• Title/Summary/Keyword: Return flow rate

Search Result 115, Processing Time 0.02 seconds

Effect of Incidence Angle of Current on the Hydraulic Resistance Capacity of Clayey Soil (흐름의 입사각이 점성토 지반의 수리저항성능에 미치는 영향)

  • Kim, Young-Sang;Han, Byung-Duck;Kang, Gyeong-O
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.24 no.1
    • /
    • pp.26-35
    • /
    • 2012
  • Until now, study on the hydraulic resistance characteristics of the ground at the river and the ocean current has been focused on the behavior under uni-directional flow without the direction change of flow. However, recent research result shows that scour rate which were measured under the bi-directional flow was much higher than those measured under uni-directional flow for both fine grained and coarse soil. Since the direction of inflow and return flow at the shore, where the structure will be constructed, is not always $180^{\circ}$, effect of the incidence angle on the hydraulic resistance capacity of the ground should be examined. Using the improved EFA which can consider the direction change of flow, hydraulic resistance capacities of the artificially composed clayey fine grained soil and clayey sandy soil under $0^{\circ}$, $90^{\circ}$, $135^{\circ}$, $180^{\circ}$ flow angle of incidence were assessed. Test result shows that hydraulic resistance capacity decreases and scour rate increase with the increase of the incidence angle between inflow and return flow. For the low consolidation pressure condition, hydraulic resistance capacity of the fine grained soil decreases rapidly. While the hydraulic resistance capacity of the coarse grained soil decreases more rapidly than fine grained soil under high consolidation pressure. Eventually since the larger the incidence angle between inflow and return flow, the larger the scour rate. Hydraulic resistance capacity under bi-directional flow($0^{\circ}{\longleftrightarrow}180^{\circ}$) should be examined for the design purpose.

Impacts of Seasonal Pumping on Stream Depletion (계절양수가 하천건천화에 미치는 영향)

  • Lee, Hyeonju;Koo, Min-Ho;Lim, Jinsil;Yoo, Byung-Ho;Kim, Yongcheol
    • Journal of Soil and Groundwater Environment
    • /
    • v.21 no.1
    • /
    • pp.61-71
    • /
    • 2016
  • Visual MODFLOW was used for quantifying stream-aquifer interactions caused by seasonal groundwater pumping. A hypothetical conceptual model was assumed to represent a stream-aquifer system commonly found in Korea. The model considered a two-layered aquifer with the upper alluvium and the lower bedrock and a stream showing seasonal water level fluctuations. Our results show that seasonal variation of the stream depletion rate (SDR) as well as the groundwater depletion depends on the stream depletion factor (SDF), which is determined by aquifer parameters and the distance from the pumping well to the stream. For pumping wells with large SDF, groundwater was considerably depleted for a long time of years and the streamflow decreased throughout the whole year. The impacts of return flow were also examined by recalculating SDR with an assumed ratio of immediate irrigation return flow to the stream. Return flow over 50% of pumping rate could increase the streamflow during the period of seasonal pumping. The model also showed that SDR was affected by both the conductance between the aquifer and the stream bed and screen depths of the pumping well. Our results can be used for preliminary assessment of water budget analysis aimed to plan an integrated management of water resources in riparian areas threatened by heavy pumping.

CFD analysis of ventilation efficiency around an elevated highway using visitation frequency and purging flow rate

  • Huang, Hong;Kato, Shinsuke;Ooka, Ryozo;Jiang, Taifeng
    • Wind and Structures
    • /
    • v.9 no.4
    • /
    • pp.297-313
    • /
    • 2006
  • The concentration of air pollution along roads is higher than the surrounding area because ventilation efficiency has decreased due to the high-density use of space along roads in recent years. In this study, ventilation efficiency around a heavily traffic road covered by an elevated highway and hemmed in along its side by buildings is evaluated using Visitation Frequency (VF, the frequency for pollutant to return to the objective domain) and Purging Flow Rate (PFR, the air flow rate for defining the local domain-averaged concentration). These are analyzed using Computational Fluid Dynamics (CFD) based on the standard $k-{\varepsilon}$ model. The VF and PFR characteristics of four objective domains are analyzed in terms of the changes in wind direction and arrangements of the fencing dividing up and down direction in the road center under the elevated highway. The resulting VFs are more than 1.0 for all cases, which means that pollutants return to the objective domain restricted by the elevated highway and side buildings. The influence of the arrangement of the buildings around the objective domain and the structure in the domain on the VF is substantial. In cases where there are no obstacles under the elevated highway, the local air exchange rate in the domain tends to be improved. Using these indices, the urban ventilation efficiencies between different urban areas can be compared easily.

A Study on Economic Evaluation of SNG Project using Real Option Valuation Model (실물옵션을 이용한 SNG 사업투자의 경제성 평가 연구)

  • Kang, Seung Jin;Hong, Jin Pyo
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.25 no.3
    • /
    • pp.319-335
    • /
    • 2014
  • This study attempts to suggest an economic analysis model for SNG projects, which can reflect the future uncertainty objectively and applies the real option valuation incorporating the flexible investment decision. Based on this analysis model, net present value and internal rate of return were estimated by using preliminary feasibility study report of SNG project. And economic evaluation of SNG project was performed with real option valuation using binomial option model. Through this, the difference of analysis results between the real option valuation model and the discounted cash flow model were compared and the usefulness of the real option valuation model was confirmed. From the actual proof analysis, it is confirmed that the real option valuation model showed higher SNG project value than the discounted cash flow model did. It was confirmed that by applying the real option valuation model, economic analysis can be performed on not only the current straightforward SNG project, but also various future portfolios having options such as expansion, modification, or decommission.

Braking Pressure Characteristics of Solenoid-Flow Control Type ABS by PWM Control (PWM 제어에 의한 솔레노이드-유량제어방식 ABS의 제동압력 특성)

  • Song, Chang-Seop;Yang, Hae-Jeong
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.14 no.8
    • /
    • pp.146-154
    • /
    • 1997
  • Solenoid-folw control type ABS is used with a 'dump and reapply' pressure control arrangement instead of using 2/2 (normal open/close) solenoid valves in convensional systems(sol. -sol. control type), a flow control valve is used which replaces the (no) inlet valve. The flow control valve controls fluid flow providing a nearly constant reapply rate( .theta. ) after the dump plase of ABS operation. In this study, to investigate a characteristics of brake pressure by PWM control, test rig was consisted of ABS hydraulic modulator, digital controller, pneumatic power supply and brake master cylinder. For comparison with experi- mental results, system modelling and computer simulation were performed. As a result, experiment results showed fairly agreement with the simulation. Also, it is shown that the pressure gradient (tan .theta. ) is affected by pressure, frequency, duty ratio and expressed with an exponential funtion.

  • PDF

A New Definition of an IRR (내부수익률의 새로운 정의)

  • Jin Wook Kim;Hyun joo Lee;Dong Soo Cha
    • Proceedings of the Society of Korea Industrial and System Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.9-18
    • /
    • 2002
  • A capital investment problem is essentially one of determining whether the anticipated cash Inflows from a proposed project are sufficiently attractive to invest funds in the project. The net present value(NPV) criterion and internal rate of return(IRR) criterion are widely used as means of making investment decisions. A positive NPV means the equivalent worth of the inflows is greater than the equivalent worth of outflows, so, the project makes profit. Business people are familiar with rates of return because they all borrow money to finance ventures, even If the money they borrow is their own. Thus they are apt to use the IRR in preference to the NPV. The IRR can be defined as the discount rate that causes the net present value of a cash flow to equal zero. Why the project are accepted if the project's IRR is greater than the investor's minimum attractive rate of return. Against the NPV, the definition cannot distinctly explain the concept of the IRR as decision criterion. We present a new definition of the IRR as the ratio of profit on the invested capital.

  • PDF

Water Balance in a Paddy Field with Pumping Irrigation System (양수장 용수공급 논 지대의 물수지)

  • 정운태;이근후;이인영
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 1998.10a
    • /
    • pp.1-7
    • /
    • 1998
  • To investigate the water balance in a paddy rice field with the pumping station for irrigation water supply, flow measurements and analysis on various components of water balance were carried out. The investigated area is 103.7 ha, and the irrigation water was supplied for 102 days during the total irrigation period starting from June 1. It was found that the consumption rate was increased as the growing stage was progressed. The variation of evapotranspiration rate was shown same tendency as the consumption rate, while no apparent tendency was found in infiltration rate upon different growing stages. And the ground water input to the area was predominant during the early stage of growing period, while ground water output from the study area was predominant at the end of the growing stage. The range of return flow rate, the ratio of total outflow to total inflow in every decad, was 57.6 to 85.7%. These values are slightly higher than reported values from the other investigation projects.

  • PDF

Improvement in Efficiency and Operating Range of Centrifugal Blower Stage for Sewage Aeration Blower

  • Hiradate, Kiyotaka;Kanno, Toshio;Nishida, Hideo;Shinkawa, Yasushi;Joukou, Satoshi
    • International Journal of Fluid Machinery and Systems
    • /
    • v.3 no.4
    • /
    • pp.379-385
    • /
    • 2010
  • We developed a high-efficiency, wide-operating-range centrifugal blower stage to meet the demand for reduced total energy-consumption in sewage treatment plants. We improved the efficiency of the two-dimensional impeller using a shape optimization tool and one-dimensional performance prediction tool. A limit of the throat deceleration ratio was set to maintain the stall-margin of the impeller. The low solidity vaned diffuser and return channel were designed using a sensitivity analysis with orthogonal arrays and three-dimensional steady flow simulations. The low solidity diffuser was designed in order to improve the performance in the low-flow-rate region. The return channel was designed so that the total pressure loss in the return channel was minimized. Model tests of both the conventional and optimized blower stages were carried out, and the efficiency and operating range of both stages were compared. The optimized blower stage improved in stage efficiency by 3% and in operating range by 5% compared with the conventional blower stage.

A Study on Improved Operation of Apartment Heating System in a Machine Room (공동주택 기계실 난방설비 운전 개선 연구)

  • Seo, Jeong-Ah;Shin, Younggy;Kim, Yong-Ki;Lee, Tae-Won
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.29 no.1
    • /
    • pp.38-42
    • /
    • 2017
  • This study proposes an idea for energy saving in apartment machine rooms. A conventional district heating system is equipped with constant-flow pumps and bypass valves to regulate pump differential pressure. Each family unit is equipped with a constant-flow on/off valve. This leads to excessive hot water circulation and a high return temperature. To reduce energy loss, this study assumes that each family unit is renovated with a heating valve which regulates the return temperature at $35^{\circ}C$. The hot water supply pump is also replaced with a pump with an inverter to vary flow rate. Expected energy savings is then estimated from field test data. According to the results, pump electricity consumption was reduced by 6,100 kWh for a family unit building over about half a year. The supply temperature can also be lowered by $5^{\circ}C$, which can contribute to a production of electricity of 10.3 kWh/ton of hot water.

A study on the Debt's Janus-Faced reality as a Way of Capital Finance (자본조달 수단으로써 부채의 양면성에 관한 연구)

  • Choi, Chang Ho;You, Yen Yoo
    • Journal of Digital Convergence
    • /
    • v.12 no.6
    • /
    • pp.115-123
    • /
    • 2014
  • The first, this study analyzed empirically the effects of net profit on sales, total asset turnover and debt ratio on return on equity, the second, verified debt' s mediating effect on return on investment and return on equity and finally, tested the effect of adjusted debt ratio on return on equity in the small medium sized enterprises. Generally speaking, using debt has a positive effect on return on equity. Meanwhile, using debt accelerate return on equity through leverage effect in the quadric function curve model. Eventually, using debt has a positive and negative effects on return on equity. Accordingly, because of the debt' janus-faced reality, using debt is restricted within the level that operating cash flow(or return on asset) excess interest(or rate of interest).