• 제목/요약/키워드: Reverse Control

검색결과 1,137건 처리시간 0.033초

전기처리에 의한 주목의 삽목발근에 관한 연구 (Studies on Rooting of Taxus cuspidata Cuttings by Electric Treatment)

  • 정진철;최정호;장규관
    • 한국조경학회지
    • /
    • 제22권2호
    • /
    • pp.123-132
    • /
    • 1994
  • Tow-year-old Taxus cuspidata shoot cuttings were treated with various electrical impacts of cathode on their base and anode on their apex by normal and reverse source. The cuttings were previously treated with 200ppm IBA for 12 hours and the rooting percentage, the length, and the weight of roots were checked. The auxin contents of cuttings were also examined by high-performance liquid chromatography. The results obtained on this study are as follows; 1. Normal treatment, cathode into the base and anode into apex, seemed to accelerate rooting while reverse treatment showed less effective than normal treatment on rooting, but both treatments were more effective than control. 2. The impact of electrical treatment at 30mV for 30min has a remarkable effect on the percentage rooting, the length, and the weight of roots. 3. Root primordia were formed at the basipetal end of cuttings where the end of primary pith ray meets the cambium in control treatment and formed at the basal part of cuttings irregularly in electrical treatment. 4. High-performance liquid chromatography showed electrical treatment was more effective on auxin accumulation than control, and 30mV-30min was the most effective on auxin accumulation.

  • PDF

천연형 인 적혈구 조혈인자의 변이원성시험 (Mutagenicity Study of Recombinant Human Erythropoietin(rhEPO))

  • 강경구;조현;김동환;백남기;김원배
    • Biomolecules & Therapeutics
    • /
    • 제6권1호
    • /
    • pp.56-62
    • /
    • 1998
  • Mutagenicity of recombinant human erythropoietin (rhEPO) was examined in the reverse mutation test on bacteria, in the chromosomal aberration test on cultured mammalian cells and in the micronucleus test on mice. The reverse mutation test was performed by a plate incorporation method with or wothout a metabolic activation system (59 Mix) using Salmonella typhimurium strain TA100, TA1535, TA98 and TA 1537. The rhEPO did not significantly increase revertant colonies in any of the test strains under any conditions at dose levels ranging from 1000 H/ml to 62.5 lu/plate, compared with the vehicle control. In the chromosomal aberration test using cultured Chinese Hamster Lung (CHL) cells, the number of aberrant cells was not increased in the presence or absence of 59 Mix at concentrations of 1000 lU/ml to 250 lU/ml, compared with the vehicle control. In the micronucleus test, male ICR mice were given rhEPO intraperitoneally at a dose level of 25000, 12500 and 6250 lU/kg. The incidence of bone marrow micronucleated polychromatic erythrocytes was not different from that of the vehicle control. From these results, rhEPO is considered to be non-mutagenic under the present test conditions.

  • PDF

Effects of counter torque and transposition (transfer) of installed implants timing on their integration in dog tibia

  • Karimi, Mohammad Reza;Fathi, Shima;Ghanavati, Farzin
    • The Journal of Advanced Prosthodontics
    • /
    • 제7권1호
    • /
    • pp.62-68
    • /
    • 2015
  • PURPOSE. The purpose of this research was to evaluate the amount of reosseointegration after counter torquing (reverse torque) and transposing the installed implants at different times. MATERIALS AND METHODS. This study was done on ten tibiae of five cross-bred dogs. At the first day one implant was installed in each tibia. After one week half of the implants were randomly counter torqued (1WCT) and the other half were explanted and reimplanted in a new juxtaposition site (transposed)(1WT). At the same time three new implants were installed in each dog, one of them was considered as one week control (1WC) and remaining two as 8 week groups (8WCT&8WT). After eight weeks the 1WCT and 1WT implants were loosened by counter torque and the quantity of needed force for liberation was measured with the digital device (BGI). At the same time one implant was installed in each dog as eight week control (8WC) and the same protocol was repeated for 8 week groups after another 8 weeks. RESULTS. All implants were osseointegrated. Mean quantities of osseointegration in case groups indicated better amounts rather than control groups. CONCLUSION. Counter torque or transposition of the installed implants one week or eight weeks after the implantation did lead to osseointegration.

호버크래프트 추진장치의 컴퓨터 제어기 설계와 동작 (Computer Controller Design and Movement of Hovercraft Driving Apparatus)

  • 백동현;송호빈;조문택
    • 한국화재소방학회논문지
    • /
    • 제25권5호
    • /
    • pp.32-38
    • /
    • 2011
  • 호버크래프트는 수륙양용으로 운용이 가능하고, 일반 보트에 비해 연비가 좋은 관계로 보트의 대체 수단 및 레저용으로 이용이 증가하는 추세이다. 아울러 우리나라도 소방서의 인명구조구급용으로의 수요가 점차 많아지고 있다. 본 논문에서는 호버크래프트의 전진과 후진을 자유롭게 하기 위해 후진 시 방향을 제어할 수 있는 후진 버켓 컴퓨터 시스템 제어기를 개발하였다. 제안한 시스템제어기의 타당성을 입증하기 위하여 Matlab으로 시뮬레이션 한 다음, 실제 소방서에 납품하는 기종에 장착하여 실증 실험을 수행하 였다. 그 결과 호버크래프트는 추진 공기의 흐름에 대하여 좌 우 및 역 추진이 용이하였으며 인명 구조시나 고속 주행시 등에서도 안정된 운용이 가능함을 확인 하였다.

Continuous Conduction Mode Soft-Switching Boost Converter and its Application in Power Factor Correction

  • Cheng, Miao-miao;Liu, Zhiguo;Bao, Yueyue;Zhang, Zhongjie
    • Journal of Power Electronics
    • /
    • 제16권5호
    • /
    • pp.1689-1697
    • /
    • 2016
  • Continuous conduction mode (CCM) boost converters are commonly used in home appliances and various industries because of their simple topology and low input current ripples. However, these converters suffer from several disadvantages, such as hard switching of the active switch and reverse recovery problems of the output diode. These disadvantages increase voltage stresses across the switch and output diode and thus contribute to switching losses and electromagnetic interference. A new topology is presented in this work to improve the switching characteristics of CCM boost converters. Zero-current turn-on and zero-voltage turn-off are achieved for the active switches. The reverse-recovery current is reduced by soft turning-off the output diode. In addition, an input current sensorless control is applied to the proposed topology by pre-calculating the duty cycles of the active switches. Power factor correction is thus achieved with less effort than that required in the traditional method. Simulation and experimental results verify the soft-switching characteristics of the proposed topology and the effectiveness of the proposed input current sensorless control.

비 마약성 진통제 DA-5018의 변이원성 연구 (Mutagenicity of DA-5018, a Non-narcotic Analgesic Agent)

  • 강경구;백남기;김원배;양중익
    • Biomolecules & Therapeutics
    • /
    • 제4권3호
    • /
    • pp.224-231
    • /
    • 1996
  • DA-5018, a non-narcotic analgesic agent, was examined for mutagenicity in the reverse mutation test on bacteria, chromosomal aberration test on cultured mammalian cells and micronucleus test on mice. The reverse mutation test was performed by a plate incorporation method with or without a metabolic activation system(S9 mix) using Salmonella typhimurium strain TA100, TA1535, TA98 and TA1537. DA-5018 did not significantly increase revertant colonies in any of the test strains under any conditions at concentrations ranging from 0.0049 to 1.25 mg/plate, compared with the vehicle control. In the chromosomal aberration test using cultured Chinese Hamster Lung(CHL) cells, DA-5018 did not increase the number of aberrant cells in the presence or absence of S9 mix at concentrations of 0.016 mM/plate to 0.25 mM/plate, compared with the vehicle control. In the micronucleus test, male ICR mice were given DA-5018 intraperitoneally at a dose level of 0.55, 1.10 and 2.20 mg/kg. The incidence of bone marrow micronucleated polychromatic erythrocytes in the DA-5018 treated mice was not significantly different from that of the vehicle control. These results indicate that DA-5018 does not have mutagenic potential under the present test conditions.

  • PDF

천연형 인성장호르몬 DA-3002의 변이원성 연구 (Mutagenicity Study of DA-3002, an Authentic Recombinant Human Growth Hormone(rhGH))

  • 강경구;김옥진;김동환;백남기;안병옥;김원배;양중익
    • Biomolecules & Therapeutics
    • /
    • 제3권4호
    • /
    • pp.294-300
    • /
    • 1995
  • DA-3002, an authentic recombinant human growth hormone(rhGH), was examined for mutagenicity in the reverse mutation test on bacteria, in the chromosomal aberration test on cultured mammalian cells and in the micronucleous test on mice. The reverse mutation test was performed by a plate incorporation method with or without a metabolic activation system(S9 Mix) using Salmonella typhimurium strain TA100, TA1535, TA98 and TA1537. DA-3002 did not significantly increase revertant colonies in any of the test strains under any conditions at dose levels ranging from 0.0125 to 0.4 IU/plate, compared with the vehicle control. In the chromosomal aberration test using cultured Chinese hamster lung(CHL) cells, DA-3002 did not increase the number of aberrant cells in the presence or absence of S9 mix at concentrations of 0.0125 IU/mι to 0.4 IU/mι, compared with the vehicle control. In the micronucleus test, male ICR mice were given DA-3002 intraperitoneally at a dose level of 20, 40 and 80 lU/kg. The incidence of bone marrow micronucleated polychromatic erythrocytes in the DA-3002 treated mice did not differ from that of the vehicle control. These results indicate that DA-3002 doesn't have mutagenic potential under the present test conditions.

  • PDF

Carbonate scale reduction in reverse osmosis membrane by CO2 in wastewater reclamation

  • Shahid, Muhammad Kashif;Pyo, Minsu;Choi, Young-Gyun
    • Membrane and Water Treatment
    • /
    • 제8권2호
    • /
    • pp.125-136
    • /
    • 2017
  • Reverse osmosis technology is being used on large scale for treatment of ground water, brackish water, wastewater and sea water. The most challenging issue in RO process is carbonate scaling which is directly linked with the efficiency and economy. Considering the natural phenomena of carbonate scaling different adaptations have been made to control scaling on the surface of RO membrane including acid dosage and antiscalant addition. As carbonate scaling is directly related with pH level of feed water, present study describes an experimental approach to reduce scaling on RO membrane by lowering the feed water pH by purging $CO_2$. In this comparative study four different conditions including control process (without any scale inhibitor), with dosage of antiscalant, with purging of $CO_2$ and with co addition of antiscalant and $CO_2$ in a feed stream line; it was established that $CO_2$ is a better appliance to reduce carbonate scaling on the membrane surface by reduce pH of feed stream. It was also observed that $CO_2$ and antiscalant mutually function better for scale control.

PARALLEL OPTIMAL CONTROL WITH MULTIPLE SHOOTING, CONSTRAINTS AGGREGATION AND ADJOINT METHODS

  • Jeon, Moon-Gu
    • Journal of applied mathematics & informatics
    • /
    • 제19권1_2호
    • /
    • pp.215-229
    • /
    • 2005
  • In this paper, constraint aggregation is combined with the adjoint and multiple shooting strategies for optimal control of differential algebraic equations (DAE) systems. The approach retains the inherent parallelism of the conventional multiple shooting method, while also being much more efficient for large scale problems. Constraint aggregation is employed to reduce the number of nonlinear continuity constraints in each multiple shooting interval, and its derivatives are computed by the adjoint DAE solver DASPKADJOINT together with ADIFOR and TAMC, the automatic differentiation software for forward and reverse mode, respectively. Numerical experiments demonstrate the effectiveness of the approach.

Myopia Control Lens, Single Vision Lens, Reverse Geometry Contact Lens의 연령에 따른 굴절교정상태 변화에 대한 추적 연구 (Changes of Refractive Correction Value with Different Age Group: A Case for Myopia Control Lens, Single Vision Lens and Reverse Geometry Contact Lens)

  • 윤민화
    • 한국안광학회지
    • /
    • 제18권1호
    • /
    • pp.75-84
    • /
    • 2013
  • 목적: 연령에 따라 역기하콘택트렌즈(reverse geometry contact lens), MC렌즈(myopia control lens)를 착용 한 후 근시진행억제 효과에 대한 굴절교정값의 변화를 단초점렌즈(single vision lens)와 비교해 알아보고자 한다. 방법: 6세에서 15세 사이의 아동에게 역기하콘택트렌즈 57안, MC렌즈 56안, 단초점렌즈 78안을 각각 착용시킨 후 연령에 따라 Group 1은 10세 이하, Group 2는 11세에서 15세 이하, Group 3은 연구 대상을 모두 포함하여 3그룹으로 나눴다. 이를 바탕으로 12개월 이하, 13~24개월, 25~36개월 까지 굴절교정값의 변화를 통한 근시 진행 억제 효과를 알아보고 통계적 유의성을 검증하고자 하였다. 결과: 착용기간에 따른 굴절교정값의 변화는 Group 3에서 12개월 이하에서는 역기하콘택트렌즈를 착용한 아동에서 변화가 없었고, MC렌즈는 $-0.36{\pm}0.10$ D, 단초점렌즈는 $-0.67{\pm}0.52$ D가 유의하게 변화되었다(P<0.05). 13~24개월에서 역기하콘택트렌즈는 $0.18{\pm}0.49$ D, MC렌즈는 $0.60{\pm}0.42$ D, 단 초점렌즈는 $1.37{\pm}0.72$ D로 유의(P<0.05)하게 변화되었다. 25~36개월에서 역기하콘택트렌즈는 $0.29{\pm}0.61$ D, MC렌즈는 $0.93{\pm}0.57$ D, 단초점렌즈는 $1.72{\pm}0.78$ D로 유의(P<0.05)하게 변화되었다. Group 1에서는 36개월 까지 역기 하콘택트렌즈는 $0.29{\pm}0.73$ D로 MC렌즈는 $1.07{\pm}0.59$ D로 단초점 렌즈는 $1.75{\pm}0.74$ D로 유의(P<0.05)하게 증가하였으며 Group 2에서는 36개월 까지 역기하콘택트렌즈는 $0.28{\pm}0.42$ D로 MC렌즈는 $0.75{\pm}0.49$ D로 단초점 렌즈는 $1.70{\pm}0.84$ D로 유의(P<0.05)하게 증가하여 굴절교정값의 변화는 10세 이하가 11세 이상보다 유의(P<0.05)하게 큰 것으로 나타났다. 결론: 본 연구 결과 12개월 이하의 착용시 역기하콘택트렌즈는 모든 연령에서 굴절교정값의 변화가 없었고, MC렌즈는 모든 연령에서 단초점렌즈보다 더 낮은 시력변화폭을 나타내 근시진행의 억제효과가 있으며, 13~36개월 착용시 역기하콘택트렌즈와 MC렌즈는 모든 연령에서 단초점렌즈보다 낮은 시력변화를 보여 근시진행의 억제효과가 있는 것으로 사료된다.