• Title/Summary/Keyword: Reverberation times

Search Result 37, Processing Time 0.023 seconds

The relevancy between physical index and subjective appraisal of class (강의실내의 물리지표와 주관적평가와의 상관관계)

  • Lee, Chai-Bong;Kim, Yong-Man
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.11a
    • /
    • pp.374.1-374
    • /
    • 2002
  • The eventual purpose of this research is to make optimum standards for acoustic-environment by using not only physical characteristics but also subjective appraisals. First, basic Physical data were measured which were necessary to establish standards for acoustic environment in campus buildings, TSP has used to measure sound levels, reverberation times, clearness indexes, and speech-transmission-index. (omitted)

  • PDF

The Application of 1-Dimensional Diffusers in Classroom Acoustics (1차 단순 확산체를 적용한 교실음향설계)

  • Choi, Young-Ji
    • Journal of the Korean Institute of Educational Facilities
    • /
    • v.18 no.5
    • /
    • pp.3-11
    • /
    • 2011
  • In this study, the effect of treating 1-dimensional diffusers on the classroom acoustics was investigated to determine if the diffuser are beneficial for performing the preferred acoustical conditions for speech. A 1/10 scale model of a classroom was used to measure the acoustical parameters, T30, $C_{50}$, STI and SNR in that room. The room acoustical conditions were varied by treating diffusers either on the front or side walls of the classroom. When the diffusers were treated on the side walls around the student's areas, a shorter reverberation time at low frequencies was obtained and resulted in performing uniform reverberation times across the frequency bands. The $C_{50}$ values at mid- and high-frequencies were increased by treating the diffusers either on front or side wall surfaces. The highest STI and SNR values were obtained when the diffuser was treated on the front wall around the teacher's areas. It is found that diffusers are beneficial to increase the intelligibility of speech for the rear seats of the rooms.

  • PDF

A Study on the Errors at the Measurement of Sound Power (음향파워 측정 시 오차에 대한 고찰)

  • Na, Hae-Joong;Lim, Byoung-Duk
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.22 no.10
    • /
    • pp.917-924
    • /
    • 2012
  • Noise power of large machineries, such as textile looms, winders, and twisting machines, is often measured in a reverberant space because they cannot be installed and operated in an anechoic chamber due to their size, weight, and operating conditions. Factors affecting the measurement error of an in-situ noise power measurement include the nonuniform reverberation time and the direction of sound intensity vector which is usually regarded as normal to the measurement surface. In this study errors due to these factors are estimated with the aid of numerical simulation based on the ray-tracing technique. The averaging of reverberation times measured at several points on the measurement surface is suggested to reduce the errors from nonuniform absorption. Also the direction cosine of each surface element is taken into account, which as a whole is represented as a solid angle of the measurement surface.

Room Acoustic Measurement System Using Impulse Response (임펄스응답을 이용한 실내음향 측정 시스템)

    • The Journal of the Acoustical Society of Korea
    • /
    • v.18 no.5
    • /
    • pp.63-67
    • /
    • 1999
  • Recently, a method of measuring impulse response is widely used for a room acoustic evaluation instead of measuring reverberation time by white noise excitation. Comparing with the traditional reverberation time measurement, this method has many advantages such as good repeatability and the ability to extract various room acoustic parameters at one measurement. In this study, the author developed a measuring system that can extract mono-aural room acoustic parameters from an impulse response measured with MLS (Maximum Length Sequence) signal excitation. These room acoustic parameters include reverberation times(EDT, RT), speech intelligibilities(C50, C80, D, U50, U80, AI) and sound strength(G). This paper introduces the configuration of the developed measuring system, test results and discussions for the measurements at several rooms.

  • PDF

Noise and Room Acoustic Conditions in a Tertiary Referral Hospital, Seoul National University Hospital

  • Cho, Wan-Ho;Jeong, Cheol-Ho;Chang, Ji-Ho;Lee, Seong-Hyun;Park, Moo Kyun;Suh, Myung-Whan;Han, Jae Joon
    • Journal of Audiology & Otology
    • /
    • v.23 no.2
    • /
    • pp.76-82
    • /
    • 2019
  • Background and Objectives: Noise levels and room acoustic parameters at a tertiary referral hospital, Seoul National University Hospital (SNUH) in Korea, are investigated. Materials and Methods: Through a questionnaire, acoustically problematic rooms are identified. Noise levels in emergency rooms (ERs) and intensive care units (ICUs) are measured over about three days. Acoustically critical and problematic rooms in the otolaryngology department are measured including examination rooms, operating rooms, nurse stations, receptions, and patient rooms. Results: The A-weighted equivalent noise level, LAeq, ranges from 54 to 56 dBA, which is at least 10 dB lower than the noise levels of 65 to 73 dBA measured in American ERs. In an ICU, the noise level for the first night was 66 dBA, which came down to 56 dBA for the next day. The noise levels during three different ear surgeries vary from 57 to 62 dBA, depending on the use of surgical drills and suctions. The noise levels in a patient room is found to be 47 dBA, while the nurse stations and the receptions have high noise levels up to 64 dBA. The reverberation times in an operation room, examination room, and single patient room are found to be below 0.6 s. Conclusions: At SNUH, the nurse stations and receptions were found to be quite noisy. The ERs were quieter than in the previous studies. The measured reverberation times seemed low enough but some other nurse stations and examination rooms were not satisfactory according to the questionnaire.

Noise and Room Acoustic Conditions in a Tertiary Referral Hospital, Seoul National University Hospital

  • Cho, Wan-Ho;Jeong, Cheol-Ho;Chang, Ji-Ho;Lee, Seong-Hyun;Park, Moo Kyun;Suh, Myung-Whan;Han, Jae Joon
    • Korean Journal of Audiology
    • /
    • v.23 no.2
    • /
    • pp.76-82
    • /
    • 2019
  • Background and Objectives: Noise levels and room acoustic parameters at a tertiary referral hospital, Seoul National University Hospital (SNUH) in Korea, are investigated. Materials and Methods: Through a questionnaire, acoustically problematic rooms are identified. Noise levels in emergency rooms (ERs) and intensive care units (ICUs) are measured over about three days. Acoustically critical and problematic rooms in the otolaryngology department are measured including examination rooms, operating rooms, nurse stations, receptions, and patient rooms. Results: The A-weighted equivalent noise level, LAeq, ranges from 54 to 56 dBA, which is at least 10 dB lower than the noise levels of 65 to 73 dBA measured in American ERs. In an ICU, the noise level for the first night was 66 dBA, which came down to 56 dBA for the next day. The noise levels during three different ear surgeries vary from 57 to 62 dBA, depending on the use of surgical drills and suctions. The noise levels in a patient room is found to be 47 dBA, while the nurse stations and the receptions have high noise levels up to 64 dBA. The reverberation times in an operation room, examination room, and single patient room are found to be below 0.6 s. Conclusions: At SNUH, the nurse stations and receptions were found to be quite noisy. The ERs were quieter than in the previous studies. The measured reverberation times seemed low enough but some other nurse stations and examination rooms were not satisfactory according to the questionnaire.

Field Distribution Characteristics of a Reverberation Chamber with 2D Diffuser Sets (2D 확산기를 이용한 전자파 잔향실 내의 필드 분포 특성)

  • Yang Wook;Rhee Joong-Geun
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.16 no.4 s.95
    • /
    • pp.373-379
    • /
    • 2005
  • Papers on improvement of electromagnetic field uniformity in a reverberation chamber with 1D Quadratic Residue Diffuser of Schroeder method has been published several times. In this paper, to obtain improved electromagnetic field characteristics and field uniformity in a reverberation chamber, cubical residue diffuser sets of Schroeder type are designed for a chamber in $2.3\;\cal{GHz}\~3\;\cal{GHz}$. The FDTD(Finite-Difference Time-Domain) technique is used to analyze the field characteristics in a chamber. Cubical residue algorithm and 2D arrangement show more randomness than the previous study results. The characteristics of tolerance, polarity, deviations, as well as power efficency, are improved with cubical residue diffuser sets in a chamber.

Effects of reverberation time on binaural Korean monosyllabic word recognition in normal hearing subjects (잔향시간이 양이를 사용한 한국어 단음절 인지에 미치는 영향)

  • Lim, Dukhwan
    • The Journal of the Acoustical Society of Korea
    • /
    • v.40 no.6
    • /
    • pp.678-682
    • /
    • 2021
  • Reverberation Time (RT) with noise levels can affect speech recognition ability in a listening environment. The degree of influence may depend on reverberation times and modes of binaural hearing. In this study, Korean monosyllabic Word Recognition Scores (WRS) were investigated in 10 young normal hearing subjects under binaural conditions. The RT of 3.4 s and signal to noise ratio of 0 dB were used at 55 dB HL for diotic (noise with the same phase) and dichotic (noise with the fixed phase difference, π) conditions. The improvement in WRS was noted in dichotic hearing (p < 0.05) while the similar trend was not observed in diotic hearing. This data may be useful in analyzing psychoacoustic effects of RTs under noisy conditions.

Towards better acoustic conditions in school buildings in Korea-a need for Korean standard for classroom acoustics (국내 교육시설의 음향기준 제정의 필요성 제고)

  • Young-Ji Choi
    • The Journal of the Acoustical Society of Korea
    • /
    • v.42 no.2
    • /
    • pp.113-123
    • /
    • 2023
  • This paper describes the acoustical conditions of elementary school and high school classrooms as well as university classrooms in Korea and suggests a need for Korean acoustic standards and guidelines for classroom design. Current standards and guidelines of classroom acoustics in several countries were briefly introduced to understand their acoustical performance criteria for background noise levels and reverberation times, and noise isolation design requirements in various types of classrooms. The results of several acoustic survey of domestic classrooms in elementary school, high school, and university were described and compared to provide information of the acoustic characteristics of Korean school classrooms. The survey includes occupied and unoccupied data on the acoustical conditions, noise levels, and noise isolation performance in the classrooms. Acoustical parameter values for achieving 'good' speech intelligibility in active university classrooms were also presented.

The relevancy between Physical index and subjective appraisal of classrooms (강의실 내의 물리지표와 주관적 평가와의 상관관계)

  • Lee, Chai-Bong;Kim, Yong-Man
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.11b
    • /
    • pp.743-748
    • /
    • 2002
  • The eventual Purpose of this research is to make optimum standards for acoustic-environment by using not only physical characteristics but also subjective appraisals. Basic physical data were measured which were necessary to establish standards for acoustic environment in campus buildings, TSP has used to measure sound levels, reverberation times, clearness indexes, and speech-transmission-index. In addition to physical characteristics, questionnaires were given to university students to given subjective appraisals. For instance, questions about volume or clearness of lectures. The relevancy between physical characteristics and subjective appraisals was studied.

  • PDF