라 작업 능률의 저하, 재해나 상해를 입을 가능성이 높아질 수 있다. 본 연구는 무작위로 선정된 피설문자에 대한 설문 조사를 통하여 손잡이(handedness)와 관련된 통계수치를 제공하고 왼손잡이인 경우 왼손잡이로서 일상생활에서의 불편함, 작업능률의 저하여부, 오른손잡이 전용제품을 사용하여 상해를 입은 경험 등에 대해 조사하였다. 또한 왼손잡이도 편리하게 사용할 수 있으면 하는 제품이나 공공시설 등에 대한 이들의 주관적인 견해에 대해서도 조사하였다. 이를 토대로 왼손잡이를 위한 공구, 주방용품, 문구용품, 스포츠용품, 사무용품 등에 대하여 현재 적용되어 있는 상품에 대한 고찰과 향후 적용 가능 상품 및 공공시설에 대해 제안하였다.

The Study of Muscle Activity for the Upper Extremity over Morto-Seoinage(Two-handed shoulder throw) in Judo (유도 양손 업어치기 시 상지근의 근 활성도에 관한 연구)

  • Kim, Ji-Tae;Cho, Young-Je;Lee, Deck-Young
    • Korean Journal of Applied Biomechanics
    • /
    • v.17 no.3
    • /
    • pp.95-103
    • /
    • 2007
  • The purpose of this study is Muscle Activity for the Upper Extremity and Morto-Seoinage(Two-handed shoulder throw) according to performance levels and elite judo players (G1) and non-elite judo players, namely university players (G2). To achieve this purpose, three players in G1 whose main special skill was Morote-Seoinage and three university judo players(G2) were selected as comparative group. After analysing this study, conclusions were derived as follows. 1. Muscle activity of musculi membri superious to group of Kuzushi to Tsukuri was the highest in left biceps brachii and right biceps brachii in order. On the other hand, G2 was the highest in left biceps brachii and left flexer carpi randialis in order. 2. Intergral electromyogram of according to the phase showed right triceps 1P of left flexer carpi radialis. G1 and G2 of showed left biceps brachii was the highest in 1P and 2P. As a result, extra training of left flexer carpi radialis and left biceps brachii is needed.

Studies on Motor Activity Log-28 and Actual Amount of Use Test, Actual Amount of Use Test Inter-rater Reliability in Healthy Individuals: Age Dependence and Handedness (연령과 손잡이에 따른 정상인들의 Motor Activity Log-28과 Actual Amount of Use Test 연구 및 Actual Amount of Use Test의 평가자간 신뢰도연구)

  • Kim, Kyeong-hyeon;Shin, Yu-mi;Lim, Mi-yu;Jung, Yu-chang;Oh, Ji-eun;Kim, Su-jin
    • Physical Therapy Korea
    • /
    • v.26 no.2
    • /
    • pp.24-33
    • /
    • 2019
  • Background: Spontaneous use of the upper extremities on the affected side of patients with stroke is a meaningful indicator of recovery and may vary by the age or dominant hand of patients. No prior study has reported changes in actual amount of use test (AAUT) and motor activity log (MAL)-28 according to age and handedness in healthy adults, and AAUT inter-rater reliability for assessment of healthy adults. Objects: This study aimed to (1) research the differences in AAUT and MAL-28 according to age and handedness in healthy adults, and (2) determine the inter-rater reliability of the AAUT. Methods: Seventy healthy adults participated in this study. The MAL-28 was assessed by dividing 61 subjects into young right-handed ($n_1=20$), young left-handed ($n_2=21$), and older right-handed ($n_3=20$) groups. The AAUT was assessed by dividing 63 subjects into young right-handed ($n_1=25$), young left-handed ($n_2=18$), and older right-handed ($n_3=20$) groups. Student's t-test and the Wilcoxon signedrank test were used for statistical analysis. Results: The Amount of Use (AOU) scale values for each group showed no significant differences between age groups and handedness groups in the MAL-28 (p>.05). The AAUT AOU scale value showed significant differences regarding dominant handedness in the AAUT (p<.05), but no significant differences according to age (p>.05). (2) Inter-rater reliability of the AAUT was excellent, except few items (item 9, 11, and 12). Conclusion: Although both the MAL-28 and the AAUT measured how much participants used their dominant arms in healthy subjects, the AAUT only showed significantly higher dominant arm use in left hander than the right hander. In addition, the inter-rater reliability of the AAUT was excellent. Current results can be utilized as a basic information when clinicians develop rehabilitation strategies, and AAUT was shown to be a reliable evaluation tool for measurement of upper extremity use in Korean adults, based on the reliability demonstrated by this study.

Can Right-Handed Surgeons Insert Upper Thoracic Pedicle Screws in much Comfortable Position? Right-Handedness Problem on the Left Side

  • Akyoldas, Goktug;Senturk, Salim;Yaman, Onur;Ozdemir, Nail;Acaroglu, Emre
    • Journal of Korean Neurosurgical Society
    • /
    • v.61 no.5
    • /
    • pp.568-573
    • /
    • 2018
  • Objective : Thoracic pedicles have special and specific properties. In particular, upper thoracic pedicles are positioned in craniocaudal plane. Therefore, manipulation of thoracic pedicle screws on the left side is difficult for right-handed surgeons. We recommend a new position to insert thoracic pedicle screw that will be much comfortable for spine surgeons. Methods : We retrospectively reviewed 33 patients who underwent upper thoracic pedicle screw instrumentation. In 15 patients, a total of 110 thoracic pedicle screws were inserted to the upper thoracic spine (T1-6) with classical position (anesthesiologist and monitor were placed near to patient's head. Surgeons were standing classically near to patient's body while patients were lying in prone position). In 18 patients, a total of 88 thoracic pedicle screws were inserted to the upper thoracic spine with the new standing position-surgeons stand by the head of the patient and the anesthesia monitor laterally and under patient's belt level. All the operations performed by the same senior spine surgeons with the help of C-arm. Postoperative computed tomography scans were obtained to assess the screw placement. The screw malposition and pedicle wall violations were divided and evaluated separately. Cortical penetration were measured and graded at either : 1-2 mm penetration, 2-4 mm penetration and >4 mm penetration. Results : Total 198 screws were inserted with two different standing positions. Of 198 screws 110 were in the classical positioning group and 88 were in the new positioning group. Incorrect screw placement was found in 33 screws (16.6%). The difference between total screw malposition by both standing positions were found to be statistically significant (p=0.011). The difference between total pedicle wall violations by both standing positions were found to be statistically significant (p=0.003). Conclusion : Right-handedness is a problem during the upper thoracic pedicle screw placement on the left side. Changing the surgeon's position standing near to patient's head could provide a much comfortable position to orient the craniocaudal plane of the thoracic pedicles.

A New CPW Dual Band Wilkinson Power Divider Using Composite Right/Left-Handed Transmission Line (Composite Righg/Left-Hand 전송선로를 이용한 새로운 이중대역의 CPW 윌킨슨 전력 분배기)

  • Zhang, Zufu;Wang, Yang;Yoon, Ki-Cheol;Lee, Jong-Chul
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.14 no.6
    • /
    • pp.117-124
    • /
    • 2015
  • In this paper, a new kind of wideband, low-loss composite right/left-handed (CRLH) transmission line (TL) and a Wilkinson power divider are presented. The TL is composed of a parallel meander inductor and a series cutting capacitor based on coplanar waveguide (CPW) structure. The power divider is designed by substituting the CRLH-TL into the conventional transmission line. The experiment results show that the TL has a good agreement with the desired results, exhibiting the return losses under 12 dB from 8.4 GHz to 34.4 GHz. The operating frequencies of the power divider are 12.05 GHz to 13.15 GHz and 16.50 GHz to 19.30 GHz, respectively. The 20 dB bandwidths are 8.9 % and 17.9 %, respectively. Typical experimental measurements are conducted and compared with the simulated results.

-1 Mode Circular Polarization Antenna Design by Using Cross Aperture-Coupled Feed (십자 개구 결합 급전을 이용한 -1 모드 원형 편파 안테나)

  • Kim, Jun-Sik;Lee, Jeong-Hae
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.25 no.2
    • /
    • pp.156-163
    • /
    • 2014
  • In this paper, a compact circularly polarized metamaterial patch antenna using cross aperture-coupled feed is proposed. The CP antenna utilizes the -1 mode that is induced by the composit right-left handed(CRLH) transmission line. Since the -1 mode has the same properties with the $TM_{010}$ mode of the conventional patch antenna, the circular polarization(CP) can be realized. If two orthogonal modes are excited with $90^{\circ}$ phase difference, the CP property can be obtained. In order to obtain two orthogonal modes and $90^{\circ}$ phase difference, 4 mushroom structures having the shape of square are employed. The width and length of the cross aperture are optimized through the design algorithm. The fabricated antenna is based on RT/duroid5880 substrate and the total area of the 4 mushroom is $0.25{\lambda}_0{\times}0.25{\lambda}_0$. The center frequency of the LHCP(Left-Handed Circular Polarization) antenna is measured as 1.622 GHz and circular polarization bandwidth(3 dB) is measured as 3 MHz. The center frequency of the RHCP(Right-Handed Circular Polarization) antenna is measured as 1.609 GHz and circular polarization bandwidth (3 dB) is measured as 3 MHz, respectively. The measured radiation efficiency of LHCP antenna is 61.1 % and the measured radiation efficiency of RHCP antenna is 54.5 %.

The Effects of a Mental Image Drawing on Left Neglect: a Case Study (심상그리기가 좌편 무시현상에 미치는 영향: 사례연구)

  • Kim, Ha-Kyung;Hwang, Young-Jin;Jeong, Ok-Ran
    • Speech Sciences
    • /
    • v.12 no.3
    • /
    • pp.91-102
    • /
    • 2005
  • This study investigated to the effects of a mental image drawing in RHD patients with left neglect. Three subjects participated in this study. All subjects were right handed and native speaker of korean. In task 1, the patients were presented with visual stimulus card directly above the response sheet and were asked to draw the picture. In task 2, they were presented with items auditorily and asked to draw the picture(mental image drawing). In all experimental conditions, there was no response time limit. The results showed that the subjects showed left neglect leaving some space on the left side in task 1. And the picture was drawn the left side from the right in direction. However, the neglect disappeared in task 2. And the picture was drawn the right side from the left in direction. The results of the present study suggested that a mental image drawing technique can be effective in treating individuals who exhibit left neglect. Also, the picture direction showed that the korean normality was same.

  • PDF

Dual CRLH Based Band Stop Filter Using Conductor-Backed Defected Coplanar Waveguide

  • Yang, Doo-Yeong;Yang, Lei
    • International Journal of Contents
    • /
    • v.11 no.3
    • /
    • pp.34-38
    • /
    • 2015
  • A band stop filter is proposed with cascading unit cells that are based on a dual composite right/left-handed (D-CRLH) conductorbacked coplanar waveguide. The parameters of the unit cell have been analyzed to confirm the behavior of each component for the equivalent circuit of the cell. We simulated the dispersion characteristics and energy distribution and have determined that the unit cell has a D-CRLH property. The band stop filter was implemented by symmetrically cascading two of the proposed unit cells. The experimental results for the band stop filter revealed a band rejection performance of 32 dB and a return loss of 0.35 dB in the stopband frequency range from 869MHz to 954MHz. Finally, we show that there is a good agreement in the experimental results and those obtained through the simulations.

A Compact Zeroth-Order Resonant Antenna on Vialess CPW Single Layer

  • Jang, Tae-Hee;Lim, Sung-Joon
    • ETRI Journal
    • /
    • v.32 no.3
    • /
    • pp.472-474
    • /
    • 2010
  • In this letter, a novel zeroth-order resonant (ZOR) antenna on vialess co-planar waveguide (CPW) is proposed. It is based on a composite right/left-handed CPW transmission line. To achieve a compact size, this antenna utilizes the ZOR condition, and its reactive parameters determine the resonant frequency. Each unit cell is composed of a metallic top patch and meander lines. Since it is realized on the CPW single layer, the proposed antenna has the benefits of being a compact size and easy to fabricate. The bandwidth of 6.8% and efficiency of 62% are experimentally achieved. Its bandwidth is enhanced compared with other ZOR antennas.