• Title/Summary/Keyword: Rib effect

Search Result 294, Processing Time 0.02 seconds

Effects of Melengesterol Acetate, Selenium and Vitamin E Supplemental Feeding on Growth, Carcass and Longissimus Dorsi Muscle Traits in Hanwoo Cull Cows (한우 노산암소에 대한 발정억제제 및 항산화제의 급여가 증체와 도체성적에 미치는 영향)

  • 정준;이성수;박노형;성낙일;장윤호;최성호;송만강;서형기;이명일
    • Journal of Animal Science and Technology
    • /
    • v.48 no.2
    • /
    • pp.255-268
    • /
    • 2006
  • Twenty four Hanwoo cull cows were assigned to 2 groups, control and melengerol acetate(MGA)+selenium supplement containing vitamin E(SeE), based on the parity(6.5±1.7 birth) and body weight (493.17±55.61kg), and the experiment was conducted to establish the reasonable fattening method of cull cows for 240 days. Average daily body gains during 240 days were 0.51kg and 0.63kg in control and MGA+SeE, respectively(P<0.10). DDMI/ADG of MGA+SeE group improved compared to control group(P<0.05). Therefore, supplementation of MGA+SeE in concentrates may accelerate both of the growth rate and feed efficiency in Hanwoo cull cows. MQI from MGA+SeE was more developed based on the larger rib-eye area and thinner backfat thickness in carcass than that from control. Marbling score for MGA+SeE tended to increase compared to control. Dietary Se supplementation significantly affected muscle Se concentration in longissimus dorsi meat of MGA+SeE group(P<0.05). Similar results to Se were obtained from α-Tocoperol concentration. During 7 days of simulated retail display, accumulations of thiobarbituric acid reactive substances(TBARS) concentration in beef was greater(P<0.05) in control than in supplemented cows. These results supported the hypothesis that supplementation of MGA+SeE improve the growth performance and carcass grade both by the growth stimulating effect of MGA+SeE and by preventing the oxidation of the longissimus dorsi muscle in Hanwoo cull cows.

Recent Progress in Air-Conditioning and Refrigeration Research: A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2014 (설비공학 분야의 최근 연구 동향: 2014년 학회지 논문에 대한 종합적 고찰)

  • Lee, Dae-Young;Kim, Sa Ryang;Kim, Hyun-Jung;Kim, Dong-Seon;Park, Jun-Seok;Ihm, Pyeong Chan
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.27 no.7
    • /
    • pp.380-394
    • /
    • 2015
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2014. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. Conclusions are as follows. (1) The research works on the thermal and fluid engineering have been reviewed as groups of heat and mass transfer, cooling and heating, and air-conditioning, the flow inside building rooms, and smoke control on fire. Research issues dealing with duct and pipe were reduced, but flows inside building rooms, and smoke controls were newly added in thermal and fluid engineering research area. (2) Research works on heat transfer area have been reviewed in the categories of heat transfer characteristics, pool boiling and condensing heat transfer and industrial heat exchangers. Researches on heat transfer characteristics included the results for thermal contact resistance measurement of metal interface, a fan coil with an oval-type heat exchanger, fouling characteristics of plate heat exchangers, effect of rib pitch in a two wall divergent channel, semi-empirical analysis in vertical mesoscale tubes, an integrated drying machine, microscale surface wrinkles, brazed plate heat exchangers, numerical analysis in printed circuit heat exchanger. In the area of pool boiling and condensing, non-uniform air flow, PCM applied thermal storage wall system, a new wavy cylindrical shape capsule, and HFC32/HFC152a mixtures on enhanced tubes, were actively studied. In the area of industrial heat exchangers, researches on solar water storage tank, effective design on the inserting part of refrigerator door gasket, impact of different boundary conditions in generating g-function, various construction of SCW type ground heat exchanger and a heat pump for closed cooling water heat recovery were performed. (3) In the field of refrigeration, various studies were carried out in the categories of refrigeration cycle, alternative refrigeration and modelling and controls including energy recoveries from industrial boilers and vehicles, improvement of dehumidification systems, novel defrost systems, fault diagnosis and optimum controls for heat pump systems. It is particularly notable that a substantial number of studies were dedicated for the development of air-conditioning and power recovery systems for electric vehicles in this year. (4) In building mechanical system research fields, seventeen studies were reported for achieving effective design of the mechanical systems, and also for maximizing the energy efficiency of buildings. The topics of the studies included energy performance, HVAC system, ventilation, and renewable energies, piping in the buildings. Proposed designs, performance performance tests using numerical methods and experiments provide useful information and key data which can improve the energy efficiency of the buildings. (5) The field of architectural environment was mostly focused on indoor environment and building energy. The main researches of indoor environment were related to the evaluation of work noise in tunnel construction and the simulation and development of a light-shelf system. The subjects of building energy were worked on the energy saving of office building applied with window blind and phase change material(PCM), a method of existing building energy simulation using energy audit data, the estimation of thermal consumption unit of apartment building and its case studies, dynamic window performance, a writing method of energy consumption report and energy estimation of apartment building using district heating system. The remained studies were related to the improvement of architectural engineering education system for plant engineering industry, estimating cooling and heating degree days for variable base temperature, a prediction method of underground temperature, the comfort control algorithm of car air conditioner, the smoke control performance evaluation of high-rise building, evaluation of thermal energy systems of bio safety laboratory and a development of measuring device of solar heat gain coefficient of fenestration system.

Effect of Cooking methods with Various Heating Apparatus on the Quality Characteristics of Beef (가열기구에 따른 조리방법이 소고기의 품질특성에 미치는 영향)

  • Jeon, Ki-Hong;Kwon, Ki-Hyun;Kim, Eun-Mi;Kim, Young-Boong;Sohn, Dong-In;Choi, Jin-Young
    • Culinary science and hospitality research
    • /
    • v.19 no.5
    • /
    • pp.196-205
    • /
    • 2013
  • This study showed the chemico-physical characteristics and sensory evaluation of beef loin and ribs with various kinds of cooking apparatus and methods like pan heating, boiling, grilling, steaming, cooking heating, charcoal heating and double layer pan heating. Double layer pan filled with Phase Change Materials(PCM) heating was also tested. Heating time of beef loin and ribs by oven heating was the longest as 55.5 and 25.7 min. Cooking loss of beef loin and ribs were 40.49%, 27.98% each and showed biggest in charcoal heating(p<0.05). In the chemical analysis, grilling resulted in the highest protein contents of 29.3% in the loin and double layer pan heating had 28.6% in the ribs. In the loin, 20.3% of crude fat was the highest in the double layer pan heating, and 21.9% of crude fat of ribs in the PCM heating(p<0.05). In the test of shearing forces, double layer pan heating had the lowest result of $9.14kg/cm^2$ in the loin and $7.03kg/cm^2$ in the ribs. In the 9 point-scale sensory evaluation, PCM treatment showed the best result of 7.67 in the juiciness of loin and single layer pan heating and grilling treatment had the highest score of 7.00 in the ribs. Loin in the PCM heating had 7.11 and ribs in the grilling had 7.13, showing the best in overall acceptability. With this experiments, we could find the chemico-physical and sensory characteristics of beef loin and ribs were affected by various cooking methods.

  • PDF

A re-appraisal of scoring items in state assessment of NATM tunnel considering influencing factors causing longitudinal cracks (종방향균열 영향인자 분석을 통한 NATM터널 정밀안전진단 상태평가 항목의 재검토)

  • Choo, Jin-Ho;Yoo, Chang-Kyoon;Oh, Young-Chul;Lee, In-Mo
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.21 no.4
    • /
    • pp.479-499
    • /
    • 2019
  • State assessment of an operational tunnel is usually done by performing visual inspection and durability tests by following the detailed guideline for safety inspection (SI) and/ or precision inspection for safety and diagnosis (PISD). In this study, 12 NATM tunnels, which have been operational for more than 10 years, were inspected to figure out the cause of longitudinal cracks for the purpose of modifying the scoring items in the state assessment NATM tunnel related to the longitudinal crack and the thickness of concrete lining. All investigated tunnels were classified into four groups depending on the shape and usage of each tunnel. The causes of longitudinal crack occurrence were analyzed by investigating the correlations between the longitudinal crack and the following four factors: the patterns of ground excavation; construction state of primary support system; characteristics of material properties of the concrete lining; and thickness of lining which was obtained by Ground Penetration Radar (GPR) tests. It was found that influencing factors causing longitudinal cracks in the lining were closely related with the construction condition of the primary support system, i.e. shotcrete, rockbolt, and steel-rib; crack occurrences were not much affected by the excavation patterns. As for the properties of concrete lining materials, occurrence of the longitudinal crack was mostly affected by the following three items: w/c ratio; contents of cement; and strength of lining. When estimating the lining thickness of the concrete lining by GPR tests and taking thickness effect into account in the statement assessment, it was concluded that increase of the index score by an average of 0.03 (ranging from 0.01 up to 0.071) is needed; a more realistic way of state assessment should be proposed in which the increased index score caused by lack of lining thickness should be taken into account.