• 제목/요약/키워드: Reuse Water

검색결과 494건 처리시간 0.022초

에너지 자립형 MBR, A/O 공정의 효율 평가 (Efficiency evaluation of MBR, A/O processes utilizing self-sufficient energy)

  • 임세택;김진근
    • 상하수도학회지
    • /
    • 제28권3호
    • /
    • pp.305-314
    • /
    • 2014
  • A pilot plant (Q=5 $m^3/d$) study was implemented for small and medium sized personal wastewater treatment plant effluent to evaluate MBR and A/O processes utilizing self-sufficient energy composed of wind and solar energy. The removal efficiencies of BOD, SS, turbidity and color were sufficient for legal water quality standards for gray water. However, those of nitrogen and phosphorus could not meet legal regulations which suggested that further removal of those contaminants were needed for reuse of the treated water. Self-sufficient energy rate was 100 % for the pilot plant due to excessive design capacity. In this research, wind and solar energy system was applied considering geological characteristics, which significantly improved energy self-sufficiency. Substantial improvement on energy self-sufficiency can be obtained by optimized investment and operation at a full scale wastewater treatment plant.

SWAT-QUALKO2 연계 모형을 이용한 관개기 순별 관개수질 모의 (Simulation of 10-day Irrigation Water Quality Using SWAT-QUALKO2 Linkage Model)

  • 김지혜;정한석;강문성;송인홍;박승우
    • 한국농공학회논문집
    • /
    • 제54권6호
    • /
    • pp.53-63
    • /
    • 2012
  • The objectives of this study were to develop a linked watershed-waterbody modeling system and to assess the impacts of indirect wastewater reuse on irrigation water quality. The Osan stream watershed within Gyeonggi-do of South Korea was selected for this study. The linked modeling system was composed of the SWAT (Soil and water assessment tool) and QUALKO2 models. The SWAT model was calibrated and validated using the stream discharge and water quality data from 2010 to 2011. Runoff and non-point source pollutants from each subbasin and stream discharge from 1980 to 2009 were simulated by the SWAT model and applied to the QUALKO2 model. The QUALKO2 model was calibrated and validated under the conditions of low water and normal discharges, respectively. Finally, The 10-day irrigation water quality from April to September was simulated. The statistical measures of coefficient of determination ($R^2$), reliability index (RI), and efficiency index (EI) were used to evaluate the system performance. The $R^2$, RI and EI values ranged from 0.5 to 1.0, 1.03 to 1.92, and -35.03 to 0.95, respectively. The 10-day irrigation water quality showed the concentrations of BOD and coliform exceeded the water quality guidelines for wastewater reuse. The linked modeling system can be a useful tool to estimate non-point source pollutant loads in watershed and to control the water quality of effluent from a wastewater treatment plant and irrigation water in the downstream waterbody.

건축물의 중수도 설치기준에 대한 제도적 개선방안 (An Institutional Improving Standards for Water Reclamation/Reuse(WRR) System Establishment to Buildings)

  • 공영효
    • KIEAE Journal
    • /
    • 제6권3호
    • /
    • pp.43-48
    • /
    • 2006
  • This paper aims to suggest ways of institutionally improving standards that must be applied when installing Water Reclamation/Reuse (WRR) system based on efficiency analysis. Currently, the standard for WRR system establishment requires that the system should treat more than 10% of used water in the building of over $60,000m^2$ in total area of all floors, but our research has found that it would be more effective to change the standard to $150-m^3-per-day$ reclaimed water or the total area of all floors of $30,000m^2$ ($50,000m^2$ in the case of an office building). In other words, what this paper suggests is not a one-size-fits-all standard based on the total area of all floors, but a reasonable and flexible standard that takes into account efficiency and a unit water usage according to a building's purpose. Furthermore, this paper recommends a new WRR standard that can be applied to large-scale land development for housinglots, like the New Town. The recommendation is based on the economic analysis that the WRR system will ensure efficiency only if the amount of reclaimed water is over 4,000 tons per day, which corresponds to 4 millions square meters of housinglots. Regarding the size of the established facility, this paper suggests changing the standard, which is now set at over 10% of water usage, to what is relative to the total amount of use of reclaimed water in order to ensure efficiency and promote use of reclaimed water. In addition, this paper proposes that governmental support should be offered not only to facility owners, who are recipients at present, but also to facility builders. By doing so, those who donate a facility to the government, central or local, after building it, can be provided with substantial aid. Therefore, the application of the institutional improvement suggested in this paper is expected to create environment-friendly living conditions and boost the quality of life by encouraging people to secure water resources efficiently in buildings, and in a wider range, in cities.

하수처리수의 농업용수 재이용을 위한 관개수량 산정방법에 관한 연구 (A Study on the Estimation of Irrigation Water for Sewage Treated Water Reuse for Agriculture)

  • 조현경;김상민
    • 한국농공학회논문집
    • /
    • 제61권2호
    • /
    • pp.97-104
    • /
    • 2019
  • The purpose of this study was to establish the estimation method of irrigation water amount for sewage treated water reuse for agricultural purpose. To calculate the irrigation water amount, we adopted Penman-Monteith for potential evapotranspiration estimation and applied crop coefficient and irrigation efficiency factor. We developed the irrigation water amount calculation program using C language in Xcode environment. The target district for calculation is having 259 ha of agricultural land located near the Jinyeong Clear Water Circulation Center in Hanrim-myeon, Gimhae city. The meteorological data of the study area were obtained from Changwon weather station from 1986 to 2017. Calculated average and maximum of annual mean potential evapotranspiration were 2.72 mm/day and 6.22 mm/day, respectively. We used K-S (Kolmogorov-Smirnov) for goodness-of-fit test to find optimal probability distribution of annual mean and maximum evapotranspiration. As a result, the normal distribution was selected for the appropriate distribution. The annual mean and maximum potential evapotranspiration for 10-year return period by applying normal distribution were 2.88 mm/day and 6.76 mm/day, respectively. Assuming that the irrigation efficiency is 80%, the irrigation water requirement was calculated as $36.05m^3/day/ha$ and $84.45m^3/day/ha$, respectively, when annual mean and maximum potential evapotranspiration were applied. The actual irrigation water amount can be calculated by applying the crop coefficient and cropping days for the study area based on the developed irrigation water amount estimation program in this study.

GIS를 이용한 농업용수 재이용 활용시스템 개발 (Development of GIS System for Agriculture Reuse of Wastewater Resource)

  • 김해도;이광야;정광근;이종남
    • 한국농공학회:학술대회논문집
    • /
    • 한국농공학회 2005년도 학술발표논문집
    • /
    • pp.479-484
    • /
    • 2005
  • A GIS-based integrated system for reuse of effluent from wastewater treatment plants was developed in this study. The GIS-supported program classified attribute data which the effluent's quantity and quality and agricultural thematic map data according to the 5 big river basin area. From the database, showing the spatial variation of the water quality of the effluent, thereby proposing proper mitigation strategies over the watershed. Also, this system enables the users who is going to reuse the reclaimed water for their paddies to provide of all the wastewater treatment plant data and agricultural structures and thematic map data.

  • PDF

Organic fouling in forward osmosis (FO): Membrane flux behavior and foulant quantification

  • Xia, Shengji;Yao, Lijuan;Yang, Ruilin;Zhou, Yumin
    • Membrane and Water Treatment
    • /
    • 제6권2호
    • /
    • pp.161-172
    • /
    • 2015
  • Forward osmosis (FO) is an emerging membrane technology with potential applications in desalination and wastewater reclamation. The osmotic pressure gradient across the FO membrane is used to generate water flux. In this study, flux performance and foulant deposition on the FO membrane were systematically investigated with a co-current cross-flow membrane system. Sodium alginate (SA), bovine serum albumin (BSA) and tannic acid (TA) were used as model foulants. Organics adsorbed on the membrane were peeled off via oscillation and characterized by Fourier transform infrared (FTIR) spectroscopy and scanning electron microscopy (SEM). When an initial flux of $8.42L/m^2h$ was applied, both flux reduction and foulant deposition were slight for the feed solution containing BSA and TA. In comparison, flux reduction and foulant deposition were much more severe for the feed solution containing SA, as a distinct SA cake-layer was formed on the membrane surface and played a crucial role in membrane fouling. In addition, as the initial SA concentration increased in FS, the thickness of the cake-layer increased remarkably, and the membrane fouling became more severe.

하수재이용 막여과 공정에서 막오염 저감을 위한 마이크로버블 적용성 평가 (Applicability evaluation of microbubble for membrane fouling reduction in wastewater reuse membrane process)

  • 이창하;김건엽;김형수;김지훈;이경일
    • 상하수도학회지
    • /
    • 제31권2호
    • /
    • pp.169-175
    • /
    • 2017
  • This study applied microbubbles to reduce membrane fouling in wastewater reuse membrane processes, evaluated and compared the transmembrane pressure with or without the application of microbubbles and the cleaning efficiency with the application of aeration and microbubbles. In addition, this study analyzed foulants removed from the membrane surface. Changes in the transmembrane pressure of membranes with the presence or absence of microbubbles were observed. As a result, transmembrane pressure (TMP) increasing rate decreased twofold when applying microbubbles to realize stable operations. This study compared and evaluated cleaning efficiency applying aeration and microbubbles. As a result, the cleaning efficiency was 5% higher on average when applying microbubbles. In turbidity and total organic carbon (TOC), foulants were discharged when applying microbubbles twice as much as applying aeration. It is thought that particulate foulants precipitated on the membrane surface were more likely to desorb because the adhesion between the membrane surface and particle was weakened by microbubbles. Therefore, it is considered possible to effectively control membrane fouling because of the increase in cleaning efficiency when applying microbubbles to wastewater reuse membrane processes.

얕은 불포화 및 포화 대수층을 모사한 SAT 토양칼럼에서의 하수처리장 방류수 처리 수질 변화 (Water Quality Changes in Wastewater Effluent from the Unsaturated and Saturated Soil Aquifer Treatment(SAT) Columns Simulating Shallow Aquifer)

  • 차우석;김정우;최희철;원종호;김인수;조재원
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제10권5호
    • /
    • pp.18-24
    • /
    • 2005
  • 본 연구에서는 얕은 불포화 및 포화 대수층을 모사한 실험실 규모의 SAT 토양 칼럼을 약 5개월간 운전하면서 얕은 대수층 조건에서 하수처리장 방류수의 처리수질 변화를 알아보고자 하였다. 유기물 (DOC)의 평균 제거율은 불포화 (unsaturated SAT) 칼럼의 경우 31.9%굶 높게 나타난 반면, 포화(saturated SAT) 칼럼에서는 DOC가 거의 제거되지 않았다. 얕은 대수층 조건을 모사한 불포화 토양 칼럼에서의 질산화는 충분하지 않은 것으로 나타났으며 잔류 암모니아가 포화대수층으로 유입되었다. 또한 얕은 불포화 칼럼에서의 짧은 체류시간(1 day)으로 인해 포화 칼럼 유입수의 DO가 약 2 mg/L를 유지했다. 인 (phosphate)은 불포화 칼럼에서는 제거되지 않고 그대로 유출되는 특성을 보였고, 포화 칼럼에서는 100% 제거되는 특성을 보였다. 결론적으로, 암모니아성 질소가 포화층으로 유입되고, 포화층 유 입수의 DO가 상대적으로 높다는 점을 제외하면 얕은 대수층 조건에서도 유기물 및 질소, 인의 제거가 충분하게 일어남을 알 수 있었다.

자연정화방법에 의한 오수처리와 농업적 재이용 타당성 검토 (Feasibility Study of Natural Systems for Sewage Treatment and Agricultural Reuse)

  • 윤춘경;정광욱;함종화;전지홍
    • 한국농공학회지
    • /
    • 제45권6호
    • /
    • pp.194-206
    • /
    • 2003
  • A pilot study was performed to examine the feasibility of the pond system for further polishing of treatment wetland effluent to agricultural reuse of reclaimed water. The constructed wetland and pond system was installed in Konkuk University and the effluent from septic tank of school building was used as an influent to the wetland system. The effluent of the wetland was used as an influent to pond systems. The influent concentrations of total coliform(TC), fecal coliform (FC), and E. coli were about $10^5$MPN/100 ml, and they were reduced to less than 10,000 MPN/100 ml on average after wetland treatments, showing over 95 % removal. And they were further reduced to less than 1,000 MPN/100 ml in average, showing over 85∼93 % removal after pond treatment. Turbidity and SS were improved effectively on average and their pond effluent concentration was about 4.5 NTU and 9.8 mg/L in average, respectively Average $BOD^5$ concentrations were also reduced substantially to 9.3 mg/L with about 83 % removal rate after wetland and pond treatment systems. Nutrients removal was relatively low and removal rate for T-N and T-P was less than 43 and 44%, respectively after wetland and pond treatment. Considering stable performance and effective removal of bacterial indicators as well as other water quality parameters, low maintenance, and cost-effectiveness, pond system was thought to be an effective and feasible alternative for agricultural reuse of reclaimed water. This paper describes a preliminary result Iron pilot study and further investigations are recommended on the optimum design parameters before full scale application.

생활하수의 농업용수재이용을 위한 생활하수 오염지구 수질 모니터링 (Water quality monitoring at irrigation districts polluted with wastewater for the wastewater reuse for agriculture)

  • 김상민;박승우;강문성
    • 한국농공학회:학술대회논문집
    • /
    • 한국농공학회 2002년도 학술발표회 발표논문집
    • /
    • pp.401-404
    • /
    • 2002
  • Two irrigation districts, Maekok and Byungjum 1 which are irrigated with polluted stream flow, and one control district Kichun, that is supplied from a reservoir complying with the water quality standard are selected for water quality monitoring to identify the effects of polluted irrigation on crop yields, environments, and health hazards for farmers. The water quality at Maekok and Byungjum 1 districts are worse than the control district, and continuous water quality monitoring are needed for the wastewater reuse for agriculture.

  • PDF