• 제목/요약/키워드: Reverberation room

검색결과 153건 처리시간 0.028초

조선 궁궐 건축물의 음향성능 측정 및 평가 - 편전 및 침전을 중심으로 - (Measurement and Evaluation of the Acoustic Performance in the Royal Palace Buildings of Joseon Dynasty - Focused on Pyeonjeon and Chimjeon -)

  • 김남욱;김명준;한욱
    • 한국소음진동공학회논문집
    • /
    • 제19권12호
    • /
    • pp.1269-1280
    • /
    • 2009
  • This study was performed to construct sound performance DB of royal palace buildings and to examine the special quality more scientifically. Research target of royal palace were Changdeokgung and Gyeongbokgung. Sound insulation performance between the adjacent room and facade, room acoustics of Pyeonjeon and Chimjeon which is representative building in royal palace were examined through field measurement. Measured values of RT($T_{mf}$) at Pyeonjeon were 0.78 sec. and 1.03 sec. in Seonjeongjoen and Sajeongjoen, respectively. The RTs of both Pyeonjeon buildings were estimated suitable for speech and lecture considering their volume. The RT($T_{mf}$)s at Chimjeon were measured in range of 0.29~0.55 sec. This meant that the acoustic energy in rooms was decreased by sound transmission through mulberry paper(Hanji) of traditional windows and doors. As a sound insulation performance, the single-number quantities($D_{ls,2m,nT,w}$) of the building facades in Pyeonjeon and Chimjeon were measured 4~20 dB. Also the single-number quantities($D_{p,w}$) between the adjacent rooms in Chimjeon were measured 3~18 dB. Sound insulation performance of traditional building elements such as window and door depended strongly on their layers and area.

헬리컬 코일 스프링 잔향기의 디지털 필터 모델 (Digital Filter Model for Analog Helical Coil Spring Reverberator)

  • 박준;전상배;이종훈;성굉모;송상섭
    • 한국음향학회지
    • /
    • 제25권6호
    • /
    • pp.291-297
    • /
    • 2006
  • 본 논문에서는 기타 앰프에 사용되는 아날로그 헬리컬 스프링 잔향기를 디지털 필터로 모델링하는 기법에 대하여 소개한다. 기존의 디지털 잔향기들이 실내 음향 기반의 음장모드를 제공하는데에 비하여, 본래의 헬리컬 스프링 잔향기 자체에 대한 분석과 모델링 없이 아직도 실질적으로 기타앰프의 $70{\sim}80%$ 정도가 헬리컬 잔향기를 사용하기에, 실내 음향학적 접근이 아닌 헬리컬 스프링 잔향기 자체를 하나의 이펙터로 간주하고 이를 모델링하는 데에 초점을 두고 연구를 진행하였다. 제안된 알고리즘으로 구현한 디지털 필터로 시뮬레이션을 수행하여 청취평가를 수행한 결과, 기존의 아날로그 헬리컬 스프링 잔향기와 인지적으로 구분할 수 없는 매우 유사한 특성을 나타내는 것을 확인하였다.

통기성을 갖는 막재료의 흡음특성 (Sound Absorption Characteristics of Permeable Membrane)

  • 정정호;김정중;김규제
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2009년도 추계학술대회 논문집
    • /
    • pp.270-275
    • /
    • 2009
  • Sound absorption characteristics of membrane system which are used in stadiums and arenas were investigated. Theoretical studies on acoustic properties of single and double leaf permeable membrane conducted. Also, experimental studies on sound absorption characteristics of combined membrane system that is composed of outer and inner membrane material were conducted. In this study, sound absorption characteristics of each membrane were investigated by experiments in reverberation chamber. 4 types of permeable membranes and a non-permeable membrane were used for experiments. Air space behind membrane material and tension on the membrane was varied. Sound absorption performance of permeable membrane materials was confirmed. As increasing air space behind the membrane material, sound absorption coefficient was increased. In a resonance absorption frequency band sound absorption coefficient varied more dramatically. Sound absorption characteristics were flat in mid and high frequency range and sound absorption coefficient was from 0,3 to 0,5. Also sound absorption coefficient was increased by the increment of surface density and air permeability of membrane. However, over the certain value of air permeability, sound absorption coefficient was decreased. These results can be used as design factors and method for the room acoustic design of dome-stadiums and large free-form buildings.

  • PDF

창호지의 흡음성능에 관한 실험적 연구 (Sound Absorption Performance of Korean Traditional Window Papers)

  • 최은석;이태강;김항;김선우
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2006년도 추계학술대회논문집
    • /
    • pp.17-20
    • /
    • 2006
  • Korean traditional houses have been developed in sympathy with natural environment and formed comfortable indoor condition by properly using surrounding natural resources including building layout, space construction and material our traditional wooden windows adjusting ambient temperature and humidity have both the functions of window and door, although they are clearly divided in the West. While window paper is attached from the outside in China and Japan, it is attached from the inside in Korea. The opening and closing mode of windows is similar and their dimensions are shown not to he standardized but diverse in terms of the characteristic of wooden furniture and that of components placed between columns. Thus this study is to look into the performance of band-lattice door of a typical traditional one by observing changes in sound absorption characteristics according to difference in thickness and finishing method of window paper and those in sound absorption characteristics with the changed thickness of air layer in traditional windows and doors.

  • PDF

랜덤입사방법에 의한 포러스 콘크리트의 흡음특성에 관한 실험적 연구 (The Study on Sound Absorbing Characteristics of Porous Concrete according to Reverberation Room Methods)

  • 서대석;박승범;조광연;장영일;김형석;이윤선
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2004년도 춘계 학술발표회 제16권1호
    • /
    • pp.568-571
    • /
    • 2004
  • This research estimated the physical. mechanical characteristic and the character of sound absorption according to target void ratio of porous concrete and the mixing ratio of recycled aggregate for the valid utilization of recycled aggregate using waste concrete and sound reduction out of a road, a railway, a residential street, and a downtown area. As a result of the test, compressive strength tended to be a radical strength fall when target void ratio was $25\%$ and contents of recycled aggregate exceeded over $50\%$. Also, the character of sound absorption of porous concrete which used recycled aggregate using waste concrete was the most excellent when target void ratio was $25\%$, and the influence by contents of recycled aggregate was trivial. Therefore, when the strength and the character of sound absorption of porous concrete are considered, it is proved valid that proper target void ratio was $25\%$ and contents of recycled aggregate using waste concrete was $50\%$ or so.

  • PDF

음향 시뮬레이션을 이용한 돔형 체조연습장의 음향성능 개선 (Acoustic Performance Improvement for Dome-typed Gymnastics Training Floor using Acoustic Simulation)

  • 윤재현;정철운;국정훈;김재수
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2007년도 춘계학술대회논문집
    • /
    • pp.696-700
    • /
    • 2007
  • In case of dome-typed gymnastics training floor, since its form takes shape of the focus of sound, in the occasion when the finishing-material was used with the sandwich panel that prominent in reflexibility, and because the reverberation of sound in indoor is too loud, a smooth practice and teaching is very difficult. As this indoor gymnastics training floor, standing at its character, is required simultaneously the idea communication between the player and the coach, and the acoustic capability regarding to the clearness of music, besides the sport activity, the method to minimize the acoustic defect should be urgently contrived from the stages of design and beginning of construction. On this viewpoint, after investigation on the confidence of the surveyed value and the estimated value using acoustic simulation, and use of the changed finish-material, this thesis intends to design the dome-typed gymnastics training floor that secured the optimized acoustic condition. It is also considered that such result of the study could be utilized as the useful data that enables to improve the retrenchment effect of the construction cost as well as the acoustic performance, by means of the prediction control on the acoustic problem from the stage of design, for the occasion when the similar indoor sport gymnasium is planning to build for the near future.

  • PDF

단일수치 평가방법에 따른 방음벽의 흡음성능 고찰 (Sound Absorption Performance of Noise Barrier According to Single Number Rating Methods)

  • 김용희;이성찬
    • 한국소음진동공학회논문집
    • /
    • 제27권2호
    • /
    • pp.243-250
    • /
    • 2017
  • In this study, single number rating methods of sound absorption coefficients are discussed. After that the sound absorption performance of noise barriers which are classified by Korea Standard are analyzed according to several standards. The existing rating methods such as NRC (noise reduction coefficient), SAA (sound absorption average) or ${\alpha}_w$ (weighted sound absorption coefficient) from ASTM C423, KS F 3505 and ISO 11654 are introduced. The sound absorption performance of noise barrier is evaluated to compare NRC and ${\alpha}_w$ value. When the value is over 0.6 there are large variance between NRC and ${\alpha}_w$ value. As results, it is needed to unify single number rating methods of sound absorption coefficients for Korean standards on sound absorbing materials.

음 감쇠 측정에서 측정 오차 개선을 위한 웨이블렛 필터 설계 (Design of a Wavelet Filter for Experimental Error Improvement on Acoustic Decay Measurements)

  • 이민성;이상권;김봉기
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2001년도 춘계학술대회논문집
    • /
    • pp.991-996
    • /
    • 2001
  • It is well known that there are two experimental errors on acoustic decay measurements. One is due to the influence of the band pass filter the other one is that of an averaging device. In this paper the influence of the filter is in detail investigated. To minimize the influence of filter, the product of the filter bandwidth Β (3㏈ bandwidth) and the reverberation time T$\sub$60/ of the room under test is at least 16. Moreover, if the initial part of an acoustic decay curve is important, the strong requirement, i.e. BT$\sub$60/> 64, must be satisfied. In this paper, the wavelet filter bank instead of the band pass filter bank is applied to obtain an acoustic decay curve. As results, the influence of filter is reduced and then the value of BT$\sub$60/ required for obtaining an acceptable decay curve is at least 4. The strong requirement for the initial part of a decay curve is also replaced by the BT$\sub$60/> 16 instead of BT$\sub$60/> 64.

  • PDF

다공 초음속 분류소음에 관한 실험적 연구 (An Experimental Study on the Supersonic Jet Noise from Multihole)

  • 권영필;서기원
    • 설비공학논문집
    • /
    • 제4권2호
    • /
    • pp.96-105
    • /
    • 1992
  • The objective of this paper is to study experimentally on the noise characteristics of supersonic jet from multihole orifice in the range of jet pressure from $at_g$ to $at_g$ in the reverberation room. At first, the single orifice jets are investigated for various hole diameter from 3.8mm to 10mm. Through the noise spectrum, the turbulent mixing noise and the shock associated noise is analyzed. The noise for confined jets into a tube of diameter 30mm or 90mm with length 2m is investigated in comparision with that for the free jets. The sound power level is measured and compared with thoretical models for free jet. At second, multihole orifice jets are investigated to study the effect of multijet on noise reduction. The spectrum and power level of multijets are measured and compared with single jets. The multi-jets in a confined pipe are also investigated. It is found that the noise spectrum is significantly altered by increasing the number of jet with decrease in jet diameter and also by confining the jet into tube.

  • PDF

금속 및 샌드위치 복합재 유도탄 구조체의 흡음 및 차음 특성에 관한 실험적 연구 (Experimental Study on Acoustic Absorption and Transmission Characteristics of Aluminium and Sandwich Composite Structure)

  • 이윤규;이대은;진병대;이동민
    • 한국군사과학기술학회지
    • /
    • 제21권3호
    • /
    • pp.288-294
    • /
    • 2018
  • Recently, as the speed and performance of the launcher and the missile have been improved, it is necessary to consider the acoustic load of launching and flight in initial design step. In this paper, an experimental study on acoustic absorption and transmission characteristics of aluminium vs. sandwich composite structures were conducted. The overall noise reduction was evaluated by performing an acoustic test in the reverberation room, and the acoustic absorption and transmission loss of the structures were analyzed by conducting the sound absorption test inside the structure.