Separation of Functionalized Heterocyclic Compounds by High Performance Liquid Chromatography (II) (고성능 액체 크로마토그래피에 의한 기능성 헤테로 고리 화합물의 분리(II))

  • Cho, Yun Jin;Lee, Young Cheol;Lee, Kwang-PiII;Park, Keung-Shik
    • Analytical Science and Technology
    • /
    • v.11 no.4
    • /
    • pp.292-296
    • /
    • 1998
  • Normal phase or reversed phase liquid chromatographic separation of isoquinoline of heterocyclic compounds and structural isomers of external substituents, $COOCH_3$, CN and $CH_3$ has been carried out by using several different columns and various mobile phases. From this results, the order of elution of heterocyclic compounds appears to depend on the solvent effect with kinds of mobile phases. Retention mechanism of normal phase system for 2-methylindoline, 2-methylindole, benzoxazole and benzothiazole was also studied depending on adsorption strength between solute and stationary phase of column. However, retention factors of reversed phase system were found on hydrophobic interaction with solvophobic effect.

  • PDF

Determination of Ginseng Saponins by Reversed-Phase High Performance Liquid Chromatography (역상 고속 액체크로마토그래피를 이용한 인삼 사포닌의 분석)

  • Jeong, Seung-Il;Kim, Choen-Suk;Lee, No-Woon;Choi, Kang-Ju;Lee, Yong-Gu;Kim, Il-Kwang
    • Analytical Science and Technology
    • /
    • v.11 no.6
    • /
    • pp.436-439
    • /
    • 1998
  • Ginseng saponins were analysed using reversed-phase high performance liquid chromatography with several columns. The optimum conditions were as following : reverse phase column; Novapak $C_{18}$ ODS column ($3.9mm{\times}150mm$, $5{\mu}m$), acetonitrile/water binary mobile phase gradient controller system, solvent flow rate; 1.5 mL/min, and UV (203 nm) detector. The complete separation of ginsenoside $Rb_1$, $Rb_2$, Rc, Rd, Re, Rf and $Rg_1$ was achieved within 50 min. The regression coefficients of the calibration curves for seven ginsenosides were 0.98~0.99.

  • PDF

Determination Method of Puerarin and Daidzin from Puerariae Radix by Reversed-Phase HPLC with Pulsed Amperometric Detection (RP-HPLC-PAD를 이용한 갈근(葛根)과 갈근(葛根) 함유 처방의 Puerarin과 Daidzin 분석)

  • Chiao, Chen-Ying;Kwon, Ha-Jeong;Jeong, Ji-Seon;Lee, Je-Hyun;Hong, Seon-Pyo
    • The Korea Journal of Herbology
    • /
    • v.23 no.4
    • /
    • pp.171-177
    • /
    • 2008
  • Objectives: This study presents a reversed-phase high-performance liquid chromatography- pulsed amperometric detection(RP-HPLC-PAD) method for the determination of puerarin and daidzin in Puerariae Radix extract and Chinese medicinal preparations. Methods: Chromatographic separation was performed using a 10% acetonitrile with a reversed-phase column(Unison UK-C18, $100mm{\times}2.0mm$ I.D.; $3{\mu}m$). The analyses were detected by pulsed amperometric detector(PAD) in alkaline conditions by combining with post-column NaOH solution. Geniposide was used as an internal standard. Results: The limit of detection(S/N=3) and the limit of quantification(S/N=10) were 0.025 ng, 0.075 ng for puerarin, and 0.05 ng, 0.15 ng for daidzin, respectively. The intra- and inter-day precisions(RSDs) were less than 6.5% and average recoveries of puerarin were 99.7-101.3% and those of daidzin were 101.0-102.8%. Conclusions: According to above results, we developed a determination method for puerarin and daidzin in Puerariae Radix with high sensitivity and selectivitely.

  • PDF

Determination of Uranium and Thorium in Natural Ground Water by Reversed Phase Liquid Chromatography (역상액체크로마토그래피에 의한 지하수 중 U 및 Th의 분리정량)

  • Lee, Chang Heon;Jo, Gi Su;Seo, Mu Yeol;Lee, Won
    • Journal of the Korean Chemical Society
    • /
    • v.38 no.7
    • /
    • pp.502-508
    • /
    • 1994
  • The measurement of trace amounts of uranium(VI) and thorium(VI) in the solutions containing high concentration of dissolved salts was carried out. The procedure using reversed phase liquid chromatography with trace enrichment techniques has been developed to cope with the high salt content of the samples. 2 ml of sample were passed through a small C_{18}$ reversed phase enrichment column with ${\alpha}$-HIBA eluent (0.11 M, pH 5.5) where the uranium and thorium were separated from other constituents and concentrated. The uranium and thorium were then backflushed from the column onto a deactivated C_{18}$ reversed phase analytical column where furthe separation was achieved with a mixed eluent (pH3.0, 0.17M ${\alpha}$-HIBA/0.0038 M 1-pentanesulfonate). The separated species were determined spectrophotometrically by postcolumn reaction with Arsenazo III, the chromogenic reagent. Detection limits were found within 1 ppb range for both species.

  • PDF

Avantor® ACE® Wide Pore HPLC Columns for the Separation and Purification of Proteins in Biopharmaceuticals (바이오의약품의 단백질 분리 및 정제를 위한 Avantor® ACE® 와이드 포어 HPLC 컬럼 가이드)

  • Matt James;Mark Fever;Tony Edge
    • FOCUS: LIFE SCIENCE
    • /
    • no.1
    • /
    • pp.3.1-3.7
    • /
    • 2024
  • The article discusses the critical role of chromatography in the analysis and purification of proteins in biopharmaceuticals, emphasizing the importance of comprehensive characterization for ensuring their safety and efficacy. It highlights the use of Avantor® ACE® HPLC columns for the separation and purification of proteins, focusing on the analysis of intact proteins using reversed-phase liquid chromatography (RPLC) with fully porous particles. This article also details the application of different mobile phase additives, such as TFA and formic acid, and emphasizes the advantages of using type B ultra-pure silica-based columns for efficiency and peak shape in biomolecule analysis. Additionally, it addresses the challenges of analyzing intact proteins due to slow molecular diffusion and introduces the concept of solid-core (or superficially porous) particles, emphasizing their benefits over traditional porous particles for the analysis of therapeutic proteins. Furthermore, it discusses the development of Avantor® ACE® UltraCore BIO columns, specifically designed for the high-efficiency separation of large biomolecules, such as proteins, and demonstrates their effectiveness in achieving high-resolution separations, even for higher molecular weight proteins like monoclonal antibodies (mAbs). In addition, it underscores the complexity of analyzing and characterizing intact protein biopharmaceuticals, requiring a range of analytical techniques and the use of wide-pore stationary phases, operated at elevated temperatures and with relatively shallow gradients. It highlights the comprehensive range of options offered by Avantor® ACE® wide pore columns, including both fully porous and solid-core particles, bonded with a variety of complementary stationary phase chemistries to optimize selectivity during method development. The use of ultrapure and highly inert base silica is emphasized for enabling the use of lower concentrations of mobile phase modifiers without compromising analyte peak shape, particularly beneficial for LC-MS applications. Then the article concludes by emphasizing the significance of reversed-phase liquid chromatography and its compatibility with mass spectrometry as a valuable tool for the separation and analysis of intact proteins and their closely related variants in biopharmaceuticals.

  • PDF

On-line Trace Enrichment for the Determination of Insulin in Biological Samples Using Reversed-Phase High Performance Liquid Chromatography with Column Switching

  • Lee, Jung-Sook;Lee, Heeyong;Lee, Hye-Suk;Lee, Kang-Choon
    • Archives of Pharmacal Research
    • /
    • v.17 no.5
    • /
    • pp.360-363
    • /
    • 1994
  • Column--swtiching technique with a reversed-phase high performance liquid chromatographic method has been developed for the routine analysis of radioiodinated insulin and its degadation products in biological fluids. The diluted biological samples were loaded onto a precolumn packed with LiChrosorb RP-8 $(25-40{\;}{\mu}m)$ using 0.1% trifuoroacetic acid (TFA) in water as a washing solvent. After valve switching, the concentrated insulins were eluted in the back-flush mode and separated by a W-Porex $C_{18}$ column with a gradient of 0.1% TFA in water and 0.1% TFA in acetonitrile as the mobile phase. The method showed good precision, accuracy and speed with the detection limit of 20 pg/ml. Total analysis time per sample was about 40 min and the coefficients of variation were less than 8, 2%.

  • PDF

Optical Resolution of Dansyl Amino Acids with Addition of Benzyl-L-Hydroxyproline Copper(II) Chelate by High Performance Liquid Chromatography

  • Sun Haing Lee;Tae Sub Oh;Sang Hyun Bak
    • Bulletin of the Korean Chemical Society
    • /
    • v.10 no.6
    • /
    • pp.491-495
    • /
    • 1989
  • Resolution of enantiomers of DNS-amino acids has been achieved by a reversed phase liquid chromatography with an addition of a copper(Ⅱ) complex of N-benzyl-L-hydroxyproline to the mobile phase. N-Benzyl-L-hydroxyproline was prepared and used as a chiral ligand of copper(Ⅱ) chelate for the optical resolution. The pH and the concentration of copper(Ⅱ) chelate, organic solvent, and buffer agent in the mobile phase all affect the optical resolutions of dansyl amino acids. The elution orders between D and L-DNS-amino acids were different depending on the structure of the side chain of the amino acids. The retention mechanism for the chiral separation of the dansyl amino acids can be illustrated by the equilibrium of ligand exchange and by hydrophobic interaction with $C_{18}$ stationary phase. The chiral separation can be illustrated with cis and trans effect of the ligand exchange reaction.

Linear Solvation Energy Comparison Study in Normal Phase Liquid Chromatography Ⅰ (정상 액체크로마토그래피에서의 선형 용매화에너지 비교법 연구 Ⅰ)

  • Choe, Jang Deok;Jeong, Won Jo
    • Journal of the Korean Chemical Society
    • /
    • v.38 no.3
    • /
    • pp.221-223
    • /
    • 1994
  • We tried to apply the linear solvation energy comparison method to solute retention in normal phase liquid chromatography. Correlation coefficients of regression of lnk' collected in a fixed eluent against solute polarity indices have proven to be lower than those obtained from reversed phase liquid chromatography data. This event can be attributed to complexity of solute retention process in normal phase liquid chromatography. We concluded from the regression results that each specific polarity of the stationary phase is greater than that of the mobile phase and that the difference in each polarity between the stationary phase and the mobile phase decreases as the volume fraction(${\phi}$) of the more polar solvent in the mobile phase increases. Correlations of lnk' of a single solute against solvent polarity indices have proven to be meaningless owing to covariance among the solvent polarity indices. Instead, a good linear relationship between lnk' and solvent ${\pi}^*$ was observed, and its linearity is better than that between lnk' and ${\phi}$.

  • PDF

Mutation Analysis in β2-Adrenergic Receptor Gene by Single Strand Conformation Polymorphism (SSCP) and Denaturing High Performance Liquid Chromatography (DHPLC) (SSCP와 DHPLC에 의한 β2-교감신경수용체 유전자의 돌연변이 분석)

  • Park, Sang-Bum;Han, Sang-Man;Nam, Youn-Hyoung;Jang, Won-Cheoul
    • Analytical Science and Technology
    • /
    • v.17 no.1
    • /
    • pp.53-59
    • /
    • 2004
  • Up to now, methods for the detection of genetic alterations as single strand conformation polymorphism (SSCP) or denaturing gradient gel electrophoresis (DGGE) have been used. It is too labor-intensive and expensive to serve for routine analysis. Moreover, lower in its sensitivity and specificity being also strongly dependent on the experience of the investigater. To improve these problems, we analysed mutation of ${\beta}_2$-adrenergic receptor gene that controls bronchial asthma by denaturing high performance liquid chromatography (DHPLC) according to ion-pair reversed phase chromatography (IP-RPC). We extracted genomic DNA from 80 asthma patients and then amplified DNA using PCR and analysed PCR product by SSCP and DHPLC. As a result, we analysed mutation frequency is 19 (23.75%) on SSCP and 25 (31.25%) on DHPLC in ${\beta}_2$-adrenergic receptor gene. We conclude that DHPLC is a fast and simple screening method rather than SSCP analysis.

Liquid Chromatography of Aromatic Sulfonic Acids by Tetramethylammonium Bromide (Tetramethylammonium Bromide를 이용한 방향족 술폰산들의 액체크로마토그래피)

  • Oh, Hae-Beom
    • Journal of the Korean Chemical Society
    • /
    • v.37 no.9
    • /
    • pp.793-799
    • /
    • 1993
  • Ion-pair model was predominated over ion-interaction model in the retention mechanism of analytes when tetramethylammonium bromide (TMAB) was used as a counter-ion in the investigation of aromatic sulfonic acids on the reversed-phase liquid chromatography by $C_{18}$ column as a stationary phase. The capacity factors of analytes were influenced by the type and concentration of counter-ions, concentrations of methanol and co-anion, types and position of functional group, and the pH mobile phase. Components of analyte mixture could be separated under the optimum conditions by this method.

  • PDF