• Title/Summary/Keyword: Rib effect

Search Result 294, Processing Time 0.024 seconds

Effect of Punch Design and Flow Stress on Frictional Calibration Curve in Boss and Rib Test (보스-리브 시험 시 마찰보정선도에 대한 펀치형상 및 유동응력의 영향)

  • Yun, Y.W.;Kang, S.H.;Lee, Y.S.;Kim, B.M.
    • Transactions of Materials Processing
    • /
    • v.18 no.8
    • /
    • pp.640-645
    • /
    • 2009
  • Recently, boss and rib test based on backward extrusion process was proposed to quantitatively evaluate the interfacial friction condition in bulk forming process. In this test, the tube-shaped punch with hole pressurizes the workpiece so that the boss and rib are formed along the hole and outer surface of the punch. It was experimentally and numerically revealed that the height of boss is higher than that of the rib under the severe friction condition. This work is focused on the effect of the punch design and flow stress on deformation pattern in boss and rib test. From the boss and rib test simulations, it was found that there is slight variation in both the heights of boss and rib according to the length of punch land, nose radius, and face angle. However the hole diameter of the punch and the clearance between the punch and die have a significant influence on the calibration curves showing the heights of the boss and rib. In addition, the effect of flow stress on the calibration curves was investigated through FE simulations. It was found that there is no effect of strength coefficient of the workpiece on the calibration curves for estimation of friction condition. On the other hand, the strain-hardening exponent of the workpiece has a significant influence on the calibration curve.

Effect of Punch Design and Friction Condition on Deformation Pattern in Boss and Rib Test (보스-리브 시험 시 펀치 형상 및 마찰 조건에 따른 변형 양상에 대한 연구)

  • Yun, Y.W.;Kang, S.H.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2009.10a
    • /
    • pp.332-337
    • /
    • 2009
  • Recently, boss and rib test based on backward extrusion process was proposed to quantitative evaluate the interfacial friction condition in bulk forming process. In this test, the tube-shaped punch with hole pressurizes the workpiece so that the boss and rib are formed along the hole and outer surface of the punch. It was experimentally and numerically revealed that the height of boss is higher than that of the rib under the severe friction condition. This work is focused on the effect of the punch design and friction condition on deformation pattern in boss and rib test. From the boss and rib test simulations, it was found that there is slight variation in both the heights of boss and rib according to the length of punch land, nose radius, and face angle. However the hole diameter of the punch and the clearance between the punch and die have a significant influence on the heights of the boss and rib. In addition, the effect of flow stress was also investigated on the deformation patterns through FE simulations.

  • PDF

Lap Splice Strength of Reinforcing Bars on the Relitive Rib Area (상대마디면적에 따른 이형철근의 겹침이음 강도)

  • Park, Sung-Gyu;Hong, Geon-Ho;Choi, Dong-Uk
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2005.05a
    • /
    • pp.307-310
    • /
    • 2005
  • The effects of deformation properties on the bond of steel reinforcing bars to concrete are experimentally studies to expect the lap splice strength. Based on the previous research about relative rib area, lap splice strength between reinforcing bars and concrete can be improved by the control of rib height and spacing. This paper describes the testing and analysis of 15 beam-spliced specimens containing D25, D22, D19 with relative rib areas ranging from 0.066 to 0.162. The tests are analyzed to determine the effect of relative rib area(Rr) on the increase in bond strength. The tests also provide a preliminary indication of the effect of high relative rib area on the splice strength of uncoated bars.

  • PDF

Effect of Heat/Mass Transfer in the turbine blade internal passage with various rib arrangement (회전하는 터빈 블레이드 이차유로내 요철 배열이 열/물질전달에 미치는 영향)

  • Lee, Sei-Young;Cho, Hyung-Hee
    • Proceedings of the KSME Conference
    • /
    • 2001.11b
    • /
    • pp.22-29
    • /
    • 2001
  • The present study investigates the effects of various rib arrangements and rotating on heat/mass transfer in the cooling passage of gas turbine blades. The cooling passage has very complex flow structure, because of the rib turbulator and rotating effect. Experiments and numerical calculation are conducted to investigate the complex flow structures and heat transfer characteristics; the numerical computation is performed using a commercial code, FLUENT ver.5, to calculate the flow structures and the experiments are conducted to measure heat/mass transfer coefficients using a naphthalene sublimation technique. For the rotating duct tests, the test duct, which is the cross section of is $20mm\times40mm$ (the hydraulic diameter, $D_h$, of 26.7 mm, has two-pass with $180^{\circ}$ turning and the rectangular ribs on the wall. The rib angle of attack is $70^{\circ}$ and the maximum radius of rotation is $21.63D_h$. The partition wall has 10 mm thickness, which is 0.5 times to the channel width, and the distance between the tip of the partition wall and the outer wall of the turning region is 26.7 mm $(1D_h)$. The turning effect of duct flow makes the very complex flow structure including Dean type vortex and high turbulence, so that the heat/mass transfer increases in the turning region and at the entrance of the second pass. The Coriolis effect deflects the flow to the trailing surface, resulting in enhancement of the heat/mass transfer on the trailing surface and reduction on the leading surface in the first pass. However, the opposite phenomena are observed in the second pass. The each rib arrangement makes different secondary flow patterns. The complex heat/mass transfer characteristics are observed by the combined effects of the rib arrangements, duct rotation and flow turning.

  • PDF

Effect of Rib Height on Turbulence and Convective Heat Transfer (리브의 높이가 난류 및 열전달특성에 미치는 영향)

  • Nine, Md.J.;Kim, S.J.;Jeong, H.M.;Chung, H.S.;Rahman, M.Sq.
    • Journal of Power System Engineering
    • /
    • v.16 no.6
    • /
    • pp.30-37
    • /
    • 2012
  • Effect of rib heights is found as significant parameter to enhance convective heat transfer performance under laminar and low turbulent regime. Circular ribs with different ribheight to channel height ratios, e/H = 0.05, 0.1, 0.15, are fabricated over the copper substrate respectively in a rectangular duct having 7.5 cross sectional aspect ratio. Only one rib pitch to rib height ratio (P/e = 10) has been chosen for all different height ribs. The result shows that the arithmetic average of turbulence intensity decreases with decreasing roughness height calculated between two ribs under laminar and low turbulent region. It occurs because the area of recirculation and reattachment zone also decreases with decreasing rib height. Optimum thermal enhancement factor is derived by 0.1 rib height to channel height ratio under low turbulent region but 0.15 rib height to channel height ratio gives maximum subjected to laminar flow.

Prognosis of Pulmonary Function in Patients with Multiple Rib Fractures

  • Park, Hee Beom;Hyun, Sung Youl;Kim, Jin Joo;Jang, Yeon Sik
    • Journal of Trauma and Injury
    • /
    • v.30 no.4
    • /
    • pp.179-185
    • /
    • 2017
  • Purpose: Rib fracture is the most common complication of blunt thoracic trauma. We investigated the effect of rib fracture on pulmonary function in the conservatively treated patients. Methods: From January 2000 to February 2017, we reviewed the records of 72 patients with rib fracture and pulmonary function tests were performed. According to the number of rib fractures, patients were classified into two groups: less than six fractured ribs (group A) and more than six fractured ribs (group B). The groups were compared concerning demographics, underlying diseases, associated thoracic injuries, surgery, mechanical ventilator times, days spent in the intensive care unit and pulmonary function test. Results: There were no statistically significant differences in the demographic data between the two groups. Mean hospitalization was 13.5 days in group A and 27.0 days in group B (p<0.001). There was no statistically significant difference between the two groups in the pulmonary function test. Conclusions: We conclude that pulmonary function is restored by conservative treatment in patients with rib fractures even if the number of rib fractures increases. In patients with multiple rib fractures, studies comparing open rib fixation and conservative treatment of long term pulmonary function are required.

Analysis of Energy Flow and Barrier Rib Height Effect using Ray-Optics Incorporated Three-dimensional PDP Cell Simulation

  • Chung, Woo-Joon;Jeong, Dong-Cheol;Whang, Ki-Woon;Park, Jae-Hyeung;Lee, Byoung-Ho
    • Journal of Information Display
    • /
    • v.2 no.4
    • /
    • pp.46-51
    • /
    • 2001
  • Using ray-optics code incorporated with three-dimensional PDP cell simulation, we have analysed the energy flow in the PDP cell from the electric power input to the visible light output. Also, the visible light output profile and viewing angle distribution were obtained. We applied our code to the analysis of the barrier rib height effect on the visible light luminance and efficiency of the sustaining discharge. Although cells with higher barrier rib generate more VUV photons, less ratio of visible photons are emitted toward front panel due to the shadow effect. Thus, there exists optimal barrier rib height giving the highest visible luminance and efficiency. This kind of code can be a powerful tool in designing cell geometry.

  • PDF

Aqueous alkali-developable Photosensitive Barrier Rib Paste for PDP and Photolithographic Process

  • Park, Lee-Soon;Jeong, Seung-Won;Kim, Soon-Hak;Tae, Heung-Sik
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2000.01a
    • /
    • pp.177-179
    • /
    • 2000
  • Barrier rib for the plasma display panel (PDP) was made by photolithographic process utilizing photosensitive barrier rib paste. The barrier rib paste was prepared by first dissolving poly(MMA-co-MAA) binder polymer in butyl carbitol(BC) solvent at 15 wt% concentration. To this solution were added a mixture of functional monomers , Irgacure 651 photoinitiator, and barrier rib power and then the whole mixture was dispersed in the three roll mill for 2 hour. The effect of component and concentration of photosensitive barrier rib paste was studied. After optimization of the paste formulation and photolithographic process, barrier rib could be obtained with good resolution up to 110-120 ${\mu}m$ height and 80-90 ${\mu}m$ width.

  • PDF

Effect of Barrier Rib Height Variation on the Luminous Characteristics of AC PDP

  • Bae, Hyun-Sook;Whang, Ki-Woong
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2003.07a
    • /
    • pp.91-94
    • /
    • 2003
  • We studied the effect of barrier rib height variation using ray-optics code incorporated with three-dimensional plasma simulation to analyze the effects of cell geometry for varying pressure conditions. The optimal barrier rib height decreased as the Xe partial pressure increased which resulted in due to the formation of local, strong sheath under high Xe partial pressure condition.

  • PDF

Detailed Measurement of Heat/Mass Transfer in a Rotating Two-Pass Duct (II) - Effects of Duct Aspect Ratio - (이차 냉각 유로를 가진 회전덕트에서 열/물질전달 특성 (II) - 덕트 종횡비에 따른 영향 -)

  • Kim Kyung Min;Kim Yun Young;Rhee Dong Ho;Cho Hyung Hee
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.28 no.8 s.227
    • /
    • pp.921-928
    • /
    • 2004
  • Measurements of local heat/mass transfer coefficients in rotating two-pass ducts are presented. Ducts of three different aspect ratios (W/H), 0.5, 1.0 and 2.0, are employed with a fixed hydraulic diameter ($D_h$) of 26.7 nm. $90^{\circ}$-rib turbulators are attached on the leading and trailing walls symmetrically. The rib height-to-hydraulic diameter ratio ($e/D_h$) is 0.056, and the rib pitch-to-rib height ratio (p/e) is 10. The experimental conditions are the same as those of the previous part of the study. As the rib height-to-duct height ratio (e/H) increases, the core flow is more disturbed and accelerated in the midsections of ribs. Therefore, the obtained data show higher heat/mass transfer in the higher aspect ratio duct. Dean vortices also augment heat/mass transfer in the turn and in the upstream region of the second pass. However, the effect becomes less significant for the higher aspect ratio because the surface area increases in the present geometric condition. The effect of rotation produces heat/mass transfer discrepancy.