• Title/Summary/Keyword: Retention force

Search Result 169, Processing Time 0.025 seconds

The properties of pad conditioning according to manufacturing methods of CMP pad conditioner (CMP 패드 컨디셔너의 제조공법에 따른 패드 컨디셔닝 특성)

  • Kang S.K.;Song M.S.;Jee W.H.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.10a
    • /
    • pp.362-365
    • /
    • 2005
  • Currently Chemical Mechanical Planarization (CMP) has become an essential step in the overall semiconductor wafer fabrication technology. Especially the CMP pad conditioner, one of the diamond tools, is required to have strong diamond retention. Strong cohesion between diamond grits and metal matrix prevents macro scratch on the wafer. If diamond retention is weak, the diamond will be pulled out of metal matrix. The pulled diamond grits are causative of macro scratch on wafer during CMP process. Firstly, some results will be reported of cohesion between diamond grits and metal matrix on the diamond tools prepared by three different manufacturing methods. A measuring instrument with sharp cemented carbide connected with a push-pull gauge was manufactured to measure the cohesion between diamond grits and metal matrix. The retention force of brazed diamond tool was stronger than the others. The retention force was also increased in proportion to the contact area of diamond grits and metal matrix. The brazed diamond tool has a strong chemical combination of the interlayer composed of chrome in metal matrix and carbon which enhance the interfacial cohesion strength between diamond grits and metal matrix. Secondly, we measured real-time data of the coefficient of friction and the pad wear rate by using CMP tester (CETR, CP-4). CMP pad conditioner samples were manufactured by brazed, electro-plated and sintered methods. The coefficient of friction and the pad wear rate were shown differently according to the arranged diamond patterns. Consequently, the coefficient of friction is increased according as the space between diamonds is increased or the concentration of diamonds is decreased. The pad wear rate is increased according as the degree of diamond protrusion is increased.

  • PDF

Changes in occlusal force and occlusal contact area after orthodontic treatment (교정 치료 후 교합력, 교합면적의 변화)

  • Choi, Yoon-Jeong;Chung, Choo-Ryung J.;Kim, Kyung-Ho
    • The korean journal of orthodontics
    • /
    • v.40 no.3
    • /
    • pp.176-183
    • /
    • 2010
  • Objective: This study was performed to evaluate functional changes of occlusion after orthodontic treatment by measuring the occlusal force (OcFr) and occlusal contact area (OcAr), and to compare OcFr and OcAr change according to premolar extractions. Methods: Data were obtained from 74 patients who had finished orthodontic treatment using fixed appliance aged between 18 and 40 years. Subjects were divided into groups who had four premolars extractions or non-extraction (Male extraction-16, Male nonextraction-18, Female extraction-19, Female nonextraction-21). All subjects were asked to bite pressure-sensitive sheets into maximum intercuspation with maximum bite force, and OcFr and OcAr were evaluated by measuring the sheet with a CCD camera. Records were taken right after debonding, 1 week, 1 month, 3 months, 6 months and 1 year after debonding. Results: OcFr and OcAr increased gradually in all groups during the 1 year retention period (p < 0.05). Male groups showed higher OcFr and OcAr than female groups throughout the retention periods (p < 0.05). There were no statistically significant differences of OcFr and OcAr between extraction and non-extraction groups in both males and females (p > 0.05). Conclusions: Occlusion was improved functionally throughout the 1 year retention, and premolar extraction did not induce a decline in the functional aspect of occlusion.

AN EXPERIMENTAL STUDY ON RETENTIVE PROPERTIES OF VARIOUS PINS IN DENTIM (수종수복용 Pin의 유지력에 관한 실험적 연구)

  • Lee, Myung-Chong
    • The Journal of the Korean dental association
    • /
    • v.15 no.11
    • /
    • pp.763-766
    • /
    • 1977
  • The Purpose of this study was to observe force required to remove some kinds of pin from dentin. The teeth were embedded within a resin cylinder and the occlusal surface was sectioned at a right angle to the axis of the cylinder to expose dentin surface. Thread mate system pin (minim and regular), friction Iocked pin and cemented pin were tested Pin holes were drilled by handpiece and depths of pin holes were tested 1,2 and 3mm. After insertion of the pins into pinhole, tensile loading was performed on the Instron testing machine at the speed of 0.5 inch/min. Results were follewed: 1. In retention, the cemented pins are the least, the friction locked pins intermediate and the self threading pins the greatest in all pins. In self threading pins, regalar pin has greater retention than minim pin 2. The deeper the depth of the pin hole is, the more the retention of the pin increases.

  • PDF

Uniform bend transition and twist retention time improvement in a bistable chiral splay nematic liquid crystal cell

  • Kang, Sang-Ho;Jhun, Chul-Gyu;Lee, Seong-Ryong;Kim, Jae-Chang;Yoon, Tae-Hoon
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.1173-1176
    • /
    • 2004
  • In a previous work we reported the bistable property by doping a chiral material in a splay cell. The bistable states are the splay state and the metastable 180$^{\circ}$twist state. The retention time of the metastable state can be changed by the variation of d/p (cell gap over pitch), cell gap, pretilt angle, azimuthal anchoring force, liquid crystal material, and so on. In this paper we will present uniform bend transition and twist retention time improvement in a multi-domain BCSN LC cell by using the multi cell gap method.

  • PDF

Effect of Hydraulic Retention Time on Biological Nitrogen Removal in Land-based Fish Farm Wastewater (육상양식장 배출수내 생물학적 질소처리시 수리학적 체류시간의 영향)

  • Park, Noh-Back
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.50 no.3
    • /
    • pp.250-256
    • /
    • 2017
  • This study investigated the removal efficiency of organic matter and nitrogen from fish farm effluent by hydraulic retention time (HRT) using an upflow biological filter (ANR system) reactor. The recycling time and influent flow in the reactor were controlled to 14.8, 7.4, 5.5 and 3.2 h to evaluate HRT. In addition, each reactor was coupled to a fixed bed upflow filter charged with media. The results showed that removal efficiency was ${\geq}95%%$ with an HRT of 5.5 h, and nitrification efficiency was reduced to 81% with an HRT of 3.2 h, although nitrification efficiency temporarily decreased due to the shock load as HRT decreased. Total nitrogen removal rate was also reduced to about 65% with an HRT of 3.2 h, which was considered a washout effect of nitrifying and denitrifying microorganisms by increasing the shearing force to the filter media, which decreased organic matter and nitrogen removal efficiency.

IPS Earth Retention System (IPS(Innovative Prestressed Wale System) 흙막이 공법의 개발)

  • Park, Jong-Sik;Kim, Nak-Kyung;Han, Man-Yop;Kim, Jong-Woo
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2004.03b
    • /
    • pp.293-300
    • /
    • 2004
  • A new earth retention system(Innovative Prestressed Wale System) has been developed and introduced. IPR earth retention system provides an economical benefit, construction easiness, good performance and safety. IPS is a prestressed wale by using a steel wire, which provides a high stiffness to resist the earth pressure. In order to investigate the applicability and the safety of new IPS system, field tests were performed. A new IPS system applied in a trench excavation performed successfully. Basic principles and mechanism of IPS system and measure performance were presented and discussed.

  • PDF

Theoretical and Experimental Studies on Optical Particle Separator (광 이동도에 대한 개념과 실험적 검증)

  • Kim, Sang-Bok;Jung, Eun-Jung;Sung, Hyung-Jin;Kim, Sang-Soo
    • Proceedings of the KSME Conference
    • /
    • 2008.11b
    • /
    • pp.2406-2409
    • /
    • 2008
  • The concept of optical mobility in the optical particle separation was derived. To verify the concept of the optical mobility, three particles were chosen to test the effects of optical mobility, namely, PSL, PMMA and silica particles. Three different experiments were performed. Firstly, retention distances of the different sized particles were measured and predicted. Secondly, retention distances of particles, having same size but different refractive indices, were measured and predicted. Finally, retention distances of the particles, which had the same optical mobility but very different sized and refractive indices, were measured and predicted.

  • PDF

A Model Test of Earth Retention System with Prestressed Wale (프리스트레스트 띠장을 적용한 흙막이 시스템의 모형 시험)

  • Park, Jong-Sik;Kim, Sung-Kyu;Joo, Yong-Sun;Jang, Ho-June;Kim, Nak-Kyung
    • Journal of the Korean Geotechnical Society
    • /
    • v.23 no.7
    • /
    • pp.27-36
    • /
    • 2007
  • A model test was performed to evaluate the stability of a new earth retention system with a prestressed wale. For the model test, the dimensional analysis of a full-scaled earth retention system with prestressed wales was performed. Details of the dimensional analysis of the new earth retention system were presented in this paper. Based on the results of the dimensional analysis, the model-scaled earth retention system with a prestressed wale was simulated. The lateral earth pressures on the wall, the lateral deflection of the prestressed wale, the sectional force on members of the prestressed wale system, and the loads of struts were measured during construction simulation. The measured results were evaluated and compared with those of the design criterion. From the measurements, the behavior of this earth retention system was investigated.

Quantitative Comparison of Acupuncture Needle Force Generation According to Diameter

  • Lee, YeonSun;Bong, SungMin;Kim, Eun Jung;Lee, Seung Deok;Jung, Chan Yung
    • Journal of Acupuncture Research
    • /
    • v.35 no.4
    • /
    • pp.238-243
    • /
    • 2018
  • Background: Various factors can alter the efficacy of acupuncture treatment, such as the location of points, manipulations, depth of insertion, needle retention time, and needle type. In this study, the effect of needle diameter on the efficacy of acupuncture treatment was quantitatively evaluated. Methods: Five acupuncture needles of different diameters used in clinical practice were compared. Force on the porcine tissue phantom was measured using a sensor. Lifting-thrusting and twisting-rotating movements were performed using a needle insertion-measurement system. After repeated measurements, force magnitude was calculated and compared. Following this, we correlated needle diameter and force magnitude during lifting-thrusting and twisting-rotating movements. Results: The force magnitude was significantly altered between needle diameters during lifting-thrusting movements, as shown by a significant positive correlation between needle diameter and force magnitude. In contrast, there was no difference in force magnitude with different needle diameters during twisting-rotating movements. Conclusion: Needle diameter can significantly affect stimuli and force magnitude dependent upon the type of manipulation. Research into the effect of other needle type characteristics and stimulation method is necessary to fully elucidate the role of acupuncture needle choice in treatment efficacy.